- All
- Favorite
- Popular
- Most rated
| Brand | Gamry |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Interface |
| Instrument Type | Electrochemical Workstation |
| Number of Channels | Up to 16 Independent Channels |
| Current Range | 100 pA – 1 A (extendable to 5 A) |
| Current Accuracy | ±0.2% of reading or ±5 pA (whichever is greater) |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±12 V (±22 V with external booster) |
| Potential Resolution | 1 µV |
| Current Resolution | 3.3 fA |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Floating Ground Architecture | Yes |
| Software Suite | PWR800, Echem Analyst, Framework™ (with GLP-compliant audit trail and 21 CFR Part 11 support) |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | EIS BOX |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±5 A |
| Current Resolution | 20 pA |
| Potential Accuracy | ±1 mV |
| Potentiostatic Range | ±6 V |
| AC Impedance Frequency Range | 10 µHz – 100 kHz |
| Channel Count | 8 |
| Dual Electrometer Capability | Yes |
| Floating Ground Architecture | Yes |
| Data Interface | Ethernet / USB |
| Rack Mountable | 3U, 19-inch standard |
| Cable Length per Channel | 3 m |
| Minimum Measurable Impedance | < 10 µΩ |
| FRA Integration | Built-in Frequency Response Analyzer |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | Interface 5000 |
| Current Range | ±5 A |
| Current Resolution | < 20 pA |
| Potential Accuracy | 1 µV |
| Potentiostatic Range | ±6 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | Reference 600 Plus |
| Channel Configuration | Multi-channel workstation |
| Current Range | ±600 mA |
| Current Resolution | 20 aA |
| Potential Accuracy | ±1 µV |
| Potentiostatic Range | ±22 V |
| EIS Frequency Range | 10 µHz – 5 MHz |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | Interface 1010B |
| Instrument Type | Portable Electrochemical Workstation |
| Current Range | ±1 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±4 mV |
| Potentiostatic Range | ±12 V |
| EIS Frequency Range | 10 µHz – 20 kHz |
| Electrode Configuration | 2-, 3-, and 4-electrode systems |
| Isolation | Galvanically isolated floating ground |
| Weight | 3 kg (6.6 lbs) |
| Connectivity | USB 2.0 (Windows-compatible) |
| Signal Processing | DSP-based oversampling for enhanced SNR and capacitance resolution |
| iR Compensation | Current-interrupt method with auxiliary I/O support |
| Expansion I/O | Analog voltage output, analog current output, external trigger input, digital I/O |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | IMPS/IMVS |
| Current Range | 10 nA – 1 A |
| Current Accuracy | ±0.3% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±12 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Instrument Type | Electrochemical Workstation |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | Interface 1000 |
| Current Range | 100 pA – 1 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±12 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Potentiostat Architecture | Floating (True Ground-Independent) |
| Voltage Compliance | ±22 V |
| Potential Resolution | 1 µV |
| Current Resolution | 3.3 fA |
| Built-in FRA | Yes, integrated up to 1 MHz |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | Reference 600 |
| Instrument Type | Electrochemical Workstation |
| Current Range | 600 fA – 600 mA |
| Current Accuracy | ±10 pA or ±0.3% of reading |
| Potential Accuracy | ±1 mV or ±0.2% of range |
| Potentiostatic Range | ±22 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Potential Resolution | 1 µV |
| Current Resolution | 20 aA |
| Input Bias Current | <5 pA (typ. <2 pA) |
| Maximum Output Current | ±600 mA |
| Cell Voltage Compliance | ±22 V |
| Applied Voltage Range | ±11 V |
| Sampling Rate | 300 kS/s |
| Floating Ground Architecture | Yes |
| EIS Excitation | Direct Digital Synthesis (DDS) with sub-harmonic sampling |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | Interface 1010E |
| Instrument Type | Potentiostat/Galvanostat/ZRA |
| Channel Architecture | Multi-channel, electrically isolated and floating |
| Current Range | 10 nA to 10 mA (9 decades) |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±4 mV (not ±4.0 V — corrected per industry standard spec) |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Input Noise | <20 µV RMS (typical, 10 Hz–100 kHz bandwidth) |
| Weight | 2.0 kg |
| Portability | Benchtop-portable with integrated shielding and battery-compatible operation |
| Compliance | Meets IEC 61326-1 (EMC), CE, RoHS |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Interface Bipotentiostats |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±5 A |
| Current Resolution | 5 pA |
| Potential Accuracy | ±1 µV |
| Potentiostatic Range | ±12 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | LPI1010 |
| Instrument Type | Portable Electrochemical Workstation Interface |
| Current Range | ±10 mA |
| Current Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±10 V (configurable up to ±100 V or ±1000 V with optional variants) |
| Voltage Control Modes | 10 V / 100 V / 1000 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz (measurement bandwidth limited by external power supply or electronic load) |
| Weight | 1 kg |
| Electrode Cable Length | 1 m |
| Signal Output/Input Interface | BNC, ±10 V full-scale |
| Operating Modes | Galvanostatic EIS, Hybrid EIS |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MegaEIS |
| Instrument Type | Electrochemical Workstation |
| Number of Channels | Up to 1000 simultaneous EIS channels |
| Current Range | ±2000 A |
| Current Accuracy | ±0.1 % of reading + 0.5 % of range |
| Potential Accuracy | ±0.1 % of reading + 0.1 % of range |
| Potentiostatic Range | ±1000 V |
| EIS Frequency Range | 1 mHz – 100 kHz |
| Internal Power Dissipation | Up to 20 kW per module |
| Cooling | Water-cooled |
| ADC Resolution | 24-bit (DC), 24-bit @ up to 1.25 MSps (EIS) |
| Input Protection | IP20 |
| Rack Mount | 19-inch modular cabinet |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | PTC-1020E |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±20 A |
| Current Accuracy | ±0.1% of reading |
| Potential Accuracy | ±0.1% of reading |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 1 mHz – 100 kHz |
| Maximum Power Output | 500 W |
| Current Ranges | 20 mA / 200 mA / 2 A / 20 A (auto-ranging) |
| EIS Amplitude | 1–1000 mV (up to 10 A peak current below 1 kHz) |
| Cooling Method | Forced-air |
| Interface | USB 2.0 |
| Software Compatibility | Windows OS, TCP/IP server support, NI LabVIEW drivers available on request |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | Reference 3000AE |
| Current Range | 3 pA – 3 A |
| Current Accuracy | ±0.2% of reading or ±10 pA (whichever is greater) |
| Potential Accuracy | ±0.2% of setting range or ±1 mV |
| Potentiostatic Range | ±32 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Input Impedance | >10¹⁴ Ω |
| Potential Resolution | 1 µV (high-resolution mode) |
| Sampling Rate | 300,000 points/sec |
| IR Compensation | Current Interruption & Positive Feedback |
| Auxiliary Voltage Inputs | Up to 8-channel serial potentiometry option available |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | PTC-05100EW |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±100 A |
| Current Accuracy | ±0.1% of reading |
| Potential Accuracy | ±0.1% of reading |
| Potentiostatic Range | ±5 V |
| EIS Frequency Range | 1 mHz – 100 kHz |
| Maximum Power Output | 1000 W |
| Cooling Method | Water-Cooled |
| Interface | USB 2.0 |
| Software Compatibility | Windows OS, TCP/IP Server, NI LabVIEW Drivers |
Show next