Generic
Filter
Showing 4351–4380 of 5714 results
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TMES 1/2 |
| Pricing | Upon Request |
| Fiber Optic Core | Acrylic |
| Pixel Count | TMES 1: 3,500 |
| TMES 2 | 7,400 |
| Fiber Diameter | TMES 1: 35 mm |
| TMES 2 | 13 mm |
| Max Fiber Damage Tolerance | TMES 1: ≤2% |
| TMES 2 | ≤0.5% |
| Cable Material | SUS304 stainless steel braid with PVC jacket |
| Minimum Bend Radius | 40 mm |
| Cable Length | TMES 1: 1 m |
| TMES 2 | 3 m |
| Cable Diameter | TMES 1: 8 mm |
| TMES 2 | 5 mm |
| Light Source | 3.5 V, 0.7 A, 2.55 W LED-equivalent incandescent |
| Power Supply | 3 × C (LR14) alkaline batteries |
| Viewing Direction | Straight-ahead |
| Field of View | TMES 1: 60° |
| TMES 2 | 55° |
| Fixed Focus Distance | 10 mm |
| Waterproof Rating | Objective lens and fiber cable rated for 1–1.3 bar air pressure (IP65 equivalent for probe section) |
| Operating Temperature | −20 °C to +60 °C |
| Total Weight | 1,135 g |
| Packaging Dimensions | 360 × 270 × 80 mm |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | TMST 3 |
| Price | Upon Request |
| Frequency Response | 30 Hz – 15 kHz |
| Power Supply | 4 × AAA (R03) batteries, up to 30 hours continuous operation |
| Operating Temperature | −10 °C to +45 °C |
| Maximum Audio Output | 250 mV |
| Headset Dimensions | 220 × 40 × 40 mm |
| Probe Lengths | 70 mm and 220 mm |
| Total Weight | 1560 g |
| Handheld Sensor Weight | 162 g |
| Headset Weight | 250 g |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TMTI 2 |
| Pricing | Available Upon Request |
| Field of View | 20° × 15° |
| Detector Resolution | 160 × 120 uncooled microbolometer |
| Spectral Range | 8–14 µm |
| Thermal Sensitivity (NETD) | ≤0.15 °C at 25 °C |
| Temperature Range | −10 °C to +250 °C |
| Accuracy | ±2 °C or ±2% of reading (whichever is greater) |
| Minimum Focus Distance | 30 cm |
| Focus | Manual |
| Laser Targeting | Integrated Class II laser pointer for center-point indication |
| Display | 3.5″ LCD with LED backlight, 4 color palettes (Iron Red, Rainbow, Grayscale, High-Contrast) |
| Storage | Removable SD card (up to 1 GB), supports ≥1000 thermal images |
| Battery | Rechargeable Li-ion, 4 h continuous operation |
| Power Supply | 12 V AC adapter included |
| Interface | USB Type-B |
| Dimensions | 230 mm × 120 mm × 110 mm |
| Weight | 0.75 kg (with battery) |
| Housing | Shock-resistant engineering plastic |
| Emissivity Adjustment | 0.20–1.00 in 0.01 increments |
| Measurement Tools | Dual movable crosshairs, ΔT (delta-T) calculation |
| Mounting | Handheld or tripod-compatible (1/4″–20 UNC thread) |
| Operating Ambient | −15 °C to +45 °C, 10–90% RH non-condensing |
| Storage Ambient | −20 °C to +70 °C |
| Included Accessories | TMTI 2 imager, rechargeable battery, 12 V AC charger, 128 MB SD card, USB card reader + cable, lens dust cap, power connector, software CD (user manual + PC reporting suite), carrying strap, protective carry case |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | SKMBT |
| Pricing | Available Upon Request |
| Origin | United Kingdom |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Handheld Spectral Radiometer |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Skye Mini Tensiometer |
| Price | Upon Request |
| Ceramic Tip Length | 25 mm |
| Diameter | 13.5 mm |
| Cable Length | 3 m |
| Measurement Range | 0–850 mbar |
| Tube Length Options | 10, 20, 30, 40, 50 cm |
| Stability | ±0.1% of reading per year |
| Data Logger Compatibility | SKT 660/I Handheld Reader or SDL 5000 Series (1–8 channels) |
| Reader Memory Capacity | 1200 readings |
| Reader Sampling Interval | 1 min – 2 hr |
| Reader Operating Temperature | −20 °C to +70 °C |
| Reader Power | Rechargeable or alkaline batteries (60 hr / 120 hr typical field life) |
| Data Logger Resolution | 15-bit |
| Data Logger Sampling Interval | 10 s – 12 hr |
| Data Output | ASCII via RS232C |
| Data Logger Operating Temperature | −20 °C to +70 °C |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKZ Series Universal |
| Pricing | Available Upon Request |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SKZ-1000B |
| Price Range | USD 140–1,400 (FOB) |
| Maximum Test Load | 10 kN |
| Load Application Rate | 5–700 N/s (digitally adjustable) |
| Platen Spacing | 100 mm |
| Platen Dimensions | 1000 × 1000 mm |
| Specimen Size Range | 50 × 60 mm to 1000 × 1000 mm |
| Load Measurement Accuracy | ±0.5% of full scale |
| Power Supply | 220 V AC, 0.8 kW |
| Loading Mode | Constant-rate motor-driven displacement control with real-time digital speed display |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Model | SL-2 |
| Pricing | Available Upon Request |
| Temperature Range | 0–10 °C |
| Interior Volume | 800 L |
| Interior Dimensions (W×D×H) | 760 × 660 × 1700 mm |
| Exterior Dimensions (W×D×H) | 870 × 770 × 1950 mm |
| Shelf Size | 550 × 350 mm |
| Construction | Stainless Steel Interior |
| Door | Dual-pane Transparent Glass with Lock |
| Cooling System | Imported Hermetic Refrigeration Unit |
| Safety Features | Over-temperature & Differential-Temperature Alarm, Automatic Low-Temperature Cut-off |
| Optional | RS-232 Serial Interface, UV Germicidal Lamp, Internal Power Outlets, Adjustable Load-Bearing Shelves, Two Chromatography Column Mounting Rods, LED Interior Lighting, Casters for Mobility |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SL-2 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | SL10 |
| Pricing | Upon Request |
| Sealing Temperature Range | Ambient to 400 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Accuracy | ±0.15 °C |
| Temperature Control Stability | ±0.2 °C |
| Sealing Pressure Range | 5–700 psi (34.5–4830 kPa) |
| Pressure Resolution | 1 psi (7 kPa) |
| Sealing Time Range | 100 ms to 99 s |
| Time Resolution | 10 ms |
| Time Accuracy | ±1 ms |
| Time Repeatability | ±2 ms |
| Dual Load Cells (Left/Right) | Combined Capacity 362 kg (1000 lbf), Accuracy ≤0.09 kg (0.2 lbf), Repeatability ≤0.09 kg (0.2 lbf), Calibrated per ASTM E4 |
| Peel Load Cell | 11.34 kg (25 lbf) capacity, 0.1% FS accuracy, ASTM E4 calibrated |
| Seal Jaw Length Options | 50.8 mm (2 in) for hot tack or 127 mm (5 in) with auto-feed turntable |
| Jaw Width Options | 6.35–25.4 mm (0.25–1.00 in) |
| Jaw Surface Configurations | Flat, Grooved, Custom, or Standard Geometric Profiles |
| Power Supply | 230 V / 50 Hz |
| Compressed Air Requirement | 80–120 psi (recommended 90 psi), integrated pressure switch |
| Dimensions (W×D×H) | 584.2 × 508 × 794 mm |
| Weight | 79.3 kg |
| Rated Pressure | 80 kN |
|---|---|
| Working Platform Diameter | φ82 mm |
| Top–Bottom Platform Travel | 0–80 mm |
| Maximum Stroke | 40 mm |
| Column Spacing | 115 mm |
| Dimensions (L×W×H) | 340 × 225 × 330 mm |
| Net Weight | 30 kg |
| Power | 500 W |
| Supply Voltage | AC 220 V, 50/60 Hz |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SL3500 |
| Price | Upon Request |
| Light Output at 12.7 cm | Up to 3,000 µmol(photon)·m⁻²·s⁻¹ |
| Spectral Options | Cool White, Warm White, Deep Blue (447 nm), Red-Orange (617 nm), RGB (627/530/447 nm), Far-Red (optional) |
| Temporal Resolution | Down to 100 µs pulse width |
| Control Modes | Manual keypad, External controller, PC-based Light Studio software |
| LED Lifetime | ≥50,000 h (6–7 years typical operation) |
| Cooling | Integrated active thermal management |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SLC-ON |
| Instrument Type | Online Continuous Monitoring System |
| Power Supply | 220 VAC (20 W) or Optional Solar Power |
| Dimensions | 170 × 280 × 230 mm (H × W × D) |
| Weight | 30 kg |
| Enclosure | Anodized Aluminum Alloy Housing |
| Detection Targets | Gaseous Odorous Compounds |
| Sensor Capacity | Up to 9 Integrated Sensors (MOS, Electrochemical for S/N-compounds, PID) |
| Accuracy | ≤3% RSD |
| Sampling Cycle | 1–5 min (configurable) |
| Data Storage | 1 GB SD Card (internal) |
| Display | Touchscreen LCD, 114 × 64 mm |
| Environmental Parameters Measured | Temperature, Relative Humidity (optional) |
| Output | OU (Odor Unit), OI (Odor Intensity), Gas Identification & Quantification |
| Built-in Features | Temperature-Controlled Sensor Chamber, Vibrating Armature Pump (long-life), Auto-Restart After Power Failure |
| Connectivity | Wired (RS-485/Ethernet) and Wireless (LTE/LoRaWAN) Transmission Options |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SLC-OP |
| Instrument Type | Portable |
| Sensor Configuration | 5-channel (Electrochemical NH₃/H₂S, PID for TVOC, MOS for amine/odor, dual-range odor sensor) |
| Measurement Outputs | Odor Unit (OU), ppm |
| Accuracy | ≤3% RSD |
| Detection Cycle | 1–5 min (user-configurable) |
| Display | 114 × 64 mm resistive touchscreen LCD |
| Power | Rechargeable Li-ion battery (2 h continuous operation) or 220 VAC adapter |
| Dimensions | 170 × 280 × 230 mm (H×W×D) |
| Weight | 10 kg |
| Enclosure | Anodized aluminum alloy |
| Data Storage | 1 GB SD card + RS-232 interface |
| Origin | Poland |
|---|---|
| Type | Forced-Air Incubator |
| Model | ST1200 |
| Temperature Range | +3°C to +70°C |
| Temperature Uniformity | ±0.3°C |
| Humidity Range | 20–65% RH |
| Chamber Capacity | 1365 L |
| Power Supply | Not specified |
| Compliance | CE, IEC 61010-1 |
| Origin | Europe |
|---|---|
| Detector Type | Back-Illuminated CCD Array (1044 × 64 pixels, 24 µm × 24 µm) |
| Spectral Range | 200–980 nm |
| Optical Resolution (FWHM) | 3–4 nm |
| Wavelength Accuracy | < 0.5 nm |
| Repeatability | < 0.1 nm |
| Thermal Drift | < 0.01 nm/K |
| Stray Light | 0.1% @ 340 nm (Xe lamp) |
| Integration Time | 1 ms to several minutes |
| Acquisition Rate | Up to 100 spectra/s (16-bit digitization) |
| Input Interface | Removable SMA-905 connector (Ø0.5 mm, NA = 0.22) |
| Slit Dimensions | 70 µm × 1400 µm |
| Grating | Flat-field corrected holographic grating |
| Pixel Dispersion | ~0.8 nm/pixel |
| Flash Detection Capability | 10 µs – 10 ms transient events |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 51392 |
| Pricing | Upon Request |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | SMART 3.0 |
| Price | USD 14,000 (approx.) |
| [Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | F680 |
| Price Range | USD 140 – 700] |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SMART I/O |
| Price | USD 13,800 (FOB) |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CS 250/300_5_3, CS 250/300_5_2.4, CS 250/200_7_4.2, CS 250/200_7_3.4 |
| Max Photosynthetic Photon Flux Density (PPFD) | 250 µmol·m⁻²·s⁻¹ (at 30 cm or 20 cm, depending on model) |
| LED Panel Area | 100×60 cm² or 80×60 cm² |
| Shelf Layers | 5 or 7 |
| Total Cultivation Area | 3–4.2 m² |
| External Dimensions (W×D×H) | 106×65×220 cm or 86×65×220 cm |
| Weight | 75–85 kg |
| Power Consumption | 300–1200 W |
| Light Spectrum | White + Far-Red (customizable with Red, Blue, etc.) |
| LC200 Controller Capacity | Up to 16 Racks |
| Control Resolution | Second-level timing precision |
| Optional Modules | Chlorophyll Fluorescence Monitoring (Ft, QY, OJIP) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SMART NanoFab |
| Pricing | Upon Request |
| Source Capacity | 4 or 8 effusion cells / e-beam sources |
| Integrated In-situ Monitors | RHEED, QCM, Linear Beam Flux Monitor |
| Growth Modes | Thermal Evaporation, E-beam Evaporation, RF Plasma, Pulsed Laser Deposition (PLD), Sputtering, Gas-Phase Precursor Delivery |
| Compatible Materials | III–V (e.g., GaAs, InP), II–VI (e.g., CdTe, ZnSe), II–Oxides (e.g., ZnO), III–Nitrides (e.g., GaN, AlN), and other compound semiconductors |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Smart |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Smart SpectroTM |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QJICWQ |
| Price | USD 6,300 (FOB Shanghai) |
| Dimensions (L×W×H) | 670 × 380 × 220 mm |
| Weight | 70 kg |
| Power Supply | AC 220 V ±5%, 50/60 Hz |
| Rated Power | 35 W |
| Bending Speed | 29 rpm |
| Twist Angle | 15° ±1° (bidirectional) |
| Cycle Range | 1–9999 programmable cycles |
| Compliance | GB/T 16649.1–2022, ISO/IEC 7816-1:2014, ISO/IEC 7816-2:2014, EN 1546-1:2017 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SmartCART |
| Pricing | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SMARTCHEM 140 |
| Pricing | Available Upon Request |
| [Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Smartchem 200 |
| Product Type | Discrete Flow Analyzer |
| Measurement Speed | 200 samples/hr |
| Sample Capacity | 5 racks × 126 positions |
| Reaction Temperature | 37.2 °C ± 0.1 °C |
| Optical Range | 420–880 nm |
| Absorbance Linearity | 0.001–2.500 AUFS |
| Resolution | 0.0001 Abs |
| Minimum Reaction Volume | 300 µL |
| Pipetting Range | 3–450 µL |
| Dilution Factor | Up to 100× |
| Reagent Positions | 16 (10 refrigerated + 6 ambient) |
| Standard Positions | 10 |
| Diluent Positions | 2 |
| Filter Wheel | 9 optical filters + 1 blank filter |
| Reaction Cuvettes | 60-position rotating disc, semi-reusable, auto-cleaned and QC-verified |
| Compliance | ASTM, ISO, AOAC, US EPA Method 353.2 (NO₃⁻/NO₂⁻), AFNOR, COFRAC, BATF, USEPA] |
| [Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Smartchem 300 |
| Pricing | Available Upon Request |
| Analysis Types | End-point, Kinetic, Differential, Dual-wavelength, Fixed-time |
| Reagent Positions | Up to 72 positions with refrigeration (4 movable racks × 16 slots + 8 fixed slots |
| Sample Positions | 4 universal sample carousels (15 positions each for cups or tubes Ø10–16 mm × 40–100 mm H) |
| Throughput | Up to 450 samples/h (with ISE module), 300 samples/h (photometric only) |
| Photometer | Dual-channel, direct-read, 9-position auto-select narrow-band interference filters (340–880 nm), 6 V/10 W halogen lamp, 6 mm pathlength, linear range 0.001–4.200 Abs, resolution 0.0001 Abs |
| Minimum Reaction Volume | 200 µL |
| Sample/Reagent Dispensing | Capacitive microdispenser, 3.0 µL–330 µL (1 µL increment), 37 °C reagent preheating, integrated probe washing, on-board dilution capability |
| Reaction Cuvettes | 80 reusable quartz/glass cuvettes across 4 independent rotating carousels (20 per carousel), automated cleaning with selectable acidic/alkaline/neutral wash solutions, temperature control at 37 °C ± 0.3 °C |
| Nitrate/Nitrite Module | Fully compliant with US EPA Method 353.2 |
| Optional ISE Module | Direct potentiometric measurement of Na⁺, K⁺, Cl⁻, Li⁺ (140 samples/h) |
| Barcode Scanning | Optional reagent and sample tube barcode readers |
| Compliance | ISO, AOAC, BATF, US EPA, AFNOR, COFRAC] |