NIUMAG
Filter
Showing 271–300 of 317 results
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | QMR06-090H-PRO-5 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual Mode (Live Small Animals & Excised Tissues) |
| Magnetic Field Strength | 0.15 ± 0.015 T |
| Magnet Uniformity | ≤300 ppm |
| Sample Weight Range | 10–800 g (live rodents), 0.1–6 g (excised tissues) |
| Measurement Time | <80 s per acquisition |
| Magnet Type | Permanent Magnet |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | QMR06-090H-PRO-1 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual Mode |
| Magnetic Field Strength | 0.15 ± 0.015 T |
| Magnet Uniformity | ≤300 ppm |
| Sample Weight Range | 0.1–6 g (ex vivo tissue) |
| Magnet Type | Permanent Magnet |
| Analysis Time | <80 s per measurement |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Sample Types | Live rats, mice, rabbits |
| Measurement Time | ≤ 60 s per scan |
| Measured Parameters | Fat mass, lean tissue mass, free water content |
| Software | Integrated proprietary NMR quantification platform with GLP-compliant audit trail |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments |
| Hardware Architecture | Benchtop low-field NMR system (0.06–0.09 T) |
| Sample Handling | Non-invasive, non-destructive, no anesthesia or euthanasia required |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR06-090H |
| Instrument Type | Research-Grade Small Rodent Analyzer (Mouse/Rat) |
| Magnet Type | Permanent Magnet |
| Measurement Time | < 60 s per animal |
| Sample Requirement | Live, conscious, unrestrained |
| Measured Parameters | Fat Mass, Lean Body Mass, Free Water Content |
| Species Compatibility | Mus musculus, Rattus norvegicus, Oryctolagus cuniculus |
| Regulatory Context | Designed for GLP-compliant preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | QMR06-090H-PRO |
| Instrument Type | Research-Grade Small Rodent Analyzer |
| Sample Capacity | 800 g |
| Magnet Type | Permanent Magnet |
| Measurement Principle | Low-Field Nuclear Magnetic Resonance (LF-NMR) |
| Species Compatibility | Live Rats, Mice, and Rabbits |
| Measurement Time | ≤ 60 s per sample |
| Measured Parameters | Fat Mass, Lean Body Mass, Free Water Content |
| Sample Preparation | Non-invasive, No Anesthesia or Euthanasia Required |
| Software | Integrated LF-NMR Acquisition & Quantification Suite with GLP-Compliant Audit Trail |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | QMR06-090H-PRO-4 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase (Live Small Animals) |
| Magnet System | Permanent Magnet |
| Dedicated Probe | Mouse Body-Composition Optimized RF Coil |
| Software | NIUMAG Proprietary Mouse Body Composition Analysis Suite |
| Regulatory Compliance | Designed for GLP-Compliant Preclinical Research Environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR1 |
| Instrument Type | Research-Grade Small Animal (Mouse) Body Composition Analyzer |
| Measurement Principle | Low-Field Nuclear Magnetic Resonance (LF-NMR) Relaxometry |
| Sample State | Conscious, Non-Invasive, Anesthesia-Free |
| Typical Scan Time | 60–180 s per mouse |
| Output Parameters | Fat Mass (g), Lean Mass (g), Total Water Mass (g), %Fat, %Lean, %Water |
| Magnet System | Permanent Magnet (0.3–0.5 T typical range) |
| RF Probe | Dedicated Quadrature Mouse-Sized RF Coil |
| Software | NIUMAG Small Animal Body Composition Analysis Suite (v4.x+) |
| Regulatory Compliance | Designed for GLP-aligned workflows |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR12-060H-I |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (NMR) Analyzer |
| Spatial Resolution | 0.1 mm |
| Field of View (FOV) | 100 mm × 100 mm |
| Magnet Type | Permanent Magnet |
| Probe | Dedicated Body Composition RF Coil |
| Measurement Mode | Non-invasive, Anesthesia-Free, In Vivo |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Full-Diameter Core Analyzer-1 |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (LF-NMR) Spectrometer |
| Sample Type | Solid-Liquid Dual-Phase (Intact Shale Cores under In-Situ Pressure) |
| Operating Frequency | 6.2 MHz |
| Minimum Echo Time (TE) | 0.1 ms |
| Longitudinal Spatial Resolution | 1 cm |
| Maximum Core Length | 3.4 cm |
| Maximum Core Diameter | 115 mm |
| Relaxometry Modes | T₁, T₂, and T₁–T₂ Two-Dimensional Correlation Spectroscopy |
| Brand | NIUMAG |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SMARtracer™ |
| Instrument Type | Low-Field NMR Relaxometer |
| Sample Compatibility | Solid-Liquid Dual-Phase |
| Operating Nuclei | ¹H, ¹⁹F |
| Frequency Range | 10 mHz – 10 kHz |
| Temperature Control Range | −140 °C to +140 °C (0.1 °C resolution) |
| Relaxation Time Range | Sub-millisecond to several seconds |
| Cryogen-Free Operation | Yes |
| Automation Level | Fully Automated NMRD Profile Acquisition |
| Brand | NIUMAG |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported Low-Field NMR Analyzer |
| Model | SPINMASTER FFC2000 1T C/DC |
| NMR Frequency Range (¹H) | 0.1 kHz – 42.6 MHz |
| Temperature Control Range | −140 °C to +140 °C (0.1 °C resolution) |
| Sample Compatibility | Solid–Liquid Hybrid, Colloids, Liquid Crystals, Porous Media, Polymers, Biological Tissues |
| Multinuclear Capability | ¹H, ²H, ¹³C, ¹⁹F, ⁷Li |
| Relaxation Time Range | Sub-millisecond to several seconds (T₁ and T₂) |
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VacuumSaturator |
| Vacuum Chamber Diameter | 200 mm |
| Maximum Dry Evacuation Time | 960 min |
| Maximum Wet Evacuation Time | 240 min |
| Ultimate Vacuum Pressure | ≤ −0.095 MPa |
| Dimensions (L×W×H) | 800 mm × 600 mm × 1200 mm |
| Net Weight | 30 kg |
| Vacuum Pump Power | 370 W |
| Pump Ultimate Pressure | ≤ 5 Pa |
| Control Mode | Digital Timer with Adjustable Setpoints |
| Safety Features | Overpressure Relief Valve, Sealed Chamber Interlock, Leak-Test Function |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | VTMR |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Ambient to 130 °C |
| Optional Cryo/High-Temp Module | −100 °C to 200 °C |
| Measurement Time | ≤2 min per sample |
| Core Technology | Low-Field NMR (T₁/T₂ Relaxometry + MRI) |
| Key Capabilities | Non-destructive resin quantification, crosslink density mapping, phase distribution imaging, in-situ curing kinetics monitoring |
| Sample States Supported | Solid composites, gels, powders, films, pre-pregs |
| Compliance Framework | Designed for GLP-compliant workflows |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VTMR |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Ambient to 130 °C |
| Optional Cryo/High-Temp Module | −100 °C to 200 °C |
| Measurement Time | ≤2 min per sample |
| Core Technology | Low-Field NMR (T₁/T₂ Relaxometry + MRI) |
| Key Innovation | FLAT Pulse Sequence for Short-T₂/Weak-Signal Acquisition |
| Sample Types | Solutions, Gels, Solids, Powders, Fiber Preforms |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | VTMR |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (LF-NMR) Analyzer |
| Sample Type | Solid-Liquid Hybrid |
| Operating Mode | Pulsed Fourier Transform (PFT) |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Ambient to 130 °C |
| Optional Cryo/High-Temp Module | −100 °C to 200 °C |
| Typical Measurement Time | ≤2 min per sample |
| Core Techniques | T₁/T₂ Relaxometry, NMR Imaging (MRI), FLAT (Fast Low-Amplitude Transient) Acquisition for Short-T₂ Signals |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | VTMR |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Compatible |
| Operating Mode | Pulsed Fourier Transform |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Effective Sample Detection Volume | Ø8.5 mm × H20 mm |
| Temperature Control Range | Ambient to 130 °C (Standard) / Ambient to 180 °C (Optional) |
| Measurement Time | ≤2 min per sample |
| Imaging Capability | Optional |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | VTMR Series |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase |
| Operating Mode | Pulsed Fourier Transform |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VTMR-niumag |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Room Temperature to 130 °C |
| Optional Cryo/High-Temp Module | −100 °C to 200 °C |
| Imaging Capability | Optional |
| Measurement Modes | T₁ & T₂ Relaxometry, NMR Imaging (MRI), Quantitative Analysis |
| Typical Acquisition Time | ≤2 min per sample |
| Sample Forms | Solutions, Gels, Solids, Powders, Particulates |
| Core Technology | FLAT (Fast Low-Amplitude Transient) Pulse Sequence for Short-T₂/Weak-Signal Detection |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | VTMR |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Room Temperature to 130 °C |
| Optional Cryo/High-Temp Module | –100 °C to 200 °C |
| Imaging Capability | Optional |
| Core Technology | FLAT (Fast Low-Amplitude Transient) Acquisition for Short-T₁/T₂ & Weak-Signal Detection |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | VTMR |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Ambient to 130 °C |
| Optional Cryo/High-Temp Module | –100 °C to 200 °C |
| Imaging Capability | Optional |
| Core Technology | FLAT (Fast Low-Amplitude Transient) Acquisition for Short-T₂/Weak-Signal Detection |
| Primary Measurement Modes | T₁ & T₂ Relaxometry, Diffusion-Weighted Analysis, MR Imaging (optional) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | VTMR |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Ambient to 130 °C |
| Optional Cryo/High-Temp Module | −100 °C to 200 °C |
| Imaging Capability | Optional |
| Core Technology | FLAT (Fast Low-Amplitude Transient) Pulse Sequence for Short-T₂/Weak-Signal Acquisition |
| Measurement Modes | T₁ & T₂ Relaxometry, NMR Imaging (optional), Quantitative Crosslink Density Mapping |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | VTMR- |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Compatible |
| Operating Mode | Pulsed Fourier Transform |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Effective Sample Detection Volume | Ø8.5 mm × H20 mm |
| Temperature Control Range | RT to 130 °C (Standard) / RT to 180 °C (Optional) |
| Imaging Capability | Optional |
| Measurement Time | ≤2 min per sample |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Room Temperature to 130 °C |
| Optional Cryo/High-Temp Module | −100 °C to 200 °C |
| Relaxometry Capabilities | T₁ and T₂ Relaxation Time Measurement |
| Advanced Signal Acquisition | FLAT (Fast Low-Amplitude Transient) Technology for Short-T₁/T₂ and Weak-Signal Samples |
| Sample Forms Supported | Solutions, Gels, Solids, Powders, and Particulates |
| Compliance Framework | Designed for GLP/GMP-aligned workflows |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | VTMR-MR |
| Pricing | Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Domestic/Imported | Domestic |
| Model | VTMR-MRI |
| Instrument Type | NMR Imaging System |
| Sample Compatibility | Solid-Liquid Dual-State |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Magnet Type | Permanent Magnet |
| Standard Temperature Range | Room Temperature to 130 °C |
| Optional Cryo/High-Temp Module | −100 °C to 200 °C |
| Imaging Capability | Optional |
| Core Technology | FLAT (Fast Low-Amplitude Transient) Acquisition for Short-T₂/Weak-Signal Samples |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | VTMR-nmr |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Magnet Type | Permanent Magnet |
| Standard Temperature Range | Ambient to 130 °C |
| Optional Cryo/High-Temp Module | –100 °C to 200 °C |
| MRI Capability | Optional |
| Core Technology | FLAT (Fast Low-Amplitude Transient) Pulse Sequence for Short-T₂ Signal Acquisition |
| Primary Measurement Modes | T₁ & T₂ Relaxometry, Diffusion-Weighted Analysis, Spatially Resolved Imaging (with optional gradient set) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VTMR-r |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Sample Detection Volume | Ø8.5 mm × H20 mm |
| Standard Temperature Range | Ambient to 130 °C |
| Optional High-Temp Module | Ambient to 200 °C |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | VTMR-Tg |
| Instrument Type | Low-Field NMR Spectrometer |
| Sample Type | Solid-Liquid Dual-Mode |
| Operating Mode | Pulsed Fourier Transform |
| Sensitivity | Signal-to-Noise Ratio (SNR) Optimized |
| Resolution | Sub-millimeter Spatial Resolution (Imaging Mode, Optional) |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 0.5 ± 0.05 T |
| Effective Sample Volume | Ø8.5 mm × H20 mm |
| Temperature Control Range | Ambient to 130 °C (Standard) |
| Imaging Capability | Optional MRI-Enabled Configuration |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Model | VTMR20-010V |
| Sample Compatibility | Solid-Liquid Hybrid Systems |
| Operating Field Strength | < 0.5 T |
| Measurement Principle | Transverse Relaxation Time (T₂) Distribution Analysis |
| Temperature Simulation Range | Ambient to 120 °C (integrated heating module) |
| Data Acquisition Mode | CPMG pulse sequence |
| Key Output Parameters | T₂ distribution spectra, bound/free fluid ratio, peak shift quantification, area under curve (AUC) change rate |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | VTMR20-010V |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual Compatibility |
| Operating Mode | Pulsed Fourier Transform |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Effective Sample Volume | Ø8.5 mm × H20 mm |
| Temperature Control Range | Ambient to 130 °C (standard), extended options available |