ChemTron
Filter
Showing 91–120 of 283 results
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Compression Principle | Piston-Type |
| Flow Rate | 0–40 L/min |
| Maximum Pressure | 0–9.5 bar |
| Dew Point | ≤3 °C (standard operation), down to –15 °C with integrated dryer |
| Particle Filtration | ≤0.01 µm (0.01 micrometer) |
| Oil & Water Content | Oil-free, <0.1 ppm total hydrocarbons |
| Tank Material | Stainless Steel (AISI 304) |
| Noise Level | 63 dB(A) |
| Power | 600 W |
| Tank Volume | 40 L |
| Dimensions (L×W×H) | 640 × 470 × 720 mm |
| Weight | 72 kg |
| Safety Compliance | Spring-loaded pressure relief valve (activates at >10 bar), thermal cut-off switch, digital pressure controller with adjustable start/stop setpoints |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | GHS120L |
| Flow Rate | 120 L/min |
| Maximum Pressure | 10 bar (145 psi) |
| Motor Power | 1.5 kW |
| Noise Level | 53 dB(A) |
| Oil Content Class | ISO 8573-1 Class 0 (Certified Oil-Free) |
| Motor Efficiency Class | IE3 |
| Control Mode | Start/Stop |
| Weight | 120 kg |
| Dimensions (W×D×H) | 1025 × 690 × 840 mm |
| Inlet/Outlet Port | G1/2" F |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Glass Filtration Reactor |
| Vessel Capacity | 6 L |
| Construction Material | Borosilicate Glass 3.3 (DIN ISO 3585) |
| Maximum Operating Pressure | 25 bar (gauge) |
| Vacuum Rating | ≤ 0.1 mbar (absolute) |
| Filtration Interface | ACE SAFE™ Threaded or Standard Ground-Glass Joint |
| Temperature Control | Jacketed (Dual-Zone: Reaction + Filtration Zone) |
| Drive System | Top-Mounted Digital Stirrer with Mechanical Seal |
| Compliance | CE, PED 2014/68/EU, ISO 9001 Certified Manufacturing Support |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | GPR |
| Vessel Capacity | 0.5–5 L (standard) |
| Operating Pressure | 2.4–3.1 bar (GPR-M1–M4: 2.4 bar |
| GPR-M5–M8 | 3.1 bar) |
| Vacuum Range | -0.7 to -0.9 bar (i.e., absolute pressure 0.3–0.1 bar) |
| Construction Material | High-purity borosilicate glass 3.3 (DIN ISO 3585) |
| Sealing System | ACE-Thrend® precision glass-threaded joints with fluorocarbon O-rings |
| Temperature Range (with JULABO integration) | -50 °C to +200 °C |
| Vessel Type | Split-body or monolithic (one-piece) design |
| Safety Package | Integrated pressure gauge, adjustable relief valve, and certified rupture disc |
| Compliance | Designed per PED 2014/68/EU Annex I essential safety requirements for Category I pressure equipment |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | GSA |
| Density Measurement Range | 0.9000–1.0500 g/cm³ |
| Particle Size Range | 0.001–0.1 mm |
| Sample Capacity | 12 simultaneous measurements |
| Temperature Compensation | Automatic, based on Stokes’ law |
| Repeatability | < 2% RSD |
| Compliance | ASTM D422, ISO/TS 17892-4 |
| Programmable Parameters | Soil density, gravitational acceleration, data acquisition interval, sedimentation duration |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | GT1500 |
| Output Flow Rate | 1.5 L/min |
| Hydrocarbon (HC) & CO Content | < 0.05 ppm |
| CO₂ Content | < 1 ppm |
| NOₓ & SOₓ Content | < 0.1 ppm |
| Inlet Air Pressure Range | 4.5–10 bar |
| Power Supply | 110–120 V / 60 Hz or 220–240 V / 50 Hz |
| Power Consumption | 220 W |
| Dimensions (H×W×D) | 410 × 550 × 250 mm |
| Weight | 10 kg |
| Certifications | CE, CSA, FCC |
| Inlet/Outlet Fitting | 1/4" compression fitting (standard), optional 1/8" compression outlet |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Drive Type | Electromagnetic |
| Models | GXLa 1608 / GXLa 1612 / GXLa 1020 |
| Max. Pressure | 10 bar |
| Flow Range | 7–15 L/h |
| Stroke Volume (theoretical) | 0.6–1.25 mL/stroke |
| Max. Stroke Frequency | 200 strokes/min |
| Nominal Port Diameter | 8 × 5 mm / 8 × 5 mm / 12 × 9 mm |
| Suction Lift | 1.8 mWS |
| Diaphragm Head | Self-venting, bypass-free |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | H-SAFE |
| Detection Range | 0–1000 ppm H₂ |
| Display Resolution | 1 ppm |
| Output Signals | 4–20 mA + RS485 + 2 Relay Outputs |
| Power Supply | 24 VDC |
| Enclosure Rating | IP66 |
| Explosion Protection | Ex d II CT6 |
| Operating Temperature | −30 °C to +55 °C |
| Humidity Range | 10–95% RH (non-condensing) |
| Integrated Temperature & Humidity Sensing | −40 °C to +80 °C / 0–100% RH |
| Data Logging | Operation Log, Alarm Log, Over-Temperature Event Log, Over-Range Event Log |
| Alert Functions | Sensor Fault, Output Failure, Over-Range Usage, Sensor Lifetime Warning, Calibration Due Reminder, Over-Temperature Warning |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | HandyLab 200 |
| Portability | Portable |
| Application | Laboratory |
| TDS Range | 0–1999 mg/L, 0–199.9 g/L |
| Resistivity Range | 1.000 Ω·cm – 199.9 MΩ·cm |
| Salinity Range | 0.0–70.0 (IOT) |
| Temperature Range | −5.0–+105.0 °C |
| Conductivity Range | 0.000–1999 mS/cm (with K=0.01, 0.1, 1.0 cm⁻¹ electrodes) |
| Accuracy | ±0.5% of reading (typical) |
| Data Storage | 200 manual entries |
| IP Rating | IP67 |
| Display | Backlit monochrome LCD |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | HandyLab 600 |
| pH Range | -0.000–14.000, ±0.004 pH |
| mV Range | -1200.0–+1200.0 mV, ±0.2 mV |
| Temperature Range | -5.0–+105.0 °C, ±0.2 °C |
| Data Storage | 500 manual + 5,000 automatic datasets |
| Calibration | 1–5 points, with 22 built-in standard buffer sets |
| Display | Backlit monochrome LCD |
| Interface | USB-B (Mini) |
| Ingress Protection | IP67 |
| Power | Rechargeable battery operation |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | HandyLab 680 |
| IP Rating | IP67 |
| Electrode Interface | IDS Digital Signal |
| Channels | Dual-channel (simultaneous measurement) |
| pH Range & Accuracy | –0.000 to 14.000, ±0.004 pH |
| mV Range & Accuracy | –1200.0 to +1200.0 mV, ±0.2 mV |
| Conductivity Range & Accuracy | 0.00 to 2000 mS/cm, ±0.5% of mean value |
| Resistivity Range & Accuracy | 0.00 Ω·cm to 100 MΩ·cm, ±0.5% of mean value |
| Salinity Range & Accuracy | 0.0 to 70.0 ppt (IOT), ±0.5% of mean value |
| TDS Range & Accuracy | 0 to 1999 mg/L or 0 to 199.9 g/L, ±0.5% of mean value |
| Temperature Range & Accuracy | –5.0 to +105.0 °C, ±0.2 °C |
| Dissolved Oxygen (DO) Range & Accuracy | 0.00 to 20.00 mg/L, ±0.5% of reading |
| Oxygen Saturation Range & Accuracy | 0.0 to 200.0%, ±0.5% of reading |
| Oxygen Partial Pressure Range & Accuracy | 0 to 400 hPa, ±0.5% of reading |
| Calibration | 1–5 point, 22 preconfigured buffer sets |
| CMC (Continuous Measurement Control) | Yes |
| QSC (Quality Sensor Check) | Yes |
| Data Storage | 500 manual + 10,000 automatic datasets |
| User Management | Role-based access control |
| Connectivity | USB-B (Mini-B) and USB-A ports |
| Power | Rechargeable battery (operational without external power) |
| Display | Backlit high-contrast LCD |
| Brand | ChemTron |
|---|---|
| Origin | Switzerland |
| Model | HKH2-250 Plus |
| Hydrogen Generation Principle | Proton Exchange Membrane (PEM) Electrolysis of Deionized Water |
| Output Flow Rate | 250 mL/min |
| Output Pressure | 7 bar (105 psig) |
| Hydrogen Purity | 99.99996% |
| Power Consumption | 140 W |
| Water Reservoir Capacity | 2.5 L (2 L usable) |
| Internal Gas Volume | < 50 mL |
| Dimensions (W×D×H) | 230 × 370 × 507 mm |
| Weight | 13 kg |
| Noise Level | ≤ 46 dB(A) |
| Display | 128×64-pixel LCD with tactile buttons |
| Input Water Resistivity | ≥ 1 MΩ·cm (recommended ≥ 5 MΩ·cm) |
| Certifications | CE, CSA, FCC |
| Operating Environment | 15–40 °C, 0–80% RH (non-condensing) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | HP PLUS RACK |
| Nitrogen Generation Principle | CPSA (Compressed Pressure Swing Adsorption) |
| Output Flow Rate | 500 mL/min |
| Output Pressure | 5 bar (75 psig) ±0.05 bar |
| Nitrogen Purity | 99.999% |
| Dew Point | < −50 °C |
| Power Consumption | 270 W |
| Noise Level | 46 dB(A) |
| Dimensions | 19″ W × 3U H × 500 mm D |
| Input Air Requirements | 7–10 bar, oil-free and dry air per ISO 8573-1:2010 Class 1.2.1 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | HR / HRT |
| Vessel Capacity | 9 mL to 1850 mL |
| Construction Material | Borosilicate Glass (with optional epoxy-coated variant) & Stainless Steel Frame |
| Operating Pressure Range | Up to 4–10 bar (60 psig) |
| Temperature Control Range | Ambient to 80 °C |
| Oscillation Drive | Electric or Pneumatic Motor |
| Safety Certification | NEC Class I, Group D |
| Sealing Interface | ACE-THRED™ precision threaded connection |
| Vacuum Compatibility | Yes (via integrated vacuum line interface) |
| Control Interface | TFT touchscreen with real-time display of oscillation speed, pressure, and temperature |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | HSP240-AH / HSP240-H / HSP240-AR / HSP240-R |
| Stirrer Type | Magnetic Stirrer |
| Speed Range | 100–1500 rpm |
| Temperature Range | 50–450 °C |
| Max. Set Temperature (ceramic-glass) | 450 °C |
| Max. Set Temperature (aluminum-ceramic enamel) | 320 °C |
| External PT100 Support | Yes |
| Temperature Stability (with PT100) | ±2 °C |
| Safety Temp. Range | 50–500 °C (adjustable) |
| Over-Temp. Protection Range | 10–50 °C (adjustable) |
| Heating Power | 800 W |
| Display | LCD |
| Interface | USB |
| Timer Range | 1–1999 min or continuous |
| Heater Surface | SCHOTT® ceramic glass (H/R models) or aluminum-ceramic enamel (AH/AR models) |
| Heater Dimensions | 180 × 180 mm (AH/H) or Ø135 mm (AR/R) |
| Dimensions (W×H×D) | 225 × 215 × 115 mm |
| Power Supply | 220 V / 50 Hz |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | HV |
| Hydrogen Generation Principle | Proton Exchange Membrane (PEM) Electrolysis of Deionized Water |
| Output Pressure | 1.0–20 bar (15–290 psi) |
| Hydrogen Purity | 99.9999% (with PSA), 99.95% (without PSA) |
| Dew Point | −78°C (with PSA), −30°C (without PSA) |
| Feed Water Conductivity Requirement | <1 µS/cm (ASTM Type I), recommended <0.2 µS/cm (ASTM Type III) |
| Power Consumption | 1.7–6.4 kW |
| Dimensions (W×H×D) | 496×846×880 mm |
| Weight | 109–190 kg |
| Operating Temperature | 10–35°C |
| Noise Level | <72 dB(A) |
| Ingress Protection | IP20 |
| Communication Interface | RS-232 / Ethernet (optional) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | HyCo |
| Operating Principle | Thermally Driven Metal Hydride Hydrogen Compression |
| Max Output Pressure | 200 bar (2900 psi) |
| Adjustable Outlet Pressure Range | 10–200 bar |
| Standby Pressure | Near Ambient |
| Pressurization Time to 200 bar | < 6 min |
| Storage Capacity Options | 90 Nℓ (HYCO110) or 180 Nℓ (HYCO120) |
| Max Flow Rate | 800 NmL/min (HYCO110) or 1600 NmL/min (HYCO120) |
| Dimensions (Standard Unit) | 483 × 461 × 133 mm |
| Dimensions (MPRE200 Regulator) | 483 × 461 × 89 mm |
| Purity | >99.9999% H₂ (ultra-high-purity, O₂ and moisture removed via selective metal hydride absorption) |
| Maintenance-Free Operation | Yes |
| Noise Level | <45 dB(A) |
| Compliance | CE-marked |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Hydrom 070 |
| Instrument Type | Density Gradient Tube System |
| Portability | Portable |
| Sample Type | Liquids |
| Temperature Range | 20–60 °C |
| Compliance | Designed for ASTM D1298, ISO 3675 & ISO 12185 compliant density determination |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Type | pH Combination Electrode |
| pH Range | 0–14 |
| Temperature Range | −5 to 100 °C |
| Reference System | Iodine/Iodide |
| Zero Point | pH 7.00 ± 0.25 |
| Shaft Material | Glass |
| Membrane Resistance | 200–400 MΩ |
| Junction Types | Platinum or Ceramic |
| Membrane Shape | Spherical, Cylindrical, or Spear-shaped |
| Connector Options | DIN, BNC, S7 Thread, Metrohm (R-type), BNC+Cinch, DIN+baa, BNC+baa, Metrohm+2baa |
| Integrated Temperature Sensor | Pt1000 (standard), NTC30 (select models) |
| Auto-ID Recognition | Yes (for compatible meters) |
| Compliance | Designed for GLP/GMP-compliant workflows |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ISP-1, ISP-2, ISP-1HD |
| Application | Polymer, pulp, and HDPE/PP sample preparation for rotational rheometry and capillary viscometry |
| Compliance | Designed for GLP-compliant workflows with audit-trail-ready data transfer to RPV-1 viscosity software |
| Safety | Integrated self-diagnostic routines and real-time error detection |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | JU4S-A-01 to JU4S-A-15 |
| Temperature Range | -20 °C to +200 °C |
| Bath Volume | 5 L to 200 L |
| Construction Material | AISI 304 stainless steel (custom S316 or PTFE-coated options available) |
| Circulation Type | Internal and external recirculation |
| Temperature Control Mode | Refrigeration & heating dual-function |
| Compliance | Designed for compatibility with JULABO temperature controllers |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | JU4S-D-01 / JU4S-D-02 / JU4S-D-03 |
| Temperature Range | -70 °C to +150 °C (model-dependent) |
| Bath Volume | ≤40 L (JU4S-D-01/D-02), 2.1 L (JU4S-D-03) |
| Circulation | Internal & External |
| Temperature Control | Refrigeration & Heating |
| Construction | Borosilicate Glass + Stainless Steel |
| Insulation | High-Vacuum Double-Glazed Window |
| Compliance | CE, RoHS, EN 61000-6-3, EN 61000-6-2 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | JU4S-E-01 to JU4S-E-07 |
| Bath Volume | ≤50 L |
| Temperature Range | Ambient to +65 °C |
| Circulation Type | Internal & External |
| Bath Material | Acrylic (JU4S-E-01–E-04) or Borosilicate Glass (JU4S-E-05–E-07) |
| Compatible Controllers | JULABO CD, DD, MX Series |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | JUS4S-B-01 / JUS4S-B-02 / JUS4S-B-03 |
| Bath Volume | ≤30 L / ≤60 L / ≤90 L |
| Temperature Range | −40 °C to +200 °C (JUS4S-B-01 & B-02), −40 °C to +150 °C (JUS4S-B-03) |
| Jacket Pressure Rating | ≤4 bar |
| Bath Material | 316L Stainless Steel |
| Circulation Type | Internal & External |
| Temperature Control Mode | Refrigeration & Heating Combined |
| Compliance | Designed for GLP-compliant laboratories, compatible with JULABO high/low-temperature circulation units |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | KALTGAS TG-RD |
| Vessel Capacity | 2 L (1.5 L usable) |
| Temperature Range | −170 °C to +120 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Medium | Liquid Nitrogen (LN₂) |
| LN₂ Consumption | 2.2–22 L/h |
| Vaporization Heater Power | 500 W |
| Heating Power | 400 W |
| Pressure Rating | High-Pressure Compatible |
| Construction Materials | V2A Stainless Steel Tubing (1.5 m flexible), Aluminum Frame |
| Interface | KF NW 50 LN₂ Tank Connection |
| Compliance | Designed for GLP/GMP-aligned lab environments, compatible with ASTM E2869 and ISO 17025 traceability frameworks |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | KALTGAS |
| Temperature Range | −170 °C to +120 °C |
| Temperature Stability | ±0.1 °C (standard configuration) / ±0.2 °C (typical systems I–VI) |
| LN₂ Evaporator Power | 500 W or 1000 W (Jet-type) |
| Heater Power | 400 W to 630 W |
| LN₂ Consumption | 0.8 L/h to 22 L/h |
| Cryogenic N₂ Delivery Line | V2A stainless steel, 1.5–1.8 m, flexible, vacuum-insulated |
| Connection to LN₂ Dewar | KF NW 50 |
| Reactor Vessel | 2 L total / 1.5 L usable volume, vacuum-jacketed with sight strip |
| Reactor Lid | Three NS 29/32 ports (central + two lateral) |
| Frame Material | Anodized aluminum |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | KRC540 |
| Instrument Type | Upright |
| Capacity | 540 L |
| Operating Temperature Range | −2 °C to +12 °C |
| Temperature Stability | ±1 °C |
| Display Resolution | 0.1 °C |
| Refrigeration System | Compressor-based |
| Refrigerant | R134a |
| Control Type | Digital LED Controller |
| External Dimensions (W×L×H) | 92 × 71 × 153 cm |
| Internal Dimensions (W×L×H) | 70 × 60 × 135 cm |
| Safety Features | Intrinsically Safe Internal Cavity, Externally Mounted Control Circuitry, Door Lock, Overload-Protected Compressor, Self-Test Function for Alarm Verification |
| Optional Accessories | ATEX-certified compact bottle-top dispenser, explosion-proof digital probe thermometer with data logging capability |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Lab 855 |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter |
| Measurement Precision | 0.001 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.1 pH |
| pH Range | –2.000 to 19.999 |
| pH Accuracy | ±0.005 pH (at 25 °C, calibrated) |
| mV Range | ±1200.0 mV / ±2000 mV |
| mV Accuracy | ±0.3 mV / ±1 mV |
| Temperature Range | –5.0 to 105.0 °C |
| Temperature Accuracy | ±0.1 °C |
| Calibration Points | 1–3 point automatic or manual |
| Auto-Read Function | Yes |
| Temperature Compensation | Automatic & Manual |
| Calibration Memory | 1 set stored |
| Data Storage Capacity | 500 or 5000 readings (configurable) |
| Display | LCD |
| Electrode Interface | DIN |
| Connectivity | Mini USB-B |
| Compliance | GLP/AQS compliant |
| Power Supply | AC adapter or battery operation |
| CMC Detection | Supported |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Lab 865 |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter |
| pH Accuracy | ±0.1 pH (range –2.0 to 20.0) / ±0.01 pH (range –2.00 to 20.00) / ±0.005 pH (range –2.000 to 19.999) |
| pH Resolution | 0.001 pH |
| mV Accuracy | ±0.3 mV (±1200.0 mV range) / ±1 mV (±2500 mV range) |
| Temperature Accuracy | ±0.1 °C (–5.0 to 105.0 °C) |
| Temperature Compensation | Automatic or Manual |
| Calibration Points | Up to 5-point pH, 2- to 7-point ISE |
| Calibration Memory | 10 calibrations |
| Calibration Timer | Built-in |
| Data Storage | 500 or 5000 readings* |
| Communication Interface | Mini USB-B |
| GLP/AQS Compliance | Yes |
| Display | Graphic monochrome backlit LCD |
| Electrode Interface | DIN |
| Power Supply | AC adapter or battery operation |
| CMC Measurement | Supported |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Lab 875 / Lab 875P |
| Measurement Parameters | pH, mV, Dissolved Oxygen (DO) Saturation & Concentration & Partial Pressure, Conductivity, Resistivity, Salinity, TDS, Temperature |
| Electrode Compatibility | IDS (Intelligent Digital Sensor) electrodes |
| pH Calibration Points | 1–5 |
| DO Calibration | 1-point (air saturation or zero) |
| Conductivity Calibration | 1-point |
| Calibration Records Stored | ≤10 sets |
| Calibration Timer | 1–999 days |
| Data Storage | 500 manual + 4,500 automatic entries |
| Temperature Compensation | Automatic for all parameters except ORP |
| GLP/AQS Compliance | Yes |
| Printer Support | External printer (Lab 875P includes integrated thermal printer) |
| Communication Interface | Mini USB-B |
| Power Supply | 4 × 1.5 V AA batteries or AC adapter |
| Additional Features | CMC (Continuous Measurement Control), QSC (Quick Sensor Check) |
| Software Export Format | CSV |