- All
- Favorite
- Popular
- Most rated
| Brand | IONICON Analytik G m.b.H. |
|---|---|
| Origin | Austria |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PTR-TOF QB |
| Detection Principle | Proton-Transfer-Reaction Time-of-Flight Mass Spectrometry (PTR-TOF MS) |
| Instrument Type | Portable |
| Typical Configuration | Multi-Analyte VOC Analyzer |
| Detection Range | C2–C12 Volatile Organic Compounds (VOCs), including aldehydes, ketones, aromatics, terpenes, oxygenates, and sulfur-containing compounds |
| Mass Resolution (m/Δm) | 4000 (FWHM at m/z 200) |
| Accuracy | ±5% relative to certified standard gas mixtures |
| Response Time | <100 ms (10–90% rise time for individual compounds) |
| Brand | IONICON Analytik G.m.b.H. |
|---|---|
| Origin | Austria |
| Model | PTR-TOF 1000 |
| Detection Principle | Proton Transfer Reaction (PTR) coupled with Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Real-Time Analyzer |
| Typical Configuration | Integrated VOC Monitoring System |
| Detection Range | 10 pptv – 1 ppmv |
| Resolution | 1 pptv |
| Accuracy | ±10 pptv |
| Response Time | ≤100 ms |
| Mass Range | 1–10,000 Th |
| Mass Resolving Power | >1500 (m/Δm) |
| Sampling Flow Rate | 50–800 sccm |
| Inlet & Reaction Chamber Heating | 40–180 °C and 40–120 °C respectively |
| Power Supply | 100–230 V AC, max. 1000 W |
| Dimensions (W×H×D) | 60 × 91 × 80 cm |
| Weight | 150 kg |
| Data Interfaces | Ethernet, RS232 |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | PTR3-TOF 10K |
| Detection Principle | Proton Transfer Reaction (PTR) coupled with High-Resolution Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Real-Time Gas Analyzer |
| Configuration | Single-Stream Ambient Air Monitoring System |
| Detection Range | 0.1 pptv – 100 ppbv |
| Mass Resolution | Up to 15,000 m/Δm (FWHM) |
| Accuracy | ±0.001% mass accuracy (calibrated) |
| Response Time | < 100 ms (10–90% step response) |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | PTR-TOF 6000X2 |
| Detection Limit | < 1 pptv |
| Sensitivity | > 2000 cps/ppbv |
| Mass Resolution | > 6000 (m/Δm, FWHM) |
| Ionization Modes | H₃O⁺, NO⁺, O₂⁺, NH₄⁺ |
| Response Time | < 100 ms |
| Ion Optics | ION-BOOSTER ion funnel + hexapole ION-GUIDE |
| Mass Analyzer | high-resolution iTOF (ion time-of-flight) |
| Optional Modules | SRI, Fast GC, AutoSampler (270-position), Multiplexing inlet, CHARON, LCU, BET |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | LCU |
| Configuration Options | LCU-s (Standard), LCU-a (Advanced) |
| Dilution Range | ppt to % (v/v) |
| Output Flow Rate | 0.1–50 L/min (single gas stream) |
| Accuracy | <5% (relative) |
| Response Time | <1 min (for concentration step change, including calculation latency) |
| Humidity Control Range | 10–100% RH @ 40 °C |
| Evaporation Optimization | Dynamic temperature-controlled liquid dosing with real-time vapor pressure compensation |
| Condensation-Free Operation | Integrated heated transfer lines and isothermal vapor path |
| Dimensions (W×H×D) | 35 × 35 × 15 cm |
| Weight | 10 kg |
| Optional LCU-a Enhancements | Dual liquid inlet (second for humidity reference), additional gas inlet with Sulfinet™-coated mixing manifold |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PTR-TOF 4000 |
| Pricing | Upon Request |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BET |
| Pricing | Upon Request |
| Heating Temperature | 70 °C |
| Internal Volume | 40 mL |
| Response Time | < 100 ms |
| Sample Line Length | 2 m |
| Clinical Compliance | ISO/IEC 60601-1 |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | PTR-TOF 10K |
| Detection Principle | Proton-Transfer-Reaction (PTR) Ionization |
| Instrument Type | Online Real-Time Gas Analyzer |
| Configuration | Single-Gas-Stream VOC Analyzer |
| Detection Range | 1 pptv – 100 ppbv |
| Mass Resolution (m/Δm) | ≥10,000–15,000 |
| Accuracy | ±0.001% (relative mass accuracy) |
| Response Time | ≤100 ms |
| Detection Limit | <1 pptv |
| Sensitivity | >1000 cps/ppbv |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Manufacturer | IONICON Analytik GmbH |
| Model | FUSION PTR-TOF 10k |
| Detection Principle | Proton Transfer Reaction (PTR) coupled with Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Real-Time Gas Analyzer |
| Configuration | Single-Source VOC Monitoring System |
| Detection Range | 100 ppqv – 100 ppb |
| Mass Resolution | ≥10,000–15,000 m/Δm (FWHM) |
| Accuracy | ±0.001% of reading (mass axis calibration stability) |
| Response Time | ≤100 ms (90% signal rise time, T90) |
| Limit of Detection | <0.1 pptv (for selected VOCs, e.g., benzene, isoprene) |
| Sensitivity | up to 30,000 cps/ppbv (H₃O⁺ mode, for monoterpenes) |
Show next