Empowering Scientific Discovery

Beijing Yichenghengda Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDucom
OriginUSA
ModelNoac
Temperature Range0–320 °C
Test Range225–275 °C
Temp. Resolution0.01 °C
Temp. Accuracy±0.1 °C
Temp. RepeatabilityASTM D5800-compliant
Vacuum Control–2 mbar (electronic, continuous)
Pressure Differential20 mmH₂O (auto-regulated)
Vacuum Accuracy±1%
Heating MethodOil Bath (Method A) or Sample-Controlled (Method B)
ComplianceASTM D5800, IP 42
Dimensions40 × 45 × 45 cm (W×D×H)
Weight22 kg
Power220 V ±15%, 50–60 Hz or 115 V ±15%, 60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDucom
ModelDPP
TypeAutomatic Pour Point Tester
OriginUSA
Cooling CapacitySingle-stage to –40°C, Dual-stage to –80°C
Temperature Range–80°C to +80°C
Resolution0.06°C
Accuracy±0.1°C
RepeatabilityCompliant with ASTM D5950, ISO 3016, and IP 441
Temperature SensorClass A PT100
Display12″ TFT/LCD Touchscreen PC
Power Supply220 V ±15% / 50–60 Hz or 115 V ±15% / 60 Hz
Dimensions (W×D×H)66 × 60 × 80 cm
Weight60 kg (max. 6 test heads)
Standards ComplianceASTM D97, D5853, D5950
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDucom
ModelFPT
OriginUSA
CategoryPetroleum Low-Temperature Property Tester
Cooling Range−90 °C to +80 °C
Temperature Resolution0.01 °C
Accuracy±0.1 °C
RepeatabilityCompliant with ASTM D2386, D5972, D7154 and IP 528
Temperature SensorClass A PT100
Cooling SystemFluorocarbon-free dual-stage refrigeration
Detection MethodCoaxial fiber-optic infrared pulse reflection with mirror-enhanced crystal detection
Stirring MechanismMotor-driven triple-brass-coil agitator
Power Supply220 V ±15 %, 50–60 Hz or 115 V ±15 %, 60 Hz
Dimensions (W×D×H)34 × 60 × 80 cm
Weight34 kg
Standards ComplianceASTM D2386, D5972, D7154, D852, D1177, D1655
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDucom
ModelCPP
OriginUSA
TypeIntegrated Dual-Function Petroleum Low-Temperature Property Analyzer
Temperature Range–80 °C to +80 °C
Temperature Resolution0.06 °C
Temperature Accuracy±0.1 °C (PT100 Class A)
Cooling SystemSingle-stage (to –40 °C) or Dual-stage (to –80 °C), CFC-free motor-compressor
Detection MethodsCloud Point — coaxial infrared optical pulse detection
ComplianceASTM D2500, D5771–D5773, D97, D5853, D5950
Power Supply220 V ±15 %, 50–60 Hz or 115 V ±15 %, 60 Hz
Dimensions (W×D×H)66 × 60 × 80 cm
Weight60 kg (max 6-test-head configuration)
Interface12″ integrated high-resolution TFT/LCD touch-panel PC