Labsphere
Filter
Showing 61–90 of 94 results
| Brand | Labsphere |
|---|---|
| Model | RSA-REF-50-DB |
| Illumination Geometry | 8°/h (8° illumination, hemispherical detection) |
| Sphere Diameter | 50 mm |
| Light Source | Integrated Tungsten-Halogen or Optional LED Module |
| Fiber Optic Interface | SMA 905 |
| Compliance | ISO/CIE Compliant Optical Design |
| Origin | Shanghai, China |
| Distribution Status | Authorized Distributor |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | RT-060-SF, RT-060-IG, RTC-060-SF, RTC-060-IG |
| Coating Options | Spectraflect® (300–2400 nm), Infragold® (0.7–20 µm) |
| Port Configuration | Five 1-inch ports (RT) |
| Detector Port | 0.5-inch (top-mounted for RT, bottom-mounted for RTC) |
| Mirror Trap | Integrated specular beam trap |
| Sample Mounting | Adjustable center-stage (RTC), dual 1-inch sample holders (RT), optional jaw-type / clamp-type / slot-type fixtures |
| Compliance | Designed for ASTM E1331, ISO 9050, CIE No. 15, USP <857>, and GLP/GMP-aligned measurement workflows |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | RT-060-SF/IG, RTC-060-SF/IG |
| Coating Options | Spectraflect® (300–2400 nm), Infragold® (0.7–20 µm) |
| Port Configuration | Five 1-inch ports, top 0.5-inch detector port, bottom detector port (RTC only), specular beam trap, knife-edge port geometry, minimized baffle design |
| Compliance | Designed for ASTM E1331, ISO 13468, ISO 13469, CIE No. 15, USP <1061>, and GLP-compliant optical characterization workflows |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | RT/RTC |
| Coating Options | Spectraflect® (300–2400 nm), Infragold® (0.7–20 µm) |
| Configuration | RT (fixed 9°/h geometry), RTC (motorized or manual variable-angle sample stage) |
| Detector Port | Top (RT), Bottom (RTC) |
| Standard Aperture | Five 1-inch ports + 0.5-inch detector port |
| Mirror Trap | Integrated specular beam trap |
| Baffle Design | Low-profile, minimized obstruction for maximal wall visibility |
| Entrance Geometry | Knife-edge apertures for wide-angle scatter collection |
| Compliance | ASTM E1331, ISO 9050, ISO 13468, ISO 14782, CIE 110, USP <857>, FDA 21 CFR Part 11 (with optional software audit trail) |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SPECTRA-CT |
| Light Source Type | Tunable Broadband LED-Based Integrating Sphere Source |
| Illumination Method | Internal Illumination |
| Key Dimensions (CT-1000-S / M / L) | 20/30/50 cm sphere diameter |
| Output Aperture | 5/10/20 cm |
| Spectral Range | UV-Vis-NIR (250–1700 nm) |
| Luminance Range | 0.1–500,000 cd/m² (model-dependent) |
| Uniformity | >99% (per EMVA 1288 Annex A) |
| Color Temperature Range | 2800–7500 K |
| CCT Uniformity | ±15 K |
| Short-Term Stability | ±0.1% over 10 min |
| Warm-up Time | ≤30 s |
| Monitoring Sensor | Integrated Silicon Photodiode |
| Control Interface | USB + Ethernet |
| Software SDK | Yes (C/C++, Python, LabVIEW compatible) |
| Compliance | Fully supports EMVA 1288:2016 for camera characterization |
| Brand | Labsphere |
|---|---|
| Model | Spectra-FT |
| Origin | USA |
| Light Source Type | Tungsten-Halogen & LED Hybrid Spectral Engine |
| Spectral Range | 390–1000 nm |
| Luminance Range | 10–25,000 cd/m² |
| Field Uniformity | >98% over 360° × 200° FOV |
| Calibration Traceability | NIST-traceable spectral radiance |
| Feedback System | Integrated spectroradiometric real-time feedback loop |
| Re-calibration | User-executable via SpectraSoft™ v4.2 |
| Compliance | ASTM E308, ISO/CIE 11664, USP <1033>, FDA 21 CFR Part 11 (audit trail enabled) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Spectra-FT VIS-NIR |
| Output Aperture | 75 mm (Ø) |
| Spectral Range | 380–1050 nm |
| Max Luminance | 25,000 cd/m² |
| LED Channels | 32 |
| Uniformity | >98% over 360° × 200° FOV |
| Integrated Spectrometer | Yes |
| Compliance | ISO/IEC 17025 traceable calibration support, NIST-traceable spectral radiance characterization available |
| Software Control | USB/Ethernet, Labsphere SpectraSuite™ v5.0+ with real-time feedback loop |
| Operating Temperature Stability | ±0.1°C active thermal regulation |
| Radiometric Accuracy | ±2.5% (k=2, 380–950 nm, relative to NIST SRM) |
| Brand | Labsphere |
|---|---|
| Model | Spectra-PT |
| Origin | USA |
| Light Source Type | Integrating Sphere-Based Uniform Radiance/Luminance Source |
| Sphere Diameter | 13.5 cm |
| Output Port Diameter | 5 cm |
| Variable Aperture | Motorized, Precision Automatic (VA) |
| Built-in Reference Photodetector | Yes |
| Luminance Range | 0.01–50,000 cd/m² (continuous, programmable) |
| Spectral Output | Broadband (Xenon or Mercury-based, configurable) |
| Calibration | NIST-traceable spectral radiance and luminance |
| Compliance | ISO/IEC 17025-accredited calibration certificate included |
| Software Interface | LabVIEW-compatible, USB/Ethernet control, GUI for preset definition and real-time monitoring |
| Form Factor | Integrated benchtop enclosure with mobility handles |
| Optional Configuration | Wide-Angle Field-of-View (WAF) version available for >180° FOV imaging systems |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Spectra-PT |
| Type | Integrating Sphere-Based Uniform Light Source for Photometric and Radiometric Calibration |
| Compliance | NIST-traceable calibration options available |
| Control Interface | Analog 0–10 V and digital RS-232/USB |
| Dynamic Range | >10⁶:1 (typical, dependent on detector and configuration) |
| Spectral Range | 350–1000 nm (standard halogen/tungsten-halogen lamp configuration) |
| Uniformity | ≥98% spatial uniformity over output port (per ISO 9050 and CIE S 023) |
| Stability | <0.2% RMS over 30 min (thermal + power supply stabilized) |
| Port Diameter | 4", 6", or 8" (configurable) |
| Lamp Life | ≥2000 h (rated at nominal voltage) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | SPECTRA-QT |
| Pricing | Available Upon Request |
| Spectral Irradiance Range | 375–1100 nm |
| Spectral Bandwidth | 5–10 nm |
| Wavelength Accuracy | ±0.6 nm |
| Aperture Diameters | 22 mm, 23.9 mm, 26.2 mm, 29 mm |
| Max Spectral Irradiance (400 nm) | 12 μW/cm²/nm |
| Max Spectral Irradiance (600 nm) | 21 μW/cm²/nm |
| Max Spectral Irradiance (800 nm) | 5 μW/cm²/nm |
| Max Spectral Radiance (400 nm) | 32 μW/cm²·sr·nm |
| Max Spectral Radiance (600 nm) | 54 μW/cm²·sr·nm |
| Max Spectral Radiance (800 nm) | 11 μW/cm²·sr·nm |
| UV-VIS Stability (550 nm) | <1.5% over 5 s |
| VIS-NIR Stability (750 nm) | <0.05% over 5 s |
| NIST-Traceable Calibration | Yes |
| Software Development Kit (SDK) | Included |
| Brand | Labsphere |
|---|---|
| Model | Spectra-UT |
| Origin | USA |
| Light Source Type | Tunable Hyperspectral Source with Integrated Tungsten-Halogen (QTH) Reference Lamp and Onboard Spectrometer |
| Spectral Range | 380–780 nm (Visible) |
| Spectral Resolution | Adjustable down to ~10 nm FWHM |
| Output Uniformity | >98% over 50 mm Ø field (flat-field compliant) |
| Control Interface | USB 2.0 + Ethernet |
| Software | SpectraSoft v4.x (Windows-based, supports scripting via Python API) |
| Calibration Traceability | NIST-traceable via integrated QTH lamp and factory-characterized spectrometer |
| Compliance | ISO/IEC 17025–accredited calibration documentation available |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Cooling | Forced-air thermal management system |
| Dimensions | 320 × 240 × 180 mm (W × D × H) |
| Weight | 8.2 kg |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Spectra-UT |
| Light Source Type | Tunable Solid-State Spectral Source |
| Illumination Mode | External Illumination |
| Spectral Range | 390–780 nm |
| FWHM | 12 nm ± 2 nm |
| Peak Wavelength Spacing | 0.4 nm |
| Spectral Accuracy | < 0.5 nm |
| Max Luminance | 1000 cd/m² |
| Luminance Adjustment Range | 25–1000 cd/m² |
| Luminance Uniformity | ≥99% |
| Max Spectral Scan Rate | < 1.0 spectrum/sec |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | SpectraBlack |
| Reflectance Range | <5% (250–2500 nm) |
| Surface Type | Micro-porous engineered matte black |
| Compliance | ISO 13694, ASTM E275, NIST-traceable calibration available |
| Material Composition | Carbon-loaded polymer composite with controlled pore structure |
| Operating Temperature | –40°C to +85°C |
| Durability | Abrasion-resistant, non-outgassing, low particulate shedding |
| Brand | Labsphere |
|---|---|
| Model | SPECTRAFLECT |
| Origin | USA |
| Base Material | Barium Sulfate (BaSO₄) with Proprietary Binder System |
| Spectral Range | 300–2400 nm |
| Average Diffuse Reflectance (400–700 nm) | 96–98% |
| Lambertian Character | >99.5% (cosine angular response) |
| Thermal Stability | Up to 100 °C |
| Laser Damage Threshold | 1.7 J/cm² (at 1064 nm, 10 ns pulse) |
| Application Method | Air-spray or HVLP spray |
| Substrate Compatibility | Aluminum, stainless steel, anodized metals, ceramics, and machined polymers |
| Compliance | RoHS-compliant, non-toxic, solvent-based formulation (proprietary low-VOC carrier) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Spectralon |
| Reflectance | >99% (400–1500 nm), >95% (250–2500 nm) |
| Lambertian Character | Excellent |
| Chemical Stability | Inert |
| Thermal Stability | High |
| UV Resistance | Certified for Space-Grade Exposure |
| Compliance | NASA/JPL, GSFC, TRW, CSEM Qualified |
| Form Factor | Custom-Machinable Solid PTFE-Based Material |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RTC |
| Price Range | USD $0 – $50,000 |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Spectralon® |
| Material | PTFE-based sintered polymer |
| Spectral Range | 250–2500 nm |
| Reflectance Options | 2%, 5%, 10%, 20%, 25%, 40%, 50%, 60%, 75%, 80%, 99% |
| Spectral Flatness | ±1% (400–1500 nm), ±4% (250–2500 nm) |
| Lambertian Character | >99.9% |
| Calibration Traceability | NIST-traceable |
| Physical Form | Circular disk (1.25″ or 2.00″ diameter) |
| Packaging | Polyoxymethylene (POM) protective case with lid |
| Compliance | ASTM E259, ISO 13468-2, USP <857> |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Spectralon® Target Board |
| Calibration Range | 250–2500 nm (NIST-traceable) |
| Reflectance Options | 2% to 99% |
| Standard Mounting Frame | Anodized Aluminum (Rough Surface Finish) |
| Dimensions Available | 2×2 in to 24×24 in |
| Thickness | 0.65 in |
| Thermal & Chemical Stability | High |
| Cleanability | Water-rinsable |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SRT |
| Pricing | Available Upon Request |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TOCS-20 |
| Pricing | Available Upon Request |
| Integration Options | 0.5 m, 1.0 m, 1.65 m, and 2.0 m integrating sphere configurations |
| Standards Compliance | IESNA LM-79-19, LM-80-15 |
| Thermal Control | Integrated TEC-based temperature stabilization with real-time junction/substrate temperature monitoring |
| Electrical Measurements | Current (I), Voltage (V), Electrical Power (P) |
| Photometric Measurements | Luminous Flux (lm), Luminous Efficacy (lm/W), Chromaticity Coordinates (CIE 1931 x,y |
| Thermal-Optical-Electrical Correlation | Simultaneous acquisition of L, V, I, and T under controlled thermal boundary conditions |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Price Range | USD 28,000 – 42,000 |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Model | Integrating Sphere Light Source |
| Luminance Range | 0–10,000 cd/m² |
| Uniformity at Port | ≥99% |
| Luminance Stability (after warm-up) | ±0.5% |
| Color Temperature Control | Software-Adjustable (2700K–6500K) |
| Real-Time Output Monitoring | Integrated photodiode feedback |
| Control Interface | USB/Ethernet with SDK for custom integration |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | USS-1200LL |
| Pricing | Upon Request |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | USS-2000C |
| Calibration | NIST-traceable certificate included |
| Output Control | 0–100% continuous electronic dimming |
| Configurable Aperture Sizes | 2", 4", 6", 8", 12" (standard options) |
| Spectral Monitoring Options | Integrated Si, InGaAs, and UV-enhanced photodiode detectors for broadband radiometric coverage (200–1700 nm) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | UV-2000F |
| Instrument Type | Benchtop |
| Wavelength Range | 250–450 nm |
| Optical Resolution | ±1 nm |
| Measurement Area | 0.67 cm² |
| Dynamic Range | 2.7 AU |
| Light Source | Pulsed Xenon Flash Lamp |
| Detector | Custom Concave Holographic Grating Diode Array Spectrometer |
| Compliance Standards | AS/NZS 4399:2017, EN 13758-1:2007, AATCC TM183-2014, GB/T 18830:2009, JIS L 1096 & JIS L 1925 |
| Software Platform | Windows XP/7 Compatible, FDA 21 CFR Part 11–Ready Audit Trail Mode (Optional), GLP/GMP-Compliant Reporting |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | UV-2000S |
| Instrument Type | Benchtop |
| Wavelength Range | 250–450 nm |
| Measurement Speed | <5 seconds per sample |
| Compliance | COLIPA UVA-PF, ISO 24443:2012, FDA 2011 Sunscreen Final Rule, Revised Boots Star Rating |
| Optical Configuration | Double-beam spectrophotometric transmittance system with integrating sphere detection |
| Sample Platform | Manual precision XYZ stage with pre- and post-irradiation baseline capture |
| Calibration Standards | NIST-traceable wavelength and transmittance standards covering six critical UV bands |
| Software | UV-2000S Control & Analysis Suite (v5.x) with 21 CFR Part 11-compliant audit trail and electronic signature support |
| Ozone Generation | None |
| Fluorescence Interference Rejection | Enabled via spectral deconvolution algorithm |
| Brand | Labsphere |
|---|---|
| Model | UV1800F |
| Wavelength Range | 250–450 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth (FWHM) | < 4 nm |
| Wavelength Step | 1 nm |
| Optical Geometry | d/0 (diffuse illumination / 0° viewing) with integrating sphere |
| Sphere Port Diameter | 1.27 cm |
| Sample Illuminated Area | 1.26 cm² |
| Light Source | Pulsed Xenon Lamp |
| UV Dose per Measurement | < 0.2 J/cm² |
| Transmittance Range | 0–100% |
| Absorbance Range | 0–2.2 AU |
| UPF Range | 1–200+ |
| Compliance Standards | AS/NZS 4399:2017, EN 13758-1:2007, AATCC TM183:2020, GB/T 18830:2009, JIS L 1925:2019 |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | UV2000 |
| Instrument Type | Benchtop |
| Wavelength Range | 250–450 nm |
| Light Source | Pulsed Xenon Lamp |
| Detector | High-Performance Diode Array Spectrometer |
| Optical Integration | Spectralon® Integrating Sphere |
| Wavelength Accuracy | ±1 nm |
| Measurement Time | <5 s per sample |
| UV Band Calculation | UVA (315–400 nm), UVB (280–315 nm) |
| Compliance Standards | AS/NZS 4399:1996, EN 13758-1:2001, AATCC TM 183-2000, ISO 17166:2019, GB/T 18830, CIE S107/E |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | UV 3000S |
| Wavelength Range | 290–500 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Step | Adjustable (default 1 nm) |
| SPF Measurement Range | 0–50+ (in vitro) |
| Optical Density Dynamic Range | 3 AU |
| Compliance | ISO 24443:2021, ISO 24444:2019, COLIPA/CTFA In Vitro Guidelines, ASTM E2685 |
| Software Platform | .NET Framework®-based, Windows® 11 Compatible |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | XTH-2000C |
| Calibration Traceability | NIST-traceable Certificate Provided |
| Color Temperature Range | 3000 K to 6000 K |
| Spectral Range | 250 nm to 1100 nm |
| Output Monitoring | Integrated spectrometer and calibrated photodetector |
| Configurable Aperture Sizes | Standard options include 50 mm, 100 mm, and 200 mm exit ports |
| Control Interface | RS-232 / USB with LabSphere SpectraSuite-compatible software |