Generic
Filter
Showing 1171–1200 of 5200 results
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D873 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E659D |
| Pricing | Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Standard Compliance | ASTM D86, IP 123, ISO 3405 |
| Model | 1000 Series |
| Configuration | Atmospheric Distillation Only |
| Heating Control | Electronically Adjustable Heating Plate |
| Condenser Type | Water-Cooled Chromium-Plated Copper Tube Assembly |
| Construction Material | Stainless Steel (Heater & Condenser Units) |
| Distillation Flask Options | 100 mL (Type A), 125 mL (Type B), 200 mL (Type C), 250 mL (Type D) |
| Receiver Flask Options | 25 mL (Type A), 100 mL (Type B), 200 mL (Type C) |
| Temperature Measurement | ASTM/IP Certified Thermometers (e.g., ASTM 2C, 3C, 105C–107C) |
| Origin | Switzerland |
|---|---|
| Type | ASTM D92 Cleveland Open Cup Flash Point Tester |
| Temperature Range | +79 °C to +400 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Probe | PT100 Platinum Sensor (1/10 DIN Class) |
| Sample Cup | ASTM D92 / IP 36–compliant dimensions and fill level markings |
| Heating System | Electronic heater with overtemperature protection |
| Repeatability & Reproducibility | Meets or exceeds ASTM D92 and IP 36 requirements |
| Dimensions (W×D×H) | 48 × 37 × 61 cm |
| Weight | 32 kg |
| Power Supply | 220 V ±15 %, 50/60 Hz |
| Ambient Operating Limit | ≤35 °C |
| Safety Certification | CE-marked |
| Origin | Switzerland |
|---|---|
| Type | ASTM D86 Compliant Manual Atmospheric Distillation System |
| Model | 1000 Series |
| Configuration | Modular (Heating Unit 990/A + Condensation Unit 990/B) |
| Compliance | ASTM D86, IP 62–88, ISO 3405 |
| Heating Control | Electronically Adjustable Stainless Steel Heating Plate |
| Condenser | Chrome-Plated Copper Tubing with Water-Circulated Jacket |
| Visibility | Front-Mounted Tempered Glass View Window |
| Bottle Capacity Options | 100 mL (Type A), 125 mL (Type B), 200 mL (Type C), 250 mL (Type D) |
| Receiver Volumes | 25 mL (Type A), 100 mL (Type B), 200 mL (Type C) |
| Temperature Measurement | ASTM/IP Calibrated Thermometers (ASTM 2C to 107C / IP 62C to 88C) |
| Origin | New Zealand |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5400RHS |
| Price | Upon Request |
| Temperature Range | −10 °C to +100 °C |
| Temperature Stability | ±0.3 °C |
| Temperature Uniformity | ±0.75 °C |
| Humidity Range | 35–98 %RH |
| Humidity Accuracy | ±2 %RH |
| Effective Volume | 400 L |
| Internal Dimensions (W×D×H) | 640 × 540 × 1225 mm |
| External Dimensions (W×D×H) | 890 × 870 × 2045 mm |
| Shelf Capacity | 6 adjustable stainless-steel shelves |
| Cooling Rate | 70 °C → 0 °C in ≤60 min |
| Heating Rate | −10 °C → 70 °C in ≤45 min |
| Power Consumption | 1750 W |
| Net Weight | 200 kg |
| Gross Weight | 240 kg |
| Compliance | NZS 6200, AS/NZS 3100, IEC 61010-1 |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D1160 |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TSH Series |
| Pricing | Available Upon Request |
| Origin | United Kingdom |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | 5L Benchtop |
| Usable Volume Range | 150 mL – 5 L |
| Operating Pressure | Up to 350 bar |
| Operating Temperature | Up to 350 °C |
| Construction Material | Stainless Steel (316 SS), Hastelloy C-276, Inconel 625, Tantalum, or Titanium |
| Heating System | Electric, PID-Controlled |
| Stirring Options | Magnetic Drive (2000 bar / 650 °C / 3000 rpm) or Mechanical Drive (200 bar / 500 °C / 200 rpm) |
| Sealing Mechanism | Dual-clamp + Automatic Metal C-Ring Seal |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ADE Series |
| Standard Compliance | ASTM E681, EN 45014, GB/T 12474-2008 |
| Operating Pressure Range | 0 to 101 kPa (gauge), adjustable down to –100 kPa (gauge) |
| Maximum Test Temperature | 150 °C |
| Oven Max Temperature | 300 °C |
| Ignition Source | 15 kV, 30 mA pulsed arc, 0.5 s duration |
| Electrode Gap | 3–4 mm |
| Reaction Tube Dimensions | 1400 ± 50 mm length, 60 ± 5 mm ID, ≥2 mm wall thickness (borosilicate glass) |
| Vent Valve Diameter | ≥25 mm |
| Stirring | Magnetic stirrer at tube base |
| Safety Interlock | Dual-door mechanical/electrical interlock with remote activation |
| Flame Detection | Visual + optional thermocouple-assisted detection for non-luminous flames (e.g., H₂) |
| Origin | Germany |
|---|---|
| Type | Automated Distillation Apparatus |
| Model | 3025 |
| Temperature Range | 0–420 °C |
| Volume Resolution | 0.01 mL |
| Distillation Rate Programmable | 2–15 mL/min |
| Compliance | ASTM D86, D850, D1078, D2892 |
| Receiver Chamber Heating | up to 60 °C |
| Safety Systems | Integrated N₂ fire suppression, optical level detection, real-time diagnostics |
| Software | LIMS-integrated, GLP-compliant data logging, ASTM repeatability/reproducibility calculation |
| Network Capacity | Up to 32 units via Ethernet |
| Power Supply | 230 V, 50/60 Hz, 10 A |
| Dimensions (L×W×H) | 53.3 × 54.6 × 70.5 cm |
| Net Weight | 91 kg |
| Origin | United Kingdom |
|---|---|
| Type | Box-type Muffle Furnace |
| Maximum Temperature | 1300 °C |
| Operating Temperature Range | Ambient to 1250 °C (continuous) |
| Internal Dimensions | 150 × 150 × 150 mm (BCF13/5 model) |
| Effective Volume | 5 L |
| Heating Method | Dual-side resistive heating with Kanthal A1 wire embedded in ceramic fiber grooves |
| Insulation | Low-mass ceramic fiber insulation |
| Temperature Uniformity | ±5 °C at 1200 °C (per ASTM E220) |
| Control System | Eurotherm 2416 PID programmable controller with dual-line display |
| Programmable Segments | 8 segments, each configurable for ramp, soak, cooling or end |
| Temperature Sensor | Type R (Platinum–Platinum/Rhodium 13%) thermocouple |
| Power Rating | 2.0 kW (BCF13/5) |
| External Construction | Galvanized steel housing with polyester powder coating |
| Weight | 41 kg (net, BCF13/5) |
| Compliance | CE, UKCA, RoHS, EN 61000-6-3, EN 61000-6-4 |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D2274 |
| Pricing | Available Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Standard Compliance | ASTM D942, DIN 51808, IP 142 |
| Model | D942 |
| Maximum Pressure Rating | 180 psi |
| Sample Capacity | 185 mL |
| Construction Material | Electropolished 18/8 Stainless Steel |
| Temperature Control | Digital PID Controller with PT100 Sensor, Over-Temperature Alarm |
| Bath Insulation | Dual-layer stainless steel housing with integrated heater |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | YL-S90 |
| Quotation | Upon Request |
| Load Capacity Options | 10 N, 20 N, 50 N, 100 N, 200 N, 500 N, 1 kN (dual-range configuration available) |
| Force Resolution | 1/500,000 full scale |
| Force Accuracy | ±0.3% of reading |
| Displacement Resolution | 1/500,000 full scale |
| Test Stroke | 500 mm / 800 mm (selectable) |
| Test Width | 110 mm |
| Speed Range | 0.1–500 mm/min (computer-programmable) |
| Drive System | Stepper motor + precision ground ball screw |
| Power Supply | 220 V, 50/60 Hz, 3 A |
| Power Consumption | 180 W |
| Dimensions (W×D×H) | 40 × 37 × 92 cm or 40 × 37 × 120 cm |
| Net Weight | 28 kg / 35 kg |
| Standard Accessories | One set of quick-release grips, PC software, USB-to-serial interface cable |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | GZL-B |
| Pricing | Upon Request |
| Max Operating Temperature | 1600 °C |
| Heating Element | Silicon Molybdenum (MoSi₂) Rods |
| Temperature Sensor | Type B Platinum–Rhodium Thermocouple |
| Heating Rate | 1–15 °C/min (RT–1300 °C), 1–5 °C/min (1300–1600 °C) |
| Rated Power | ~16 kW |
| Control System | 50-Stage Programmable PID Controller with Auto-Tuning |
| Temperature Uniformity | ±1 °C (Control), ±2 °C (Soak) |
| Atmosphere Options | Air, N₂, Ar |
| Gas Flow Range | 0–10 L/min |
| Sample Dimensions | 40 × 40 × 230 mm (4 specimens per run) |
| Rotation Mechanism | Planetary motion |
| Crucible | Graphite |
| Slag Addition Port | Integrated top-access port |
| Crucible Lift | Bottom-entry vertical hydraulic/pneumatic lift mechanism |
| Origin | Qingdao, Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 3012H |
| Pricing | Available Upon Request |
| Sampling Principle | Isokinetic Sampling via Pitot Tube + Gravimetric Collection |
| Gas Detection Method | Potentiostatic Electrolysis |
| Operating Power | AC 220 V ±10%, 50 Hz or DC 12 V |
| Dimensions | 450 × 168 × 410 mm |
| Weight | ~10.0 kg |
| Noise Level | <65 dB(A) |
| Power Consumption | <180 W |
| Data Storage Capacity | >100,000 measurement records |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 68902 |
| Pricing | Upon Request |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | BP-2010A |
| Pricing | Available Upon Request |
| Display | 4.3-inch color LCD |
| Measurement Principle | Infrared photoplethysmography (PPG) |
| Method | Tail-cuff occlusion with automated inflation/deflation |
| Temperature Control Range | 30–40 °C (adjustable via host or software) |
| Blood Pressure Range | 0–350 mmHg |
| Pulse Rate Range | 0–1000 BPM |
| Measured Parameters | Systolic BP, Mean Arterial Pressure (MAP), Diastolic BP, Heart Rate |
| Data Storage | SD card and/or PC via USB 2.0 |
| Software Features | Automated measurement initiation, post-acquisition editing, averaging (6–7 cycles), scheduled measurements, report generation (PDF/CSV), GLP-compliant audit trail export |
| Throughput | Up to 3 rodents per session (sequential) |
| Measurement Duration | ≤15 min (rats), ≤5 min (mice) |
| Compliance | Designed for ISO 13485-aligned manufacturing environments |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | Multi-Channel Animal Respirometry System |
| Price Range | USD 14,000 – 42,000 |
| Origin | United Kingdom |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model | sCMOS_4MP |
| Pricing | Available Upon Request |
| Active Area (Single Module) | 22.5 × 22.5 mm to 95.5 × 95.5 mm |
| Multi-Module Array Configurations | 134 × 134 mm, 268 × 67 mm, 191 × 191 mm, 382 × 95.5 mm |
| Scintillator Options | Gd₂O₂S:Tb (1–55 keV), CsI:Tl (20–300 keV) |
| Pixel Array | 2048 × 2048 |
| Pixel Size | 11 × 11 µm |
| Full-Well Capacity | 80,000 e⁻ |
| Read Noise | 1.8 e⁻ rms |
| Dark Current | <1 e⁻/pixel/s |
| Quantum Efficiency (Peak) | 58% @ scintillator emission wavelength (no microlens) |
| Exposure Time Range | 50 µs – 60 s |
| Operating Sensor Temperature | −20 °C (water-cooled) |
| Bit Depth | 16-bit |
| Dynamic Range | 20,000:1 |
| Spatial Resolution | Gd₂O₂S:Tb — 25 lp/mm |
| CsI | Tl — 20 lp/mm |
| Frame Rate | 18 fps (full frame), 4.5 fps (full frame, no binning) |
| Interface | Gigabit Ethernet / GenICam-compliant |
| Litron Nano L series Nd | YAG Pulsed Nanosecond Laser System |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Nano L series Nd:YAG |
| Pulse Energy (1064 nm) | 320 mJ |
| Pulse Energy (532 nm) | 180 mJ |
| Pulse Energy (355 nm) | 60 mJ |
| Pulse Energy (266 nm) | 40 mJ |
| Pulse Width (1064 nm) | 10–14 ns |
| Beam Diameter | <6 mm |
| Energy Stability (1064 nm) | ±2.5% RMS |
| Jitter | ≤1.0 ns |
| Repetition Rate | 1–20 Hz |
| Temperature Control Accuracy | ±0.05 °C |
| Cooling Power Capacity | Up to 1200 W |
| Dimensions (Laser Head) | 720 × 136 × 156 mm |
| Dimensions (Power & Cooling Unit) | 435 × 485 × 285 mm |
| Input Power | 220 V AC, 50–60 Hz, 1000 W |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Production | Yes |
| Model | MODEL2030 |
| Price | USD 3,950 (FOB) |
| Measurement Principle | Laser Backscatter Photometry |
| Explosion-Proof Rating | Ex d IIB T4 Gb |
| Measurement Range | 0.01–5000 mg/m³ (standard) |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±1% of reading |
| Relative Error | ±2% FS |
| Operating Temperature | −40 °C to +65 °C |
| Humidity Range | 0–100% RH (non-condensing) |
| Max. Flue Gas Temperature | 300 °C (custom high-temp probe available) |
| Output Signal | 4–20 mA (max. load 500 Ω) |
| Power Supply | DC 16–24 V ±10% |
| Power Consumption | ≤3 W (typical), ≤5 W (max.) |
| Dimensions | 160 × 250 mm (H × D) |
| Weight | 4 kg |
| Flue Diameter Compatibility | 1–15 m |
| Minimum Detectable Concentration | 2 mg/m³ |
| Installation | Single-ended, tool-free mounting |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8869 |
| Pricing | Available Upon Request |
| Measurement Principle | Non-Dispersive Infrared (NDIR) |
| Minimum Range | CO: 0–10 ppm, CO₂: 0–5 ppm |
| Certifications | CE, EN 50081-1, EN 50082-2 |
| Enclosure Rating | IP65 |
| Weight | ~32 kg |
| Power Supply | 220 VAC, 48–63 Hz, 35 W |
| Sample Pressure (Flexible Tubing) | 600–1500 hPa (absolute) |
| (Rigid Tubing) | 500–1500 hPa (absolute) |
| Purge Gas Pressure | <165 hPa (gauge), short-term >250 hPa (gauge) |
| Sample Flow Rate | 0.3–1.5 L/min |
| Sample Temperature | 0–50 °C (standard), 0–80 °C (with optional heater) |
| Sample Humidity | <90% RH |
| Warm-up Time | 2 hours |
| Response Time (T₉₀) | 5 s |
| Damping Time | 0–100 s adjustable |
| Dead Time | 0.5–2.5 s |
| Internal Signal Processing Time | <1 s |
| Output Stability | ±0.1% to ±1% of minimum range |
| Zero Drift | <1% of minimum range per month |
| Span Drift | <1% of full scale per month |
| Repeatability | 0.1–1% of full scale |
| Linearity Error | <0.5% FS |
| Analog Inputs | 2 × 0/2/4–20 mA (cross-interference compensation) |
| Digital Inputs | 6 × 24 V DC, floating |
| Relay Outputs | 6 × 24 V AC/DC, 1 A, floating |
| Communication Interface | RS-485 |
| Operating Ambient Temperature | 5–45 °C |
| Storage/Transport Temperature | −30–+70 °C |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8869 |
| Pricing | Upon Request |
| Measurement Principle | Thermal Conductivity |
| Full Scale Range | 0–100% H₂ |
| Certifications | CE, EN 61326-1:2013/A1:2016, EN 61010-1:2010 |
| Power Supply | 220 VAC, 47–63 Hz, 20 W |
| Enclosure Rating | IP65 per EN 60529 |
| Weight | ~25 kg |
| Sample Gas Connection | 1.4571 stainless steel tubing, Ø6 mm or 1/4″ |
| Leak Rate | <1 µL/s |
| Sample Gas Pressure | 800–1100 hPa (absolute) |
| Sample Flow Rate | 0.5–1.5 L/min |
| Sample Temperature | 0–50 °C |
| Measurement Cell Temperature | ~60 °C |
| Sample Humidity | <90% RH |
| Purge Gas Pressure | 165 hPa (short-term purge: 250 hPa) |
| Warm-up Time | 2 h |
| Response Time (T₉₀) | 5 s |
| Dead Time | ~0.5 s |
| Damping Time | Adjustable 0–100 s |
| Zero Drift | <1% of minimum span/month |
| Repeatability Error | <1% of full scale |
| Linearity Error | ±1% of full scale |
| Output Signal Stability | ±0.75% of minimum span |
| Relay Outputs | 6 × 24 V AC/DC, 1 A, floating, freely configurable |
| Analog Inputs | 2 × 0/2/4–20 mA, cross-interference compensation |
| Binary Inputs | 6 × 24 V, floating, freely configurable |
| Communication Interface | RS-485 |
| Operating Ambient Temperature | 5–45 °C |
| Storage & Transport Temperature | −30 to +70 °C |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 8866 |
| Price | USD 9,400 (FOB) |
| Measurement Principle | Thermal Conductivity Detection (TCD) |
| Range Options | 0–1%, 0–2%, 0–5%, 0–10%, 0–15%, 0–20%, 0–30%, 0–40%, 0–75%, 0–100%, 80–100%, 95–100%, 98–100% He in Ar (also configurable for H₂, CH₄, CO, CO₂, N₂, Ar mixtures) |
| Accuracy | ±1% FS |
| Repeatability | ≤0.3% FS |
| Linearity Error | ≤1% FS |
| Response Time (t₆₀/t₉₀/t₉₉) | H₂ <1 s / 13 s / 24 s / 40 s |
| Zero Drift | ≤1% FS/week |
| Sample Flow Rate | 100 mL/min to 2 L/min |
| Inlet Fitting | 1/4" Swagelok or 6 mm compression |
| Analog Outputs | Four isolated 4–20 mA outputs |
| Digital Communication | RS232 & RS485 (Modbus RTU) |
| Power Supply | 24–30 VDC (sensor), or 115 VAC ±10% / 220 VAC ±20%, 50 ±0.5 Hz, 150 VA |
| Enclosure Rating | IP66 |
| Explosion Protection | ATEX II 2G Ex d IIC T6 Gb, CSA Class I, Division 1, Groups A, B, C, D, T6 |
| Hazardous Area Classification | Zone 1, Zone 2, Class I Div 1 |
| Controller Options | Intrinsically Safe (Ex ia) and Non-Explosive Versions Available |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MK2000-2HL |
| Price | USD 1,150 (FOB) |
| Temperature Range | Ambient +5°C to 100°C |
| Max Temperature | 105°C |
| Heating Time | ≤15 min (25°C → 100°C) |
| Temp Stability @100°C | ±0.4°C |
| Temp Uniformity (Intra-module @37°C) | ±0.2°C |
| Temp Uniformity (Inter-module @37°C) | ±0.3°C |
| Control Method | Dual-channel PID fuzzy control (single-loop for dual modules) |
| Display Resolution | 0.1°C |
| Timer Range | 1 min – 99 h 59 min |
| Programmable Protocols | 60 stored methods, up to 4 temperature/time segments per program |
| Standard Modules | 2 interchangeable blocks |
| Dimensions (W×D×H) | 380 × 210 × 160 mm |
| Net Weight | 5.5 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GA56 Cage |
| Pricing | Upon Request |
| Air Changes per Hour | 10–50 (adjustable) |
| Air Velocity | ≤0.18 m/s |
| Pressure Gradient | 20–50 Pa (adjustable) |
| Air Cleanliness Class | < ISO Class 5 (≤100 particles ≥0.5 µm/m³) |
| Settle Plate Microbial Count | <1 CFU/4 h |
| Noise Level | <55 dB(A) |
| Dimensions (W×D×H) | 1890 × 530 × 1750 mm |
| Rack Configuration | 7 tiers × 8 cages per tier |
| Cage Material | Medical-Grade PSU (Polyphenylsulfone), Autoclavable at 150°C, 15 psi for 30 min |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | PY |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DB-4S |
| Price | Upon Request |
| Temperature Setting Range | +25 °C to +100 °C |
| Temperature Control Range | Ambient +5 °C to +100 °C |
| Stability @37 °C | ±0.03 °C |
| Uniformity @37 °C | ±0.12 °C |
| Setpoint Resolution | 0.1 °C |
| Display | Dual-line LCD |
| Heating Time (25 °C → 37 °C) | 4 min |
| Heating Time (25 °C → 60 °C) | 10 min |
| Heating Time (25 °C → 100 °C) | 40 min |
| Capacity | 32 × 0.2 mL microtubes or 4 × 0.2 mL PCR strip tubes |
| Timer Range | 1–96 h |
| Input Voltage | 12 V DC |
| Input Current | 0.85 A |