| Brand | C-Therm |
|---|---|
| Model | Trident |
| Measurement Principle | Integrated Modified Transient Plane Source (MTPS), Flexible Transient Plane Source (Flex TPS), and Transient Line Source (TLS Needle) |
| Thermal Conductivity Range | 0–2000 W/m·K |
| Accuracy | <5% |
| Repeatability | <1% |
| Operating Temperature Range | –50°C to +500°C |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Compliance | ASTM D7984, ISO 22007-2.2, ASTM D5334, ASTM D5930, IEEE 442, GB/T 32064 |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | XEMIS |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Number of Analysis Stations | 1 |
| Pore Size Measurement Range | < 50 nm |
| Temperature Range | 77 K to 773 K (–196 °C to 500 °C) |
| Pressure Range | Up to 200 bar |
| Analysis Theory | BJH, Langmuir, DFT, t-plot, α<sub>s</sub>-method |
| Balance Capacity | 5 g |
| Balance Resolution | 0.2 µg |
| Long-term Stability | ±5 µg |
| Dynamic Weighing Range | 0–200 mg |
| Construction | All-metal VCR-fitted architecture |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Model | Trident TPS |
| Measurement Principle | Transient Plane Source (TPS) |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | < 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Thermal Diffusivity Range | 0 – 1200 mm²/s |
| Specific Heat Capacity Range | 0 – 5 MJ/m³·K |
| Effusivity Range | 0 – 40,000 W·s⁰·⁵/m²·K |
| Repeatability | < 1% |
| Test Duration | 0.8 – 180 s |
| Compliance | ISO 22007-2:2015, GB/T 32064-2015 |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | MBR |
| Instrument Type | Physical/Chemical Adsorption Analyzer |
| Operating Pressure Range | Up to 10 bar |
| Temperature Range | 120°C to 300°C |
| Flow Configuration Modes | Co-current and Cross-flow |
| Integrated Detection | Close-coupled Quadrupole Mass Spectrometer (QMS) |
| Valve Architecture | Pneumatically Actuated, Ultra-Low-Dead-Volume Switching Valves |
| Control System | Fully Programmable, Automated Sequence Execution |
| Membrane Cell | Precision-Machined, Integral Support Structure |
| Compliance | Designed for ASTM D1434, ISO 15105-1, and ISO 2556 gas permeation test protocols |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XEMIS |
| Pricing Range | USD 130,000–260,000 (FOB) |
| Measurement Principle | Gravimetric Method |
| Temperature Range | 77 K to 773 K (–196 °C to 500 °C) |
| Pressure Range | Ultra-High Vacuum (UHV) to 200 bar |
| Ultimate Vacuum | 1 × 10⁻⁸ Torr |
| Sensitivity | 0.2 µg |
| Long-Term Stability | ±5 µg |
| Maximum Sample Capacity | 5 g |
| Dynamic Weighing Range | 0–200 mg |
| Construction | All-Metal VCR-Sealed Architecture |
| Calibration | Zero-Drift-Free Operation, No In-Situ Re-Zero Required |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IGA100 |
| Pricing | Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Trident |
| Price Range | USD 65,000–105,000 |
| Instrument Type | Transient Plane Source (TPS) / Flexible TPS / Transient Line Source (TLS) |
| Dimensions (L×W×H) | 300 × 300 × 212 mm |
| Accuracy | ±1% |
| Thermal Conductivity Range | 0–500 W/(m·K) |
| Repeatability | High |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Model | Trident MTPS |
| Measurement Principle | Modified Transient Plane Source (MTPS) |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | < 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Repeatability | < 1% |
| Thermal Diffusivity Range | 0 – 1200 mm²/s |
| Specific Heat Capacity Range | 0 – 5 MJ/m³·K |
| Effusivity Range | 0 – 40,000 W·s⁰·⁵/m²·K |
| Test Duration | 0.8 – 180 s |
| Compliance | ISO 22007-2, ASTM D7984, ASTM D5334, ASTM D5930, GB/T 32064 |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HTP1-V |
| Instrument Type | Physical/Chemical Adsorption Analyzer |
| Measurement Principle | Volumetric (Pressure-Step) Method |
| Gas Inlet Ports | 8 |
| Temperature Range | LN₂ (–196 °C) to 500 °C |
| Isothermal Stability | ±0.1 °C |
| Heating Rate | 1–20 °C/min |
| Pressure Range | Ultra-High Vacuum (UHV, <1×10⁻⁹ mbar) to 200 bar (20 MPa) |
| Primary Function | High-Pressure Hydrogen Adsorption/Desorption Characterization |
| Optional Mass Spectrometer | m/z 1–200 amu (300 amu optional), response time <300 ms, quantitative output in ppm/ppb/%, scan speed up to 100 amu/s |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Trident Film |
| Instrument Type | Transient Plane Source (TPS) Method |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | Better than 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Repeatability | Better than 1% |
| Compliance | ISO 22007-2, ASTM D7984, GB/T 32064 |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Model | Flex TPS |
| Measurement Principle | Transient Plane Source (TPS) |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | < 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Repeatability | < 1% |
| Standards Compliance | ASTM D7984, ISO 22007-2.2, GB/T 32064, ASTM D5334, ASTM D5930, IEEE 442 |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | CATLAB |
| Instrument Type | Chemisorption Analyzer / Catalytic Characterization System |
| Temperature Range | −196 °C to 1000 °C (selectable furnace options) |
| Heating Rate | 1–20 °C/min |
| Pressure Range | Ambient (atmospheric) |
| Gas Flow Range | 3–100 mL/min (up to 500 mL/min optional) |
| Mass Range | 1–200 amu (300 amu optional) |
| Response Time | <500 ms |
| Scan Speed | up to 100 amu/s |
| Detection Units | %, ppm, ppb |
| Gas Inlet Channels | 4 standard (8 optional) |
| Catalyst Cartridge System | Interchangeable, thermocouple-integrated |
| Reactor–MS Interface | Dead-volume-free, heated transfer line |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | IGAsorp |
| Measurement Principle | Gravimetric (Microbalance-Based Dynamic Vapor Sorption) |
| Sample Capacity | Up to 4.5 g |
| Minimum Sample Mass | ~1 mg |
| Microbalance Resolution | 0.1 µg (at 100 mg range) |
| Long-Term Stability | ±1 µg/week |
| RH Control Range | 0–95% RH |
| RH Accuracy | ±0.1% RH (control), ±1% RH (0–90% RH), ±2% RH (90–100% RH) |
| RH Response Time | <15 s to 90% of step change |
| RH Ramp Rate | 0.1–100% RH/hour |
| Temperature Range | 5–85 °C (ambient-controlled chamber) |
| Temp Stability | ±0.05–±0.1 °C |
| Carrier Gas | Dry air or N₂ |
| Flow Rate | 100–500 mL/min |
| Humidification Reservoir | 200 mL |
| Sample Holders | Borosilicate glass or stainless-steel mesh crucibles |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | IGA |
| Balance Capacity | 1 g (5 g optional) |
| Sample Mass Range | 0–100 mg (0–200 mg with 5 g balance) |
| Mass Resolution | 0.1 µg (0.2 µg with 5 g balance) |
| Mass Stability | ±1 µg (long-term, static), ±0.1 µg (short-term) |
| Vacuum Base Pressure | <1×10⁻⁶ mbar |
| Maximum Operating Pressure | 10 bar (20 bar optional) |
| Pressure Resolution | 1/16,000 of full scale |
| Pressure Accuracy | ±0.02% of full scale |
| Temperature Range | −270 °C to 1000 °C |
| Temperature Resolution/Accuracy | ±1 °C (Type K thermocouple), ±0.01–0.1 °C (PRT) |
| Temperature Response Time | 0.05 s (Type K), 1 s (PRT) |
| Pressure Vessel Certification | ASME Section VIII Div. 1 / BS 5500 Category III |
| Brand | C-Therm |
|---|---|
| Model | TCi |
| Measurement Principle | Transient Plane Source (TPS) – Multi-Method Platform (MTPS, Flex TPS, Needle TLS) |
| Origin | Canada |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | < 5% |
| Repeatability | < 1% |
| Thermal Conductivity Range | 0–2000 W/m·K |
| Thermal Diffusivity Range | 0–1200 mm²/s |
| Specific Heat Capacity Range | up to 5 MJ/m³·K |
| Effusivity Range | 5–40,000 W·s⁰·⁵/m²·K |
| Standards Compliance | ASTM D7984, ASTM D5334, ASTM D5930, ISO 22007-2.2, GB/T 32064, IEEE 442 |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Model | Trident HotDisk |
| Measurement Principle | Transient Plane Source (TPS) |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | Better than 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Repeatability | Better than 1% |
| Standards Compliance | ISO 22007-2, ASTM D7984, ASTM D5334, ASTM D5930, GB/T 32064 |