| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6332D |
| Instrument Type | Hot-Wire Anemometer |
| Measurement Range | 0.1–50 m/s (9–8,400 fpm), probe-dependent |
| Accuracy | ±3% of reading ±0.1 m/s (±20 fpm) |
| Operating Temperature | 5–40 °C (41–104 °F) |
| Display | Built-in LCD |
| Analog Output Options | 0–5 V DC, 0–1 V DC, or 4–20 mA (switch-selectable) |
| Power Supply | DC 12 V ±2 V |
| Dimensions | 128 × 78 × 30 mm |
| Weight | 320 g |
| Probe Compatibility | 10 interchangeable hot-wire probes (e.g., 6332-01 to 6332-10) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6332D |
| Instrument Type | Hot-Wire Anemometer |
| Measurement Range | 0.1–50 m/s (9–8,400 fpm), probe-dependent |
| Accuracy | ±3% of reading ±0.1 m/s (±20 fpm) |
| Operating Temperature | 5–40 °C (41–104 °F) |
| Display | Built-in LCD |
| Output Options | Switch-selectable 0–5 V DC, 0–1 V DC, or 4–20 mA |
| Power Supply | DC 12 V ±2 V |
| Dimensions | 128 × 78 × 30 mm |
| Weight | 320 g |
| Probe Compatibility | Supports 10 interchangeable hot-wire and thermal anemometry probes |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6332D |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.1–50 m/s (9–8,400 fpm), probe-dependent |
| Accuracy | ±3% of reading ±0.1 m/s (±20 fpm) |
| Operating Temperature | 5–40 °C (41–104 °F) |
| Display | Integrated LCD |
| Output Options | Switch-selectable 0–1 V DC, 0–5 V DC, or 4–20 mA |
| Power Supply | DC 12 V ±2 V |
| Dimensions | 128 × 78 × 30 mm |
| Weight | 320 g |
| Probe Compatibility | 10 interchangeable thermal probes (sold separately) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6332D |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.1–50 m/s (9.8–9,840 fpm) depending on probe |
| Accuracy | ±3% of reading ±0.1 m/s (±20 fpm) |
| Operating Temperature | 5–40 °C (41–104 °F) |
| Display | Built-in LCD |
| Analog Output Options | 0–5 V DC, 0–1 V DC, or 4–20 mA |
| Power Supply | DC 12 V ±2 V |
| Dimensions | 128 × 78 × 30 mm |
| Weight | 320 g |
| Probe Compatibility | Interchangeable with 10 standard Kanomax thermal probes |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 6332D |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0.1–50 m/s (9–8,400 fpm), probe-dependent |
| Accuracy | ±3% of reading ±0.1 m/s (±20 fpm) |
| Operating Ambient Temperature | 5–40 °C (41–104 °F) |
| Output Options | 0–5 V DC or 4–20 mA analog output |
| Display | Integrated LCD with real-time readout |
| Probe Compatibility | Interchangeable with 10 standardized KANOMAX thermal probes (e.g., 6332-01 to 6332-10) |
| System Integration | Supports daisy-chained multi-channel configuration via analog output synchronization |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 6332D |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.1–50 m/s (9–8,400 fpm), probe-dependent |
| Accuracy | ±3% of reading ±0.1 m/s (±20 fpm) |
| Operating Ambient Temperature | 5–40 °C (41–104 °F) |
| Display | Built-in LCD |
| Analog Output Options | 0–5 V DC, 0–1 V DC, or 4–20 mA (selectable via internal DIP switches) |
| Power Supply | DC 12 V ±2 V |
| Dimensions | 128 × 78 × 30 mm |
| Weight | 320 g |
| Probe Compatibility | 10 interchangeable thermal probes (e.g., 6332-01 to 6332-10) |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China (Manufactured under Kanomax Japan technical specification & quality control) |
| Model | 6332D |
| Instrument Type | Thermal Anemometer Transmitter |
| Resolution | 0.01 m/s (dependent on probe selection) |
| Measurement Range | Probe-dependent (e.g., 0.1–30 m/s standard probes |
| Output | 4–20 mA or 0–5 V analog output |
| Display | Integrated LCD (backlit, real-time wind speed only) |
| Power Supply | DC 12 V ±2 V |
| Dimensions | 128 × 78 × 30 mm |
| Weight | 320 g |
| Probe Interface | Standardized interchangeable thermal probe socket (10 compatible probe models certified per Kanomax TS-63xx series) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6332D |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.1–50 m/s (9–8,400 fpm), probe-dependent |
| Accuracy | ±3% of reading ±0.1 m/s (±20 fpm) |
| Operating Temperature | 5–40 °C (41–104 °F) |
| Analog Output Options | 0–5 V DC, 0–1 V DC, or 4–20 mA DC (selectable via internal DIP switch) |
| Power Supply | DC 12 V ±2 V |
| Dimensions | 128 × 78 × 30 mm |
| Weight | 320 g |
| Display | Built-in LCD (real-time wind speed readout, range dependent on connected probe) |
| Probe Compatibility | Interchangeable with 10 standardized thermal probes for the 6332 series |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6332D |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0.1–50 m/s (9.8–4,840 fpm), probe-dependent |
| Accuracy | ±3% of reading ±0.1 m/s (±20 fpm) |
| Operating Temperature | 5–40 °C (41–104 °F) |
| Output Options | 0–5 V DC or 4–20 mA analog output |
| Display | Built-in LCD screen |
| Probe Compatibility | Interchangeable with 10 probe types designed for the 6332 series |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–50.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 2–98% RH (non-condensing) |
| Analog Output | 4–20 mA or 0–5 V (DIP-switch configurable) |
| Digital Output | RS-485 |
| Power Supply | AC 100–240 V / DC 12–24 V |
| Dimensions | 100 × 60 × 25 mm |
| Weight | 200 g |
| Probe Compatibility | 15 interchangeable probe models (e.g., 0972-00, 0975-31, 0976-05) with optional temperature and RH sensing |
| Response Time | ≤1 s (90% response at 1 m/s, ambient conditions) |
| Brand | Kanomax |
|---|---|
| Origin | China (Liaoning) |
| Model | 6333-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Velocity Range | 0.01–50.0 m/s (dependent on probe selection) |
| Temperature Range | 0–120 °C (probe-dependent) |
| Humidity Range | 5–95 %RH |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater), ±0.5 °C, ±3–5 %RH |
| Operating Environment | 0–60 °C, 2–98 %RH (non-condensing) |
| Storage Environment | −20–70 °C, 2–98 %RH (non-condensing) |
| Analog Output | 4–20 mA or 0–5 V (DIP-switch configurable) |
| Digital Output | RS485 |
| Power Supply | AC 100–240 V / DC 12–24 V |
| Dimensions | 100 × 60 × 25 mm |
| Weight | 200 g |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6333-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 2–98% RH (non-condensing) |
| Analog Output | 4–20 mA or 0–5 V (selectable via DIP switch) |
| Digital Output | RS-485 |
| Power Supply | AC 100–240 V / DC 12–24 V |
| Dimensions | 100 × 60 × 25 mm |
| Weight | 200 g |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6333-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Measurement Range | 0.01–50.0 m/s (dependent on probe selection) |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 2–98% RH (non-condensing) |
| Analog Output | 4–20 mA or 0–5 V (user-selectable via DIP switch) |
| Digital Output | RS-485 |
| Power Supply | AC 100–240 V / DC 12–24 V |
| Power Consumption | ~3 W (at DC 12 V, 10 m/s with probe 0976-03) |
| Dimensions | 100 × 60 × 25 mm (W × D × H) |
| Weight | 200 g |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–50.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 2–98% RH (non-condensing) |
| Analog Output | 4–20 mA or 0–5 V (DIP-switch configurable) |
| Digital Output | RS-485 |
| Power Supply | AC 100–240 V / DC 12–24 V |
| Dimensions | 100 × 60 × 25 mm |
| Weight | 200 g |
| Probe Compatibility | 15 interchangeable probe models (e.g., 0972-00, 0975-31, 0976-05) with temperature/humidity sensing options |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6333-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–50.0 m/s) |
| Measurement Range | 0.01–50.0 m/s (depending on probe model) |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| temperature accuracy | ±0.5 °C |
| RH accuracy | ±3% RH (5–80% RH), ±5% RH (80–90% RH) |
| Operating Temperature | 0–60 °C (transmitter body) |
| Operating Humidity | 2–98% RH (non-condensing) |
| Analog Output | 4–20 mA or 0–5 V (user-selectable via DIP switch) |
| Digital Output | RS-485 |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (transmitter) | 100 × 60 × 25 mm |
| Weight | 200 g |
| Brand | Kanomax |
|---|---|
| Origin | China (Liaoning Province) |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Hot-Wire Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Probe-Dependent (e.g., 0–30 m/s typical for standard probes) |
| Accuracy | ±3% of reading or ±0.015 m/s (whichever is greater) for velocity |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 0–100% RH |
| Data Storage Capacity | 20,000 records |
| Communication Interface | USB |
| Analog Output | 0–1 V |
| Power Supply | 6 × AA batteries or AC adapter |
| Dimensions | 88 × 188 × 41 mm |
| Weight | 400 g |
| Probe Compatibility | 8 interchangeable hot-wire and thermistor-based probes (including duct, vane, and omnidirectional configurations) |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China (Distributed by Authorized Kanomax Partner) |
| Model | 65 Ser |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Velocity Range | Varies by probe (e.g., 0–30 m/s standard probe) |
| Accuracy | ±2% of reading or ±0.015 m/s (whichever is greater) for velocity |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 0–100 %RH (non-condensing) |
| Data Storage | 20,000 records |
| Interface | USB |
| Analog Output | 0–1 V |
| Power | 6 × AA alkaline batteries or optional AC adapter |
| Dimensions | 88 × 188 × 41 mm |
| Weight | 400 g |
| Probe Compatibility | 8 interchangeable Kanomax-certified thermal anemometer probes |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China (Distributed under KANOMAX Japan licensing agreement) |
| Model | 65 Ser |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Velocity Range | Dependent on interchangeable probe (standard probe: 0.01–30.0 m/s) |
| Accuracy | ±2% of reading or ±0.015 m/s (whichever is greater) for velocity |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 0 to 100 %RH (non-condensing) |
| Data Storage Capacity | 20,000 records |
| Interface | USB 2.0 |
| Analog Output | 0–1 V (linear, user-configurable parameter) |
| Power Supply | 6 × AA alkaline batteries or optional AC adapter |
| Dimensions | 88 × 188 × 41 mm |
| Weight | 400 g |
| Probe Compatibility | 8 standardized KANOMAX thermal and vane probes (e.g., 6501, 6502, 6503, 6505, 6506, 6507, 6508, 6509) |
| Built-in Calculations | Air volume (m³/h, CFM) via user-defined duct geometry (rectangular, circular, oval cross-sections with dimensional input) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 65 Ser |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s (wind speed) |
| Measurement Range | Wind Speed – dependent on probe (e.g., 0.05–30 m/s with standard hot-wire probe) |
| Accuracy | Wind Speed – ±2% of reading or ±0.015 m/s (whichever is greater) |
| Operating Environment | −20 to +70 °C, 2.0–98.0 % RH |
| Data Storage | 20,000 records |
| Interface | USB |
| Analog Output | 0–1 V |
| Power | 6 × AA batteries or AC adapter |
| Dimensions | 88 × 188 × 41 mm |
| Weight | 400 g |
| Probe Compatibility | 8 interchangeable thermal anemometer probes (including vane, hot-wire, and duct-specific configurations) |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China (Distributed by Authorized Domestic Partner) |
| Model | 65 Ser |
| Instrument Type | Hot-Wire Anemometer |
| Resolution | 0.01 m/s |
| Velocity Range | Dependent on Interchangeable Probe Selection |
| Accuracy | ±3% of reading or ±0.015 m/s (whichever is greater) |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±0.5 °C |
| Humidity Range | 2.0–98.0 %RH |
| Humidity Accuracy | ±2.0 %RH (2–80 %RH), ±3.0 %RH (80–98 %RH) |
| Pressure Range | ±5.00 kPa |
| Pressure Accuracy | ±3% of reading |
| Operating Humidity | 0–100 %RH |
| Data Storage Capacity | 20,000 records |
| Interface | USB |
| Analog Output | 0–1 V |
| Power Supply | 6 × AA batteries or AC adapter |
| Dimensions | 88 × 188 × 41 mm |
| Weight | 400 g |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 65 Series |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s (wind speed) |
| Measurement Range | Wind Speed – dependent on probe selection (e.g., 0.01–30 m/s typical for cleanroom probes) |
| Temperature | –20 to +70 °C |
| Relative Humidity | 2.0–98.0 % RH |
| Differential Pressure | ±5.00 kPa |
| Accuracy | Wind Speed: ±2% of reading or ±0.015 m/s (whichever is greater) |
| Temperature | ±0.5 °C |
| Humidity | ±2.0 % RH (2–80 % RH), ±3.0 % RH (80–98 % RH) |
| Pressure | ±3% of reading |
| Operating Environment | –20 to +70 °C, 2.0–98.0 % RH |
| Data Storage Capacity | 20,000 records |
| Communication Interface | USB |
| Analog Output | 0–1 V |
| Power Supply | 6 × AA alkaline batteries or optional AC adapter |
| Dimensions | 88 × 188 × 41 mm |
| Weight | 400 g |
| Probe Compatibility | 8 interchangeable thermal anemometer probes (e.g., straight, bent, retractable, multi-point array) |
| Data Functions | Real-time hold, statistical calculation (mean, max, min), cross-sectional area input for volumetric airflow derivation |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 65 Series |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.01–50.0 m/s |
| Velocity Accuracy | ±2% of reading or ±0.015 m/s (whichever is greater) |
| Temperature Range | −20–70 °C |
| Temperature Accuracy | ±0.5 °C |
| Humidity Range | 2.0–98.0 %RH |
| Humidity Accuracy | ±2.0 %RH (2–80 %RH), ±3.0 %RH (80–98 %RH) |
| Pressure Range | ±5.00 kPa |
| Pressure Accuracy | ±3% of reading |
| Resolution | 0.01 m/s (velocity), 0.1 °C (temperature), 0.1 %RH (humidity), 0.01 kPa (pressure) |
| Data Storage Capacity | 20,000 records |
| Interface | USB |
| Analog Output | 0–1 V |
| Power Supply | 6 × AA batteries or AC adapter |
| Dimensions | 88 × 188 × 41 mm |
| Weight | 400 g |
| Probe Compatibility | 8 interchangeable probe types |
| Operating Environment | −20–70 °C, 2.0–98.0 %RH |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Dependent on Interchangeable Probe Model |
| Accuracy | ±2% of Reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | Up to 20,000 Records |
| Probe Compatibility | 8 Standard KANOMAX Thermal Probes (e.g., 6501, 6511, 6521, 6531, etc.) |
| Built-in Functions | Real-time Hold, Statistical Calculation (Mean, Max, Min), Cross-sectional Area Input for Volumetric Flow Derivation |
| Included Accessories | 2-m Probe Cable ×1, Carrying Case ×1, User Manual |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Dependent on Interchangeable Probe Model |
| Accuracy | ±2% of reading |
| Operating Temperature | −20 °C to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | Up to 20,000 records |
| Probe Compatibility | 8 interchangeable thermal anemometer probes |
| Built-in Calculations | Air velocity → volumetric flow (with user-defined duct geometry), min/max/avg statistics |
| Display | Simultaneous real-time readout of air velocity, volumetric flow, temperature, relative humidity, and differential pressure |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Dependent on Interchangeable Probe Model |
| Accuracy | ±2% of Reading |
| Operating Temperature | –20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | Up to 20,000 Records |
| Probe Interface | Standardized 8-Model Hot-Wire Probe Compatibility |
| Built-in Functions | Data Hold, Statistical Calculations (Mean, Max, Min), Cross-Sectional Area Input for Volumetric Flow Derivation |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Dependent on Interchangeable Probe (e.g., 0.01–30 m/s typical for standard hot-wire probes) |
| Accuracy | ±2% of reading |
| Operating Temperature | –20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | Up to 20,000 records |
| Probe Interface | 8 interchangeable probe types supported |
| Built-in Calculations | Air volume (based on user-defined duct geometry and cross-sectional area), average/min/max statistics |
| Environmental Compliance | Designed for field and laboratory use under ISO 7726, ASTM D1078, and EN 13790-compliant airflow assessment conditions |
| Power | Rechargeable Li-ion battery (typical operation time ≥12 h) |
| Display | Backlit high-contrast LCD with simultaneous multi-parameter readout (velocity, temperature, humidity, differential pressure, volumetric flow) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Hot-Wire Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Dependent on Interchangeable Probe Model |
| Accuracy | ±2% of reading |
| Operating Temperature | –20 °C to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | 20,000 records |
| Probe Interface | Standardized 8-way modular connector |
| Built-in Calculations | Airflow (m³/h or CFM) via user-defined duct geometry (rectangular, circular, oval), statistical functions (min/max/avg), data hold |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 65Ser |
| Instrument Type | Thermal Anemometer |
| Resolution | ±2% of reading |
| Velocity Range | 0.01–50.0 m/s |
| Humidity Accuracy | ±2% RH (2–80% RH), ±3.0% RH (80–98% RH) |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | Up to 20,000 records |
| Probe Compatibility | 8 interchangeable Kanomax probe types |
| Flow Calculation | Supports user-defined duct geometry (rectangular, circular, oval) for volumetric air flow derivation |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Measurement Principle | Constant-Temperature Anemometry (CTA) |
| Resolution | 0.01 m/s |
| Accuracy | ±2% of reading |
| Temperature Range | −20 to +70 °C |
| Relative Humidity Range | 2.0–98.0% RH |
| Data Storage Capacity | Up to 20,000 records |
| Probe Compatibility | 8 interchangeable thermal probes (plug-and-play interface) |
| Built-in Functions | Real-time hold, statistical calculation (mean, min, max), cross-sectional area input for volumetric flow derivation |
| Environmental Compliance | Designed for indoor air quality (IAQ), HVAC commissioning, and cleanroom validation per ISO 14644-3 and ASHRAE Standard 111 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Dependent on Interchangeable Probe (e.g., 0.01–30 m/s typical for standard hot-wire probes) |
| Accuracy | ±2% of reading |
| Operating Temperature | –20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | Up to 20,000 records |
| Probe Compatibility | 8 interchangeable probe types (hot-wire, vane, pitot tube, and specialized duct/hood probes) |
| Built-in Environmental Sensors | Air velocity, volumetric flow rate, temperature, relative humidity, differential pressure |
| Real-time Calculations | Flow rate (m³/h, CFM) via user-defined duct cross-section geometry (rectangular, circular, oval) |
| Statistical Functions | Min/Max/Avg hold, live statistics |
| Data Retention | Hold function with auto-capture trigger |
| Accessories Included | 2 m probe cable, carrying case, operation manual |