BrandGamry
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelInterface
Instrument TypeElectrochemical Workstation
Number of ChannelsUp to 16 Independent Channels
Current Range100 pA – 1 A (extendable to 5 A)
Current Accuracy±0.2% of reading or ±5 pA (whichever is greater)
Potential Accuracy±0.2% of full scale
Potentiostatic Range±12 V (±22 V with external booster)
Potential Resolution1 µV
Current Resolution3.3 fA
EIS Frequency Range10 µHz – 1 MHz
Floating Ground ArchitectureYes
Software SuitePWR800, Echem Analyst, Framework™ (with GLP-compliant audit trail and 21 CFR Part 11 support)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGamry
OriginUSA
ModelEIS BOX
Instrument TypeElectrochemical Workstation
Current Range±5 A
Current Resolution20 pA
Potential Accuracy±1 mV
Potentiostatic Range±6 V
AC Impedance Frequency Range10 µHz – 100 kHz
Channel Count8
Dual Electrometer CapabilityYes
Floating Ground ArchitectureYes
Data InterfaceEthernet / USB
Rack Mountable3U, 19-inch standard
Cable Length per Channel3 m
Minimum Measurable Impedance< 10 µΩ
FRA IntegrationBuilt-in Frequency Response Analyzer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGamry
OriginUSA
ModelInterface 5000
Current Range±5 A
Current Resolution< 20 pA
Potential Accuracy1 µV
Potentiostatic Range±6 V
EIS Frequency Range10 µHz – 1 MHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGamry
OriginUSA
ModelReference 600 Plus
Channel ConfigurationMulti-channel workstation
Current Range±600 mA
Current Resolution20 aA
Potential Accuracy±1 µV
Potentiostatic Range±22 V
EIS Frequency Range10 µHz – 5 MHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGamry
OriginUSA
ModelInterface 1010B
Instrument TypePortable Electrochemical Workstation
Current Range±1 A
Current Accuracy±0.2% of reading
Potential Accuracy±4 mV
Potentiostatic Range±12 V
EIS Frequency Range10 µHz – 20 kHz
Electrode Configuration2-, 3-, and 4-electrode systems
IsolationGalvanically isolated floating ground
Weight3 kg (6.6 lbs)
ConnectivityUSB 2.0 (Windows-compatible)
Signal ProcessingDSP-based oversampling for enhanced SNR and capacitance resolution
iR CompensationCurrent-interrupt method with auxiliary I/O support
Expansion I/OAnalog voltage output, analog current output, external trigger input, digital I/O
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGamry
OriginUSA
ModelIMPS/IMVS
Current Range10 nA – 1 A
Current Accuracy±0.3%
Potential Accuracy±0.2%
Potentiostatic Range±12 V
AC Impedance Frequency Range10 µHz – 1 MHz
Instrument TypeElectrochemical Workstation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGamry
OriginUSA
ModelInterface 1000
Current Range100 pA – 1 A
Current Accuracy±0.2% of reading
Potential Accuracy±0.2% of full scale
Potentiostatic Range±12 V
EIS Frequency Range10 µHz – 1 MHz
Potentiostat ArchitectureFloating (True Ground-Independent)
Voltage Compliance±22 V
Potential Resolution1 µV
Current Resolution3.3 fA
Built-in FRAYes, integrated up to 1 MHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGamry
OriginUSA
ModelReference 600
Instrument TypeElectrochemical Workstation
Current Range600 fA – 600 mA
Current Accuracy±10 pA or ±0.3% of reading
Potential Accuracy±1 mV or ±0.2% of range
Potentiostatic Range±22 V
AC Impedance Frequency Range10 µHz – 1 MHz
Potential Resolution1 µV
Current Resolution20 aA
Input Bias Current<5 pA (typ. <2 pA)
Maximum Output Current±600 mA
Cell Voltage Compliance±22 V
Applied Voltage Range±11 V
Sampling Rate300 kS/s
Floating Ground ArchitectureYes
EIS ExcitationDirect Digital Synthesis (DDS) with sub-harmonic sampling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGamry
OriginUSA
ModelInterface 1010E
Instrument TypePotentiostat/Galvanostat/ZRA
Channel ArchitectureMulti-channel, electrically isolated and floating
Current Range10 nA to 10 mA (9 decades)
Current Accuracy±0.2% of reading
Potential Accuracy±4 mV (not ±4.0 V — corrected per industry standard spec)
Potentiostatic Range±10 V
EIS Frequency Range10 µHz to 1 MHz
Input Noise<20 µV RMS (typical, 10 Hz–100 kHz bandwidth)
Weight2.0 kg
PortabilityBenchtop-portable with integrated shielding and battery-compatible operation
ComplianceMeets IEC 61326-1 (EMC), CE, RoHS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGamry
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelInterface Bipotentiostats
Instrument TypeElectrochemical Workstation
Current Range±5 A
Current Resolution5 pA
Potential Accuracy±1 µV
Potentiostatic Range±12 V
EIS Frequency Range10 µHz – 1 MHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGamry
OriginUSA
ModelLPI1010
Instrument TypePortable Electrochemical Workstation Interface
Current Range±10 mA
Current Accuracy±0.2% of reading
Potentiostatic Range±10 V (configurable up to ±100 V or ±1000 V with optional variants)
Voltage Control Modes10 V / 100 V / 1000 V
AC Impedance Frequency Range10 µHz – 1 MHz (measurement bandwidth limited by external power supply or electronic load)
Weight1 kg
Electrode Cable Length1 m
Signal Output/Input InterfaceBNC, ±10 V full-scale
Operating ModesGalvanostatic EIS, Hybrid EIS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGamry
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMegaEIS
Instrument TypeElectrochemical Workstation
Number of ChannelsUp to 1000 simultaneous EIS channels
Current Range±2000 A
Current Accuracy±0.1 % of reading + 0.5 % of range
Potential Accuracy±0.1 % of reading + 0.1 % of range
Potentiostatic Range±1000 V
EIS Frequency Range1 mHz – 100 kHz
Internal Power DissipationUp to 20 kW per module
CoolingWater-cooled
ADC Resolution24-bit (DC), 24-bit @ up to 1.25 MSps (EIS)
Input ProtectionIP20
Rack Mount19-inch modular cabinet
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGamry
OriginUSA
ModelPTC-1020E
Instrument TypeElectrochemical Workstation
Channel CountSingle-Channel
Current Range±20 A
Current Accuracy±0.1% of reading
Potential Accuracy±0.1% of reading
Potentiostatic Range±10 V
EIS Frequency Range1 mHz – 100 kHz
Maximum Power Output500 W
Current Ranges20 mA / 200 mA / 2 A / 20 A (auto-ranging)
EIS Amplitude1–1000 mV (up to 10 A peak current below 1 kHz)
Cooling MethodForced-air
InterfaceUSB 2.0
Software CompatibilityWindows OS, TCP/IP server support, NI LabVIEW drivers available on request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGamry
OriginUSA
ModelReference 3000AE
Current Range3 pA – 3 A
Current Accuracy±0.2% of reading or ±10 pA (whichever is greater)
Potential Accuracy±0.2% of setting range or ±1 mV
Potentiostatic Range±32 V
EIS Frequency Range10 µHz – 1 MHz
Input Impedance>10¹⁴ Ω
Potential Resolution1 µV (high-resolution mode)
Sampling Rate300,000 points/sec
IR CompensationCurrent Interruption & Positive Feedback
Auxiliary Voltage InputsUp to 8-channel serial potentiometry option available
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGamry
OriginUSA
ModelPTC-05100EW
Instrument TypeElectrochemical Workstation
Channel CountSingle-Channel
Current Range±100 A
Current Accuracy±0.1% of reading
Potential Accuracy±0.1% of reading
Potentiostatic Range±5 V
EIS Frequency Range1 mHz – 100 kHz
Maximum Power Output1000 W
Cooling MethodWater-Cooled
InterfaceUSB 2.0
Software CompatibilityWindows OS, TCP/IP Server, NI LabVIEW Drivers