Labsphere
Filter
Showing 31–60 of 94 results
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Illumia Pro3 |
| Sphere Diameter | 50 cm |
| Spectral Range (Calibrated) | 350–1000 nm |
| Wavelength Accuracy | ±0.3 nm |
| Integration Time | 40 µs – 5 s |
| Measurement Geometry | 2π |
| Coating | Spectralect® White Diffuse Reflectance Coating |
| Software | Integral™ v5.x (with Temperature, Current & Voltage Control, Real-Time LIVT Synchronization, and GLP-Compliant Data Logging) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | illumia® Plus 2 |
| Spectrometer Options | CDS600 (200–850 nm), CDS610 (350–1000 nm), CDS2600 (325–1050 nm), CDS3020 (350–830 nm), CDS3030 (350–1100 nm) |
| Integrating Sphere Diameters | 25 cm – 195 cm |
| Coating Reflectance | 97–98% @ visible range |
| Shutter | Optional (CDS2600/CDS3020/CDS3030) |
| Compliance | IES LM-79-19, LM-78, LM-82, CIE S 025/E:2015 |
| Auto-Stability Detection | Yes |
| Report Format | Customizable Excel export with multilingual UI support |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | illumia® Pro3-UV |
| Integrating Sphere Diameter | 15 cm |
| Spectral Range (Calibrated) | 200–400 nm |
| Wavelength Accuracy | ±0.4 nm |
| Integration Time | 8 ms – 900 s |
| Spectrometer | CDS-2600-UV |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | illumia®Plus2-2600 |
| Integrating Sphere Diameter | 165 cm or 195 cm |
| Spectral Range | 325–1050 nm |
| Temperature Control Range | 15–80°C |
| Typical Ramp Rate (20→80°C) | 52 min |
| Detector | TE-cooled, back-illuminated CCD array |
| Exposure Time | 8 ms – 900 s |
| Compliance | IES LM-79-19, LM-82-12, LM-78-15, ISO/CIE S 025:2015 |
| Software | Integral® v5.x with automated stability assessment and CFR 21 Part 11-ready audit trail |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | ILT2400 UVG |
| Pricing | Available Upon Request |
| Spectral Range | 240–310 nm |
| Irradiance Range | 10 nW/cm² to 500 µW/cm² |
| Radiant Exposure (Dose) Range | 10 nJ/cm² to >1 MJ/cm² |
| Calibration | NIST-Traceable, ISO/IEC 17025:2017 Accredited |
| Detector Type | UVGI-Optimized SED240/WBS320/W Filtered Photodiode |
| Display | 4.3″ VGA Capacitive Touchscreen |
| Current Measurement Range | 50 pA – 1 mA |
| Dynamic Range | 8 decades |
| Bias Voltage | 5 V Reverse Bias |
| Internal Storage | 4 GB |
| Operating Temperature | 0–40 °C |
| Interfaces | USB Micro (data download), USB Mini (charging & remote logging via DataLight III) |
| Dimensions | 1.6″ H × 3.0″ W × 6.0″ L |
| Weight | 0.95 kg |
| Enclosure | Rugged Portable Carry Case |
| Compliance | CE (EMC Class B, no RF emissions interference) |
| Software | DataLight III (macOS & Windows compatible) |
| Sensor Connector | 15-pin D-sub |
| Application Scope | Non-pulsed UV-C sources only — low-pressure & medium-pressure mercury lamps, UVC LEDs, excimer lamps |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LCA-XXXXX-XXX |
| Price | Upon Request |
| Wavelength Range | 300–1100 nm |
| Brand | LabSphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | LF Human Eye Safety Testing Solution |
| Pricing | Available Upon Request |
| Spectralon Transmittance | 25% or 50% |
| Spectralon Target Size | 30 cm × 50 cm (customizable) |
| Spectralon Spectral Flatness | ±1.5% |
| Wavelength Range | 400–1000 nm |
| DUT-to-Target Distance | 5–30 cm |
| Maximum DUT Divergence Angle | 80° (customizable up to 120°) |
| Eye Safety Aperture | 7 mm |
| Measurement Modes | Total Radiant Power, Per-Spot Radiant Power, Spatial Distribution, Angular Emission Profile, MPE (Maximum Permissible Exposure) Compliance Assessment |
| Data Output Formats | .txt, .csv |
| Software Features | Pixel-level spot detection & centroid localization, intensity calibration with NIST-traceable reference, real-time MPE calculation per IEC 62471 and ANSI Z136.1 |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LFC |
| Pricing | Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LFC-150 |
| Integrating Sphere Diameter | 1.5 m |
| Spectral Range | 250–850 nm or 350–1000 nm (configurable) |
| Calibration Traceability | NIST-traceable |
| Compliance | LM-79, CIE 127:2007, GB/T 7922, GB/T 5702, IESNA standards |
| Measurement Modes | 2π and 4π |
| Reflectance of Sphere Coating | ≥96% (Spectralon®-equivalent 680 coating) |
| Software | LFC Control & Analysis Suite (supports ASTM E308, CIE 15:2018, CIE 13.3, and USP <1058> data handling protocols) |
| Brand | Labsphere |
|---|---|
| Model | LFFP-200-N |
| Origin | USA |
| Light Source Type | Tunable White LED Array |
| Color Temperature Range | 3000 K – 6000 K (continuously adjustable) |
| Luminance Range | 100 – 15,000 cd/m² (nit) |
| Active Emitting Area | 200 mm × 200 mm |
| Spatial Uniformity | ≥95% across active area |
| Control Interface | SDK available for C/C++, Python, LabVIEW, and .NET (English, Chinese, Japanese localizations supported) |
| Compliance | CE, RoHS, FCC Class A |
| Brand | Labsphere |
|---|---|
| Model | LFHH-1000 |
| Origin | Shanghai, China |
| Wavelength Range | 350–1050 nm |
| Spectral Resolution | ~1.5 nm |
| Signal-to-Noise Ratio | 300:1 |
| Detector | Hamamatsu S11639 CCD |
| Pixel Count | 2048 × 1 |
| Wavelength Accuracy | <0.2 nm |
| A/D Conversion | 16-bit |
| Acceptance Angle | 25° |
| Standard Reference Panel | 30 × 30 cm Spectralon® (99% reflectance, NIST-traceable options available) |
| Integration Time | 10–65 ms |
| Power Supply | Internal rechargeable Li-ion battery |
| Dimensions (L×W×H) | 17.5 × 9 × 3.5 cm |
| Weight | 1.0 kg |
| GPS Module | Integrated |
| Fiber Interface | SMA 905 compatible |
| Operating System | Android-based embedded platform |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | LFPMS |
| Pricing | Available Upon Request |
| Power Range | 100 nW – 100 W |
| Wavelength Range | 350 nm – 1800 nm |
| Calibration Traceability | National Institute of Metrology (NIM), China |
| Integrating Sphere Diameters | 2″ (5 cm), 4″ (10 cm), 6″ (15 cm), 8″ (20 cm) |
| Input Aperture | 0.5″ (12.7 mm) for LFPMS-020 |
| Coating Reflectance | ≥98% (Spectralon®-type diffuse reflectance coating) |
| Brand | LabSphere |
|---|---|
| Model | LFUSS |
| Coating | Spectraflect® or Spectralon® |
| Internal Diameter Options | 15 cm – 200 cm |
| Spectral Range | 350–2500 nm |
| Calibrated Radiance Range | 0–40,000 nit |
| Uniformity | ≥98% |
| Stability | ±0.1% |
| Light Source Type | Tungsten-halogen (150 W external + multiple internal options: 35/75/100/150 W) |
| Illumination Method | Internal illumination |
| Motorized Attenuator | ≥35,000 steps |
| Calibration Traceability | NIST and NIM (China National Institute of Metrology) |
| Operating Temperature | 20–40 °C |
| Detector Type | Silicon photodiode |
| Validated Spectral Calibration Range | 360–1100 nm |
| Color Temperature | 2856 ± 50 K |
| Aperture Configurations | Dual detector ports + variable source access ports |
| Software Compatibility | LabSphere Uniform Source Measurement Software (customizable) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LMS-3M |
| Diameter | 3 m |
| Compliance | IESNA LM-79, LM-80, ENERGY STAR® Thermal Test Requirements |
| Internal Coating | Spectraflect® (≥98% diffuse reflectance, 400–700 nm) |
| Measurement Geometry | Configurable 4π or 2π via optional baffle & port reducer |
| Detector Compatibility | Multiple photometric and spectroradiometric sensors simultaneously |
| Mounting Flexibility | Upward, downward, or axial lamp orientation |
| Temperature Control | Integrated thermal monitoring module with inlet/outlet baffles |
| Structural Assembly | Field-installed modular design (wedge segments, base frame, fasteners) |
| Dimensions (packed) | ~3.3 × 2.3 × 1.6 m per crate |
| Required Site Conditions | Level floor, structural load capacity ≥500 kg/m² |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPM |
| Coating | Infragold (700 nm – 20 µm) |
| Max Incident Power Density | 2 kW/cm² @ 10.6 µm (CW) |
| Cooling | Water-cooled (NPT 0.25", max 15 psi operating, 35 psi safety relief) |
| Detector Ports | Two standard SMA or flanged ports |
| Spectral Range | UV–Vis–NIR–MIR (compatible with Labsphere calibrated detectors) |
| Target Plate | Integrated energy-diffusing plate |
| Compliance | ASTM E275, ISO/IEC 17025-aligned calibration traceability, GLP-ready documentation support |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPMS |
| Coating Material | Infragold® |
| Cooling | Integrated Water-Cooling System |
| Spectral Range | 250 nm – 12 µm |
| Beam Acceptance Angle | Up to ±40° half-angle |
| Detector Compatibility | Dual-detector or spectrometer mounting ports |
| Thermal Management | Active water-cooling with user-selectable chiller interface |
| Target Plate | Integrated laser diffusing target plate |
| Compliance | Designed for ASTM E275, ISO/IEC 17025-aligned optical power measurement workflows |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPMS Laser Power Measurement System |
| Sphere Diameters | 2", 4", 6" |
| Detector Options | Silicon (Si), Indium Gallium Arsenide (InGaAs) |
| Spectral Range | 350–1700 nm |
| Power Range | ~1 nW to ~数百 W (dependent on configuration) |
| Calibration Traceability | NIST-traceable |
| Coating Materials | Spectraflect®, Infragold®, or Spectralon® |
| Input Port Angle | 45° relative to detector axis |
| Metrics Reported | Average Radiant Power (CW), Average Peak Radiant Power (Pulsed), COV (CW), Sampling Rate (Hz), Scan Interval (s), Power Density (W/cm²), Max/Min CW Power, Overrange Alert, Pulse Width, Repetition Rate, Standard Deviation (CW), System Responsivity Thresholds (min/max), Total Measurement Time, Pulse Count, Wavelength Selection (user-defined per calibration data) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPMS System |
| Spectral Range | 350–1700 nm (Si & InGaAs detectors) |
| Integrating Sphere Diameters | 2", 4", 6" |
| Coating Options | Spectraflect®, Spectralon®, Infragold® |
| Detector Options | Silicon (Si), Indium Gallium Arsenide (InGaAs) |
| Power Range | ~1 nW to >100 W (configuration-dependent) |
| Input Port Angle | 45° off-axis |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPMS-020-XX-YY |
| Coating Options | Spectraflect® (SF), Spectralon® (SL), Infragold® (IG) |
| Detector Options | Silicon (Si), Germanium (Ge), Indium Gallium Arsenide (InGaAs) |
| Spectral Range | 200 nm – 12 µm |
| Maximum Input Angle Acceptance | ±40° half-angle |
| Cooling Options | Air-cooled, Water-cooled, or Custom Thermal Management |
| Compliance | ASTM E275, ISO/IEC 17025-compatible calibration traceable to NIST |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPMS-1 |
| Detector Type | Calibrated Photodiode or Thermopile Sensor |
| Spectral Range | Customizable (e.g., 190–1100 nm or 800–1800 nm) |
| Power Range | 100 µW to 100 W (CW), up to 1 kW peak (pulsed, with appropriate attenuation) |
| Input Port Diameter | 25 mm, 50 mm, or 100 mm (configurable) |
| Coating | Spectralon® or custom diffuse reflectance coating (≥99% uniform reflectance) |
| Calibration Traceability | NIST-traceable |
| Compliance | ISO/IEC 17025 accredited calibration available |
| Software Interface | USB 2.0, compatible with Windows-based LPMS Control & Analysis Suite |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPS |
| Coating Options | Spectraflect®, Infragold®, Spectralon® |
| Wavelength Range | UV–Vis–NIR–MIR (200 nm – 12 µm) |
| Beam Acceptance Angle | Up to ±40° half-angle |
| Detector Compatibility | Dual-detector or spectrometer integration supported |
| Cooling Options | Air-cooled and water-cooled configurations available |
| Target Plate | Integrated laser beam diffuser plate |
| Thermal Management | Optimized heat dissipation architecture for high-power operation |
| Compliance | Designed for ASTM E275, ISO/IEC 17025-aligned calibration workflows |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LS-LED-Production |
| Uniformity (Exit Port) | ≥98% |
| Exit Port Diameter | 45 mm |
| CCT Tuning Range | Adjustable Continuous from Warm to Cool White (Typ. 2700 K – 6500 K) |
| Illuminance Tuning Range | Continuously Adjustable (0–10,000 lx typical at port) |
| Control Resolution | Millisecond-level Setpoint Response |
| Power Supply | Integrated Multi-channel Constant-Current LED Drivers |
| Monitoring | Real-time Photometric Feedback (Illuminance, LED Forward Voltage/Current Decay) |
| Compliance | Designed for ISO/IEC 17025-compliant calibration workflows |
| Optional Add-on | Spectral Monitoring Module (VIS, 380–780 nm) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PFT |
| Pricing | Available Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PERMAFLECT® |
| Price Range | USD $0–$7,200 (est.) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | PT-038-PLS |
| Light Source Type | Tungsten-Halogen (Standard Configuration) |
| Spectral Range | 380–1000 nm (Typical) |
| Luminance Range | 0.1–10,000 cd/m² (Adjustable via Precision Attenuation) |
| Uniformity | ≤ ±0.5% over Central 80% Area |
| Stability | ≤ ±0.2% over 30 min (Thermally Stabilized) |
| Portability | Integrated Battery Option (Optional), < 8 kg |
| Compliance | NIST-Traceable Calibration Certificate Included |
| Brand | Labsphere |
|---|---|
| Model | QES |
| Origin | USA |
| Type | Integrating Sphere-Based Monochromatic Light Source for Quantum Efficiency Testing |
| Measurement Mode | DC |
| Calibration Traceability | NIST-Traceable Spectral Irradiance and Radiance |
| Software Interface | SDK Available for Custom Test Sequence Development |
| Compliance Context | Designed to support ISO 15739, ISO 17850, and ASTM E2724-compliant QE characterization workflows |
| Key Applications | CMOS/CCD Image Sensor QE Mapping, Spectral Responsivity Validation, Pixel-Level Linearity Assessment, Module-Level Uniformity Analysis |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | QES-1000 |
| Price Range | USD 14,000 – 28,000 |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | RSA-FO-150 Fiber-Optic Single-Beam Integrating Sphere |
| Wavelength Range | 250 nm to 2500 nm |
| Brand | Labsphere |
|---|---|
| Model | RSA-FO-150-800-S |
| Wavelength Range | 360–1000 nm |
| Configuration | Dual-beam reflectance & transmittance measurement system with fiber-optic illumination and spectrometer integration |
| Integral Sphere Type | Dual-beam reflectance & transmittance sphere (150 mm diameter, barium sulfate coating, FO port configuration) |
| Compliance | ASTM E275, ASTM E903, ISO 9050, ISO 13468, ISO 14782, CIE S 014 |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RSA-FO-TW-76 |
| Pricing | Available Upon Request |