BrandIONICON Analytik G m.b.H.
OriginAustria
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPTR-TOF QB
Detection PrincipleProton-Transfer-Reaction Time-of-Flight Mass Spectrometry (PTR-TOF MS)
Instrument TypePortable
Typical ConfigurationMulti-Analyte VOC Analyzer
Detection RangeC2–C12 Volatile Organic Compounds (VOCs), including aldehydes, ketones, aromatics, terpenes, oxygenates, and sulfur-containing compounds
Mass Resolution (m/Δm)4000 (FWHM at m/z 200)
Accuracy±5% relative to certified standard gas mixtures
Response Time<100 ms (10–90% rise time for individual compounds)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIONICON Analytik G.m.b.H.
OriginAustria
ModelPTR-TOF 1000
Detection PrincipleProton Transfer Reaction (PTR) coupled with Time-of-Flight Mass Spectrometry
Instrument TypeOnline Real-Time Analyzer
Typical ConfigurationIntegrated VOC Monitoring System
Detection Range10 pptv – 1 ppmv
Resolution1 pptv
Accuracy±10 pptv
Response Time≤100 ms
Mass Range1–10,000 Th
Mass Resolving Power>1500 (m/Δm)
Sampling Flow Rate50–800 sccm
Inlet & Reaction Chamber Heating40–180 °C and 40–120 °C respectively
Power Supply100–230 V AC, max. 1000 W
Dimensions (W×H×D)60 × 91 × 80 cm
Weight150 kg
Data InterfacesEthernet, RS232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIONICON Analytik GmbH
OriginAustria
ModelPTR3-TOF 10K
Detection PrincipleProton Transfer Reaction (PTR) coupled with High-Resolution Time-of-Flight Mass Spectrometry
Instrument TypeOnline Real-Time Gas Analyzer
ConfigurationSingle-Stream Ambient Air Monitoring System
Detection Range0.1 pptv – 100 ppbv
Mass ResolutionUp to 15,000 m/Δm (FWHM)
Accuracy±0.001% mass accuracy (calibrated)
Response Time< 100 ms (10–90% step response)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIONICON Analytik GmbH
OriginAustria
ModelPTR-TOF 10K
Detection PrincipleProton-Transfer-Reaction (PTR) Ionization
Instrument TypeOnline Real-Time Gas Analyzer
ConfigurationSingle-Gas-Stream VOC Analyzer
Detection Range1 pptv – 100 ppbv
Mass Resolution (m/Δm)≥10,000–15,000
Accuracy±0.001% (relative mass accuracy)
Response Time≤100 ms
Detection Limit<1 pptv
Sensitivity>1000 cps/ppbv
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIONICON Analytik GmbH
OriginAustria
ManufacturerIONICON Analytik GmbH
ModelFUSION PTR-TOF 10k
Detection PrincipleProton Transfer Reaction (PTR) coupled with Time-of-Flight Mass Spectrometry
Instrument TypeOnline Real-Time Gas Analyzer
ConfigurationSingle-Source VOC Monitoring System
Detection Range100 ppqv – 100 ppb
Mass Resolution≥10,000–15,000 m/Δm (FWHM)
Accuracy±0.001% of reading (mass axis calibration stability)
Response Time≤100 ms (90% signal rise time, T90)
Limit of Detection<0.1 pptv (for selected VOCs, e.g., benzene, isoprene)
Sensitivityup to 30,000 cps/ppbv (H₃O⁺ mode, for monoterpenes)