| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | Multi-Port Sampling Device |
| Valve Configurations | 2-way and 3-way |
| Port Options | 12-, 16-, 18-, or custom-configurable inlet ports |
| Material Options | PTFE- or PEEK-coated valve bodies |
| Application | Automated, sequential vapor/sampling stream selection for real-time analytical systems |
| Compliance | Designed for integration with PTR-MS, SIFT-MS, and other trace gas analyzers |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | ABR |
| Operating Pressure Range | 0.1–50 bar (configurable) |
| Temperature Control Range | 0–300 °C |
| Temperature Stability | ±0.025 °C |
| Flow Rate Range | 3–1000 mL/min |
| Sample Bed Volume | 2 cm³ (interchangeable) |
| Mass Spectrometer | Hiden DSMS, m/z 1–200 amu, response time ≤200 ms |
| Vacuum Option | UHV pump station (1×10⁻⁸ mbar) |
| Compliance | Fully compatible with GLP/GMP data integrity requirements |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XBS |
| Pricing | Upon Request |
| Ion Source | Crossed-beam, ±35° acceptance angle, 2 mm aperture |
| Detection Limit | 30 ions/s (for molecular beam studies) |
| Mass Range | 0–510 amu |
| Sensitivity | 100% down to 5 ppb |
| Long-term Stability | < ±0.5% peak height drift over 24 h |
| Cooling | Integrated UHV-compatible water-cooled shield |
| Ionization | Tunable electron energy for soft ionization and appearance potential mass spectrometry |
| Signal Enhancement | RF-assisted primary filtering for improved high-mass transmission |
| Interface | RS232, RS485, Ethernet |
| Software | MASsoft™ for Windows® with automated mass list generation and real-time process control |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | Proteus |
| Port Configurations | 20 / 40 / 80 (customizable) |
| Operating Pressure Range | 10 mbar to 2 bar |
| Flow Rate Range | 0.01–10 L/min |
| Actuation | Direct-drive high-torque micro-stepping motor with incremental rotary encoder |
| Positioning Feedback | Closed-loop Z-axis localization |
| Motion Profile | Bidirectional travel with intelligent acceleration/deceleration and endpoint holding |
| Sealing Endurance | >6 × 10⁶ cycles |
| Temperature Control | Integrated heater and sensor, up to 120 °C |
| Dead Volume | Minimized for rapid response |
| Memory Effect | Negligible |
| Compatibility | Designed for seamless integration with HPR20 QMS and other analytical gas systems |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | Nasal Sampling Probe |
| Compatibility | PTR-MS systems |
| Heated | Yes |
| Response Time | < 100 ms |
| Application | Real-time human nasal inhalation monitoring for VOC and odorant analysis |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TPD Workstation |
| Pricing | Available Upon Request |
| Vacuum System | Integrated UHV-compatible pumping station with viewport and programmable sample heating stage |
| Mass Spectrometer | Hiden 3F/PIC triple-filter quadrupole mass spectrometer with pulsed ion counting detection |
| Mass Range | 1–300, 510, or 1000 amu (user-selectable) |
| Data Acquisition Rate | >500 data points/second |
| Maximum Sample Temperature | 1000 °C |
| Automation | Sealed, motorized autosampler |
| Software | Integrated TPD control suite with real-time temperature ramping, peak integration, spectral deconvolution, and time-resolved desorption profiling |