Empowering Scientific Discovery

Beijing Yichenghengda Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEL-Cell
OriginGermany
ModelPAT-Single-Stand
Dimensions (W × D)105 × 113 mm
Height80 mm (standalone), 110 mm (with PAT-Cell installed)
Weight0.56 kg (standalone), 0.96 kg (with PAT-Cell)
MaterialBattery-grade Al (lower plunger), Cu (upper plunger), PP insulator sleeve
Optional current collectorsStainless steel 316L
Electrode configuration2-electrode or 3-electrode (with integrated ring-type reference electrode)
Connectivity4-mm banana sockets or Sub-D hardwired interface
CompatibilityUniversal potentiostats (e.g., Gamry Reference 3000), battery cyclers, and PAT-series test cells
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEL-Cell
OriginGermany
ModelPAT-Chamber
Dimensions (W × D)380 mm × 640 mm
Height (open/closed lid)600 mm / 375 mm
Weight (empty)32 kg
CompatibilityPAT-Core test cells, ECC-PAT-Core cells, PAT-16, PAT-Pressure
Data ChannelsBattery current, battery voltage, half-cell voltage, temperature, single-cell pressure
InterfaceCompatible with standard potentiostats/galvanostats and battery cyclers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEL-Cell
OriginGermany
ModelPAT-Stand-4
Dimensions (W × D)301 × 119 mm
Height84 mm (standalone) / 114 mm (with PAT-Cell mounted)
Weight0.67 kg
CompatibilityUniversal potentiostats/galvanostats (e.g., Gamry Reference 3000), PAT-Core and ECC-PAT-Core cells
Electrical Interface4-mm banana sockets or Sub-D hardwired connector
Environmental SuitabilityCompatible with gloveboxes and environmental chambers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEL-Cell
OriginGermany
ModelECD-3
Displacement Resolution≤50 nm
Measurement Range0–500 µm
Linear Sensor Output±10 V DC
Linearity<0.15% of full scale
Drift≤100 nm/h
Electrolyte Volume Requirement~1 mL
Electrode Diameter10 mm (max thickness: 1.0 mm)
Operating Temperature Range−20 °C to +70 °C
Dimensions (H×W×D)230 × 100 × 110 mm
Weight1.5 kg
Compatible ElectrolytesOrganic (e.g., LiPF₆ in EC/DMC), Aqueous (with Au upgrade kit)
Load on Working ElectrodeFixed 130 g
Housing MaterialPEEK
SealsEPDM
Electrode SeparationFused quartz frit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEL-Cell
OriginGermany
ModelECD-3 Nano
Displacement Resolution≤5 nm
Measurement Range100 µm / 250 µm (selectable)
Linear Accuracy<0.1% of full scale
Output SignalDC voltage, –10 to +10 V
Sensor TypeHigh-precision capacitive transducer
Electrolyte Volume~1 mL (minimum), up to 3 mL
Electrode CompatibilityDisk electrodes up to Ø10 mm × 1.0 mm thickness
Operating Temperature Range–20 °C to +70 °C (with external temperature control)
Dimensions (H×W×D)230 mm × 100 mm × 110 mm
Weight2.5 kg
Load on Working ElectrodeFixed 130 g (adjustable via optional load kit)
Sealing MaterialsPEEK, EPDM, stainless steel 1.4404, or gold-plated components (aqueous-compatible upgrade)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEL-Cell
OriginGermany
ModelPAT-Cell-Press
Pressure Range0–2.5 bar (abs)
Sensor TypeLaser-Welded Piezoresistive Transducer
SealingGlass-to-Metal + Single PE O-Ring
Dimensions (L×W×H)69 mm × 49 mm × 73 mm
Weight0.5 kg
Electrode MaterialsAl (lower plunger), Cu (upper plunger), PP insulator sleeve
Optional Current CollectorsStainless Steel 316L
Output SignalsAnalog ±10 V (pressure, temperature, current, half-cell voltage)
Integrated Data LoggerUSB interface, simultaneous recording of pressure, temperature, cell current, and half-cell potential
ComplianceHelium-leak tested (<1×10⁻⁹ mbar·L/s), battery-grade material certified per ISO 9001 manufacturing controls
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEL-Cell
OriginGermany
ModelECC-PAT-Core
Dimensions90 × 54 × 70 mm (H × W × D)
Electrode Diameter18 mm
Electrolyte Volumeas low as 0.05 cm³
Weight640 g
Separator Diameter18 mm
MaterialBattery-grade Al (lower plunger), Cu (upper plunger), PP (insulation sleeve), optional 316L stainless steel current collectors
Compatible WithAll PAT-series test cells, ECC-Std, ECC-Ref, ECC-Combi, ECC-Air, ECC-DEMS, ECC-Press, ECC-Opto-Std, ECD-o-DL, ECD-2-DL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEL-Cell
OriginGermany
ModelPAT-Tray
Dimensions (W × D)315 mm × 315 mm
Height120 mm (empty) / 148 mm (loaded)
Weight6.9 kg (empty)
Channel Capacity16 (4 × 4 matrix)
Integrated Data LoggerVoltage (half-cell & full-cell), Current, Time, Temperature
CompatibilityGamry Reference 3000, BioLogic VMP-3, Arbin BT2000, and other standard potentiostats/galvanostats
MaterialBattery-grade Al (lower plunger), Cu (upper plunger), PP insulation sleeve
Operating EnvironmentCompatible with Binder KB53 and equivalent climate chambers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEL-Cell
OriginGermany
ModelECC-Ref
Dimensions90 × 54 × 70 mm (H × W × D)
Electrode Diameter18 mm
Electrolyte Volume0.1 mL (min.)
Weight640 g
Construction MaterialsStainless Steel (316L), PEEK, Aluminum (lower plunger), Copper (upper plunger), Polypropylene (PP), PTFE/PE sealing elements
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0