ChemTron
Filter
Showing 181–210 of 283 results
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | RACK GC |
| Output Flow Rate | 1.8–15.0 L/min |
| Hydrocarbon & CO Content | < 0.1 ppm |
| Inlet Pressure Range | 4.5–10 bar |
| Power Supply | 110–120 V / 60 Hz or 220–240 V / 50 Hz |
| Certifications | CE, CSA, FCC |
| Dimensions | 19-inch rack-mount (483 × 450 × 133 mm) |
| Weight | 15 kg |
| Max. Inlet CO | 50 ppm |
| Max. Inlet HC | 100 ppm |
| Max. Inlet Temperature | 40 °C |
| Outlet Temperature | Ambient + 15 °C |
| Pressure Drop | < 1 bar |
| Inlet Port | 1/4" NPT |
| Outlet Port | 1/8" NPT |
| Power Consumption | 200 W (GC 1800) / 550 W (GC 5000, GC 10000, GC 15000) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | RACK-NM Plus Series (100–1350 mL/min) |
| Hydrogen Generation Principle | Proton Exchange Membrane (PEM) Electrolysis of Ultrapure Water |
| Output Flow Rate | 100–1350 mL/min |
| Output Pressure | 11 bar (160 psig) |
| Hydrogen Purity | 99.99996% |
| Water Reservoir Capacity | 5 L |
| Internal Gas Volume | <50 mL |
| Power Consumption | 90–500 W (model-dependent) |
| Dimensions (W×D×H) | 140 × 580 × 490 mm |
| Weight | 19–24 kg |
| Noise Level | ≤46 dB(A) |
| Display | 128×64-pixel LCD with tactile buttons |
| Gas Outlet | 1/8" Swagelock |
| Water Resistivity Requirement | ≥5 MΩ·cm (min. 1 MΩ·cm acceptable) |
| Certifications | CE, CSA, FCC |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | 19" RACK-NM Plus |
| Purity | 99.99996% H₂ |
| Max Flow Rate | 100–1350 mL/min (model-dependent) |
| Max Output Pressure | 11 bar (160 psig) |
| Pressure Accuracy | ±0.1 bar (±5%) |
| Internal Gas Volume | <50 mL |
| Water Reservoir Capacity | 5 L |
| Feed Water Resistivity Requirement | ≥1 MΩ·cm (recommended ≥5 MΩ·cm) |
| Display | 128×64-pixel LCD touchscreen with physical keys |
| Gas Outlet | 1/8" Swagelock |
| Noise Level | ≤46 dB(A) |
| Dimensions (W×D×H) | 140×580×490 mm |
| Weight | 19–24 kg (model-dependent) |
| Power Input | 110–120 V / 60 Hz or 220–240 V / 50 Hz |
| Operating Environment | 15–40 °C, 0–80% RH (non-condensing) |
| Certifications | CE, CSA, FCC |
| Electrolysis Technology | CPEM (Platinum- and Platinum-Iridium-coated Proton Exchange Membrane) |
| Electrolyzer Housing Material | High-purity titanium (CCELL) |
| Drying Technology | Static membrane-based secondary purification + dual cold-regenerative tertiary purifier (RACK-NM series only) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | RACK-PG Plus |
| Purity | 99.9996% (standard), 99.99996% (optional) |
| Max Flow | 100–600 mL/min |
| Max Pressure | 11 bar (160 psig) |
| Pressure Accuracy | ±0.1 bar (±5%) |
| Gas Volume in System | <50 mL |
| Water Resistivity Requirement | ≥1 MΩ·cm (recommended ≥5 MΩ·cm) |
| Power Consumption | 65–250 W |
| Noise Level | ≤46 dB(A) |
| Dimensions | 19″ rack-mount (483 × 500 × 350 mm, H×W×D) |
| Weight | 17–19 kg |
| Certifications | CE, CSA, FCC |
| Operating Environment | 15–40 °C, 0–80% RH (non-condensing) |
| Display | 128×64-pixel LCD with tactile buttons |
| Gas Outlet | 1/8″ Swagelock |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | RACK-PG Plus |
| Hydrogen Generation Principle | Proton Exchange Membrane (PEM) Electrolysis of Deionized Water |
| Output Pressure | 11 bar (160 psig) |
| Hydrogen Purity | 99.9996% |
| Flow Rate Options | 100–600 mL/min |
| Internal Gas Volume | <50 mL |
| Power Consumption | 65–250 W |
| Noise Level | ≤46 dB(A) |
| Dimensions | 19-inch Rack-Mountable (483 × 500 × 600 mm typical) |
| Weight | 17–19 kg |
| Water Resistivity Requirement | ≥1 MΩ·cm (recommended ≥5 MΩ·cm) |
| Certifications | CE, CSA, FCC |
| Display | 128×64-pixel LCD with tactile buttons |
| Gas Outlet | 1/8" Swagelock® |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | RB-2 |
| Temperature Range | −80 °C to +130 °C |
| Temperature Uniformity | ±1 °C |
| Maximum Sample Positions | >60 |
| Module Types | Heating-only, Heating-Cooling, Reflux |
| Brand | ChemTron |
|---|---|
| Origin | Italy |
| Model | RFOZNO |
| Type | Reference Electrolyte Solution (Ag/AgCl-free) |
| Volume Options | 125 mL, 500 mL |
| Compliance | ISO 3696 Grade 2, ASTM E200-22, NIST-traceable pH certification available per batch |
| Packaging | Amber glass bottles with PTFE-lined caps |
| Shelf Life | 24 months unopened, 6 months after opening (stored at 15–25 °C, protected from light and CO₂) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | RPV-1 |
| Instrument Type | Benchtop Fixed-Position System |
| Operating Environment | Ambient Temperature |
| Compliance | ASTM D445, D789, D1243, D4603 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | RT3 |
| Instrument Type | Constant-Temperature Circulating Bath |
| Circulation Mode | Internal & External |
| Temperature Control | Dual-Mode (Heating & Refrigeration) |
| Bath Volume | 4–6 L |
| Temperature Range | −20 °C to +100 °C |
| Temperature Stability | ±0.05 °C |
| Heating Power | 1.5 kW |
| Pump Flow Rate | 10 L/min |
| Pump Pressure | 0.23 bar |
| Refrigerant | R134a (CFC-free) |
| Bath Opening / Depth | 12 × 11 / 15 cm |
| Dimensions (W × D × H) | 22 × 42 × 64 cm |
| Weight | 24 kg |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | RUV-2 |
| Instrument Type | Benchtop Fixed-Position Viscometer |
| Application Environment | Ambient Laboratory Conditions |
| Kinematic Viscosity Range | 1 – 1000 mm²/s (cSt) |
| Temperature Range | 40 – 100 °C |
| Temperature Stability | ±0.01 °C |
| Capillary Type | ASTM Ubbelohde Viscometers (ISO 17025-calibrated) |
| Measurement Positions | 2 |
| Solvent Cleaning & Vacuum Drying | Integrated |
| Power Supply | 100–240 VAC, Max 600 W |
| Dimensions (W × L × H) | 395 × 590 × 580 mm |
| Weight | 75 kg |
| Interfaces | RS232, USB, VGA |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | SC2-60F-0806D1-CL |
| Compliance | EN 14470-1:2004, EN 1363-1 |
| Fire Resistance Rating | 60 min |
| Max Internal Temp Rise Limit | ≤180 °C |
| Auto-Closure Trigger Temp | 50 °C (door), 70–100 °C (vents) |
| Load Capacity per Shelf | 80 kg |
| Shelf Thickness | 30 mm |
| Internal Volume | 89 L |
| Internal Dimensions (W×D×H) | 505 × 419 × 422 mm |
| External Dimensions (W×D×H) | 600 × 610 × 820 mm |
| Weight | 106 kg |
| Shelf Material Options | PP, stainless steel, corrosion-resistant coated steel |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | SC3-30F-1912D2-C |
| Compliance | EN 14470-1:2004, EN 1363-1 |
| Fire Resistance Rating | 30 min |
| Internal Volume | 802 L |
| Internal Dimensions (W×D×H) | 968 × 507 × 1635 mm |
| External Dimensions (W×D×H) | 1101 × 630 × 1951 mm |
| Shelf Capacity | 3 standard / up to 5 shelves |
| Max. Load per Shelf | 80 kg |
| Shelf Thickness | 30 mm |
| Self-Closing Mechanism Activation | 50 °C |
| Vent Closure Temperature | 70–100 °C |
| Weight | 330 kg |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | SC3-90F-1912D2-C / SC3-90F-0812D2D-C |
| Fire Resistance Rating | 90 min (EN 14470-1:2004) |
| Internal Temperature Limit | ≤180 °C during fire exposure |
| Auto-Closing Mechanism | Door seals at 50 °C, ventilation shutters close at 70–100 °C |
| Construction | Welded steel frame with double-walled insulation |
| Shelf Load Capacity | up to 80 kg per shelf |
| Internal Volume | up to 763 L (vertical), 244 L (horizontal) |
| Compliance | EN 1363-1, EN 14470-1, DIN 4102-1 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | SCAN Viscometer |
| Instrument Type | Portable Capillary Viscometer |
| Compliance | ISO 5351 (Pulp Viscosity) |
| Operating Environment | Ambient Temperature |
| Application | Manual Viscosity Measurement of Cellulosic Pulps |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ScienceLine A 1180 |
| Electrode Type | pH Glass Indicator Electrode |
| Body Material | Borosilicate Glass (Ø12 mm) |
| Sensing Membrane | Spherical Bulb |
| Zero Point | pH 7.0 ± 0.3 |
| pH Range | 0–14 |
| Temperature Range | 0–80 °C |
| Connection | L 1 A Cable |
| Interface | Standard Threaded Connector (DIN 19217) |
| Compliance | ISO 3696 Class 3 water compatibility, ASTM E70, DIN 19265 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ScienceLine A 161 1M-DIN-ID |
| Electrode Type | Combination pH/temperature sensor |
| Reference System | Silamid® |
| Body Material | Glass |
| pH Range | 0–14 |
| Zero Point | pH 7.0 ± 0.3 |
| Filling Solution | 3 mol/L KCl |
| Temperature Sensor | Pt1000 |
| Sensing Membrane Shape | Spherical |
| Junction Type | Platinum wire (A-5) |
| Temperature Range | –5 to +100 °C |
| Connector | DIN 19262 + 4-mm pin, with automatic electrode ID recognition |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ScienceLine A 157 |
| Electrode Type | pH Combination Electrode |
| Reference System | Silamid Ag/AgCl |
| Electrode Body Material | Glass (L39 variant: Polypropylene) |
| Zero Point | pH 7.0 ± 0.3 |
| Filling Solution | 3 mol/L KCl (L8880 variant: Referid electrolyte) |
| Sensing Membrane Type | A |
| Connector | SMEK threaded (optional: LS1 ANN, DIN, BNC) |
| Sensing Element Geometry | Cylindrical |
| Temperature Range | –5 to +100 °C |
| pH Measurement Range | 0–14 |
| Membrane Material | Platinum-doped glass |
| Diaphragm Material | Ceramic (standard), porous polyethylene (L8880), or fiber (L39) |
| Integrated Temperature Sensor | Pt1000 (models marked “1M-ID”) |
| Auto-ID Recognition | Yes (DIN/BNC-ID variants) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ScienceLine A7780 |
| Electrode Type | pH Combination Electrode |
| Reference System | Silamid® |
| Body Material | Glass |
| Zero Point | pH 7.0 ± 0.3 |
| Filling Electrolyte | KCl 3 mol/L (Gel) |
| Sensing Membrane Shape | Spherical |
| pH Range | 0–14 |
| Temperature Range | –5 °C to +80 °C |
| Junction Type | Ceramic |
| Shaft Diameter | 12 mm |
| Length | 120 mm |
| Connector | Standard Threaded (BNC/DIN compatible via adapter) |
| Compliance | ISO 3696, ASTM D1193 (Type II water for calibration), GLP-ready documentation support |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ScienceLine Ag 42 A |
| Electrode Type | Reference and Working Electrodes for Electrochemical Analysis |
| Temperature Range | −5 to +100 °C (Pt 6140: +10 to +40 °C) |
| Reference System | Silamid® Ag/AgCl |
| Electrode Body Material | Glass |
| Electrolyte | KCl 3 mol/L |
| Junction Type | Ceramic Frit |
| Sensor Geometry | Cap-type (Ag), Rod-type (Pt), Ring-type (Pt), or Disc-type (Au/Pt) |
| Diameter Options | 5 mm (Ag), 1–6 mm (Pt/Au), 12 mm (body) |
| Length Options | 103–170 mm |
| Connector Options | DIN, BNC, or Standard Threaded (M8×0.75 or L1A) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ScienceLine B 2220+ |
| Electrode Type | Single-Reference Electrode |
| Body Material | Glass |
| Reference System | Ag/AgCl (3 mol/L KCl) |
| Temperature Range | −5 °C to +100 °C |
| pH Range | 0–14 |
| Junction Type | Double-Liquid-Junction |
| Sensing Element | Platinum |
| Connection | L 1 N Cable |
| Compliance | ASTM D1129, ISO 7888, USP <798>, GLP-ready configuration |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ScienceLine LF 213 T |
| Cell Constant | 0.01 cm⁻¹ |
| Electrode Material | Stainless Steel Ring |
| Temperature Sensor | NTC 30 kΩ |
| Operating Temp. Range | 0–100 °C |
| Conductivity Range | 0.03–1000 µS/cm |
| Electrode Body Diameter | 12 mm |
| Cable Length | 1.5 m |
| Housing | Stainless Steel |
| Compliance | ASTM D1125, ISO 7888, USP <645>, EN 27888 |
| Features | Integrated Flow-Through Cell, Fixed Connector |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ScienceLine NH 1100 |
| Electrode Type | Amperometric Ammonia ISE (Composite) |
| Body Material | Plastic (12 mm diameter) |
| Connection | SMEK threaded fitting, optional L1A cable |
| Membrane | Replaceable gas-permeable membrane |
| Temperature Range | +5 °C to +50 °C |
| Measurement Range | 0.1–1,000 mg/L NH₃-N |
| Compliance | Designed for ASTM D1426, ISO 5667-3, and EN 25814 water quality applications |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | SD15-100 |
| Instrument Type | Magnetic Stirrer |
| Max. Stirring Volume per Position | 1–400 mL |
| Speed Range | 100–2000 rpm |
| Temperature Range | 0–200 °C |
| Heating Power | 1000 W |
| Stirring Power per Position | 40 W |
| Position Count | 15 |
| Inter-Position Spacing | 65 mm |
| Well Diameter/Depth | 57.5 × 48 mm |
| Power Setting Levels | 25 / 50 / 75 / 100 % (4-step) |
| Protection Rating | IP20 |
| Operating Environment | −10 to +40 °C at ≤80% RH |
| Dimensions (W×D×H) | 295 × 445 × 110 mm |
| Weight | ~23 kg |
| Ordering Code (incl. Control Unit) | 63100 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | SES |
| Temperature Range | RT +5 to 450 °C |
| Power | 125–290 W (model-dependent) |
| Flask Capacity | 300, 500, or 1000 mL |
| Extractor Tube Dimensions | 45 mm ID × 130 mm H |
| Sintered Glass Porosity | 20–35 µm or 100–200 µm |
| Configuration | 3-position or 6-position modular heating block with independent temperature control per position |
| Display | Dual LED readout (setpoint & actual temperature, 0.1 °C resolution) |
| Vessel Compatibility | Flat-bottom and round-bottom flasks |
| Solvent Recovery | Integrated reflux condensation and closed-loop solvent recycling |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | SG15 / SG30 |
| Heating Power | 18 kW (SG15) / 48 kW (SG30) |
| Rated Steam Output | 0.025 t/h (SG15) / 0.065 t/h (SG30) |
| Rated Working Pressure | 0.7 MPa |
| Rated Steam Temperature | 171 °C |
| Water Capacity | 24 L (SG15) / 29 L (SG30) |
| Voltage | 380 V |
| Compliance | China Special Equipment Manufacturing License (Pressure Vessel & Boiler) |
| Optional | Soft Water Treatment Unit |
| Control | PLC-based Steam Temperature Regulation Module (customizable for external process integration) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Product Type | Capillary Viscometer |
| Instrument Category | Kinematic & Dynamic Viscosity Measurement |
| Compliance | UKAS-accredited calibration, ISO/IEC 17025, ASTM D446, ASTM D2171, ISO 3105, IP 71 Part 2, BS 188, EN 12596 |
| Models | 1638 (Shell Reverse Flow), 1647 (Cannon-Ubbelohde), 1659 (Cannon-Manning Semi-Micro), 1677 (Asphalt Institute Vacuum), 1678 (Modified Koppers Vacuum), 1676 (Cannon-Manning Vacuum) |
| Kinematic Viscosity Range | 0.0036–300,000 mm²/s |
| Dynamic Viscosity Range | 4.2–580,000 Pa·s |
| Operating Environment | Ambient temperature (20–25 °C), laboratory benchtop use |
| Calibration | Individually UKAS-certified with traceable K-value (mm²/s)²/s and documented uncertainty budgets |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Smart |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Speed Range | 0.3–100 rpm |
| Speed Steps | 18 |
| Viscosity Accuracy | ±1% of full scale |
| Repeatability | ±2% of full scale |
| Display Resolution | 0.01–1 cP |
| Compliance | ASTM D2196, ISO 2555, ISO 3219, USP <911> |
| Data Interface | USB-B |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | SMT |
| Max Operating Temperature | 650°C |
| Power Range | 230–483 W |
| Bottle Capacity Range | 100–22,000 mL |
| Max Flask Diameter | 60–347 mm |
| External Diameter | 159–483 mm |
| External Height | 121–254 mm |
| Weight | 1.0–11.1 kg |
| Standard Cable | 1.2 m, 3-conductor with locking plug |
| Optional Accessories | Splash Ring, Upper-Neck Heating Sleeve, Full Protective Cover |
| Recommended Controller | PL524 Pro / PL524 Pre |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | SO₂ Titration Analyzer |
| Measurement Range | 1–300 mg/L |
| Repeatability | ±6 mg/L (Total SO₂), ±2 mg/L (Free SO₂) |
| Analysis Time (excl. distillation) | 4–5 min (Total SO₂), 2–3 min (Free SO₂) |
| Standard Configuration | Main unit, glass reaction vessel, drying valve, three 300 mL Erlenmeyer flasks, two magnetic stir bars, ten titration tips, reagent kit, and operator manual |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | SPG |
| Capacity | 12–200 L |
| Vessel Material | Borosilicate Glass 3.3 (DIN ISO 3585) |
| Maximum Operating Pressure | Up to 6 bar (g) |
| Vacuum Rating | Down to -0.9 bar (absolute) |
| Jacket Type | Double-walled glass jacket for heating/cooling media |
| Standard Flange Interface | ISO-KF / DIN 28178 (ground-glass joints: 45/50, 24/40, DN200/DN300/DN400) |
| Stirring Options | Digital-controlled high-torque drive (up to 120 N·cm) or AC motor drive |
| Optional Thermal Management | Multi-channel oil circulation unit with independent temperature control per port |
| Structural Frame | Modular stainless steel support frame with leveling feet and integrated utility routing |