| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PQ001-YL |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Suspensions |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 T ± 0.03 T |
| Magnet Homogeneity | ≤30 ppm over H-volume |
| Sample Tube Dimensions | Ø12.5 mm × H15 mm (cylindrical) |
| Measurement Time per Sample | ≤3 min |
| Wet Specific Surface Area Repeatability | RSD ≤1.0% |
| Probe Options | Multi-size RF probes available |
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| Measurement Principle | Low-Field Nuclear Magnetic Resonance (LF-NMR) |
| Sample Throughput | Single vial or syringe per measurement |
| Analysis Time | ≤ 120 s |
| Packaging Compatibility | Glass vials, plastic syringes, ampoules |
| Calibration Method | External mass-based linear calibration using reference samples in native packaging |
| Regulatory Context | Supports GLP-compliant moisture screening |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PQ001-ZF |
| Quotation | Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PQ001+ |
| Instrument Type | Low-Field NMR Relaxometer |
| Sample Compatibility | Solid-Liquid Dual-Mode |
| Pricing | Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | PQ001++ |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (NMR) Spectrometer |
| Sample Form | Solid-Liquid Hybrid (Toothpaste Paste) |
| Operating Frequency | 21.3 MHz |
| Data Acquisition Mode | Pulsed Fourier Transform (PFT-NMR) |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| Probe Coil Diameter | 25 mm |
| Detection Nucleus | ¹⁹F |
| Calibration Range | 100–2000 ppm F⁻ |
| Typical Measurement Time | < 5 min per sample |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PQ001GU |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| Probe Coil Diameter | 18 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PQ001SFC |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| Larmor Frequency | 21.3 MHz |
| Probe Coil Diameter | 10 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | QMR |
| Pricing | Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | QMR Series |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | QMR Series |
| Instrument Type | Research-Grade Small Animal (Mouse/Rat) Analyzer |
| Core Magnet | Permanent Magnet |
| Measurement Principle | Quantitative Low-Field NMR Relaxometry |
| Software | NIUMAG Proprietary Mouse Body Composition Analysis Suite |
| Compliance | Designed for GLP-aligned preclinical metabolic studies |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | QMR Series |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase (In Vivo Rodent Models) |
| Measurement Principle | Proton (¹H) Transverse Relaxation Time (T₂) Discrimination |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR Series |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Application | In Vivo Rodent Metabolism Quantification (Mice, Rats, Rabbits) |
| Measurement Time | 1–3 min per scan |
| Sample State | Conscious, Non-Invasive, No Anesthesia or Sacrifice Required |
| Core Output Parameters | Fat Mass, Lean Body Mass, Total Body Water (TBW) |
| Compliance Context | Designed for GLP-aligned preclinical research workflows |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Animal Compatibility | Live mice, rats, rabbits |
| Measurement Time | < 60 s per subject |
| Output Parameters | Fat Mass, Lean Body Mass, Total Body Water |
| Regulatory Compliance | Designed for GLP-compliant preclinical research environments |
| Software | Proprietary NMR quantification suite with audit trail capability |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Model | QMR-06 |
| Sample Type | Live small animals (mice, rats, rabbits) — solid/liquid non-invasive measurement |
| Magnet Type | Permanent magnet |
| Measurement Time | ≤ 60 s per sample |
| Application | Quantitative in vivo fat mass, lean body mass, and free water content |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Research-Grade Small Animal (Mouse/Rat) Body Composition Analyzer |
| Sample Capacity | Live Mice and Rats |
| Primary Measurement | Fat Mass, Lean Body Mass, Free Water Content |
| Magnet Type | Permanent Magnet |
| Test Duration | ≤ 60 s per animal |
| Sample Preparation | None (Non-invasive, Non-anesthetized, Non-terminal) |
| Compliance Context | Designed for GLP-aligned preclinical metabolic phenotyping workflows |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | QMR06 Series |
| Pricing | Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Sample Type | Live Rodents (Mice, Rats, Rabbits) |
| Measurement Time | < 60 s per sample |
| Measured Parameters | Fat Mass, Lean Mass, Free Water Content |
| Software | Integrated QMR Analysis Suite with GLP-Compliant Audit Trail |
| Regulatory Compliance | Designed to support ISO/IEC 17025-aligned workflows and FDA 21 CFR Part 11–ready data integrity architecture |
| Application Scope | Preclinical metabolic phenotyping, longitudinal obesity/diabetes studies, pharmacological intervention monitoring |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | QMR06-060H-PRO |
| Instrument Type | Research-Grade Small Animal (Mouse/Rat) Analyzer |
| Sample Capacity | Single mouse (up to 50 g) or rat (up to 300 g) |
| Core Functions | In vivo quantification of fat mass, lean body mass, and total body water |
| Magnet System | Permanent magnet (low-field, ~0.06 T) |
| Measurement Time | ≤ 60 s per scan |
| Sample Preparation | Non-invasive, no anesthesia, no euthanasia required |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | QMR06-060H-PRO |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Sample Types | Live rats, mice, rabbits |
| Measurement Time | ≤ 60 seconds per animal |
| Measured Parameters | Fat mass, lean tissue mass, free water content |
| Sample Preparation | None required (non-invasive, conscious or lightly restrained animals) |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR06-090H |
| Instrument Type | In Vivo Small Animal (Rat/Mouse) Body Composition Analyzer |
| Sample Capacity | ≤800 g |
| Core Functions | Fat Mass, Lean Body Mass, Total Body Water Quantification |
| Construction | Benchtop Permanent-Magnet NMR System |
| Magnet Type | Permanent Magnet |
| Measurement Time | <60 s per scan |
| Sample Requirement | Conscious, Unanesthetized, Non-invasive |
| Regulatory Compliance | Designed for GLP-aligned preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR06-090H |
| Instrument Type | Research-Grade Small Animal (Mouse/Rat) Body Composition Analyzer |
| Sample Capacity | 60 mm Bore — 10–100 g |
| Core Functions | In vivo quantification of total fat mass, lean tissue mass, and free water content |
| Magnet System | Permanent Magnet (Low-Field, ~0.3–0.5 T typical for QMR platforms) |
| Measurement Time | ≤ 60 s per subject |
| Sample Preparation | None — conscious or lightly restrained live animals only |
| Regulatory Context | Designed for GLP-compliant preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Spectrometer |
| Model | QMR06-090H-1 |
| Sample Compatibility | Solid-Liquid Dual-Phase (Live Small Animals) |
| Magnet System | Permanent Magnet |
| Probe | Dedicated Mouse/Rat Body Composition RF Coil |
| Measurement Principle | T₂ Relaxation Time Discrimination of Fat, Lean Tissue, and Free Water |
| Software | NIUMAG Proprietary Rodent Body Composition Analysis Suite |
| Regulatory Context | Designed for GLP-Compliant Preclinical Research Environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Model | QMR06-090H-2 |
| Sample Compatibility | Solid-Liquid Dual-Phase (Live Small Animals) |
| Measurement Principle | T₂ Relaxometry-Based Quantitative Fat/Muscle/Water Composition Analysis |
| Typical Scan Time | 60–180 s per animal |
| Operating Field Strength | ~0.06–0.09 T (6–9 MHz ¹H Larmor Frequency) |
| Animal Handling | Non-invasive, conscious-state measurement |
| Regulatory Context | Designed for preclinical GLP-compliant metabolic phenotyping |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Model | QMR06-090H-3 |
| Sample Compatibility | Solid-Liquid Dual-Phase (Live Small Animals) |
| Magnetic Field Strength | ~0.06–0.09 T (Typical for Benchtop LF-NMR) |
| Measurement Time per Sample | 60–180 s |
| Output Parameters | Fat Mass, Lean Body Mass, Total Body Water (TBW), Fat Fraction (%), Lean/Fat Ratio |
| Compliance | Designed for GLP-aligned preclinical research workflows |
| Brand | NIUMAG |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | QMR06-090H-PRO |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode (In Vivo Conscious Small Animals & Excised Tissues) |
| Magnetic Field Strength | 0.15 ± 0.015 T |
| Magnet Uniformity | ≤300 ppm |
| Animal Weight Range | 10–100 g (in vivo) |
| Excised Tissue Range | 0.1–6 g |
| Measurement Time | <80 s per acquisition |
| Magnet Type | Permanent Magnet |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Instrument Manufacturer (not distributor) |
| Product Category | Domestic |
| Model | QMR06-090H-PRO |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode (Live Small Animals & Excised Tissues) |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 0.15 ± 0.015 T |
| Magnetic Homogeneity | ≤300 ppm over DSV |
| Sample Weight Range | 0.1–6 g (excised tissues) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Magnetic Field Strength | 0.15 ± 0.015 T |
| Magnet Uniformity | ≤300 ppm |
| Sample Capacity | 0.1–6 g (ex vivo tissue) or 10–800 g (live small rodents) |
| Measurement Mode | Solid-Liquid Dual-State NMR Relaxometry |
| Acquisition Time | ≤80 s per quantitative assay |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | QMR06-090H-PRO-2 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual Mode (Live Small Animals & Excised Tissues) |
| Magnetic Field Strength | 0.15 ± 0.015 T |
| Magnet Uniformity | ≤300 ppm |
| Sample Weight Range | 10–800 g (live rodents), 0.1–6 g (excised tissues) |
| Analysis Time | <80 s per measurement |