Shenchanghong
Filter
Showing 151–173 of 173 results
| Brand | Shenchanghong |
|---|---|
| Model | TCLR-50A |
| Measurement Range | 0.00–500 PCU |
| Resolution | 0.01 PCU |
| Accuracy | ±3% of full scale |
| Repeatability | ≤3% |
| Optical Drift | <0.002 A within 20 min |
| Dimensions | 340 × 250 × 130 mm |
| Weight | 4 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Power Supply | AC (220 ± 22) V, (50 ± 0.5) Hz |
| Light Source | High-brightness, long-life (100,000 h) imported LED |
| Display | Large LCD with Chinese interface |
| Data Storage | 10 calibration curves + 500 measurement records |
| Connectivity | USB port for data export |
| Optional | Thermal printer support |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TCNP-301D |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Rapid Digestion–Spectrophotometric Method (Colorimetric) |
| Wavelength Range | 420 nm, 610 nm, 700 nm (pre-configured for COD, NH₃-N, and TP) |
| Measurement Ranges | COD: 5–2000 mg/L (extendable to 20,000 mg/L) |
| Ammonia-N | 0.02–25 mg/L |
| Total Phosphorus | 0.00–20 mg/L |
| Accuracy | COD: ≤ ±5% FS |
| Ammonia-N | ≤ ±3% FS |
| Total Phosphorus | ≤ ±5% FS |
| Repeatability | ≤ 3% RSD |
| Detection Limit | 0.2 mg/L (COD) |
| Analysis Time | COD: 15 min |
| Total Phosphorus | 30 min |
| Batch Capacity | 16 samples (optional 20/25/36-position digestion blocks) |
| Digestion Temperature | 120–165 °C (adjustable) |
| Temperature Control Accuracy | ≤ ±1.0 °C |
| Optical Stability | ≤ 0.002 A / 20 min |
| Data Storage | 100,000 records (including parameter name, concentration, unit, timestamp, operator ID) |
| Display | 7-inch color TFT touchscreen with bilingual (Chinese/English) UI |
| Connectivity | USB port for data export and PC software integration |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Analyzer |
| Model | TCNPN-401D |
| Detection Principle | Rapid Digestion Spectrophotometry (Hach-style closed-tube digestion followed by absorbance measurement) |
| Wavelength Range | 420 nm (COD), 610 nm (Ammonia-N), 700 nm (Total Phosphorus), 220/275 nm (Total Nitrogen via UV-VIS dual-wavelength correction) |
| Measurement Ranges | COD: 5–2000 mg/L (extendable to 20,000 mg/L) |
| Ammonia-N | 0.02–25 mg/L |
| Total Phosphorus | 0.00–10 mg/L |
| Total Nitrogen | 0.05–100 mg/L |
| Accuracy | ≤ ±5% (COD, TP, TN), ≤ ±3% (NH₃-N) |
| Repeatability | ≤ 3% RSD |
| Detection Limit | 0.1 mg/L (COD), 0.01 mg/L (NH₃-N), 0.005 mg/L (TP), 0.02 mg/L (TN) |
| Digestion Time | 15 min (COD), 30 min (TP/TN), variable (NH₃-N) |
| Batch Capacity | 16 samples (expandable to 20/25/36 with optional DIS-20B/DIS-25B/DIS-36B digester) |
| Optical Stability | ≤ 0.002 A/20 min |
| Temperature Control Range | Ambient to 200 °C |
| Temperature Accuracy | ≤ ±1.0 °C |
| Chloride Interference Tolerance | ≤ 2000 mg/L (COD module with masking agent) |
| Data Storage | 100,000 records (including timestamp, operator ID, parameter, concentration, unit, calibration history) |
| Interface | USB 2.0, thermal printer port |
| Display | 7-inch color capacitive touchscreen, bilingual (English/Chinese) UI |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TMULP-3000 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Rapid Digestion (for COD) + Spectrophotometry (UV-Vis) + Electrochemical Sensing (pH, EC, DO, Temp) |
| Optical Channels | 4 / 8 / 12 / 16 (customizable 1–16) |
| Available Wavelengths | 340, 420, 440, 470, 520, 540, 560, 610, 630, 660, 680, 700 nm |
| Wavelength Accuracy | ±1 nm (center wavelength) |
| Absorbance Range | −2.000 to +2.000 A |
| Absorbance Linearity | ±0.002 A (0–1 A) |
| Absorbance Precision | ±0.005 A at 1 A |
| Repeatability | ≤±2% (spectrophotometric), ≤±3% (electrochemical) |
| Detection Limit (COD) | 0.1 mg/L |
| Measurement Time (per batch) | 15 min |
| Batch Capacity | 16 samples |
| Photometric Stability | ≤0.002 A / 20 min |
| Light Intensity Adjustment | 16-level programmable |
| Temperature Range (Operation) | 5–40 °C |
| Relative Humidity (Operation) | ≤90% RH |
| Storage Environment | −40 to +60 °C, ≤90% RH |
| Display | Color TFT Touchscreen (bilingual: English/Chinese) |
| Power Supply | AC 220 V (165–240 V), 30 W |
| Dimensions | 400 × 300 × 140 mm |
| Weight | 2.6 kg |
| Host Power Consumption | <10 W |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TN-2E |
| Measurement Method | UV Spectrophotometry (with optional chromotropic acid method support) |
| Range | 0.05–100 mg/L |
| Accuracy | ≤ ±5% FS |
| Detection Limit | ≤ 0.05 mg/L (as N) |
| Resolution | 0.01 mg/L |
| Display | 7-inch color TFT touchscreen with bilingual (English/Chinese) UI |
| Optical System | Cold light source, narrow-band interference optics, 16-step adjustable intensity |
| Repeatability | ≤ ±3% RSD |
| Optical Stability | ≤ 0.002 A/20 min |
| Digestion Temperature | 125 °C (adjustable up to 200 °C) |
| Digestion Time | 30 min (programmable) |
| Temperature Control Accuracy | ≤ ±1.0 °C |
| Sample Throughput | 16 samples per batch (optional 20/25/36-position digestion blocks) |
| Data Storage | 100,000 records (including timestamp, operator ID, concentration, unit, calibration data) |
| Calibration Capacity | 250 factory curves + 3,500 user-defined curves |
| Connectivity | USB port for PC data transfer |
| Safety Features | Dual thermal protection (auto-shutdown at ≥200 °C), digestion timer with audible alert, insulated digestion hood |
| Dimensions (Analyzer) | 400 × 300 × 140 mm |
| Weight (Analyzer) | 2.6 kg |
| Dimensions (Digester) | 260 × 355 × 135 mm |
| Weight (Digester) | 5.5 kg |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | TN-3A |
| Price | ¥12,400 |
| Measured Parameter | Total Nitrogen |
| Instrument Type | Laboratory |
| Measurement Principle | UV-Vis Spectrophotometry (Lambert-Beer Law) |
| Measurement Range | 0.05–100 mg/L (dual-range: 0.05–10 mg/L and 10–100 mg/L) |
| Accuracy | ±5% of reading (±0.5% F.S.) |
| Detection Limit | ≤±3% repeatability |
| Resolution | 0.01 mg/L |
| Digestion Time | 30 min |
| Digestion Temperature | 125 °C (adjustable from ambient to 200 °C) |
| Optical Stability | ≤0.002 A/20 min |
| Sample Throughput | 16 samples per batch (optional 20/25/36) |
| Display | LCD with Chinese/English interface |
| Data Interface | USB |
| Storage Capacity | 20 built-in calibration curves |
| Power Backup | Battery-supported data retention on power loss |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TN-3C |
| Price | ¥12,800 |
| Measured Parameter | Total Nitrogen |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Sealed High-Temperature Catalytic Digestion + Colorimetric Detection (Alkaline Potassium Persulfate Oxidation) |
| Measurement Range | 0.05–100 mg/L as N |
| Accuracy | ±5% of full scale (F.S.) |
| Detection Limit | Not specified (method-dependent |
| Temperature Control Range | Ambient to 200 °C |
| Digestion Temperature | 125 °C (preset) |
| Digestion Time | 30 min (adjustable from 1–9999 min) |
| Temperature Control Precision | ≤±1.0 °C |
| Repeatability | ≤±3% RSD |
| Optical Stability | ≤0.002 A / 20 min |
| Display | 5-inch color TFT touch screen with bilingual (Chinese/English) UI |
| Data Storage | 100 calibration curves, 1000 measurement records |
| Connectivity | USB interface for data export |
| Dimensions (Analyzer) | 400 × 310 × 158 mm |
| Dimensions (Digestion Unit) | 260 × 355 × 135 mm (excl. shield) |
| Weight (Analyzer) | 5.0 kg |
| Weight (Digestion Unit) | 5.5 kg |
| Batch Capacity | 16 samples (optional 20/25/36-position blocks available) |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Type | Domestic |
| Model | TN-3C / TN-3D |
| Measurement Parameter | Total Nitrogen (TN) |
| Instrument Category | Laboratory Analyzer |
| Measurement Principle | Alkaline Potassium Persulfate Digestion + UV Spectrophotometry |
| Measurement Range | 0.05–100 mg/L |
| Accuracy | ±5% of reading |
| Repeatability | ≤3% RSD |
| Detection Limit | Not specified (method-dependent |
| Temperature Control Precision | ±0.5 °C |
| Temperature Range | Ambient to 200 °C (digestion setpoint: 125 °C) |
| Digestion Time | 30 min (programmable: 1–9999 min) |
| Optical Stability | Drift < 0.002 A in 20 min |
| Sample Throughput | 16 samples per batch |
| Display | 7-inch color TFT touchscreen with bilingual Chinese/English UI |
| Data Storage | TN-3C — 300 calibration curves + 1,000 measurement records |
| Connectivity | USB port for PC export and firmware update |
| Power Supply | AC 220 V ±10%, 50 Hz, <500 W |
| Dimensions (Analyzer) | 400 × 310 × 158 mm |
| (Digestor DIS-16B) | 355 × 260 × 135 mm |
| Weight (Analyzer) | 4 kg |
| (Digestor) | 5.5 kg |
| Operating Environment | 5–40 °C, RH ≤85%, non-condensing, low EMI/vibration |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TN-3E |
| Price | ¥11,800 |
| Measured Parameter | Total Nitrogen |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Alkaline Potassium Persulfate UV Digestion & Spectrophotometric Detection (220 nm & 275 nm) |
| Measurement Range | 0.05–100 mg/L |
| Accuracy | ≤ ±5% of Full Scale |
| Detection Limit | 0.01 mg/L |
| Resolution | Color Touchscreen Display with English/Chinese Interface |
| Digestion Temperature | 125 °C |
| Digestion Time | 30 min |
| Temperature Control Range | Ambient to 200 °C (adjustable) |
| Optical Stability | ≤ 0.002 A / 20 min |
| Absorbance Error | ≤ ±5% F.S. |
| Repeatability | ≤ 3% RSD |
| Sample Throughput | 16 samples per batch (optional 20/25/36-position blocks) |
| Weight | Analyzer: 2.6 kg |
| Digestion Unit | 5.5 kg |
| Power Consumption | < 500 W |
| Dimensions (Analyzer) | 400 × 300 × 140 mm |
| (Digestor, w/o shield) | 260 × 355 × 135 mm |
| Operating Environment | 5–40 °C, RH ≤ 85%, AC (220 ± 22) V, (50 ± 0.5) Hz |
| Data Storage Capacity | 100,000 records (including parameter name, concentration, unit, timestamp, operator ID) |
| Calibration Curves | Up to 3,500 user-defined curves + 250 factory preloaded |
| Connectivity | USB port for PC data export |
| Output | Built-in thermal printer support |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | TNH-6N |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Nessler Colorimetry |
| Measurement Range | 0.02–25 mg/L (NH₃–N) |
| Accuracy | ≤ ±3% FS |
| Detection Limit | 0.02 mg/L |
| Measurement Time | 10 minutes per batch |
| Sample Throughput | 16 samples per run |
| Optical Stability | ≤ 0.002 A / 20 min |
| Display | 7-inch Color Touchscreen (Chinese & English UI) |
| Data Storage | 3,500 calibration curves + 100,000 measurement records (non-volatile memory) |
| Interface | USB port for PC connectivity and data export |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | 5–40 °C, RH ≤85%, no strong vibration or electromagnetic interference |
| Dimensions | 340 × 250 × 130 mm |
| Weight | 2.6 kg |
| Power Consumption | 30 W |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TO3-260 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Operating Temperature | 5–40 °C |
| Reagent Storage/Use Temperature | 5–40 °C |
| Repeatability | ≤3% |
| Sample Throughput | 1 sample per batch |
| Analysis Time | 20 min |
| Measurement Range | 0.01–2.5 mg/L O₃ |
| Accuracy (Abs. Error) | ≤±5% |
| Optical Drift | <0.002 A over 20 min |
| Dimensions (W×D×H) | 266 × 200 × 130 mm |
| Weight | 1 kg |
| Power Supply | AC 220 ± 22 V, 50 ± 0.5 Hz |
| Relative Humidity Limit | ≤85% RH (non-condensing) |
| Brand | Shenchanghong |
|---|---|
| Model | TO3-260 |
| Measurement Range | 0.01–2.5 mg/L |
| Accuracy | ≤±5% FS |
| Repeatability | ≤3% RSD |
| Optical Drift | <0.002 A in 20 min |
| Dimensions (H×W×D) | 266 mm × 200 mm × 130 mm |
| Weight | 1 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Light Source | High-brightness, long-life (100,000 h) monochromatic cold LED |
| Display | Backlit LCD with Chinese menu interface |
| Data Storage | 10 preloaded calibration curves + 500 measurement records (non-volatile memory) |
| Connectivity | USB port for data export |
| Printer | Integrated thermal printer |
| Compliance | Designed for routine water quality compliance testing per national and municipal drinking water and wastewater monitoring protocols |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP-1A |
| Price | ¥9,800 |
| Measured Parameter | Total Phosphorus |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Sealed High-Temperature Digestion Followed by Colorimetric Detection (Molybdenum Blue Method) |
| Measurement Range | 0.02–10 mg/L as P |
| Accuracy | ≤ ±5% of Full Scale or ±0.2 mg/L (whichever is greater) |
| Repeatability | ≤ 3% RSD |
| Detection Limit | 0.02 mg/L |
| Digestion Temperature | 120 °C ± 1.0 °C |
| Digestion Time | 30 min |
| Optical Stability | ≤ 0.002 A / 20 min |
| Resolution | 0.001 mg/L (display), 0.002 A (absorbance) |
| Batch Capacity | 16 samples (DIS-16B digester |
| Dimensions (Analyzer) | 266 × 200 × 130 mm |
| Dimensions (Digester) | 355 × 260 × 135 mm |
| Power Consumption | 400 W |
| Display | 3.5-inch color TFT touchscreen (320 × 240 pixels), bilingual Chinese/English UI |
| Housing Material | Molded ABS with corrosion-resistant finish |
| Microcontroller | 16-bit low-power MCU |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP-2C / TP-2D |
| Measurement Parameter | Total Phosphorus (TP) |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Sealed High-Temperature Digestion + Colorimetric Detection (Molybdenum Blue Method) |
| Measurement Range | TP-2C: 0.02–10 mg/L (dilutable beyond range) |
| Accuracy | ≤ ±5% of Full Scale |
| Repeatability | ≤ ±3% |
| Detection Limit | 0.02 mg/L |
| Resolution | 0.001 mg/L |
| Optical Stability | ≤ 0.002 A / 20 min |
| Digestion Temperature Control | PID-controlled, 25–200 °C (standard TP digestion at 120 °C) |
| Digestion Time | 30 min (user-adjustable) |
| Batch Capacity | 16 samples (optional 20/25/36-position blocks) |
| Display | 5-inch color TFT touchscreen with bilingual (Chinese/English) UI |
| Data Storage | TP-2C: 300 calibration curves + 1,000 measurement records |
| TP-2D | 3,500 curves + 100,000 records |
| Connectivity | USB port for data export and printer interface |
| Security | Password-protected system access and configuration |
| Calibration | Built-in auto-zero and reference calibration routines |
| Physical Dimensions (Analyzer) | 400 × 310 × 158 mm |
| (Digestor) | 355 × 260 × 135 mm (excl. shield) |
| Weight | Analyzer: 5.0 kg |
| Digestor | 5.5 kg |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP-2E |
| Measurement Parameter | Total Phosphorus |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | UV-Vis Spectrophotometry (Molybdenum Blue Method) |
| Measurement Range | 0.00–10.00 mg/L as P |
| Accuracy | ≤ ±5% of Full Scale |
| Detection Limit | 0.02 mg/L |
| Resolution | 0.01 mg/L |
| Repeatability | ≤ 3% RSD |
| Optical Stability | ≤ 0.002 A/20 min |
| Digestion Temperature | 120 °C |
| Digestion Time | 30 min |
| Batch Capacity | 16 samples (optional 20/25/36-position digestion blocks) |
| Power Consumption | < 500 W |
| Net Weight | Analyzer: 2.6 kg |
| Digestion Unit | 5.5 kg |
| Dimensions (Analyzer) | 400 × 300 × 140 mm |
| (Digestor) | 260 × 355 × 135 mm |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Rapid Catalytic Digestion Followed by Spectrophotometric Detection (Dichromate Method per HJ 399–2017) |
| Measurement Range | 5–2000 mg/L COD (dilutable for higher concentrations) |
| Accuracy | ≤ ±5 % of Full Scale |
| Repeatability | ±3 % RSD |
| Detection Limit | 0.2 mg/L COD |
| Digestion Time | 15 min at 165 °C |
| Batch Capacity | 16 samples (optional configurations: 20/25/36 positions) |
| Chloride Interference Tolerance | ≤ 2000 mg/L Cl⁻ |
| Optical Stability | ≤ 0.002 A / 20 min |
| Temperature Control Range | Ambient to 200 °C (±0.5 °C accuracy) |
| Display | 7-inch Color TFT Touchscreen with Dual-Language UI (English & Chinese) |
| Data Storage | Up to 100,000 measurement records with timestamp, operator ID, calibration history, and curve metadata |
| Connectivity | USB 2.0 port for data export and PC software integration |
| Power Supply | AC 220 V ±10 %, 50 Hz |
| Dimensions (Analyzer) | 400 × 300 × 140 mm |
| (Digestion Unit) | 260 × 355 × 135 mm (excl. shield) |
| Net Weight (Analyzer) | 2.6 kg |
| (Digestion Unit) | 5.5 kg |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Analyzer |
| Model | TQCOD-3N |
| Measurement Principle | Sealed Catalytic Digestion + Spectrophotometric Detection at 610 ± 20 nm |
| Measurement Range | 5–2000 mg/L (extendable to 20,000 mg/L) |
| Accuracy | ≤ ±5% |
| Repeatability | ≤ ±3% |
| Detection Limit | 0.1 mg/L |
| Digestion Temperature | 165 °C |
| Digestion Time | 15 min |
| Temperature Control Range | Ambient to 200 °C |
| Chloride Interference Tolerance | ≤ 2000 mg/L |
| Optical Stability | ≤ 0.002 A / 20 min |
| Batch Capacity | 16 samples (optional 20/25/36-tube configurations) |
| Display | Color TFT Touchscreen with English & Chinese UI |
| Data Storage | Up to 100,000 records (including timestamp, operator ID, concentration, unit, method ID) |
| Connectivity | USB interface for PC data export |
| Power Protection | Dual-stage thermal cutoff (auto-shutdown at >200 °C) |
| Calibration | Multi-point non-linear temperature compensation |
| Reporting | On-device printing & software-assisted report generation |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TQCOD-6Mn |
| Measurement Principle | Acidic Potassium Permanganate Oxidation (ISO 8467) |
| Instrument Type | Benchtop Laboratory Analyzer |
| Range | 0.00–10.00 mg/L (dilutable beyond range) |
| Repeatability | ±3% RSD |
| Accuracy | ±5% of full scale |
| LOD | 0.2 mg/L |
| Resolution | 0.01 mg/L |
| Single-Test Duration | 30 min |
| Digestion Temperature | 100 °C ±1.5 °C |
| Optical Stability | ≤0.002 A / 20 min |
| Dimensions (Analyzer) | 400 × 300 × 140 mm |
| Weight | 2.6 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | 5–40 °C, RH ≤85%, non-condensing, low vibration & EMI |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TSS-200 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Range | 0–1000 mg/L |
| Accuracy | ≤ ±3% FS |
| Repeatability | ≤ ±2% FS |
| Resolution | 0.01 mg/L |
| Dimensions | 340 × 250 × 130 mm |
| Weight | 4 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤70% RH |
| Power Supply | AC (220 ±10%) V, 50 Hz |
| Light Source | Imported high-intensity LED (100,000-hour lifetime) |
| Optical System | Narrow-band interference filter |
| Display | Backlit LCD with Chinese menu interface |
| Data Storage | 20 built-in calibration curves + 400 measurement records (non-volatile memory) |
| Connectivity | USB port for data export |
| Optional | Thermal printer support |
| Housing Material | Molded ABS with corrosion resistance |
| Microcontroller | 16-bit low-power MCU |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TURB-3C |
| Pricing | Available Upon Request |
| Measurement Range | 0–400 NTU |
| Accuracy | ≤ ±2% FS |
| Repeatability | ≤ ±2% FS |
| Minimum Resolution | 0.01 NTU |
| Drift | < 0.1 NTU/h |
| Dimensions | 400 mm × 310 mm × 158 mm |
| Weight | 5 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤70% RH |
| Power Supply | AC (220 ±10%) V, 50 Hz |
| Display | 5-inch color TFT touchscreen with bilingual (Chinese/English) UI |
| Data Interface | USB port for data export and PC connectivity |
| Calibration | Onboard self-calibration function |
| Memory Capacity | 300 calibration curves, 1,000 measurement records (non-volatile) |
| Security | Password-protected system settings and startup |
| Recovery | One-click system restore |
| Optical System | High-stability imported LED light source with narrow-band interference filter |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TURB-3C |
| Form Factor | Benchtop / Laboratory |
| Measurement Range | 0–400 NTU |
| Resolution | 0.1 NTU |
| Operating Temperature | 5–40 °C |
| Accuracy | ≤ ±1 % FS |
| Repeatability | ≤ ±2 % FS |
| Drift | < 0.1 NTU/h |
| Display | 5-inch color TFT touchscreen (bilingual UI) |
| Data Interface | USB port for data export and PC connectivity |
| Calibration | Onboard self-calibration with user-defined standard curves |
| Memory | 300 calibration curves, 1,000 measurement records (non-volatile) |
| Housing | Molded ABS with corrosion resistance |
| Power Supply | AC 220 V ±10 %, 50 Hz |
| Dimensions | 400 × 310 × 158 mm |
| Weight | 5 kg |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TURB-6A |
| Form Factor | Benchtop / Laboratory |
| Measurement Range | 0.00–400 NTU |
| Resolution | 0.01 NTU |
| Operating Temperature | 5–40 °C |
| Accuracy | ≤ ±2 % FS |
| Repeatability | ≤ ±2 % |
| Optical Stability | ≤ 0.002 A/20 min |
| Display | Color Touchscreen (English & Chinese) |
| Dimensions | 400 × 300 × 140 mm |
| Weight | 2.6 kg |
| Power Supply | AC (220 ± 22) V, (50 ± 0.5) Hz |
| Power Consumption | < 100 W |
| Humidity Limit | ≤ 85 % RH (non-condensing) |
| Data Storage | 3,500 calibration curves + 100,000 measurement records (non-volatile) |
| Interface | USB port for PC connectivity |
| Calibration | Built-in self-calibration function |
| Recovery | One-touch system restore |
| Print Support | Integrated thermal or external printer support (via USB or serial) |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TURB-6B |
| Form Factor | Benchtop / Laboratory |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.01 NTU |
| Operating Temperature | 5–40 °C |
| Accuracy | ≤ ±1% FS |
| Repeatability | ≤ ±2% FS |
| Optical Drift | <0.002 A over 20 min |
| Display | Color Touchscreen with English & Chinese UI |
| Dimensions | 400 × 300 × 140 mm |
| Weight | 2.6 kg |
| Power Consumption | <100 W |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Humidity Limit | ≤85% RH non-condensing |
| Data Storage | 3500 calibration curves + 100,000 measurement records (non-volatile) |
| Connectivity | USB port for PC data export |
| Compliance | Designed per ISO 7027:2016 principles (nephelometric detection at 860 nm), supports GLP-compliant audit trails via timestamped calibration logs and operator ID tagging |