KANOMAX
Filter
Showing 211–240 of 500 results
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6720-DP Grid |
| Instrument Type | Pitot Tube-Based Anemometer with Grid Probe Array |
| Resolution | 0.01 m/s (velocity), 0.001 Pa (differential pressure), 1 m³/h (airflow) |
| Measurement Range | 0.15–40 m/s (pitot tube), 0.15–15 m/s (grid probe), −2500 to +2500 Pa (ΔP), 40–4300 m³/h (airflow) |
| Accuracy | ±3% ±0.05 m/s (velocity >0.25 m/s), ±3% ±8 m³/h (airflow >85 m³/h), ±1.5% ±0.25 Pa (ΔP) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Operating Humidity | 0–100 %RH |
| Battery Life | ~14 h (4 × AA alkaline) |
| Display | 4.3-inch full-color capacitive touchscreen |
| Data Storage | 8,000 records (device), 10,000 records (mobile app) |
| Connectivity | Bluetooth 5.0, USB-C, optional thermal printer support |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6720-DP Grid |
| Instrument Type | Pitot Tube Anemometer with Grid Sensor Array |
| Resolution | 0.01 m/s (velocity), 0.001 Pa (differential pressure), 1 m³/h (flow) |
| Measurement Range | 0.15–40 m/s (Pitot), 0.15–15 m/s (Grid Sensor), −2500 to +2500 Pa (ΔP), 40–4300 m³/h (volumetric flow) |
| Accuracy | ±3% ±0.05 m/s (velocity, >0.25 m/s), ±3% ±8 m³/h (flow, >85 m³/h), ±1.5% ±0.25 Pa (ΔP) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Operating Humidity | 0–100 %RH |
| Display | 4.3-inch full-color touchscreen |
| Data Storage | 8,000 records (device), 10,000 records (mobile app) |
| Battery Life | ~14 h (4 × AA alkaline) |
| Weight | ~3.6 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6720-DP Grid |
| Instrument Type | Pitot Tube Anemometer with Grid Sensor Array |
| Resolution | 0.01 m/s (velocity), 0.001 Pa (differential pressure), 1 m³/h (airflow) |
| Measurement Range | 0.15–40 m/s (pitot tube), 0.15–15 m/s (grid sensor), −2500 to +2500 Pa (ΔP), 40–4300 m³/h (airflow) |
| Accuracy | ±3% ±0.05 m/s (>0.25 m/s), ±3% ±8 m³/h (>85 m³/h), ±1.5% ±0.25 Pa |
| Operating Temperature | 0–60 °C (non-condensing) |
| Operating Humidity | 0–100 %RH |
| Display | 4.3-inch full-color touchscreen |
| Data Storage | 8,000 records (device), 10,000 records (mobile app) |
| Battery Life | ~14 h (4 × AA alkaline) |
| Weight | ~3.6 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6720-DP Grid |
| Instrument Type | Pitot Tube-Based Anemometer with Grid Array Sensor |
| Resolution | 0.01 m/s (velocity), 0.001 Pa (differential pressure), 1 m³/h (airflow) |
| Measurement Range | 0.15–40 m/s (pitot tube), 0.15–15 m/s (grid array), −2500 to +2500 Pa (ΔP), 40–4300 m³/h (airflow) |
| Accuracy | ±3% ±0.05 m/s (>0.25 m/s, velocity), ±3% ±8 m³/h (>85 m³/h, airflow), ±1.5% ±0.25 Pa (ΔP) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Operating Humidity | 0–100 %RH |
| Battery Life | ~14 h (4 × AA alkaline) |
| Data Storage | 8,000 records (device), 10,000 records (mobile app) |
| Display | 4.3-inch full-color capacitive touchscreen |
| Connectivity | Bluetooth 4.2, USB data export |
| Compliance | Designed for ISO 14644-3, ISO 14644-4, and EU GMP Annex 1 cleanroom qualification protocols |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6720-DP Grid |
| Instrument Type | Pitot-static Tube Anemometer with Grid Sensor Array |
| Resolution | 0.01 m/s (velocity), 1 m³/h (flow), 0.001 Pa (differential pressure) |
| Measurement Range | 0.15–40 m/s (pitot), 0.15–15 m/s (grid array), 40–4300 m³/h (air flow), −2500 to +2500 Pa (differential pressure) |
| Accuracy | ±3% ±0.05 m/s (velocity, >0.25 m/s), ±3% ±8 m³/h (flow, >85 m³/h), ±1.5% ±0.25 Pa (differential pressure) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Operating Humidity | 0–100 %RH |
| Display | 4.3-inch full-color capacitive touchscreen |
| Data Storage | 8,000 records (device), 10,000 records (mobile app) |
| Battery Life | ~14 hours (4 × AA alkaline) |
| Weight | ~3.6 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6720-DP Grid |
| Instrument Type | Pitot Tube Anemometer with Grid Sensor Array |
| Resolution | 0.01 m/s (velocity), 1 m³/h (flow), 0.001 Pa (differential pressure) |
| Measurement Range | 0.15–40 m/s (pitot tube), 0.15–15 m/s (grid sensor), 40–4300 m³/h (air flow), −2500 to +2500 Pa (differential pressure) |
| Accuracy | ±3% ±0.05 m/s (velocity, >0.25 m/s), ±3% ±8 m³/h (flow, >85 m³/h), ±1.5% ±0.25 Pa (differential pressure) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Operating Humidity | 0–100 %RH |
| Display | 4.3-inch full-color capacitive touchscreen |
| Data Storage | 8,000 records (internal), 10,000 records (mobile app) |
| Battery Life | ~14 hours (4 × AA alkaline batteries) |
| Weight | ~3.6 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6720-DP Grid |
| Instrument Type | Pitot Tube Anemometer with Grid Sensor Array |
| Resolution | 0.01 m/s (velocity), 1 m³/h (flow), 0.001 Pa (differential pressure) |
| Measurement Range | 0.15–40 m/s (pitot tube), 0.15–15 m/s (grid sensor), 40–4300 m³/h (volumetric flow), −2500 to +2500 Pa (differential pressure) |
| Accuracy | ±3% ±0.05 m/s (velocity >0.25 m/s), ±3% ±8 m³/h (flow >85 m³/h), ±1.5% ±0.25 Pa (differential pressure) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Operating Humidity | 0–100 %RH |
| Display | 4.3-inch full-color touchscreen |
| Data Storage | 8,000 records (internal), 10,000 records (mobile app) |
| Battery Life | ~14 hours (4 × AA alkaline) |
| Weight | ~3.6 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6720-DP Grid |
| Instrument Type | Pitot Tube Anemometer |
| Resolution | 0.01 m/s (air velocity), 1 m³/h (airflow), 0.001 Pa (differential pressure) |
| Measurement Range | 0.15–40 m/s (pitot tube), 0.15–15 m/s (grid sensor), −2500–2500 Pa (dP), 40–4300 m³/h (airflow) |
| Accuracy | ±3% ±0.05 m/s (>0.25 m/s, air velocity), ±3% ±8 m³/h (>85 m³/h, airflow), ±1.5% ±0.25 Pa (differential pressure) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Operating Humidity | 0–100 %RH |
| Display | 4.3-inch full-color capacitive touchscreen |
| Data Storage | 8,000 records (device), 10,000 records (mobile app) |
| Battery Life | ~14 hours (4 × AA alkaline batteries) |
| Weight | ~3.6 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6720-DP Grid |
| Instrument Type | Pitot Tube Anemometer |
| Velocity Range | 0.15–40 m/s (Pitot Tube), 0.15–15 m/s (Grid Probe) |
| Differential Pressure Range | −2500 to +2500 Pa |
| Velocity Resolution | 0.01 m/s |
| DP Resolution | 0.001 Pa |
| Velocity Accuracy | ±3% of reading ±0.05 m/s (>0.25 m/s) |
| DP Accuracy | ±1.5% of reading ±0.25 Pa |
| Airflow Range | 40–4300 m³/h |
| Airflow Accuracy | ±3% of reading ±8 m³/h (>85 m³/h) |
| Airflow Resolution | 1 m³/h |
| Operating Temperature | 0–60 °C (non-condensing) |
| Operating Humidity | 0–100 %RH |
| Display | 4.3-inch full-color touchscreen |
| Data Storage | 8,000 records (instrument), 10,000 records (mobile app) |
| Battery Life | ~14 h (4 × AA alkaline) |
| Weight | ~3.6 kg |
| Connectivity | Bluetooth 4.2, USB 2.0 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6750 |
| Resolution | 1 m³/h |
| Measurement Range | ±8–600 m³/h |
| Accuracy | ±(3% of reading + 1 m³/h) for 8–350 m³/h |
| Operating Temperature | 0–50 °C |
| Operating Humidity | 0–100 %RH |
| Display | Full-color TFT LCD with transparent viewing window |
| Connectivity | Bluetooth 4.2 (BLE) for wireless data transmission |
| Power Supply | Rechargeable Li-ion battery (up to 8 h continuous operation) |
| Compliance | CE, RoHS, JIS B 8623 (Air Flow Measuring Instruments) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6750+ |
| Resolution | 1 m³/h |
| Measurement Range | ±8–600 m³/h |
| Accuracy | ±(3% of reading + 1 m³/h) for 8–350 m³/h |
| Operating Temperature | 0–50 °C |
| Operating Humidity | 0–100 %RH |
| Display | 160×80 mm color LCD |
| Data Storage | Up to 6,000 records (internal) |
| Communication | Bluetooth v4.0, USB output |
| Power | 4 × AA batteries or AC adapter |
| Battery Life | Approx. 8 hours |
| Dimensions (hood) | 355(W)×355(H)×450(D) mm |
| Hood Aperture | 355×355 mm |
| Weight | 1.5 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6750 |
| Resolution | 1 m³/h |
| Flow Range | ±8–600 m³/h |
| Accuracy | ±(3% of reading + 1 m³/h) for 8–350 m³/h |
| Operating Temperature | 0–50 °C |
| Operating Humidity | 0–100 %RH |
| Temperature Measurement Range | 0–50 °C |
| Temperature Accuracy | ±0.5 °C |
| Display | Dual-parameter (airflow + temperature), battery level, unit toggle (m³/h / CFM, °C), on-device data processing |
| Communication | Bluetooth 4.0, USB output |
| Data Storage | Up to 6,000 records (internal memory) |
| Power | 4 × AA alkaline batteries or AC adapter |
| Battery Life | Approx. 8 hours continuous operation |
| Dimensions (Hood) | 355 × 355 × 450 mm (W×H×D) |
| Hood Aperture | 355 × 355 mm |
| Display Module | 160 × 80 × 45 mm |
| Weight | 1.5 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6750 |
| Instrument Type | Pitot-Static Air Flow Hood |
| Flow Range | ±8–600 m³/h |
| Accuracy | ±(3% of reading + 1 m³/h) for 8–350 m³/h |
| Temperature Range | 0–50 °C |
| Temp. Accuracy | ±0.5 °C |
| Display | 160×80 mm full-color LCD |
| Data Storage | 6,000 records (internal) |
| Connectivity | Bluetooth 4.0, USB output |
| Power | 4 × AA batteries or AC adapter |
| Operating Time | ~8 hours |
| Dimensions (hood) | 355 × 355 × 450 mm (W×H×D) |
| Weight | 1.5 kg |
| Probe Material | Fiberglass support rod |
| Compliance | Designed for HVAC commissioning per ASHRAE 111, ISO 16813, and EN 12599 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 6822 / 6824 |
| Instrument Type | Vane Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.2–20.0 m/s |
| Accuracy | ±3% of reading or ±0.1 m/s (whichever is greater) |
| Operating Temperature | −20 to +100 °C |
| Operating Humidity | 5.0–95.0 %RH |
| Temperature Accuracy | ±1.0 °C |
| Probe Diameter | 70 mm |
| Power Supply | 3 × AA batteries |
| Battery Life | Approx. 150 hours |
| Dimensions (W×H×D) | 81 × 165 × 38 mm |
| Weight | 175 g (including batteries) |
| Air Volume Range | 0–9,999 CFM |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Model | 6850+ |
| Pressure Range | −2500 to +2500 Pa |
| Accuracy | ±0.5% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Velocity Range | 0.20–60.0 m/s |
| Velocity Accuracy | ±1.5% of reading (at 10.0 m/s) |
| Velocity Resolution | 0.01 m/s |
| Flow Rate Range | 0–999999 m³/h |
| Flow Resolution | 1 m³/h |
| Operating Temperature | 0–60 °C (non-condensing) |
| Storage Temperature | −20–70 °C (non-condensing) |
| Power Supply | 4 × AA batteries or DC 5 V adapter |
| Battery Life | >15 hours |
| Weight (with batteries) | ~360 g |
| Display | Full-color LCD |
| Data Storage | 10,000 records with USB export capability |
| Measurement Media | Air and non-corrosive gases |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Model | 6850+ |
| Pressure Range | −2500 to +2500 Pa |
| Accuracy | ±0.5% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Velocity Range | 0.20–60.0 m/s |
| Velocity Accuracy | ±1.5% of reading (at 10.0 m/s) |
| Velocity Resolution | 0.01 m/s |
| Flow Rate Range | 0–999999 m³/h |
| Flow Resolution | 1 m³/h |
| Operating Temperature | 0–60 °C (non-condensing) |
| Storage Temperature | −20–70 °C (non-condensing) |
| Power | 4 × AA batteries or DC 5 V adapter |
| Battery Life | >15 h |
| Weight (with batteries) | ≈360 g |
| Data Storage Capacity | 10,000 records |
| Interface | USB for direct data export to USB flash drive |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | CTA/HWA 7000 |
| Sensor Type | Thermal (Constant-Temperature Anemometry) |
| Bridge Ratio Options | 1:1 (max. 500 mA) or 5:1 (max. 1.2 A) |
| Probe Current Limit | 500 mA (1:1 configuration) |
| Frequency Response | Up to 140 kHz (with 5 µm tungsten wire probe) |
| Power Supply | AC 100/115 V ±10%, 50/60 Hz |
| Enclosure Dimensions | 436 × 149 × 456 mm |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments and ASTM D5467-compliant airflow characterization |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 1910.134, CSA Z94.4, ISO 16900-1 |
| Test Method | Controlled Negative Pressure (CNP) / Ambient Aerosol Condensation Nucleus Counting (CNC) |
| Supported Respirator Types | Disposable particulate respirators (N95, KN95, KP95, N99, KN100), half-mask and full-face elastomeric respirators, PAPRs, surgical masks (for qualitative/quantitative fit assessment) |
| Language Interface | English, French, German, Spanish, Japanese |
| Connectivity | USB 2.0, Ethernet (10/100BASE-T), Wi-Fi 802.11 b/g/n |
| Multi-unit Control | Up to 4 units via single PC |
| Data Management | Audit-trail enabled, GLP-compliant export (CSV, PDF), optional 21 CFR Part 11 software module |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | Kanomax 3000-0C |
| Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch true-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Supported Languages | English, French, Spanish, Portuguese, Chinese |
| Max Simultaneous Units Controlled via PC | 4 |
| Data Export Format | Microsoft Excel |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | Kanomax 3000-0C |
| Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch true-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Language Options | English, French, Spanish, Portuguese, Chinese |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | AccuFIT 9000 |
| Particle Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch full-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Language Support | English, French, Spanish, Portuguese, Chinese |
| Multi-unit Control | Up to 4 units controlled simultaneously via single PC |
| Data Export Format | Microsoft Excel (.xlsx) |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 29 CFR 1910.134, CSA Z94.4–18 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KANOMAX 3000-0C |
| Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch true-color touchscreen |
| Communication Interfaces | USB (Host×2, Device×1), Ethernet×1, Wi-Fi enabled |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Language Support | English, French, Spanish, Portuguese, Chinese |
| Max Simultaneous Units Controlled via PC | 4 |
| Data Export Format | Microsoft Excel |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | AccuFIT 9000 |
| Particle Detection Method | Condensation Particle Counter (CPC) |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation | Direct Cout/Cin Ratio |
| Challenge Agent | ≥99.5% Isopropanol or Ethanol |
| Display | 7-inch Full-Color Touchscreen (Chinese, English, Japanese, French, Spanish, Portuguese) |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, UK HSE INDG479, GB 19083–2010, GB 2626–2019, GB/T 32610–2016 |
| Data Interface | USB, Ethernet, Wi-Fi |
| Software Control | Single PC manages up to 4 units simultaneously |
| Operating Environment | 10–35°C, 20–85% RH (non-condensing) |
| Dimensions | 208 × 117 × 262 mm (W×H×D) |
| Weight | 2.3 kg |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C, 3000-C1 |
| Particle Size Range | 0.02–1.0 µm (3000-0C), 0.015–1.0 µm (3000-C1) |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Concentration Range | 0–100,000 particles/cm³ |
| Fit Factor Calculation | Direct Cout/Cin ratio |
| Test Agent | ≥99.5% isopropanol or ethanol |
| Display | 7-inch full-color touchscreen |
| Operating Temperature | 10–35 °C |
| Relative Humidity | 20–85% RH (non-condensing) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions (W×H×D) | 208×117×262 mm (3000-0C), 208×152×263 mm (3000-C1) |
| Weight | 2.3 kg (3000-0C), 3.1 kg (3000-C1) |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, HSE INDG 479, GB 19083–2010, GB 2626–2019, GB/T 32610–2016 |
| Software | Windows 7/8/10, .NET Framework 3.5, Excel-compatible reporting |
| Communication | USB, Ethernet, Wi-Fi |
| Multi-unit Control | Up to 4 units per PC |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-C1 |
| Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Challenge Agent | Isopropyl Alcohol (≥99.5% purity) or Ethanol |
| Display | 7-inch true-color touchscreen |
| Operating Temperature | 10–35 °C |
| Relative Humidity | 20–85% RH (non-condensing) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm (W × H × D) |
| Weight | 2.3 kg |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, UK HSE Guidance, GB 2626–2019, GB 19083–2010 |
| Communication Interfaces | USB, Ethernet, Wi-Fi |
| Software Compatibility | Windows 7/8/10, .NET Framework 3.5 |
| Data Export Format | Microsoft Excel (.xlsx) |
| Multi-unit Control | Up to 4 units per PC |
| Language Options | English, Japanese, Chinese, French, Spanish, Portuguese |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | AccuFIT 9000 |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 1910.134, CSA Z94.4, ISO 16900-1/3 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | AccuFIT 9000 |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 29 CFR 1910.134, CSA Z94.4, NIOSH-approved fit test protocols |
| Test Method | Controlled Negative Pressure (CNP) / Ambient Aerosol Condensation Nucleus Counting (CNC) |
| Supported Respirator Types | Disposable particulate respirators (N95, KN95, KP95, N99, KN100), half-face and full-face elastomeric respirators, PAPRs (with appropriate adapters) |
| Language Interface | English, French, German, Spanish, Japanese |
| Connectivity | USB 2.0, Ethernet (10/100 Mbps), Wi-Fi 802.11 b/g/n |
| Multi-unit Control | Up to 4 units via single PC |
| Data Output | CSV, PDF reports with audit trail |
| Software | AccuFIT Manager v4.x (Windows 10/11, 64-bit) |
| Regulatory Support | FDA 21 CFR Part 11 compliant configuration available (electronic signatures, audit trail, user access control) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | AccuFIT 9000 |
| Particle Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch full-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Supported Languages | English, French, Spanish, Portuguese, Chinese |
| Multi-unit Control | Up to 4 units simultaneously via single PC |
| Data Export Format | Microsoft Excel |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 1910.134, CSA Z94.4, ANSI/ASSP Z88.10 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | AccuFIT 9000 |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 29 CFR 1910.134, CSA Z94.4, NIOSH-approved fit test protocols |
| Test Method | Controlled Negative Pressure (CNP) / Ambient Aerosol Condensation Nucleus Counting (CNC) |
| Supported Respirator Types | Disposable particulate respirators (N95, KN95, KP95, N100, KN100), half-face and full-face elastomeric respirators, powered air-purifying respirators (PAPRs) |
| TIL (Total Inward Leakage) Evaluation Basis | Per-test subject (10-subject panel), per-operation (5 operations × 10 subjects), pass thresholds per standard (e.g., KN95/KP95: TIL < 8% for ≥8 of 10 subjects) |
| Interface Options | USB 2.0, Ethernet, Wi-Fi (IEEE 802.11 b/g/n), multi-language UI (English, Chinese, Japanese, Korean, Spanish) |
| Software Control | Standalone operation or PC-synchronized control (up to 4 units per host) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C |
| Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch true-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Language Support | English, French, Spanish, Portuguese, Chinese |
| Multi-unit Control | Up to 4 units simultaneously via single PC |
| Data Export Format | Microsoft Excel |