Generic
Filter
Showing 1081–1110 of 5685 results
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 110P |
| Quotation | Upon Request |
| Vessel Diameter Range | >60 µm |
| Axial Alignment | Manual X/Y/Z Adjustment |
| Bath Volume | Up to 10 mL (3 mL Standard) |
| Bath Material | Acid-Resistant Stainless Steel |
| Tension Range | ±50 mN |
| Tension Resolution | 0.01 mN |
| Pressure Range | 0–250 mmHg |
| Pressure Resolution | 0.1 mmHg |
| Temperature Control | Built-in Electronic Feedback Heating |
| Temp Range | Ambient to 50 °C |
| Temp Accuracy | ±0.1 °C |
| Analog Output | 1.0 V F.S. (12-bit) |
| Digital Interface | RS232 / RS485 |
| Power Input | 100–240 VAC, Auto-Switching, 50/60 Hz |
| Environmental Operating Range | 15–30 °C |
| Optional Modules | Flowmeter (15–1500 µL/min), pH Meter (0–14, 0–50 °C), Peristaltic Pump (2.5–50 rpm) |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DMT 110P |
| Pricing | Upon Request |
| [Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 111P |
| Price | Upon Request |
| Vessel Diameter Range | >60 µm |
| Tension Range | ±50 mN |
| Tension Resolution | 0.01 mN |
| Pressure Range | 0–250 mmHg |
| Pressure Accuracy | ±0.1 mmHg |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.1 °C |
| Bath Volume | Up to 10 mL (3 mL standard) |
| Bath Material | Acid-Resistant Stainless Steel |
| Heating | Integrated Electronic Feedback Control |
| Analog Output | 1.0 V F.S. (12-bit) |
| Digital Interface | RS232 / RS485 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Environmental Operating Temp | 15–30 °C] |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DMT 111P |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 161FM |
| Pricing | Available Upon Request |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DMT 620M |
| Price | Upon Request |
| Sample Diameter Range | 60 µm to 10 mm |
| Number of Baths | 4 independent stainless-steel baths |
| Bath Capacity | Up to 8 mL per bath |
| Tension Range Options | ±200 / ±400 / ±800 / ±1600 mN |
| Tension Resolution | 0.1 mN |
| Temperature Control Range | Ambient to 45 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating System | Integrated electronic heating with independent bath temperature regulation |
| Bath Exhaust | Manual or programmable automatic aspiration |
| Gas Inlet | Individual needle-valve control per bath |
| Analog Output | 2.5 V full-scale, 4-channel isolated |
| Digital Interface | USB 2.0 |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Operating Ambient | 15–30 °C |
| Calibration | Semi-automatic weight calibration |
| Positioning | Manual micrometer-driven micro-positioner |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 620M |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | FM-120 |
| Measurement Range | 2–50 µm |
| Sampling Area | 0.24 mm² |
| Volumetric Flow Rate | 1 m³/min |
| Sampling Frequency | Adjustable from 0.04 s to 20 s |
| Refractive Index Assumption | 1.33 (non-absorbing, water standard) |
| Scattering Collection Angle | 3.5°–12° (annular forward cone) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 0–100 % RH (non-condensing) |
| Altitude Limit | ≤ 4,000 m |
| Instrument Weight | 10.0 kg |
| External Pump Weight | 9.5 kg |
| Dimensions (Detector Unit) | 23 cm (W) × 37 cm (L) × 28 cm (H) |
| Power Supply | FM-120 unit: 85–264 VAC, 50–60 Hz |
| External pump | 220 VAC |
| Data Interface | RS-422 or RS-232 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 310A / 410A / 510A |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model Number | Not Applicable |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DNA800 |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | DHG-9140A |
| Instrument Type | General-Purpose Forced-Air Drying Oven |
| Temperature Range | RT+10°C to 250°C |
| Temperature Uniformity | ±1°C (at 100°C, empty chamber) |
| Temperature Resolution | 0.1°C |
| Power Input | 2050 W |
| Chamber Dimensions (W×D×H) | 550 × 450 × 550 mm |
| External Dimensions (W×D×H) | 835 × 670 × 730 mm |
| Chamber Volume | 136 L |
| Standard Shelving | 2 adjustable stainless steel trays |
| Timer Range | 1–9999 minutes |
| Compliance | Designed per GB/T 5170.2 (Chinese national standard for temperature testing of dry heat ovens), compatible with ISO/IEC 17025 laboratory environmental control requirements |
| Origin | Shenzhen |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | DIT-KDY-125 |
| Price | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DTY-10A |
| Price | USD 1,350 (FOB China) |
| Temperature Range | −10 to +99 °C |
| Bath Volume | 10 L |
| Cooling Capacity | 700 W at 20 °C ambient |
| Heating Power | 1000 W |
| Temperature Stability | ±0.1 °C |
| Pump Flow Rate | 1–10 L/min (adjustable) |
| Opening Dimensions (L×W×D) | 230 × 115 × 150 mm |
| External Dimensions (L×W×H) | 492 × 392 × 510 mm |
| Construction | Full 304 stainless steel bath and top plate |
| Control System | Digital LED display with touch-sensitive soft keys |
| Temperature Control Algorithm | PID-based output |
| Safety Features | Over-temperature and differential-temperature alarm |
| Refrigeration System | Air-cooled, hermetically sealed compressor |
| Evaporator Design | Optimized large-surface-area evaporator for rapid, uniform cooling |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | YDS-30 |
| Capacity | 30 L |
| Neck Opening Diameter | 50 mm |
| Outer Diameter | 445 mm |
| Height | 660 mm |
| Empty Weight | 13 kg |
| Full Weight (LN₂ + tank) | 37.2 kg |
| Static Hold Time | 220 days |
| Vacuum Insulation | High-vacuum multilayer super-insulation |
| Shell Material | Anodized corrosion-resistant aluminum alloy |
| Protective Cover | Included (genuine leatherette) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Germany |
| Model | DosaPrep X8 |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DPCZ |
| Price Range | USD 4,200 – 7,000 |
| Instrument Type | Manual Operation |
| Haze Range | 0–30% |
| Transmittance Range | 0–100% |
| Haze Repeatability | ±0.2% |
| Transmittance Repeatability | ±0.5% |
| Amylose Detection Range | 0–50% (w/w) |
| Accuracy | ±1% (absolute amylose content) |
| Measurement Time per Sample | ~60 s (excluding sample preparation) |
| Interface | RS-232 serial communication |
| Software Platform | Windows-based control and analysis suite |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DPCZ-I |
| Price Range | USD 1,400 – 7,000 |
| Moisture Accuracy | ±0.5% |
| Amylose Content Accuracy | ±1% |
| Chalkiness Degree Accuracy | ±1% |
| Chalky Grain Ratio Accuracy | ±2% |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | DPCZ-II |
| Pricing | Available Upon Request |
| Detection Principle | Spectrophotometric Absorption (Iodine-Blue Complex Method) |
| Sample Types | Milled rice, wheat, maize (corn), millet |
| Measurement Range | 0–50% (w/w, amylose content) |
| Accuracy | ±1% (relative to reference method per GB/T 15683-2008 or ISO 6647-1) |
| Measurement Time | ~60 seconds per sample (post-extraction) |
| Interface | RS-232 serial communication with Windows-based control software |
| Compliance | Designed for alignment with Chinese national standard GB/T 15683 and international cereal quality testing protocols |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DQP-1100 |
| Power Supply | AC 220 V, 50 Hz |
| Rated Input Power | 1100 W |
| 雾化流量 | 250–300 mL/min |
| Particle Size Distribution | ≤40 µm (mass median aerodynamic diameter) |
| Horizontal Spray Range | 8–10 m |
| Net Weight | ~1.5 kg |
| Tank Capacity | 500 mL or 1200 mL |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DQP-800 |
| Pricing | Available Upon Request |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 800 W |
| 雾化流量 | 0–500 mL/min (adjustable) |
| Particle Diameter Range | 5–100 µm |
| Spray Reach | 7–10 m |
| Net Weight | ~1.5 kg |
| Tank Capacity | 6–8 L |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dr. Drenda APM-2 |
| Pricing | Upon Request |
| Flow Rate | 3.3 L/min |
| Sampling Mode | Continuous |
| Power Supply | 230 V, 50/60 Hz |
| Power Consumption | ~80 VA |
| Measurement Range | 0–1000 µg/m³ |
| Dimensions (W×H×D, excl. inlet & antenna) | 300 × 450 × 250 mm |
| Weight | ~17 kg |
| Ingress Protection | IP65 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dr. Durrand PNS16T |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Alcotest 9510 |
| Pricing | Upon Request |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DRX-II-300A |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Guarded Hot Plate Method |
| Measurement Range | 0.01–2.2 W/m·K |
| Repeatability | ±1.0% |
| Accuracy | ±2.5% |
| Thickness Capacity | Up to 200 mm |
| Cold Plate Temp Range | −40 °C to +60 °C |
| Hot Plate Temp Range | Ambient to 110 °C (optional up to 300 °C or 600 °C) |
| Temperature Control Precision | ±0.1 °C |
| Temp Resolution | 0.01 °C |
| Sample Size | 200 × 200 × (5–20) mm or 300 × 300 × (5–100) mm |
| Power Supply | AC 220 V ±5%, 3.0 kW |
| Compliance | GB/T 10294–2008, ASTM C518, ISO 8302 |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DRH-300 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Guarded Hot Plate Method |
| Dimensions (L×W×H) | 820 × 760 × 950 mm |
| Accuracy | ±2% |
| Thermal Conductivity Range | 0.001–2.20 W/(m·K) |
| Repeatability | ±1% |
| Sample Thickness Range | 5–50 mm |
| Sample Size | 300 × 300 mm |
| Cold Plate Temp. Range | 0–60 °C (0.01 °C resolution) |
| Hot Plate Temp. Range | 10–99.9 °C |
| Temperature Uniformity (Hot/Cold Plates) | ≤0.1 °C |
| Surface Flatness Tolerance | ≤0.5 mm |
| Applied Pressure Range | 0–80 kPa (0.1 kPa resolution) |
| Power Supply | AC 220 V ±5%, 3.0 kW |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DRH300 |
| Quotation | USD 7,650 (FOB) |
| Instrument Type | Guarded Hot Plate Method |
| Dimensions (L×W×H) | 1200 × 700 × 1300 mm |
| Accuracy | ±3% |
| Thermal Conductivity Range | 0.005–3.0 W/(m·K) |
| Repeatability | 1% |
| Temperature Control Range (DRH300A/B/C variants) | 0–40 °C / RT–100 °C / −20–70 °C |
| Sample Size Max | 300 × 300 × 100 mm |
| Thermal Resistance Range | 0.1–8.0 m²·K/W |
| Control System | Peltier-based heated/cooled plates with dual embedded heat flux sensors |
| Compliance | ASTM C518, ISO 8301, GB/T 10294, GB/T 10295, JIS A 1412, DIN EN 12939, DIN EN 13163, DIN EN 12667 |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DRL26C |
| Pricing | Available Upon Request |
| Measurement Principle | Contact-Based Linear Displacement Transduction via High-Resolution Capacitive Sensor |
| Resolution | 1 µm |
| Full-Scale Range | 64 mm |
| Accuracy | ±2% of full scale |
| Actuation Force | 15–20 N |
| Operating Temperature | −30 °C to +60 °C |
| Relative Humidity Range | 0–100% RH (non-condensing) |
| Temperature Sensor Accuracy | ±2 °C |
| Weight | 300 g |
| Data Storage Capacity | 50,000 timestamped records |
| Sampling Interval | Configurable from 10 minutes to 24 hours |
| Battery Life | Up to 5.5 years in standby |
| Power Source | Integrated rechargeable lithium battery |
| Data Output | Wireless infrared (IR) interface compliant with ISO/IEC 15693 |
| Data Export Formats | Plain-text (.txt) and Microsoft Excel (.xlsx) |
| Software Platform | MicroLog Forestry Suite v4.2 (Windows-based, GLP-compliant) |
| Optional Integration | MicroLog Tri-Channel Soil Monitoring Unit (soil moisture, temperature, matric potential) |
| Compliance | Designed per EN 61326-1 (EMC for laboratory equipment), CE-marked, RoHS-compliant |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DRX-06D |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Test Method | Transient Plane Source (TPS) / Comparative Cut-Edge Method per Hydraulic Concrete Standards |
| Heating Power | 4 kW (adjustable) |
| Temperature Measurement Range | 0–100 °C, Accuracy: ±0.1 °C |
| Timing Resolution | 0.1 s |
| Stirring Power | ≤500 W |
| Construction Materials | AISI 304 Stainless Steel (heating bath, cooling bath, sample holder) |
| Automation Level | Fully Computer-Controlled with Real-Time Data Acquisition & Report Generation |
| Compliance | DL/T 5150–2001, SL 3562–2006, DL/T 536–2006 |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DRX-I-JH |
| Pricing | Available Upon Request |
| Max Operating Temperature | RT–600°C / RT–1000°C (configurable) |
| Thermal Conductivity Range | 0.035–40 W/(m·K) and 20–500 W/(m·K) (material-dependent) |
| Sample Geometry | Cylindrical rods (Ø5 × 220 mm for metals |
| Wire Samples | Ø1–3 mm diameter |
| Sample Quantity | ≥2 per test run |
| Measurement Accuracy | ≤5% (typical), down to ±2% under optimized calibration and controlled conditions |
| Vacuum/Atmosphere Control | Customizable (high-vacuum or inert gas purge options) |
| Automation | Fully computer-controlled heating ramping, data acquisition, real-time calculation, and report generation |
| Power Supply | 220 V AC, ≤4 kW total consumption |