| Brand | ECHO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SDC |
| Configuration | Upright/Inverted Integrated Platform |
| Imaging Modality | Spinning Disk Confocal, Widefield Fluorescence, Super-Resolution (SIM-based) |
| Brand | Evident (formerly Olympus) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | APX100 |
| Configuration | Upright and Inverted Integrated Platform |
| Medical Device Classification | Non-Medical Device |
| Instrument Class | Research-Grade Fluorescence Microscope |
| Imaging Mode | Widefield Fluorescence + Gradient Contrast (GC) Transmitted Light |
| Software Interface | Intuitive, Workflow-Centric GUI with Automated Folder Structuring |
| Navigation System | Smart Sample Navigation with 0.07× Macro Overview Lens |
| Optical Path | Dual-Path (Fluorescence & GC) |
| Spectral Range | DAPI to Cy7 (350–800 nm) |
| Objective Compatibility | UPLXAPO Series (e.g., 4×, 20× APO), Standard Coverslip-Corrected Objectives |
| Brand | Olympus (Evident) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | ES818 |
| Instrument Type | Upright Microscope |
| Compliance | ISO 9001, IEC 61000-6-3, EN 61326-1 |
| Optical Design | Plan Apochromat-Corrected, Infinity-Corrected Optical Path |
| Imaging Sensor | 20 MP CMOS, Global Shutter |
| Color Fidelity | ΔE* < 3 (CIE L*a*b*, vs. sRGB reference) |
| Dynamic Range Control | HDR-enabled real-time tone mapping |
| Wireless Protocol | IEEE 802.11ac + 5G NR optimized for low-latency multicast |
| Software Architecture | Client-server with audit trail logging (FDA 21 CFR Part 11 compliant mode optional) |
| Brand | Evident (formerly Olympus) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SLIDEVIEW VS-M1R |
| Microscope Configuration | Upright/Inverted Hybrid Platform |
| Compliance | CE-IVDR, FDA 510(k)-cleared (Class II), HIPAA-compliant data handling, NIST-traceable calibration support, GLP/GMP-ready audit trail |
| Brand | Evident (formerly Olympus) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SLIDEVIEW VS200 SILA |
| Instrument Type | Upright/Inverted Hybrid Microscope Platform |
| Brand | Evident (formerly Olympus) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | VS200 SILA |
| Medical Device Classification | Non-Medical Device |
| Instrument Class | Research-Grade Fluorescence Microscope |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | FDCS196 with Image Station |
| Microscope Type | Upright Biological Microscope |
| Eyepiece Configuration | Binocular |
| Temperature Range | −195 °C to +125 °C |
| Vacuum Range | down to 10⁻³ mbar |
| Temperature Stability & Accuracy | ±0.01 °C (with 100 Ω Pt sensor, ±0.1 °C absolute accuracy) |
| Heating/Cooling Rate | up to 150 °C/min |
| Optical Aperture Diameter | 1.3 mm |
| Sample X–Y Translation Range | 16 mm |
| Heating Stage Surface Area | 22 mm diameter |
| Minimum Objective/Condenser Working Distance | 4.5 mm / 12.5 mm |
| Cooling Method | Direct cryogen (e.g., liquid nitrogen) cooling of high-conductivity silver heating block |
| Illumination Path | C-mount-compatible transmitted-light optical train |
| Vacuum Monitoring | Pirani gauge integrated |
| Compliance | ISO 9001-certified service and training support |
| Brand | Femtonics |
|---|---|
| Origin | Hungary |
| Model | Smart |
| Microscope Type | Multiphoton (Two-Photon & Three-Photon) Microscope |
| Configuration | Upright, Motorized XYZ-Adjustable Frame |
| Scan Modes | Galvo, Resonant, or Hybrid Scanning |
| Wavelength Range | Visible to Near-Infrared (NIR) |
| Compatibility | In Vivo, Acute Slice, Cell Culture, VR Integration |
| Optional Modules | Multi-Beam Path, FLIM Extension, Epi-Fluorescence Unit, Ex Vivo Chamber, Green LED Vascular Illumination, Bridge Mount, Piezo Objective Positioner, Motorized Tilt Objective Unit |
| Compliance | Designed for GLP/GMP-aligned neuroscience labs |
| Brand | Femtonics |
|---|---|
| Origin | Hungary |
| Model | Atlas |
| Objective Lenses | 16× water immersion, 25× water immersion, 25× multi-immersion |
| Spatial Resolution | X: 450 nm, Y: 450 nm, Z: 2300 nm |
| Scan Speed | 100 kHz point access, 40 fps @ 510×510 px (500×500 µm²), up to 3000 fps in ROI mode |
| Compliance | CE-marked, ISO 13485–aligned design, compatible with GLP/GMP audit trails via optional software modules |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Model | BHP6601 |
| Type | Single-Head Gamma Camera-Based SPECT System |
| Effective Field of View | ≥510 mm × 390 mm |
| Energy Range | 50–400 keV |
| Intrinsic Spatial Resolution | ≤3.8 mm FWHM |
| Maximum Count Rate | ≥140 kcps |
| Intrinsic Uniformity (Differential) | ≤2.2% |
| (Integral) | ≤2.8% |
| Dimensions (System) | 170 × 183 × 200 cm |
| Weight (System) | 1950 kg |
| Patient Table | 266 × 57 × 65 cm, 250 kg |
| Power Cabinet | 43 × 50 × 96 cm, 47 kg |
| Collimator Cart (Single) | 71 × 83 × 124 cm, 180 kg |
| Software | Full-featured, Chinese-language native interface |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BHP6603 |
| Instrument Type | Radionuclide Imaging System |
| Power Supply | 220 V AC ±10%, 50–60 Hz, 8 A, Single-Phase, 1.7 kVA |
| Thermal Dissipation | 5100 kJ/h |
| Operating Temperature | 15–30 °C (59–86 °F), Max Temp. Ramp Rate: ±3 °C/h |
| Relative Humidity | 20–70 % RH |
| System Weight | 1500 kg (3307 lb) |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Origin | Hungary |
| Manufacturer | Mediso Medical Imaging Systems |
| Instrument Type | Nuclear Medicine SPECT Scanner |
| Detector Configuration | Dual-Head, Variable-Angle |
| Acquisition Modes | Planar & Tomographic (SPECT) |
| Key Hardware | Fully Digital High-Resolution Detectors, Integrated Single-Board Electronics, Motorized Collimator Changer, NIR-Based Patient Contour Mapping |
| Field of View (FOV) | ≥530 mm × 390 mm |
| Energy Range | 40–600 keV |
| Intrinsic Spatial Resolution | ≤3.6 mm FWHM |
| Maximum Count Rate | ≥220 kcps |
| Intrinsic Uniformity (Differential/Integral) | ≤1.9% / ≤2.4% |
| Intrinsic Spatial Linearity (Differential/Absolute) | ≤0.18 mm / ≤0.38 mm |
| Gantry Dimensions (L×W×H) | 1160 × 1520 × 1500 mm |
| Total System Weight | 2200 kg |
| Patient Table (L×W×H) | 2000 × 800 × 650 mm |
| Weight | 350 kg |
| Collimator Cart (L×W×H) | 750 × 560 × 1250 mm |
| Weight | 125 kg |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Origin | Japan |
| Model | A12801-01 |
| Mounting | C-mount to C-mount (linear configuration) |
| Input Mount | C-mount (female) |
| Output Mount | C-mount (male) |
| Relay Lens Magnification | 1.0× |
| Field of View (W-VIEW mode) | 13 mm × 6.4 mm |
| Field of View (Bypass mode) | 13 mm × 13 mm |
| Transmission Wavelength Range | 400–800 nm |
| Peak Transmission (Bypass mode) | ≥97% |
| Dichroic Mirror Compatibility | 25.2 mm × 35.6 mm (±0.1 mm, max thickness 2.0 mm) |
| Bandpass Filter Compatibility | Ø25.4 mm (−0/+0.6 mm tolerance, max thickness 6.0 mm) |
| Chromatic Aberration Correction | Integrated achromatizing lens unit for magnification matching between channels |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −10–50 °C |
| Relative Humidity (non-condensing) | ≤70% |
| Mode Switching | Manual dichroic insertion/removal for W-VIEW ↔ Bypass operation |
| Optical Path Geometry | Collinear, symmetric design for upright and inverted microscopes |
| Brand | Hamilton Thorne |
|---|---|
| Origin | USA |
| Model | XYClone |
| Laser Wavelength | 1480 nm (Infrared) |
| Laser Power | 300 mW (Class I) |
| Pulse Duration | 1–3000 µs adjustable |
| Laser Intensity | 1–100% adjustable |
| Objective Magnification | 20× or 40× |
| Imaging System | High-resolution color digital or monochrome analog camera |
| Software Functions | Zona pellucida thickness measurement, embryo/nucleus/laser-hole diameter quantification, statistical reporting, temperature-ring visualization (50–100 °C), image/video capture & export |
| Compatibility | Universal mounting for inverted microscopes |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hyper |
| Instrument Type | Tomographic Imaging System |
| Energy Resolution | 1.4–5.3 mT |
| Spatial Resolution | 100 µm |
| Scan Time | 10 s per volume |
| Field of View (FOV) | 60 mm × 60 mm × 120 mm |
| Sample Capacity | 1 animal |
| Brand | INTOTOBIOTECH |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | Pano One |
| Pricing | Upon Request |
| Brand | INTOTOBIOTECH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Region of Manufacture | Domestic (China) |
| Model | Patho One |
| Pricing | Upon Request |
| Brand | Invitrogen |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | EVOS M3000 |
| Instrument Type | Inverted Microscope |
| Imaging Modes | Brightfield, Phase Contrast, Color, Fluorescence |
| Camera | High-Stability CMOS Sensor |
| Software | Embedded AI-Powered Cell Confluence Analysis Engine |
| Connectivity | Ethernet/Wi-Fi Enabled for Cloud Integration |
| Dimensions | Compact Footprint Optimized for Biosafety Cabinets and CO₂ Incubators |
| Objective Compatibility | EVOS™ Standard Objectives (1.25×–60×) and Filter Cubes |
| Brand | Invitrogen |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | M7000 |
| Instrument Type | Inverted Fluorescence Microscope |
| Excitation Source | Tunable LED Light Cubes |
| Eyepiece Design | Eyepiece-Free Safety Configuration |
| Objective Compatibility | Broad Spectrum of High-Performance Objectives (1.25× to 100×) |
| Fluorescence Detection | Dual-Camera Architecture |
| Illumination System | Next-Generation Power-Adjustable LED Light Cubes |
| Observation Head | Dual-Camera Integrated Optical Path |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | IVIM |
| Price Range | USD 420,000 – 700,000 |
| Instrument Type | Optical In Vivo Imaging System |
| Energy Resolution | 4 keV |
| Scan Resolution | 512 × 512 pixels |
| Frame Rate | 100 fps |
| Field of View | 10 × 10 µm to 100 × 100 mm² |
| Sample Thickness Capacity | 4 mm |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IVM-MS |
| Price Range | USD 420,000 – 700,000 |
| Instrument Type | Optical Imaging System |
| Energy Resolution | 0.2 keV |
| Scan Resolution | 1024 × 1024 pixels |
| Frame Rate | 100 fps |
| Field of View (FOV) | 100 × 100 µm² to 10 × 10 mm² |
| Sample Capacity | 1 animal per imaging session |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IVM-CM |
| Price Range | USD 420,000 – 700,000 |
| Instrument Type | Optical Imaging System |
| Energy Resolution | 0.2 keV |
| Scanning Resolution | 512 × 512 pixels |
| Frame Rate | 100 fps |
| Field of View (FOV) | 100 × 100 µm² to 10 × 10 mm² |
| Sample Capacity | 1 animal per session |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | IVM-M |
| Price Range | USD 420,000 – 700,000 |
| Instrument Type | Optical Imaging System |
| Energy Resolution | 0.2 keV |
| Scanning Resolution | 512 × 512 pixels |
| Frame Rate | 100 fps |
| Field of View (FOV) | 100 × 100 µm² to 10 × 10 mm² |
| Sample Capacity | 1 animal per imaging session |
| Brand | KeChenStarFly |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | LumiFluor AVIS Faye A |
| Instrument Type | Optical In Vivo Imaging System |
| Price Range | USD 70,000 – 700,000 (approx.) |
| Imaging Modalities | Bioluminescence & Fluorescence |
| Brand | KECHENSTARFLY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Plant lumiScreen DIL |
| Price Range | USD 70,000 – 700,000 |
| Brand | KECHENSTARFLY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Plant lumiScreen DIL |
| Price Range | USD 70,000 – 700,000 |
| Brand | KEWLAB |
|---|---|
| Model | BM3200 |
| Type | Upright Biological Microscope |
| Optical Design | Infinity-Corrected Achromatic Objective System |
| Eyepiece | Widefield 10X (Φ22 mm), 30° Inclined Binocular/Triocular Tube |
| Objectives | PL 4X/0.10 (WD 21 mm), PL 10X/0.25 (WD 5.0 mm), PL 40X/0.65 (Spring, WD 0.66 mm), PL 100X/1.25 (Spring, Oil Immersion, WD 0.36 mm) |
| Focusing | Coaxial Fine/Coarse Focus with Tension Adjustment, Minimum Graduation: 2 µm |
| Stage | Double-Layer Mechanical Stage (210 × 140 mm, 75 × 50 mm Travel) |
| Condenser | Abbe Condenser, NA 1.25, Rack-and-Pinion Height Adjustment |
| Illumination | Adjustable 6V/20W Halogen Lamp |
| Filter Set | Blue Filter + Ground Glass |
| Optional Accessories | Phase Contrast Kits, Additional Objectives, Fluorescence Modules, C-Mount Adapters for Digital Cameras |
| Brand | KEYENCE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | BZ-X1000 Series |
| Instrument Type | Inverted Fluorescence Microscope |
| Excitation Source | High-Power LED (24 W / 48 W) |
| Classification | Research-Grade Fluorescence Microscope |
| Objective Lenses | Plan Apochromat 2×, 4×, 10×, 20×, 40×, 60× Oil, 100× Oil |
| Fluorescence Module | 11-Channel Widefield & Optical Sectioning Capability |
| Control Interface | PC-Based Software Control |
| Camera | 2/3″ 10-Megapixel Monochrome CMOS Sensor (Switchable to Color Mode) |
| Focus Mechanism | Motorized Z-Axis with High-Speed Autofocus |
| Stage | Motorized XYZ Precision Stage |
| Fluorescence Filter Sets | Customizable Interference Filter Cubes |
| DIC Compatibility | Not Equipped |
| Condenser | Not Applicable (Integrated Illumination Design) |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | L2800 |
| Price | USD 1,200 (FOB Guangdong) |
| Optical System | Infinity-Corrected Achromatic Plan Objectives |
| Eyepieces | Widefield WF10X (Φ22 mm) |
| Objective Lenses | PL 4X/0.10 (WD 19.8 mm), PL 10X/0.25 (WD 5.0 mm), PL 40X/0.65 (Spring, WD 0.66 mm), PL 100X/1.25 (Spring, Oil Immersion, WD 0.36 mm) |
| Nosepiece | Four-Position Internal Ball-Bearing Turret |
| Stage | Dual-Layer Mechanical Stage (193 × 155 mm, 75 × 50 mm Travel) |
| Condenser | Abbe Condenser NA 1.25 with Vertical Adjustment |
| Filters | Blue Filter + Ground Glass |
| Illumination | High-Power Adjustable White LED (≥12,000 lux at specimen plane) |
| Focusing Mechanism | Coaxial Coarse/Fine Focus (Fine Focus Graduation: 2 µm, Locking & Upper/Lower Limit Stops) |
| Tube | Trinocular, 30° Inclined |
| Brand | Laite |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | BX-UVBGY-E |
| Instrument Type | Upright Research-Grade Fluorescence Microscope Module |
| Excitation Source | High-Power LED (3 W / 5 W / 10 W) |
| Control Mode | Motorized (Electric) |
| Filter Configuration | Integrated LED-Based Filter Cube Assembly |
| Standard Filter Sets | DAPI, GFP/FITC, TRITC/Cy3, mCherry, Cy5 |
| Optional Filters | Custom excitation/emission band selection available |
| Thermal Management | Active Air-Cooled Heat Sink |
| Software Interface | RS232/USB Protocol Support for External Control and Synchronization |
| Regulatory Status | Not a Medical Device |
| Compliance | Designed for GLP-compliant laboratory environments |