| Max Speed | 4000 rpm |
|---|---|
| Max RCF | 2200 ×g |
| Dimensions | 500×450×280 mm |
| Power | 200 W |
| Voltage | AC 220 V, 50 Hz |
| Weight | 20 kg |
| Application Class | Clinical Hematology & Immunohematology |
| Rotor Compatibility | SERO (RBC washing), HLS (lymphocyte separation), Blood Typing Card Rotors (24-well, 8-well, 6-well) |
| Compliance | Designed for CLIA-, CAP-, and ISO 15189-aligned workflows |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | H/T16MM |
| Price | ¥4,600 |
| Centrifugation Class | Biomacromolecules |
| Max Capacity | 6 × 50 mL |
| Max Speed | 16,500 rpm |
| Dimensions | 500 × 440 × 330 mm |
| Max RCF | 18,780 × g |
| Timer Range | 0–99 h 59 min |
| Programs Stored | 20 |
| Power | 350 W |
| Noise Level | ≤65 dB(A) |
| Weight | 35 kg |
| Voltage/Frequency | AC 220 V, 50 Hz |
| Rotor Options | Fixed-angle (e.g., 12 × 1.5/2.0 mL, 6 × 50 mL), Swing-bucket (e.g., 12 × 10 mL, 2 × 48-well microplate) |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | H/T18MM |
| Price | USD 850 (est.) |
| Centrifugation Class | Biomacromolecules |
| Max Capacity | 6 × 50 mL |
| Max Speed | 18,500 rpm |
| Dimensions | 500 × 440 × 330 mm |
| Max RCF | 23,610 × g |
| Timer Range | 0–99 h 59 min |
| Programs Stored | 20 |
| Power | 350 W |
| Noise Level | ≤65 dB(A) |
| Weight | 35 kg |
| Voltage/Frequency | AC 220 V, 50 Hz |
| Rotor Options | Fixed-angle (e.g., 6 × 50 mL, 24 × 1.5/2.0 mL), Horizontal (e.g., 12 × 10 mL, 2 × 48-well microplate) |
| Brand | Jihepu (Jinan Hepu) |
|---|---|
| Origin | Shandong, China |
| Model | H1-16K |
| Type | Benchtop Centrifuge |
| Max Speed | 16500 rpm |
| Max RCF | 18757 ×g |
| Max Capacity | 12 × 5 mL |
| Dimensions (W×D×H) | 315 × 270 × 240 mm |
| Noise Level | ≤65 dB(A) |
| Power Supply | AC 220 V ±10%, 50/60 Hz, 10 A |
| Total Power | 420 W |
| Net Weight | 11 kg |
| Rotor Compatibility | Fixed-angle rotors (e.g., 12 × 5 mL, 24 × 1.5/2.2 mL, 16 × 1.5/2.2 mL) |
| Acceleration/Deceleration | 10-step programmable control |
| RCF Auto-Calculation | Yes |
| Door Lock | Electronic interlock |
| Timer Range | 1–99 min |
| Speed Accuracy | ±20 rpm |
| Centrifuge Chamber Diameter | Φ200 mm |
| Brand | Jihepu (Jinan Hepu) |
|---|---|
| Origin | Shandong, China |
| Model | H2-12K |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–12,000 rpm |
| Max RCF | 14,170 × g |
| Max Capacity | 24 × (0.25–1 mL) capillaries |
| Timer Range | 1–99 min |
| Speed Accuracy | ±20 rpm |
| Power Supply | AC 220 V ±10%, 50/60 Hz, 10 A |
| Total Power | 250 W |
| Noise Level | ≤65 dB(A) |
| Cavity Diameter | Φ200 mm |
| Dimensions (W×D×H) | 315×270×240 mm |
| Net Weight | 11 kg |
| Rotor Type | Fixed-angle capillary rotor (24-position) |
| Application Class | Hematocrit & micro-volume biological sample separation |
| Brand | Jihepu (Jinan Hepu) |
|---|---|
| Origin | Shandong, China |
| Model | H2-16K |
| Type | Benchtop High-Speed Centrifuge |
| Max Speed | 16500 rpm |
| Max RCF | 18757 ×g |
| Max Capacity | 6 × 50 mL |
| Dimensions (W×D×H) | 400 × 300 × 330 mm |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V ±10%, 50/60 Hz, 10 A |
| Total Power | 420 W |
| Net Weight | 23 kg |
| Rotor Compatibility | Fixed-angle rotors (e.g., 12×1.5/2.2 mL, 24×1.5/2.2 mL, 6×50 mL conical tubes) |
| Acceleration/Deceleration | 10 selectable profiles, including free-coast mode (>540 s) |
| Control | Microprocessor-based with variable-frequency drive |
| Safety | Electronic lid lock, overspeed protection, imbalance detection, automatic rotor recognition (via preset rotor codes) |
| Brand | Jihepu (Jinan Hepu) |
|---|---|
| Origin | Shandong, China |
| Model | H6-10KR |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Range | 10,000 rpm |
| Max RCF | 18,300 × g |
| Max Capacity | 6 × 1000 mL |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±2.0 °C |
| Timer Range | 1 min – 23 h 59 min |
| Speed Accuracy | ±20 rpm |
| Noise Level | ≤65 dB(A) |
| Dimensions (W×D×H) | 830 × 720 × 1250 mm |
| Net Weight | 268 kg |
| Power Supply | AC 220 V ±10%, 50 Hz, 30 A |
| Total Power | 4500 W |
| Rotor Cavity Diameter | Φ600 mm |
| Brand | Haier Biomedical |
|---|---|
| Origin | Shandong, China |
| Model | LX-50T2Z |
| Instrument Type | Palm-Sized Centrifuge |
| Max Speed | 5000 rpm |
| Max RCF | 1270 × g |
| Max Capacity | 8 × 1.5 mL / 2.0 mL |
| Noise Level | 40 dB(A) |
| Dimensions (W×D×H) | 152 × 142 × 122 mm |
| Net Weight | 1.2 kg |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Rated Power | 25 W |
| Speed Accuracy | ±5% |
| Rotor Configurations | (1) Fixed-angle rotor for 8 × 1.5/2.0 mL tubes |
| Compatible Tube Sizes | 0.2 mL, 0.5 mL, 1.5 mL, 2.0 mL |
| Brand | Haier Biomedical |
|---|---|
| Origin | Shandong, China |
| Model | LX-165T2R |
| Instrument Type | Benchtop Centrifuge |
| Category | Refrigerated High-Speed Centrifuge |
| Rotor Configuration | Fixed-Angle Rotor |
| Maximum Capacity | 24 × 1.5/2.0 mL |
| Max Speed | 16,500 rpm |
| Max RCF | 25,872 × g |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±2 °C |
| Acceleration Time | 20 s |
| Deceleration Time | 32 s |
| Timer Range | 1 s – 99 h 59 min 59 s |
| Speed Accuracy | ±10 rpm |
| Noise Level | ≤52 dB(A) |
| Dimensions (W×D×H) | 340 × 625 × 240 mm |
| Net Weight | 35 kg |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 700 W |
| Refrigeration System | Dual Inverter (Compressor + Fan) |
| Motor | Brushless DC Inverter Motor |
| Rotor ID Recognition | Yes |
| Dynamic Imbalance Detection | Gyroscopic Real-Time Monitoring |
| Control Interface | 7-inch Multi-Touch LCD |
| Data Export | USB Port |
| Pre-Cool Function | Yes |
| Hold Mode & Quick Spin | Yes |
| Energy-Saving Mode | Auto Standby |
| Brand | Hanil |
|---|---|
| Origin | South Korea |
| Model | Component R |
| Max Speed | 6,000 rpm |
| Max RCF | 9,660 × g |
| Max Capacity | 6 × 1000 mL |
| Temperature Range | −20°C to +40°C |
| Temp Setting Range | 0°C to ±30°C |
| Timer Range | 9 h 59 min 59 sec |
| Acceleration/Deceleration Curves | 10 |
| Stored Programs | 20 |
| Minimum Speed Increment | 1 rpm |
| Display | Graphic LCD |
| Rotor Options | 10 |
| Power Supply | AC 220 V, 60 Hz, 3.4 kW |
| Dimensions (W×D×H) | 700 × 807 × 858 mm |
| Weight | 380 kg |
| Brand | Hanil |
|---|---|
| Origin | South Korea |
| Model | FLETA5 |
| Max Speed | 5,500 rpm (fixed-angle rotor) |
| Max RCF | 5,411 × g |
| Max Capacity | 32 × 15 mL tubes |
| Timer Range | 0–99 h 59 min 59 sec |
| Acceleration/Deceleration Profiles | 10 selectable steps |
| Acceleration Time | ≤12 s (0→5,500 rpm) |
| Deceleration Time | ≤20 s (5,500→0 rpm) |
| Noise Level | <60 dB(A) |
| Stored Programs | 100 |
| Display | Graphical LCD showing rpm, RCF, time, temperature (if refrigerated), rotor radius, acceleration/deceleration profile, and program ID |
| Power Supply | AC 220 V, 50/60 Hz, 500 W |
| Motor | Brushless DC (BLDC) |
| Dimensions (W×D×H) | 570 × 475 × 325 mm |
| Net Weight | 40 kg |
| Rotor Recognition | Automatic |
| Safety Features | Imbalance detection, lid-lock interlock with emergency release, stainless-steel chamber, metal housing & lid, viewing window on lid |
| Brand | Hanil |
|---|---|
| Origin | South Korea |
| Model | J-075(A/T) |
| Maximum Speed | 19,000 rpm |
| Maximum RCF | 15,800 × g |
| Throughput Capacity | 500 L/h |
| Rotor Chamber Volume | 2.2 L |
| Motor Power | 2.2 kW |
| Display | Digital LCD (RPM, RCF, Time, Status) |
| Dimensions (W×D×H) | 630 × 360 × 1150 mm |
| Weight | 300 kg |
| Noise Level | ≤70 dB(A) |
| Safety | Quadruple Interlocked Door Lock System |
| Construction | Corrosion-Resistant Housing |
| Sample Collection | PTFE-Coated Collection Surface |
| Vibration Damping | Integrated Low-Vibration Architecture |
| Brand | Hanil |
|---|---|
| Origin | South Korea |
| Model | J-1250 |
| Instrument Type | Floor-standing Centrifuge |
| Speed Range | 10,000–30,000 rpm (Max. 15,000 rpm) |
| Max. RCF | 15,800 × g |
| Flow Rate | 2.2 L/h |
| Rotor Capacity | 9 L |
| Motor Power | 3.7 kW |
| Dimensions (W×D×H) | 500 × 845 × 1550 mm |
| Weight | 600 kg |
| Display | LCD Touchscreen (RPM, RCF, Time, Status) |
| Noise Level | ≤70 dB(A) |
| Safety | Quadruple Interlocked Door Lock System |
| Construction | Corrosion-Resistant Housing |
| Sample Collection | PTFE-Coated Collection Tray |
| Brand | Hanil |
|---|---|
| Origin | South Korea |
| Model | MF600 Plus |
| Max Speed (Fixed-Angle Rotor) | 6,000 rpm |
| Max RCF (Fixed-Angle Rotor) | 4,910 × g |
| Max Speed (Swing-Out Rotor) | 4,000 rpm |
| Max RCF (Swing-Out Rotor) | 3,399 × g |
| Max Capacity (Fixed-Angle) | 10 × 50 mL |
| Max Capacity (Swing-Out) | 4 × 750 mL |
| Brand | Hanil |
|---|---|
| Origin | South Korea |
| Model | Micro 17TR |
| Max Speed | 17,000 rpm |
| Max RCF | 25,525 × g |
| Max Capacity | 24 × 1.5/2.0 mL tubes |
| Temperature Range | −20 °C to +40 °C |
| Timer Range | 1–99 min |
| Control Interface | Digital display for speed, RCF, time, program, and temperature |
| Power Supply | 220 V, 60 Hz, single-phase, 0.8 kW |
| Dimensions (W×D×H) | 335 × 522 × 216 mm |
| Weight | 52 kg |
| Brand | Hanil |
|---|---|
| Origin | South Korea |
| Model | Supra 30K |
| Max Speed | 30,000 rpm |
| Max RCF | 98,608 × g |
| Max Capacity | 4 × 1000 mL |
| Temp Range | −20 °C to +40 °C |
| Temp Set Range | 0 °C to ±30 °C |
| Time Range | 0–99 h 59 min 59 sec + Hold mode |
| Acceleration Curves | 10 |
| Deceleration Curves | 10 |
| Stored Programs | 20 |
| Rotor Types | 15 compatible rotors |
| Effective Rotor Radius Range | 0.1 mm to max radius |
| Display | Digital panel showing RPM, RCF, time, temperature, temp limit, program ID, acceleration/deceleration profile, rotor ID, rotor radius, safety status |
| Power Supply | 220 V, 60 Hz, single-phase, 3.9 kW |
| Dimensions (W×D×H) | 710 × 1000 × 1260 mm |
| Weight | 330 kg |
| Brand | Hanil |
|---|---|
| Origin | South Korea |
| Model | Ultra 5.0 |
| Max Speed | 50,000 rpm |
| Max RCF | 254,345 × g |
| Max Capacity | 6 × 250 mL |
| Temp Range | −20 °C to +40 °C |
| Temp Setpoint Range | 0 °C to ±30 °C |
| Timer | 99 h 59 min 59 sec |
| Acceleration Profiles | 10 |
| Deceleration Profiles | 10 |
| Stored Programs | 20 |
| Rotors Supported | 10 |
| Effective Rotor Radius Range | 0.1 mm to max radius |
| Display | Real-time rpm, RCF, time, temp, temp limit, program ID, accel/decel time, rotor ID, rotor radius, safety status |
| Power | 220 V, 60 Hz, single-phase, 4.0 kW |
| Dimensions (W×D×H) | 710 × 1000 × 1260 mm |
| Weight | 430 kg |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | Mini-10K |
| Instrument Type | Palm-Sized Microcentrifuge |
| Speed Range | 3,000–10,000 rpm |
| Max. RCF | ~7,500 × g |
| Max. Capacity | 8 × 1.5 mL tubes or 2 × 8-strip PCR tubes (0.2 mL) |
| Dimensions | 175 × 156 × 125 mm |
| Weight | ≤1.5 kg |
| Power Supply | 110–220 V, 50–60 Hz |
| Noise Level | ≤55 dB(A) |
| Timer | Digital LED display with adjustable time range (0–99 min) |
| Safety | Auto-braking on lid opening, mechanical lid interlock, transparent polycarbonate lid |
| Rotor Type | Fixed-angle rotor (8-position), quick-release latch design |
| Compliance | CE-marked for laboratory use |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | Mini-10K |
| Centrifuge Type | Palm-Sized Microcentrifuge |
| Maximum Speed | 10,000 rpm |
| Maximum RCF | 7,500 × g |
| Capacity | 8 × 1.5 mL tubes (also compatible with 0.5 mL, 0.2 mL, and 2 × 8-strip PCR tubes) |
| Dimensions | 175 × 156 × 125 mm |
| Weight | ≤1.5 kg |
| Noise Level | ≤45 dB(A) |
| Power Supply | 110–220 V, 50–60 Hz |
| Rotor Type | Fixed-angle rotor (8-position, large-radius design) |
| Display | LED digital display for speed and timer |
| Motor | Brushless DC motor, maintenance-free |
| Safety | Automatic lid lock, centrifugal lid release mechanism, rotor imbalance detection |
| Brand | Hanuo |
|---|---|
| Model | Mini-10K+ |
| Type | Palm-Sized Microcentrifuge |
| Max Speed | 10,000 rpm |
| Max RCF | ~7,500 × g |
| Capacity | 8 × 1.5 mL tubes (also compatible with 0.2–0.5 mL PCR strips and microtubes) |
| Dimensions | 175 × 156 × 125 mm |
| Weight | ≤1.5 kg |
| Power Supply | 110–220 V, 50–60 Hz |
| Noise Level | ≤45 dB(A) |
| Rotor Type | Fixed-angle aluminum rotor |
| Display | LED digital display for speed and timer |
| Timer Range | 0–99 min (adjustable in 1-sec increments) |
| Compliance | CE, RoHS, ISO 9001-manufactured facility |
| Safety Features | Automatic lid lock, over-speed protection, imbalance detection, brushless DC motor |
| Brand | Hanuo |
|---|---|
| Model | Mini-4K |
| Type | Palm-Sized Microcentrifuge |
| Max Speed | 4000 rpm |
| Max RCF | 1200 × g |
| Capacity | 8 × 1.5 mL tubes (also compatible with 0.5 mL, 0.2 mL, and 2 × 8-strip PCR tubes) |
| Dimensions | 175 × 156 × 125 mm |
| Weight | ≤1.5 kg |
| Noise Level | ≤45 dB(A) |
| Power Supply | 220 V / 110 V, 50–60 Hz |
| Rotor Type | Fixed-angle horizontal rotor with quick-lock mechanism |
| Safety | Auto-stop on lid opening, transparent polycarbonate lid, electronic timer (on select models) |
| Compliance | Designed for GLP-compliant routine lab workflows |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | Mini-6K |
| Instrument Type | Palm-Sized Microcentrifuge |
| Max Speed | 6000 rpm |
| Max RCF | 3000 × g |
| Max Capacity | 8 × 1.5 mL tubes (also compatible with 0.5 mL, 0.2 mL, and 2 × 8-strip PCR tubes) |
| Dimensions | 175 × 156 × 125 mm |
| Weight | ≤1.5 kg |
| Noise Level | ≤45 dB(A) |
| Power Supply | 220 V / 110 V, 50–60 Hz |
| Rotor Type | Fixed-angle rotor with quick-lock mechanism |
| Lid Safety Interlock | Automatic motor stop upon lid opening |
| Timer Function | Electronic digital timer (model-specific |
| Compliance | Designed for general laboratory use under ISO/IEC 17025-aligned workflows |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | Mini-7K |
| Type | Palm-Sized Microcentrifuge |
| Max Speed | 7,000 rpm |
| Max RCF | ~3,400 × g |
| Capacity | 8 × 1.5 mL tubes (also compatible with 0.5 mL, 0.2 mL, and 2 × 8-strip PCR tubes) |
| Dimensions | 175 × 156 × 125 mm |
| Weight | ≤1.5 kg |
| Noise Level | ≤45 dB(A) |
| Power Supply | 220 V / 110 V, 50–60 Hz |
| Timer | Electronic digital timer |
| Safety | Lid-actuated automatic rotor stop |
| Rotor Type | Fixed-angle rotor with quick-lock mechanism |
| Compliance | Designed for GLP-compliant routine laboratory workflows |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | MINIP-2500 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–2500 rpm |
| Max RCF | 500 × g |
| Capacity | 2 × 96-well microplates (standard PCR plates, skirted or unskirted) |
| Rotor Type | Fixed-angle vertical rotor |
| Dimensions | 219 × 190 × 186 mm (W × D × H) |
| Weight | 3 kg |
| Power Supply | AC 100–230 V, 50–60 Hz |
| Motor | Brushless DC motor |
| Acceleration/Deceleration | Full speed in <3 s |
| Operating Modes | Momentary (pulse) and timed (1–99 s) |
| Safety | Lid interlock, auto-brake, over-speed protection |
| Noise Level | <45 dB(A) |
| Brand | Heathrow Scientific |
|---|---|
| Origin | USA |
| Model | Gusto |
| Instrument Type | Palm-Sized Centrifuge |
| Speed Range | 500–12,500 rpm (in 100-rpm increments) |
| RCF Max | 9,800 × g |
| Capacity | 12 × 1.5 mL tubes (compatible with 0.2/0.5/1.5/2.0 mL microtubes) |
| Timer Range | 1 s – 30 min (1-s increment) |
| Dimensions | 203 × 171 × 114 mm |
| Power Input | 100–240 V AC, 50/60 Hz |
| Safety Features | Lid interlock, imbalance detection, automatic rotor stop |
| Noise Level | <55 dB(A) |
| Compliance | CE, RoHS, IEC 61010-1 |
| Brand | Heathrow Scientific |
|---|---|
| Origin | USA |
| Model | Sprout |
| Type | Palm-Sized Centrifuge |
| Max Speed | 6000 rpm |
| Max RCF | 2000 × g |
| Max Capacity | 6 × 1.5 mL |
| Dimensions | 153 × 108 × 124 mm |
| Rotor Types | Fixed-angle rotor (6-position, 1.5 mL), with included adapters for 0.2 mL and 0.5 mL tubes, plus 16-position 0.2 mL strip-tube rotor |
| Safety Certifications | CE, cETL, ETL |
| Motor | Brushless DC motor |
| Operating Modes | Push-button start & lid-actuated start |
| Lid Interlock | Automatic rotor stop upon lid opening |
| Noise Level | <45 dB(A) |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Hebei (Jihepu) |
|---|---|
| Origin | Shandong, China |
| Model | H3-16KR |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm (Max. 16,500 rpm) |
| Max. RCF | 18,757 × g |
| Max. Capacity | 6 × 50 mL |
| Temperature Range | –20 °C to +40 °C |
| Temp. Stability | ±1.0 °C |
| Timer | 1–99 min |
| Acceleration/Deceleration | 10 selectable ramps (Ramp 9: free deceleration >540 s) |
| Power Supply | AC 220 V ±10%, 50 Hz, 15 A |
| Total Power | 800 W |
| Noise Level | ≤65 dB(A) |
| Dimensions (W×D×H) | 480 × 560 × 360 mm |
| Net Weight | 70 kg |
| Rotor Auto-ID | Yes |
| Safety Features | Lid interlock, overspeed protection, imbalance detection, rotor recognition |
| Brand | Jihepu (Jinan Hepu) |
|---|---|
| Origin | Shandong, China |
| Model | H3-18KR |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–18,500 rpm |
| Max RCF | 25,500 × g |
| Max Capacity | 4 × 100 mL |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1.0 °C |
| Timer Range | 1 s to 99 min 59 s |
| Acceleration/Deceleration | 10 selectable ramps |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V ±10%, 50 Hz, 15 A |
| Total Power | 800 W |
| Dimensions (W×D×H) | 480 × 560 × 360 mm |
| Net Weight | 75–80 kg |
| Rotor Material | High-strength carbon-fiber composite |
| Compliance | CE-marked design principles |
| Brand | Hebei HOP |
|---|---|
| Origin | Shandong, China |
| Model | H1-16KR |
| Max Speed | 16500 rpm |
| Max RCF | 18757 ×g |
| Max Capacity | 12 × 5 mL |
| Temperature Range | −20 °C to 40 °C |
| Temp. Accuracy | ±1.0 °C |
| Timer Range | 1–99 min |
| Acceleration/Deceleration | 10 steps |
| Programs Stored | 40 |
| Noise Level | ≤65 dB(A) |
| Dimensions (W×D×H) | 510×280×270 mm |
| Net Weight | 40 kg |
| Power Supply | AC 220 V ±10%, 50 Hz, 10 A |
| Total Power | 550 W |
| Brand | Hepu |
|---|---|
| Origin | Shandong, China |
| Model | H2-16KR |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm (Max. 16,500 rpm) |
| Max. RCF | 18,757 × g |
| Max. Capacity | 6 × 50 mL |
| Temperature Range | –20 °C to +40 °C |
| Temp. Stability | ±1.0 °C |
| Timer | 1–99 min |
| Acceleration/Deceleration | 10 selectable ramps (Ramp 9: free deceleration >540 s) |
| Power Supply | AC 220 V ±10 %, 50 Hz, 10 A |
| Noise Level | ≤65 dB(A) |
| Dimensions (W×D×H) | 480 × 560 × 360 mm |
| Net Weight | 65 kg |