| Origin | Israel |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SpotOn CCD Series |
| Component Category | Optical Sensor Module |
| Spectral Range | 190–1550 nm |
| Position Accuracy | ±5 µm |
| Simultaneous Beam Tracking | Up to 3 beams |
| Interface Options | USB 2.0 or PCI |
| Detector Type | Monochrome CCD sensor |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ZKY-II |
| Price | Upon Request |
| Cutting Tool Diameter | 28 mm |
| Dimensional Accuracy | ±0.2 mm |
| Worktable Dimensions | 450 × 320 mm |
| Specimen Thickness Range | 1–15 mm |
| Power Supply | 220 V AC |
| Overall Dimensions (L×W×H) | 450 × 320 × 550 mm |
| Weight | 60 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RAD7 |
| Sampling Method | Active Sampling |
| Detection Range | 3.7–74,000 Bq/m³ (0.1–20,000 pCi/L) |
| Minimum Detectable Concentration | 3.7 Bq/m³ (0.1 pCi/L) |
| Sensitivity | 12.8 counts/min per Bq/m³ (air monitoring mode) |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Dust Generator |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BY-PM10 |
| Pricing | Available Upon Request |
| Length Options | 2-Section (1.2 m), 3-Section (1.8 m) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dustmate |
| Measurement Principle | Laser Light Scattering |
| Measurable Parameters | TSP, PM1.0, PM2.5, PM10 |
| Measurement Range | 0–6000 µg/m³ |
| Cut-Point Diameter (Da₅₀) | (10 ± 0.5) µm |
| Geometric Standard Deviation (σg) | 1.5 ± 0.15 |
| Detectable Particle Size Range | 0.5–15 µm |
| Channel Configuration | 3-channel size-resolved counting |
| Sampling Flow Rate | 500 mL/min |
| Resolution | 1 µg/m³ |
| Repeatability | RSD < 5% |
| Overall Uncertainty | ≤ 25% (vs. gravimetric reference method) |
| Operating Environment | −5 to +40 °C, 0–100% RH (non-condensing) |
| Dimensions | 160 × 100 × 90 mm |
| Weight | 0.6 kg (instrument only) |
| Power Supply | Rechargeable 6 V DC / 1.2 Ah battery |
| AC adapter | 220 V, 50–60 Hz |
| Interface | RS-232 serial port |
| Calibration Standard | Whatman GF/A 25 mm circular filter |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DUSTMATE |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DUSTMATE |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DV3000 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TDV-04 |
| Pricing | Upon Request |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DVIO-I |
| Pricing | Available Upon Request |
| Natural Frequency | Vertical 1.2–1.5 Hz, Horizontal 1.5–1.7 Hz |
| Operating Pressure | 3–7 kgf/cm² (43–100 psi) |
| Pneumatic System | Dual-chamber air chamber with four or six high-stability elastomeric air springs |
| Leveling Mechanism | Three vacuum-actuated horizontal adjustment valves with sub-second response time |
| Table Structure | Triple-layer honeycomb core sandwich construction |
| Top Surface | 4.0 mm thick ASTM A240 430-series ferromagnetic stainless steel (low thermal expansion, μm/°C coefficient < 10.5) |
| Core | Steel hexagonal honeycomb with 0.25 mm wall thickness, 3.2 cm² cell area |
| Base Plate | 4.0 mm carbon steel with black oxide finish |
| Perimeter Walls | 2.0 mm carbon steel clad with high-damping polyethylene |
| Flatness | ±0.1 mm over 600 mm × 600 mm |
| Mounting Pattern | M6 threaded holes on 25 mm × 25 mm grid (edge offset: 37.5 mm), each with cylindrical isolation cup seal |
| Thickness Options | 50 / 100 / 200 / 300 mm |
| Optional Configurations | Imperial hole pattern (¼"-20), custom dimensions up to 3600 mm × 1500 mm |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DVV2000 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DW-40L262 |
| Pricing | Available Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | DYM3 |
| Pricing | Upon Request |
| Pressure Range | 800–1064 hPa |
| Operating Temperature | −10 to +40 °C |
| Temperature Scale Range | −11 to +41 °C |
| Max. Pressure Error (after correction) | ≤2.0 hPa |
| Pressure Scale Division | 1 hPa |
| Temperature Scale Division | 1 °C |
| Weight | ≤1.5 kg |
| Dimensions | 156 mm × 156 mm × 115 mm |
| Standard Package | 1 unit barometer, 1 instruction manual, 1 certificate of conformity, 1 protective carrying case |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | DYM3 |
| Pricing | Upon Request |
| Measurement Range | 800–1064 hPa |
| Operating Temperature | −10 to +40 °C |
| Accuracy | ±2.5 hPa |
| Scale Division | 1 hPa |
| Thermometer Division | 1 °C |
| Weight | ≤1.5 kg |
| Dimensions | 156 × 156 × 115 mm |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DTM-II |
| Price | USD 7,000 (FOB) |
| Frequency Range | 100–20 kHz |
| Frequency Resolution | 1 Hz |
| Frequency Accuracy | ±0.5% |
| Dynamic Elastic Modulus Range | Corresponding to measured resonance frequency |
| Modulus Resolution | 0.05 GPa |
| Modulus Accuracy | ±0.1 GPa |
| System Relative Error | ±0.15% |
| Damping/Internal Friction (Q⁻¹) | 1×10⁻⁵ to 0.1 |
| Test Temperature | Ambient to 1750 °C |
| Shear Modulus Measurement | Yes |
| Poisson’s Ratio Calculation | Yes |
| Data Interface | RS-232/USB (optional) |
| Display Modes | Resonance Frequency, Dynamic Elastic Modulus, Spectral Plot, Damping Index |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DRS2170 |
| Pricing | Upon Request |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | DDV-II |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 480/490 |
| Price | Upon Request |
| Power Range | 4.44 kW to 56,800 kW |
| Torque Range | 2.8 N·m to 452,000 N·m |
| Speed Accuracy (end-point) | ±0.01% FS |
| Combined Accuracy (Power/Torque) | ±0.08% FS |
| Temperature Compensation Range | +75 °F to +175 °F |
| Analog Output Options | ±5 V or ±10 V dc (user-selectable) |
| Digital Interface | RS232 with full unit-aware data streaming |
| Frequency Response | 0–2 kHz |
| System Resolution | 0.02% FS (14-bit equivalent with 50% overrange) |
| EMI Hardening | IGBT-drive compatible |
| Filter Options | 11 Bessel-type cutoff settings (0.1–200 Hz, 1–2–5 decade steps) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-10 |
| Output Capacity | 10 L/h |
| Heating Power | 7.5 kW |
| Input Voltage | 380 V AC |
| Construction Material | AISI 304 Stainless Steel |
| Compliance | Meets GB/T 6682–2008 Grade III Water Specifications |
| Safety Features | Auto shut-off on low water level, audible alarm, auto-refill & restart logic |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | DZ-360A Ultra-Large Capacity Orbital Shaker |
| Pricing | USD 6,750 (FOB China) |
| Instrument Category | General-Purpose Orbital Shaker |
| Timing Range | Not equipped with digital timer |
| Oscillation Frequency | Not specified in technical documentation |
| Oscillation Amplitude | 30 mm |
| Temperature Control | Ambient-only operation (no integrated heating/cooling) |
| Platform Count | 3 independent orbital platforms |
| Total Capacity | 300 × 500 mL flasks or 96 × 500 mL Erlenmeyer flasks |
| External Dimensions | 1600 × 1400 × 1400 mm (W × D × H) |
| Power Consumption | 1000 W |
| Drive Mechanism | Balanced eccentric drive with reinforced steel frame |
| Operating Mode | Continuous orbital motion (20–25 rpm typical range for ultra-large loads, per industry-standard load calibration) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Models | DZ-5 / DZ-10 / DZ-20 |
| Power Input | 5 kW (220 V), 7.5 kW (380 V), 15 kW (380 V) |
| Output Capacity | 5 L/h, 10 L/h, 20 L/h |
| Construction Material | AISI 304 Stainless Steel |
| Compliance | GB/T 6682–2008 Grade III Water Specification |
| Safety Features | Automatic dry-run cutoff, audible/visual low-water alarm, auto-refill & restart logic |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DZ-9001 |
| Price | USD 1,230 (FOB Jiangsu) |
| Speed Range | 50–250 rpm |
| Operating Temperature | Ambient (15–30 °C) |
| Platform Capacity | 60 × 250 mL Erlenmeyer flasks |
| Display | LED digital interface |
| Drive Mechanism | Brushless DC motor with eccentric drive |
| Orbit Diameter | 25 mm |
| Dimensions (W×D×H) | 720 × 720 × 850 mm |
| Net Weight | 85 kg |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | DZ-900A |
| Price | USD 2,480 (FOB Jiangsu) |
| Instrument Category | General-Purpose Orbital Shaker |
| Timer Range | Not equipped with mechanical/electronic timer (external timer or lab workflow control required) |
| Oscillation Frequency | 40–250 rpm |
| Orbital Diameter | 25 mm (standard for orbital shakers unless specified otherwise) |
| Temperature Control | Ambient-only operation (non-thermostatic) |
| Shelf Configuration | Two independently accessible stainless-steel shaking platforms |
| Capacity | 120 × 250 mL flasks or 96 × 500 mL flasks per layer |
| Dimensions (W×D×H) | 950 × 650 × 730 mm |
| Power Consumption | 100 W |
| Drive Mechanism | Brushless DC motor with microprocessor-controlled feedback loop |
| Operating Mode | Horizontal orbital motion (eccentric drive) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DZ2000 |
| Price | USD 2,650 (FOB) |
| Optical System | UCIS Infinity-Corrected, Parfocal, Positive-Image Path |
| Magnification Range | 40×–400× (expandable to 960× with optional 60× objective) |
| Eyepieces | Widefield PL10×/20 mm (high-eye-point, reticle-compatible) |
| Objectives | Infinity Long Working Distance (LWD) Plan Achromatic: 4×, 10×, 20×, 40× |
| Phase Contrast | 10×, 20×, 40× LWD |
| Condenser | N.A. 0.70, WD 72 mm / 120 mm, removable, with aperture diaphragm |
| Focusing | Coaxial coarse/fine focus |
| Stage | Mechanical XY stage, 80 × 50 mm travel |
| Illumination | 6 V / 30 W halogen lamp with aspheric collector lens |
| Fluorescence Module | Rotating filter turret for dual-band (B/G) or quad-band (UV/V/B/G) excitation |
| Camera Port | Trinocular port with 80:20 beam splitter ratio |
| Compliance | Designed per ISO 10934-1 (Microscopes — Nomenclature of components), IEC 61010-1 (Safety requirements for electrical equipment), and GLP-aligned documentation architecture |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DZF-1B |
| Price | USD 540 (FOB Shanghai) |
| Voltage/Power | 220 V / 300 W |
| Chamber Dimensions (W×D×H) | 300 × 300 × 275 mm |
| Temperature Range | 50–250 °C |
| Construction | 304 Stainless Steel Interior |
| Door | Tempered Safety Glass with Adjustable Latching Mechanism |
| Sealing | Monolithic Silicone Rubber Gasket |
| Vacuum Compatibility | Compatible with Standard Two-Stage Rotary Vane Pumps (e.g., ≤ 10 Pa Base Pressure) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DZKW |
| Price | USD 110 (FOB Shanghai) |
| Power Rating | 1000 W (4-hole), 1500 W (6-hole), 2000 W (8-hole) |
| Chamber Dimensions (W×D×H) | 325×330×90 mm (4-hole), 480×330×90 mm (6-hole), 650×330×90 mm (8-hole) |
| Temperature Range | Ambient +5°C to 100°C |
| Control Accuracy | ±0.5°C |
| Construction | 304 Stainless Steel Inner Tank & Lid, Electrostatically Powder-Coated Exterior |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | DZKW-S-8 |
| Price | USD 135 |
| Power Rating | 2000 W |
| Chamber Dimensions (W×D×H) | 650 × 330 × 90 mm |
| Well Configuration | Dual-row, 8 wells |
| Construction | Stainless steel inner tank and lid |
| Surface Finish | Electrostatic powder coating |
| Temperature Control | Digital PID controller |
| Typical Temp Range | Ambient +5°C to 100°C |
| Accuracy | ±0.5°C at 37°C (typical) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EAB1-2000 / EAB1-95 |
| Price | USD 1,020 (FOB Shanghai) |
| Instrument Category | Aflatoxin B1 Quantification System |
| Detection Principle | Solid-Phase Enzyme-Linked Immunosorbent Assay (ELISA) |
| Wavelength | 450 ± 2 nm (standard interference filter) |
| Absorbance Range | –0.041 to 1.999 A |
| Detection Limit | 0.1 ng/mL |
| Quantitative Range | 0.1–1.0 ng/mL (ppb) |
| Sensitivity | < 0.1 ng/mL |
| Accuracy | ±0.1 ng/mL |
| Throughput | 20 samples/hour |
| Light Source | LED (3.6 V / 20 mA) |
| Operating Environment | 5–35 °C, ≤85% RH |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Dimensions (EAB1-95) | 350 × 270 × 210 mm |
| Weight (EAB1-95) | 9 kg |
| Dimensions (EAB1-2000) | 410 × 264 × 110 mm |
| Weight (EAB1-2000) | 10 kg |
| Power Consumption | 37 W (EAB1-95), 40 W (EAB1-2000) |
| Transmittance Stability (EAB1-2000) | ≤0.3% T/5 min (bright), ≤0.2% T/5 min (dark) |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Easi Flash |
| Instrument Type | Medium-Pressure Preparative Liquid Chromatography System |
| Max. Operating Pressure | 5.5 bar |
| Max. Flow Rate | 250 mL/min |
| Pump Technology | Centrifugal (EasiPump) |
| Column Diameter Compatibility | 12 mm, 26 mm, 40 mm |
| Solvent-Wetted Materials | PTFE (Teflon®) |
| Construction | Anodized Aluminum Housing |
| Portability | Hand-Carried Design |