Empowering Scientific Discovery

Beijing Ingerheid Analytical Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelIG5C
PriceUpon Request
Ion Energy Range500 eV – 5 keV
Maximum Beam Current200 nA
Minimum Spot Size20 µm
Ion Source Lifetime~500 hours
Flange TypeDN-35 CF Conflat Wedge Flange
Power Consumption8 W
Filament ConfigurationDual-filament
Vacuum CompatibilityOptimized for UHV systems (<1×10⁻⁹ mbar)
Beam BlankingIntegrated electrostatic blanking for rapid beam on/off switching in grating applications
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginUnited Kingdom
ModelHAL/3F
Mass Range1–50 amu (high-resolution quadrupole)
Detection Sensitivityppm-level
Long-term Stability< ±0.5% peak height drift over 24 h
Ionization ModesElectron Impact (EI), Threshold Ionization (e.g., D₂/He selective detection)
Software ControlMASsoft v6.x
Data OutputASCII, DDE-compatible (Excel, SPC-IV, custom SCADA/HMI systems)
ComplianceCE-marked, RoHS-compliant, designed for vacuum system integration per ISO 27893 and ASTM E1940-20
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginUnited Kingdom
ModelHALO 201 MBE
Mass Range1–300 amu
Scan Speed100 amu/s
Minimum Scan Step0.01 amu
Sensitivity0.1–1 ppm
Long-Term Stability< ±0.5% peak height drift over 24 h
Minimum Detectable Partial Pressure2 × 10⁻¹³ mbar
Maximum Operating Pressure1 × 10⁻⁴ mbar
DetectorDual Faraday/Channelplate Electron Multiplier
Ion Source ShieldContamination-Resistant
Filament WiringMolybdenum-Copper Alloy
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIONICON Analytik G m.b.H.
OriginAustria
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPTR-TOF QB
Detection PrincipleProton-Transfer-Reaction Time-of-Flight Mass Spectrometry (PTR-TOF MS)
Instrument TypePortable
Typical ConfigurationMulti-Analyte VOC Analyzer
Detection RangeC2–C12 Volatile Organic Compounds (VOCs), including aldehydes, ketones, aromatics, terpenes, oxygenates, and sulfur-containing compounds
Mass Resolution (m/Δm)4000 (FWHM at m/z 200)
Accuracy±5% relative to certified standard gas mixtures
Response Time<100 ms (10–90% rise time for individual compounds)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandC-Therm
ModelTrident
Measurement PrincipleIntegrated Modified Transient Plane Source (MTPS), Flexible Transient Plane Source (Flex TPS), and Transient Line Source (TLS Needle)
Thermal Conductivity Range0–2000 W/m·K
Accuracy<5%
Repeatability<1%
Operating Temperature Range–50°C to +500°C
Dimensions (L×W×H)40 × 40 × 40 cm
ComplianceASTM D7984, ISO 22007-2.2, ASTM D5334, ASTM D5930, IEEE 442, GB/T 32064
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginUnited Kingdom
ModelXEMIS
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Number of Analysis Stations1
Pore Size Measurement Range< 50 nm
Temperature Range77 K to 773 K (–196 °C to 500 °C)
Pressure RangeUp to 200 bar
Analysis TheoryBJH, Langmuir, DFT, t-plot, α<sub>s</sub>-method
Balance Capacity5 g
Balance Resolution0.2 µg
Long-term Stability±5 µg
Dynamic Weighing Range0–200 mg
ConstructionAll-metal VCR-fitted architecture
ComplianceDesigned for GLP/GMP environments with audit-trail-capable software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIONICON Analytik G.m.b.H.
OriginAustria
ModelPTR-TOF 1000
Detection PrincipleProton Transfer Reaction (PTR) coupled with Time-of-Flight Mass Spectrometry
Instrument TypeOnline Real-Time Analyzer
Typical ConfigurationIntegrated VOC Monitoring System
Detection Range10 pptv – 1 ppmv
Resolution1 pptv
Accuracy±10 pptv
Response Time≤100 ms
Mass Range1–10,000 Th
Mass Resolving Power>1500 (m/Δm)
Sampling Flow Rate50–800 sccm
Inlet & Reaction Chamber Heating40–180 °C and 40–120 °C respectively
Power Supply100–230 V AC, max. 1000 W
Dimensions (W×H×D)60 × 91 × 80 cm
Weight150 kg
Data InterfacesEthernet, RS232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginUnited Kingdom
ModelqRGA
Mass Range1–200 amu
Ionization ModeThreshold Ionization Mass Spectrometry (TIMS)
Electron Energy Resolution0.1 eV
Soft Ionization Range0–150 eV
Long-Term Stability< ±0.5% peak height drift over 24 h
Detection Limitppm-level quantification
ShieldingIntegrated radiation and magnetic shielding
Operational ModeDual-mode (conventional scanning + TIMS)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginUnited Kingdom
ModelHPR20
Mass Rangeup to 510 amu
Detection Limitdown to 5 ppb
Response Time< 500 ms
Sample Flow Rate1–20 cm³/min
Sampling Pressure Range10 mbar to 2 bar (optional high-pressure inlet up to 30 bar)
Capillary Temperatureup to 200 °C
Ion Source Pressure ControlAutomatic via integrated mass flow controller
Cryogenic TrapLiquid nitrogen-cooled cold finger for condensable species
IonizationSoft electron ionization (EI) with adjustable electron energy
Long-Term Stability±0.5% peak height drift over 24 h
Communication InterfacesRS232, RS485, Ethernet
SoftwareMASsoft Professional v6.x with GLP-compliant audit trail and calibration management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginUnited Kingdom
ModelQGA 2.0
Detection Range100 ppb to 100%
Scan SpeedUp to 1000 spectra per second
Form FactorBenchtop, Compact Design
ComplianceCE-marked, RoHS-compliant construction
SoftwareQGA 2.0 Quantitative Analysis Suite (Windows-based, FDA 21 CFR Part 11 ready)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginUnited Kingdom
ModelEQP
Mass Rangeup to 2500 amu
Energy Resolution0.05 eV step / 0.25 eV FWHM
Ion DetectionPulse-counting detector with 7-decade dynamic range
Signal Gating Resolution1 µs
Optional Floating Voltageup to 10 kV
InterfaceRS232, RS485, or Ethernet LAN
Detector OptionsFaraday cup (high-density plasmas), electron attachment source (for apparent potential spectroscopy)
Vacuum SystemTriple-differentially pumped quadrupole with 45° electrostatic sector energy analyser
Shielding OptionsMu-metal and radio-metal shielding available
SafetyIntegrated Penning gauge and interlock system for overpressure protection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginUnited Kingdom
ModelPSM
Mass Range0–2500 u
DetectionPulsed Ion Counting Detector (7-decade dynamic range)
Energy Analysis OptionStandard ±100 eV (up to ±1000 eV optional)
Signal Gating Resolution1 µs
QuadrupoleTriple-stage filtered, high-stability
Ion/Neutral AnalysisSimultaneous positive/negative ion and neutral/radical detection
Vacuum InterfaceDifferential pumping manifold with flanged process chamber coupling
Control InterfaceRS232, RS485, or Ethernet LAN
SoftwareMASsoft Professional Suite
Optional FeaturesElectron Attachment Ion Source (tunable appearance potential MS), Penning gauge + interlock for overpressure protection, Mu-Metal/Radio-Metal magnetic shielding, High-voltage operation capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginAustria
ModelTGA-MS
Interface TypeCapillary Direct-Coupling Interface
Dead VolumeMinimized (< 10 µL)
Capillary Temperature ControlUp to 300 °C
Material of ConstructionInert (High-Purity Stainless Steel, SilcoNert®-treated Surfaces)
Gas HandlingDual-Channel Mass Flow Controlled (H₂, He, N₂, Ar Compatible)
Flow Rate Range0.1–50 mL/min (Adjustable to Match TGA Effluent Profile)
ComplianceASTM E2550, ISO 11358, USP <1210>
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelEQS
Instrument TypeQuadrupole Mass Spectrometer
Mass RangeUp to 2500 u
Analyzer Type45° Electrostatic Sector
Energy Resolution0.05 eV step / 0.25 eV FWHM
DetectionHigh-Sensitivity Pulsed Ion Counting Detector (7-decade dynamic range)
PumpingThree-Stage Differential Pumping System
Ion OpticsGrating-Controlled Depth Profiling Capability
InterfaceUHV-Compatible “Bolt-On” Mounting for Existing Surface Science Chambers
CompatibilityFully Integrated with Hiden SIMS Workstation and MASsoft Control Software
SafetyPenning Gauge Interlock for Overpressure Protection
CommunicationRS232, RS485, or Ethernet LAN
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginUnited Kingdom
ModelHPR30
Mass RangeUp to 1000 amu
Detection LimitDown to 5 ppb
Operating Pressure Range1×10⁻⁴ mbar to 1 mbar
IonizationSoft Electron Ionization (EI) with Tunable Energy
Sensitivity OptimizationDirect re-entrant sampling orifice + differential pumping stage
Stability< ±0.5% peak height drift over 24 h
Control SoftwareMASsoft v6.x (Windows-based, LAN-capable)
Safety InterlocksPneumatic isolation valve with pressure- and power-failure actuation
Data AcquisitionSimultaneous real-time acquisition, spectral processing, and alarm triggering
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginUnited Kingdom
ModelMAXIM
Mass Range Options300 amu / 500 amu / 1000 amu
Mass Analyzer3F Quadrupole (9 mm rod diameter)
DetectorPulse-counting ion detector, dual-polarity (positive/negative ions), max. count rate 10⁷ cps
Ion SourceElectron Impact (single-filament), configurable for SNMS and Residual Gas Analysis (RGA)
Sample Stage HeatingUp to 250 °C
Optical Acceptance Angle30° for planar particle sampling in SIMS/SNMS geometry
Ion TransmissionOptimized for minimal trajectory perturbation across full energy range
Depth Profiling CapabilityEnhanced via grating-controlled beam optics
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginAustria
ModelSpaciMS
Inlet Channels16
Axial Travel Range0–300 mm
Spatial Resolution0.1 mm
Application DomainCatalytic Reactor Process Monitoring, Transient Gas Analysis, 3D Gas Composition Mapping
Added to wishlistRemoved from wishlist 0
Add to compare
BrandC-Therm
OriginCanada
ModelTrident TPS
Measurement PrincipleTransient Plane Source (TPS)
Dimensions (L×W×H)40 × 40 × 40 cm
Accuracy< 5%
Thermal Conductivity Range0 – 2000 W/m·K
Thermal Diffusivity Range0 – 1200 mm²/s
Specific Heat Capacity Range0 – 5 MJ/m³·K
Effusivity Range0 – 40,000 W·s⁰·⁵/m²·K
Repeatability< 1%
Test Duration0.8 – 180 s
ComplianceISO 22007-2:2015, GB/T 32064-2015
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginUnited Kingdom
ModelMBR
Instrument TypePhysical/Chemical Adsorption Analyzer
Operating Pressure RangeUp to 10 bar
Temperature Range120°C to 300°C
Flow Configuration ModesCo-current and Cross-flow
Integrated DetectionClose-coupled Quadrupole Mass Spectrometer (QMS)
Valve ArchitecturePneumatically Actuated, Ultra-Low-Dead-Volume Switching Valves
Control SystemFully Programmable, Automated Sequence Execution
Membrane CellPrecision-Machined, Integral Support Structure
ComplianceDesigned for ASTM D1434, ISO 15105-1, and ISO 2556 gas permeation test protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginUnited Kingdom
ModelESPion
Probe TypeElectrically Compensated, RF-Shielded Langmuir Probe
Operating Frequency RangeDC to 13.56 MHz
Maximum Scan Rate15 sweeps per second
Probe Drive Options300 mm / 600 mm / 915 mm motorized linear actuators, optional linear-rotary combi-drive
CoolingGas-cooled multi-sensor chain for high-temperature plasma operation
CompensationPassive RF compensation (4.25 MΩ @ 13.56 MHz), reference probe for low-frequency drift & noise rejection
Data InterfaceRS232, RS485, Ethernet LAN
SoftwareESPsoft v5.x with pulse-gating, EEDF reconstruction, and automated plasma parameter extraction
ComplianceDesigned for GLP-compliant plasma diagnostics
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelXEMIS
Pricing RangeUSD 130,000–260,000 (FOB)
Measurement PrincipleGravimetric Method
Temperature Range77 K to 773 K (–196 °C to 500 °C)
Pressure RangeUltra-High Vacuum (UHV) to 200 bar
Ultimate Vacuum1 × 10⁻⁸ Torr
Sensitivity0.2 µg
Long-Term Stability±5 µg
Maximum Sample Capacity5 g
Dynamic Weighing Range0–200 mg
ConstructionAll-Metal VCR-Sealed Architecture
CalibrationZero-Drift-Free Operation, No In-Situ Re-Zero Required
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelIGA100
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiden
OriginUnited Kingdom
ModelSIMS
Vacuum CompatibilityUltra-High Vacuum (UHV)
Ion SourcesIG20 Ion Gun (differential pumping), IFG200 FAB Source, Liquid Gallium Liquid Metal Ion Gun (LMIG)
Detection Limit<1 ppb (for selected elements under optimized conditions)
Sample Manipulator4-Axis (X, Y, Z, θ) UHV-Compatible
Charge NeutralizationElectron Flood Gun
Cryogenic CapabilityIntegrated Liquid Nitrogen Cold Trap
Vacuum SystemBakeable UHV Chamber with RGA Monitoring
Mass AnalyzerHiden EQS Quadrupole Mass Spectrometer
Control & Acquisition SoftwareMASsoft Operating System with ESM LabVIEW Interface and SIMS Imaging Module
ComplianceDesigned for GLP/GMP-adjacent surface analysis workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIONICON Analytik GmbH
OriginAustria
ModelMulti-Port Sampling Device
Valve Configurations2-way and 3-way
Port Options12-, 16-, 18-, or custom-configurable inlet ports
Material OptionsPTFE- or PEEK-coated valve bodies
ApplicationAutomated, sequential vapor/sampling stream selection for real-time analytical systems
ComplianceDesigned for integration with PTR-MS, SIFT-MS, and other trace gas analyzers
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0