KANOMAX
Filter
Showing 241–270 of 500 results
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 29 CFR 1910.134, CSA Z94.4, EN 13274-1/EN 13274-7 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Accuracy | ±2.5% |
| Sampling Principle | Andersen Impaction (6-stage cascade impactor) |
| Impact Velocity | <20 m/s |
| Sampling Volume Range | 20–6000 L |
| Interval Time | 10 s–1 h |
| Delay Time | 0 s–23 h 59 min 59 s |
| Sampling Cycles | 2–300 or continuous |
| Petri Dish Compatibility | 90–100 mm and 55–84 mm |
| Exhaust Filter Class | ISO Class 3 |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV format) |
| Communication | USB, RS-485 (Modbus RTU) |
| Power Supply | Li-ion rechargeable battery (7 h operation) + AC 100–240 V adapter |
| Operating Environment | 0–40 °C, 0–90% RH (non-condensing) |
| Weight | 3.2 kg |
| Dimensions | 136 × 235 × 133 mm |
| User Management | 64 editable users with multi-level permission control and audit trail |
| Remote Control | IR remote (supports up to 5 units simultaneously) |
| Language Support | English, Japanese, Chinese |
| Alarm | Visual & audible flow deviation alert |
| Materials | 316 stainless steel sampling head |
| Compliance | Designed for ISO 14698-1, ISO 14644-1/2, EU GMP Annex 1, USP <1116>, and FDA 21 CFR Part 11-ready data integrity architecture |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Dependent on Interchangeable Probe (e.g., 0.05–30 m/s for standard hot-wire probe) |
| Accuracy | ±2% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | Up to 20,000 records |
| Probe Interface | Standardized 8-pin detachable connector supporting eight interchangeable probe types |
| Built-in Calculations | Volumetric airflow (m³/h, CFM) via user-defined duct geometry (rectangular, circular, oval cross-sections with dimensional input) |
| On-device Statistics | Real-time min/max/average of velocity, temperature, humidity, and pressure |
| Data Hold & Recall | Instant freeze-display and historical retrieval |
| Accessories Included | 2 m probe cable ×1, carrying case ×1, operation manual ×1 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | BubbleMaster |
| Sensor Type | Optical Fiber (Wedge-Tip, F-Top Configuration) |
| Measurement Principle | Optical Intensity Modulation at Bubble-Transit Interface |
| Output | Individual Bubble Diameter & Transit Velocity |
| Fluid Compatibility | Electrically Insulating Liquids |
| Compliance | Designed for Research-Grade Bubble Characterization in Nuclear and Chemical Engineering Environments |
| Price Range | USD 13,500 – 40,500 (FOB Japan) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | Cabin Seal Tester |
| Pressure Range | ±2500 Pa |
| Leakage Flow Measurement Range | 1–200 L/s |
| Compliance | Designed for ISO 9001-aligned automotive HVAC & body-in-white validation workflows |
| Software Interface | PC-based control with real-time pressure/flow logging |
| Data Export | CSV, Excel-compatible format |
| Regulatory Context | Supports GLP-aligned test documentation per IATF 16949 and JIS D 0201-2018 (Automotive Interior Air Leakage) |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | CRMS |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Online Continuous Monitoring System |
| Flow Rate | High-Flow (1 CFM / 28.3 L/min and 0.1 CFM / 2.83 L/min options) |
| Flow Accuracy | < ±1 count per 5 min |
| Timing Accuracy | ±1 s within 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Particle Size Distribution Error | ≤ ±30% |
| Indication Error | < ±30% FS |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | T6900 |
| Flow Range (Matrix) | 36–640 m³/h |
| Flow Range (Nozzle) | 4–36 m³/h |
| Flow Accuracy | ±2.5% of reading ±0.1 m³/h |
| Flow Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Barometric Pressure Range | 70–130 kPa |
| Barometric Accuracy | ±2% of reading |
| Barometric Resolution | 0.1 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions (W×D×H) | 54 × 50 × 120 cm |
| Data Storage | 1000 test records |
| Display | 5-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DAL T6900 |
| Price | Upon Request |
| Flow Range | 36–640 m³/h (main duct) / 4–36 m³/h (nozzle bank) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DAL T6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DAL T6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DAL T6900 |
| Flow Range | 36–640 m³/h (nozzle mode: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DAL T6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DAL T6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DAL T6900 |
| Flow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DAL T6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DAL T6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DAL T6900 |
| Flow Range (Matrix) | 36–640 m³/h |
| Flow Range (Nozzle) | 4–36 m³/h |
| Flow Accuracy | ±2.5% of reading ±0.1 m³/h |
| Flow Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Barometric Pressure Range | 70–130 kPa |
| Barometric Accuracy | ±2% of reading |
| Barometric Resolution | 0.1 kPa |
| Power Supply | DAL T6900-0E: 110–120 V, 1φ, 50/60 Hz, 16 A |
| DAL T6900-1E | 220–240 V, 1φ, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions (W×D×H) | 54 × 50 × 120 cm |
| Data Storage Capacity | 1000 test records |
| Brand | Kanomax |
|---|---|
| Origin | China (Liaoning) |
| Model | DALT 6900 |
| Airflow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (airflow), ±1% of reading ±1 Pa (static pressure) |
| Resolution | 0.01 m³/h (airflow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DALT 6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT 6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Brand | Kanomax |
|---|---|
| Model | DAL.T6900 |
| Origin | China (Liaoning) |
| Power Supply | DAL.T6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DAL.T6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Airflow Range | 36–640 m³/h (main duct) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (airflow) |
| Resolution | 0.01 m³/h (airflow) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Dimensions (W×D×H) | 540 × 500 × 1200 mm |
| Net Weight | ~72 kg |
| Brand | Kanomax |
|---|---|
| Model | DALT-6905 |
| Flow Range (Large Nozzle) | 70–820 m³/h |
| Flow Range (Small Nozzle) | 4–70 m³/h |
| Flow Accuracy | ±2.5% of reading ±0.1 m³/h |
| Flow Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Resolution | 0.1 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Atmos. Pressure Accuracy | ±2% of reading |
| Atmos. Pressure Resolution | 0.1 kPa |
| Power Supply | 100–120 V / 200–240 V, 1-phase, 50/60 Hz |
| Net Weight | 59.8 kg |
| Dimensions (W×D×H) | 480 × 627 × 1124 mm |
| Data Storage | 1000 test records |
| Display | 5-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2003, Eurovent 2/2, DW/143, SMACNA, AABC, GB 50243–2002/2016 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Flow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Flow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Flow Range | 36–640 m³/h (nozzle mode: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Flow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | KANOMAX |
|---|---|
| Model | DALT6900 |
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Flow Range | 36–640 m³/h (main duct), 4–36 m³/h (nozzle bank) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Dimensions | 540 × 500 × 1200 mm |
| Net Weight | ~72 kg |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Price | Upon Request |
| Flow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h |
| Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Resolution | 0.1 °C |
| Barometric Pressure Range | 70–130 kPa |
| Baro Accuracy | ±2% of reading |
| Baro Resolution | 0.1 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | DALT6900 |
| Price | Upon Request |
| Flow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h |
| Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Resolution | 0.1 °C |
| Barometric Range | 70–130 kPa |
| Baro Accuracy | ±2% of reading |
| Baro Resolution | 0.1 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Flow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Flow Range (Matrix) | 36–640 m³/h |
| Flow Range (Nozzle) | 4–36 m³/h |
| Flow Accuracy | ±2.5% of reading ±0.1 m³/h |
| Flow Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Barometric Pressure Range | 70–130 kPa |
| Barometric Accuracy | ±2% of reading |
| Barometric Resolution | 0.1 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions (W×D×H) | 54×50×120 cm |
| Data Storage | 1000 test records |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Flow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h |
| Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Resolution | 0.1 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Atmos. Acc. | ±2% of reading |
| Atmos. Res. | 0.1 kPa |
| Power Supply | DALT6900-0E: 100–120 V, 1φ, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1φ, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Pricing | Upon Request |
| Flow Range | 36–640 m³/h (main channel), 4–36 m³/h (nozzle bank) |
| Flow Accuracy | ±2.5% of reading ±0.1 m³/h |
| Flow Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Resolution | 0.1 °C |
| Barometric Pressure Range | 70–130 kPa |
| Baro Accuracy | ±2% of reading |
| Baro Resolution | 0.1 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions (W×D×H) | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | DALT6900 |
| Flow Range (Matrix) | 36–640 m³/h |
| Flow Range (Nozzle) | 4–36 m³/h |
| Flow Accuracy | ±2.5% of reading ±0.1 m³/h |
| Flow Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Barometric Pressure Range | 70–130 kPa |
| Barometric Accuracy | ±2% of reading |
| Barometric Resolution | 0.1 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions (W×D×H) | 54 × 50 × 120 cm |
| Data Storage Capacity | 1000 test records |
| Brand | Kanomax |
|---|---|
| Model | DALT6900 |
| Flow Range (Matrix) | 36–640 m³/h |
| Flow Range (Nozzle) | 4–36 m³/h |
| Flow Accuracy | ±2.5% of reading ±0.1 m³/h |
| Flow Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Resolution | 0.1 °C |
| Barometric Pressure Range | 70–130 kPa |
| Baro Accuracy | ±2% of reading |
| Baro Resolution | 0.1 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions (W×D×H) | 54×50×120 cm |
| Data Storage | 1000 test records |
| Display | 5-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Pricing | Available Upon Request |
| Flow Range (Matrix) | 36–640 m³/h |
| Flow Range (Nozzle) | 4–36 m³/h |
| Flow Accuracy | ±2.5% of reading ±0.1 m³/h |
| Flow Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Barometric Pressure Range | 70–130 kPa |
| Barometric Accuracy | ±2% of reading |
| Barometric Resolution | 0.1 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions (W×D×H) | 54 × 50 × 120 cm |
| Data Storage Capacity | 1000 test records |
| Brand | Kanomax |
|---|---|
| Model | DALT6900 |
| Origin | China (Liaoning) |
| Power Supply | DALT6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Airflow Range | 36–640 m³/h (main channel), 4–36 m³/h (nozzle bank) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (airflow) |
| Resolution | 0.01 m³/h (airflow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Dimensions | 540 × 500 × 1200 mm |
| Net Weight | ~72 kg |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Construction Standards, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Flow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |