| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IG5C |
| Price | Upon Request |
| Ion Energy Range | 500 eV – 5 keV |
| Maximum Beam Current | 200 nA |
| Minimum Spot Size | 20 µm |
| Ion Source Lifetime | ~500 hours |
| Flange Type | DN-35 CF Conflat Wedge Flange |
| Power Consumption | 8 W |
| Filament Configuration | Dual-filament |
| Vacuum Compatibility | Optimized for UHV systems (<1×10⁻⁹ mbar) |
| Beam Blanking | Integrated electrostatic blanking for rapid beam on/off switching in grating applications |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HAL/3F |
| Mass Range | 1–50 amu (high-resolution quadrupole) |
| Detection Sensitivity | ppm-level |
| Long-term Stability | < ±0.5% peak height drift over 24 h |
| Ionization Modes | Electron Impact (EI), Threshold Ionization (e.g., D₂/He selective detection) |
| Software Control | MASsoft v6.x |
| Data Output | ASCII, DDE-compatible (Excel, SPC-IV, custom SCADA/HMI systems) |
| Compliance | CE-marked, RoHS-compliant, designed for vacuum system integration per ISO 27893 and ASTM E1940-20 |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HALO 201 MBE |
| Mass Range | 1–300 amu |
| Scan Speed | 100 amu/s |
| Minimum Scan Step | 0.01 amu |
| Sensitivity | 0.1–1 ppm |
| Long-Term Stability | < ±0.5% peak height drift over 24 h |
| Minimum Detectable Partial Pressure | 2 × 10⁻¹³ mbar |
| Maximum Operating Pressure | 1 × 10⁻⁴ mbar |
| Detector | Dual Faraday/Channelplate Electron Multiplier |
| Ion Source Shield | Contamination-Resistant |
| Filament Wiring | Molybdenum-Copper Alloy |
| Brand | IONICON Analytik G m.b.H. |
|---|---|
| Origin | Austria |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PTR-TOF QB |
| Detection Principle | Proton-Transfer-Reaction Time-of-Flight Mass Spectrometry (PTR-TOF MS) |
| Instrument Type | Portable |
| Typical Configuration | Multi-Analyte VOC Analyzer |
| Detection Range | C2–C12 Volatile Organic Compounds (VOCs), including aldehydes, ketones, aromatics, terpenes, oxygenates, and sulfur-containing compounds |
| Mass Resolution (m/Δm) | 4000 (FWHM at m/z 200) |
| Accuracy | ±5% relative to certified standard gas mixtures |
| Response Time | <100 ms (10–90% rise time for individual compounds) |
| Brand | C-Therm |
|---|---|
| Model | Trident |
| Measurement Principle | Integrated Modified Transient Plane Source (MTPS), Flexible Transient Plane Source (Flex TPS), and Transient Line Source (TLS Needle) |
| Thermal Conductivity Range | 0–2000 W/m·K |
| Accuracy | <5% |
| Repeatability | <1% |
| Operating Temperature Range | –50°C to +500°C |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Compliance | ASTM D7984, ISO 22007-2.2, ASTM D5334, ASTM D5930, IEEE 442, GB/T 32064 |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | XEMIS |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Number of Analysis Stations | 1 |
| Pore Size Measurement Range | < 50 nm |
| Temperature Range | 77 K to 773 K (–196 °C to 500 °C) |
| Pressure Range | Up to 200 bar |
| Analysis Theory | BJH, Langmuir, DFT, t-plot, α<sub>s</sub>-method |
| Balance Capacity | 5 g |
| Balance Resolution | 0.2 µg |
| Long-term Stability | ±5 µg |
| Dynamic Weighing Range | 0–200 mg |
| Construction | All-metal VCR-fitted architecture |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Brand | IONICON Analytik G.m.b.H. |
|---|---|
| Origin | Austria |
| Model | PTR-TOF 1000 |
| Detection Principle | Proton Transfer Reaction (PTR) coupled with Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Real-Time Analyzer |
| Typical Configuration | Integrated VOC Monitoring System |
| Detection Range | 10 pptv – 1 ppmv |
| Resolution | 1 pptv |
| Accuracy | ±10 pptv |
| Response Time | ≤100 ms |
| Mass Range | 1–10,000 Th |
| Mass Resolving Power | >1500 (m/Δm) |
| Sampling Flow Rate | 50–800 sccm |
| Inlet & Reaction Chamber Heating | 40–180 °C and 40–120 °C respectively |
| Power Supply | 100–230 V AC, max. 1000 W |
| Dimensions (W×H×D) | 60 × 91 × 80 cm |
| Weight | 150 kg |
| Data Interfaces | Ethernet, RS232 |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | qRGA |
| Mass Range | 1–200 amu |
| Ionization Mode | Threshold Ionization Mass Spectrometry (TIMS) |
| Electron Energy Resolution | 0.1 eV |
| Soft Ionization Range | 0–150 eV |
| Long-Term Stability | < ±0.5% peak height drift over 24 h |
| Detection Limit | ppm-level quantification |
| Shielding | Integrated radiation and magnetic shielding |
| Operational Mode | Dual-mode (conventional scanning + TIMS) |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HPR20 |
| Mass Range | up to 510 amu |
| Detection Limit | down to 5 ppb |
| Response Time | < 500 ms |
| Sample Flow Rate | 1–20 cm³/min |
| Sampling Pressure Range | 10 mbar to 2 bar (optional high-pressure inlet up to 30 bar) |
| Capillary Temperature | up to 200 °C |
| Ion Source Pressure Control | Automatic via integrated mass flow controller |
| Cryogenic Trap | Liquid nitrogen-cooled cold finger for condensable species |
| Ionization | Soft electron ionization (EI) with adjustable electron energy |
| Long-Term Stability | ±0.5% peak height drift over 24 h |
| Communication Interfaces | RS232, RS485, Ethernet |
| Software | MASsoft Professional v6.x with GLP-compliant audit trail and calibration management |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | QGA 2.0 |
| Detection Range | 100 ppb to 100% |
| Scan Speed | Up to 1000 spectra per second |
| Form Factor | Benchtop, Compact Design |
| Compliance | CE-marked, RoHS-compliant construction |
| Software | QGA 2.0 Quantitative Analysis Suite (Windows-based, FDA 21 CFR Part 11 ready) |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | EQP |
| Mass Range | up to 2500 amu |
| Energy Resolution | 0.05 eV step / 0.25 eV FWHM |
| Ion Detection | Pulse-counting detector with 7-decade dynamic range |
| Signal Gating Resolution | 1 µs |
| Optional Floating Voltage | up to 10 kV |
| Interface | RS232, RS485, or Ethernet LAN |
| Detector Options | Faraday cup (high-density plasmas), electron attachment source (for apparent potential spectroscopy) |
| Vacuum System | Triple-differentially pumped quadrupole with 45° electrostatic sector energy analyser |
| Shielding Options | Mu-metal and radio-metal shielding available |
| Safety | Integrated Penning gauge and interlock system for overpressure protection |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | PSM |
| Mass Range | 0–2500 u |
| Detection | Pulsed Ion Counting Detector (7-decade dynamic range) |
| Energy Analysis Option | Standard ±100 eV (up to ±1000 eV optional) |
| Signal Gating Resolution | 1 µs |
| Quadrupole | Triple-stage filtered, high-stability |
| Ion/Neutral Analysis | Simultaneous positive/negative ion and neutral/radical detection |
| Vacuum Interface | Differential pumping manifold with flanged process chamber coupling |
| Control Interface | RS232, RS485, or Ethernet LAN |
| Software | MASsoft Professional Suite |
| Optional Features | Electron Attachment Ion Source (tunable appearance potential MS), Penning gauge + interlock for overpressure protection, Mu-Metal/Radio-Metal magnetic shielding, High-voltage operation capability |
| Brand | Hiden |
|---|---|
| Origin | Austria |
| Model | TGA-MS |
| Interface Type | Capillary Direct-Coupling Interface |
| Dead Volume | Minimized (< 10 µL) |
| Capillary Temperature Control | Up to 300 °C |
| Material of Construction | Inert (High-Purity Stainless Steel, SilcoNert®-treated Surfaces) |
| Gas Handling | Dual-Channel Mass Flow Controlled (H₂, He, N₂, Ar Compatible) |
| Flow Rate Range | 0.1–50 mL/min (Adjustable to Match TGA Effluent Profile) |
| Compliance | ASTM E2550, ISO 11358, USP <1210> |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EQS |
| Instrument Type | Quadrupole Mass Spectrometer |
| Mass Range | Up to 2500 u |
| Analyzer Type | 45° Electrostatic Sector |
| Energy Resolution | 0.05 eV step / 0.25 eV FWHM |
| Detection | High-Sensitivity Pulsed Ion Counting Detector (7-decade dynamic range) |
| Pumping | Three-Stage Differential Pumping System |
| Ion Optics | Grating-Controlled Depth Profiling Capability |
| Interface | UHV-Compatible “Bolt-On” Mounting for Existing Surface Science Chambers |
| Compatibility | Fully Integrated with Hiden SIMS Workstation and MASsoft Control Software |
| Safety | Penning Gauge Interlock for Overpressure Protection |
| Communication | RS232, RS485, or Ethernet LAN |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HPR30 |
| Mass Range | Up to 1000 amu |
| Detection Limit | Down to 5 ppb |
| Operating Pressure Range | 1×10⁻⁴ mbar to 1 mbar |
| Ionization | Soft Electron Ionization (EI) with Tunable Energy |
| Sensitivity Optimization | Direct re-entrant sampling orifice + differential pumping stage |
| Stability | < ±0.5% peak height drift over 24 h |
| Control Software | MASsoft v6.x (Windows-based, LAN-capable) |
| Safety Interlocks | Pneumatic isolation valve with pressure- and power-failure actuation |
| Data Acquisition | Simultaneous real-time acquisition, spectral processing, and alarm triggering |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | MAXIM |
| Mass Range Options | 300 amu / 500 amu / 1000 amu |
| Mass Analyzer | 3F Quadrupole (9 mm rod diameter) |
| Detector | Pulse-counting ion detector, dual-polarity (positive/negative ions), max. count rate 10⁷ cps |
| Ion Source | Electron Impact (single-filament), configurable for SNMS and Residual Gas Analysis (RGA) |
| Sample Stage Heating | Up to 250 °C |
| Optical Acceptance Angle | 30° for planar particle sampling in SIMS/SNMS geometry |
| Ion Transmission | Optimized for minimal trajectory perturbation across full energy range |
| Depth Profiling Capability | Enhanced via grating-controlled beam optics |
| Brand | Hiden |
|---|---|
| Origin | Austria |
| Model | SpaciMS |
| Inlet Channels | 16 |
| Axial Travel Range | 0–300 mm |
| Spatial Resolution | 0.1 mm |
| Application Domain | Catalytic Reactor Process Monitoring, Transient Gas Analysis, 3D Gas Composition Mapping |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Model | Trident TPS |
| Measurement Principle | Transient Plane Source (TPS) |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | < 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Thermal Diffusivity Range | 0 – 1200 mm²/s |
| Specific Heat Capacity Range | 0 – 5 MJ/m³·K |
| Effusivity Range | 0 – 40,000 W·s⁰·⁵/m²·K |
| Repeatability | < 1% |
| Test Duration | 0.8 – 180 s |
| Compliance | ISO 22007-2:2015, GB/T 32064-2015 |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | MBR |
| Instrument Type | Physical/Chemical Adsorption Analyzer |
| Operating Pressure Range | Up to 10 bar |
| Temperature Range | 120°C to 300°C |
| Flow Configuration Modes | Co-current and Cross-flow |
| Integrated Detection | Close-coupled Quadrupole Mass Spectrometer (QMS) |
| Valve Architecture | Pneumatically Actuated, Ultra-Low-Dead-Volume Switching Valves |
| Control System | Fully Programmable, Automated Sequence Execution |
| Membrane Cell | Precision-Machined, Integral Support Structure |
| Compliance | Designed for ASTM D1434, ISO 15105-1, and ISO 2556 gas permeation test protocols |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | ESPion |
| Probe Type | Electrically Compensated, RF-Shielded Langmuir Probe |
| Operating Frequency Range | DC to 13.56 MHz |
| Maximum Scan Rate | 15 sweeps per second |
| Probe Drive Options | 300 mm / 600 mm / 915 mm motorized linear actuators, optional linear-rotary combi-drive |
| Cooling | Gas-cooled multi-sensor chain for high-temperature plasma operation |
| Compensation | Passive RF compensation (4.25 MΩ @ 13.56 MHz), reference probe for low-frequency drift & noise rejection |
| Data Interface | RS232, RS485, Ethernet LAN |
| Software | ESPsoft v5.x with pulse-gating, EEDF reconstruction, and automated plasma parameter extraction |
| Compliance | Designed for GLP-compliant plasma diagnostics |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XEMIS |
| Pricing Range | USD 130,000–260,000 (FOB) |
| Measurement Principle | Gravimetric Method |
| Temperature Range | 77 K to 773 K (–196 °C to 500 °C) |
| Pressure Range | Ultra-High Vacuum (UHV) to 200 bar |
| Ultimate Vacuum | 1 × 10⁻⁸ Torr |
| Sensitivity | 0.2 µg |
| Long-Term Stability | ±5 µg |
| Maximum Sample Capacity | 5 g |
| Dynamic Weighing Range | 0–200 mg |
| Construction | All-Metal VCR-Sealed Architecture |
| Calibration | Zero-Drift-Free Operation, No In-Situ Re-Zero Required |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IGA100 |
| Pricing | Upon Request |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | SIMS |
| Vacuum Compatibility | Ultra-High Vacuum (UHV) |
| Ion Sources | IG20 Ion Gun (differential pumping), IFG200 FAB Source, Liquid Gallium Liquid Metal Ion Gun (LMIG) |
| Detection Limit | <1 ppb (for selected elements under optimized conditions) |
| Sample Manipulator | 4-Axis (X, Y, Z, θ) UHV-Compatible |
| Charge Neutralization | Electron Flood Gun |
| Cryogenic Capability | Integrated Liquid Nitrogen Cold Trap |
| Vacuum System | Bakeable UHV Chamber with RGA Monitoring |
| Mass Analyzer | Hiden EQS Quadrupole Mass Spectrometer |
| Control & Acquisition Software | MASsoft Operating System with ESM LabVIEW Interface and SIMS Imaging Module |
| Compliance | Designed for GLP/GMP-adjacent surface analysis workflows |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | Multi-Port Sampling Device |
| Valve Configurations | 2-way and 3-way |
| Port Options | 12-, 16-, 18-, or custom-configurable inlet ports |
| Material Options | PTFE- or PEEK-coated valve bodies |
| Application | Automated, sequential vapor/sampling stream selection for real-time analytical systems |
| Compliance | Designed for integration with PTR-MS, SIFT-MS, and other trace gas analyzers |
Show next