Chemical Analysis Instruments
Filter
Showing 6541–6570 of 10330 results
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SDC-1000 |
| Sample Capacity | 1–12 positions |
| Concentration Vessels | 50 mL, 150 mL, and 200 mL |
| Endpoint Detection | Optical dryness sensor per channel |
| Endpoint Volume Options | 1.0 mL, 0.5 mL, or near-dry (~0.1 mL) |
| Water Bath Temperature Range | Room temperature +5 °C to 100 °C (±0.3 °C) |
| Nitrogen Blow Time | 0–9999 min |
| Nitrogen Pressure Control | 0–0.10 MPa (10-step adjustable, 0.01 MPa increments) with auto-regulation |
| Inlet Nitrogen Supply Pressure | 0.20–0.80 MPa |
| Max Allowable Inlet Pressure | 1.00 MPa |
| Gas Consumption | ~500 mL/min per channel at 0.10 MPa |
| Sensitivity Adjustment | Continuously variable optical endpoint detection |
| Control Interface | Color LCD touchscreen |
| Operating Modes | Manual / Timed / Volume-based endpoint |
| Safety Features | Lid-open detection, low-water alarm & auto-refill, low-pressure alarm, 60-sec pause/resume memory |
| Materials | Plasticizer-free silicone seals, food-grade PTFE gas tubing |
| Exhaust System | Integrated high-efficiency fume extraction |
| Drain Valve | Integrated for bath water replacement |
| Heating Power | 2000 W |
| Power Supply | 220 V / 60 Hz |
| Dimensions (W×D×H) | 600 × 540 × 400 mm |
| Weight | 28 kg |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SKD-100 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automatic |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time | 3–8 min per sample |
| Repeatability | RSD ≤ 0.5% |
| Sample Weight Capacity | ≤6 g (solid) / ≤16 mL (liquid) |
| Nitrogen Recovery Rate | >99.5% |
| Power Consumption | 750–1500 W |
| Dimensions (L×W×H) | 370 × 300 × 680 mm |
| Display | LED digital display |
| Alkali Addition Time | 0–99 s |
| Distillation Volume Control | 14–28 mL/min |
| Programmable Programs | 10 pre-set distillation/alkali addition protocols |
| Safety Features | Overpressure protection, dry-run prevention via real-time liquid level monitoring, emergency stop function |
| Housing Material | Integrated molded ABS engineering plastic |
| Tubing Material | PEIOU proprietary acid-/alkali-/heat-resistant polymer tubing |
| Weight | 15 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Water Supply Requirement | ≥0.15 MPa pressure, ≤20 °C inlet temperature |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-100 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automated |
| Nitrogen Determination Range | 0.1–240 mg N |
| Sample Weight Capacity | ≤5 g (solid) / ≤15 mL (liquid) per sample |
| Alkali/Acid Addition Time Control | 0–99 s (segmented) |
| Distillation Time Setting | 0–99 min |
| Distillation Rate | 14–28 mL/min |
| Power Adjustment Range | 750–1500 W |
| Recovery Rate | >99.5% |
| Repeatability | RSD ≤0.5% |
| Dimensions (L×W×H) | 370×300×680 mm |
| Net Weight | 15 kg |
| Display | LED digital |
| Data Storage | 10 programmable distillation/alkali addition methods |
| Safety Features | Real-time liquid level monitoring, overpressure protection, dry-run prevention, emergency stop |
| Housing Material | Molded ABS engineering plastic (acid/alkali resistant) |
| Tubing | PEIU proprietary corrosion-resistant high-temp tubing |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Water Supply Requirement | ≥0.15 MPa pressure, ≤20 °C inlet temperature |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | SKD-100 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automatic |
| Nitrogen Measurement Range | 0.1–240 mg N |
| Distillation Time | 3–8 min per sample |
| Repeatability | RSD < 0.5% |
| Sample Weight Capacity | Solids < 6 g, Liquids < 16 mL |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Rating | 1500 W |
| Dimensions (L×W×H) | 370 × 300 × 680 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-1000 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–200 mg N per sample |
| Distillation Time | 3–8 min per sample |
| Repeatability | ≤ ±0.5% RSD |
| Sample Weight Capacity | Solids 0.1–2 g |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | ~1500 W |
| Dimensions (L×W×H) | 450 × 400 × 550 mm |
| Linear Range | 0.1–200 mg N |
| Linearity Error at 4× Nitrogen Load | ≤ ±1% |
| Compatible Standard Acid Concentrations | 0.01–0.5 mol/L HCl or H₂SO₄ |
| Titration Resolution | 0.8 µL/step |
| Acid Delivery Precision | ≤0.002 µL/step |
| Alkali Addition | Programmable segmented dosing (1–10 pulses, 0–15 s interval) |
| Delay Time Setting | 0–1800 s (for nitrate-nitrogen analysis) |
| Reagent Pump Volume Range | 0–150 mL (1 mL increments) |
| Steam Power Adjustment | Continuously variable |
| Safety Features | Dual-level steam chamber monitoring, condensate flow interruption protection, door interlock sensing, real-time cooling water pressure/flow detection, reagent level monitoring, and jacket temperature control |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-1000 |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–240 mg N per sample |
| Distillation Time | 3–8 min/sample |
| Repeatability | RSD ≤ 0.5% |
| Sample Weight Capacity | ≤6 g (solid) or ≤20 mL (liquid) |
| Nitrogen Recovery Rate | >99.5% |
| Dimensions (L×W×H) | 500 × 350 × 720 mm |
| Titration Resolution | 0.8 µL/step (auto-adjusted by titrant concentration) |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-1100 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–200 mg N |
| Linear Range | 0.1–200 mg N |
| Sample Weight (Solid) | 0.1–5 g |
| Distillation Time per Sample | 3–5 min |
| Repeatability | ≤0.5% CV |
| Recovery Rate | ≥99.5% |
| Power Consumption | ~800 W |
| Dimensions (L×W×H) | 450 × 350 × 500 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-180 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automatic |
| Nitrogen Measurement Range | 0.1–240 mg N |
| Distillation Time Setting | 0–99 min |
| Repeatability | RSD ≤ 0.5% |
| Sample Capacity | Solid ≤ 20 g/sample |
| Nitrogen Recovery Rate | > 99.5% |
| Adjustable Power Output | 1500 W |
| Dimensions (L×W×H) | 370 × 300 × 680 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-1800 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–240 mg |
| Distillation Time per Sample | 3–8 min |
| Repeatability (RSD) | ≤0.5% |
| Sample Weight Capacity | ≤5 g (solid) or ≤15 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 750–1500 W |
| Dimensions (L×W×H) | 370 × 300 × 680 mm |
| Linearity Range | 0.1–240 mg nitrogen |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-2000 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–300 mg N |
| Sample Weight Capacity | Solids 0.1–5 g |
| Distillation Time per Sample | 2–6 min |
| Repeatability | ≤ ±0.3% RSD |
| Recovery Rate | ≥99.8% |
| Linearity Range | 0.1–300 mg N |
| Linearity Error at 4× Nitrogen Load | ≤ ±0.8% |
| Compatible Standard Acid Concentration | 0.01–1.0 mol/L HCl or H₂SO₄ |
| Power Consumption | ~1800 W |
| Dimensions (L×W×H) | 500×450×600 mm |
| Titration Precision | ±0.15% |
| Adjustable Alkali Addition Steps | 1–10 segments with 0–15 s intervals |
| Delay Time Setting | 0–1800 s |
| Reagent Pump Volume Range | 0–150 mL (1 mL resolution) |
| Distillation Steam Continuity | Continuous steam generation with auto-refill without interruption |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-2000 |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time per Sample (incl. titration) | 3–8 min |
| Repeatability | RSD < 0.5% |
| Sample Weight Capacity | ≤6 g (solid), ≤16 mL (liquid) |
| Nitrogen Recovery Rate | >99.5% |
| Power Consumption | 750–1500 W |
| Dimensions (L×W×H) | 500 mm × 350 mm × 720 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-3000 |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–240 mg N |
| Sample Throughput | 1 sample per 3–8 min |
| Repeatability | RSD < 0.5% |
| Sample Weight Capacity | ≤6 g (solid) or ≤16 mL (liquid) |
| Nitrogen Recovery Rate | >99.5% |
| Dimensions (L×W×H) | 500 × 350 × 720 mm |
| Titration Resolution | ≤0.001 µL/step |
| Minimum Titration Volume | 0.8 µL/step (auto-adjusted per titrant concentration) |
| Distillation Flow Rate | 15–30 mL/min (adjustable) |
| Data Storage | Unlimited (on-board + wireless PC sync) |
| Compliance | Designed for GLP/GMP-aligned workflows with audit trail, user-level access control (3-tier password), and full data traceability |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-5000 |
| Instrument Type | Fully Automated Kjeldahl Nitrogen Determinator |
| Nitrogen Determination Range | 0.1–500 mg N per sample |
| Cation Exchange Capacity (CEC) Range | 1–100 cmol/kg |
| Sample Weight | Solid (e.g., soil): 0.5–10 g |
| Liquid | 1–100 mL |
| Distillation Time | 2–5 min per sample |
| Repeatability | ≤±0.2% for nitrogen |
| Recovery Rate | ≥99.8% for nitrogen |
| Linear Range | 0.1–500 mg N |
| Linearity Error at 4× Nitrogen Load | ≤±0.5% |
| Compatible Standard Acid Concentration | 0.01–1.5 mol/L HCl or H₂SO₄ |
| Power Consumption | ~2000 W |
| Dimensions (L×W×H) | ~550×500×650 mm |
| Titration Resolution | 0.8 µL/step |
| Pump Accuracy | RSD <0.002 µL/step |
| Repeatability (RSD) | <0.5% |
| Delay Time Setting | 0–1800 s |
| Digestion Tube Compatibility | 300 mL and 650 mL tubes |
| Dual-Mode Operation | Manual & Automatic |
| Distillation Power | Adjustable |
| Safety Features | Real-time distillation cup temperature monitoring, condenser water flow/pressure auto-detection, acid/alkali/boric acid/diluent level sensors, door-closed status verification, dry-burn prevention via dual liquid-level modeling |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-5000 |
| Instrument Type | Fully Automated Kjeldahl Nitrogen Determinator |
| Nitrogen Range | 0.1–240 mg N |
| CEC Range | 0.07–140 cmol<sub>c</sub>/kg |
| Digestion/Steam Distillation Time | 3–8 min per sample |
| Repeatability | RSD ≤ 0.5% |
| Sample Capacity | ≤6 g (solid) or ≤16 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Dimensions (L×W×H) | 500 × 350 × 720 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-800 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automated |
| Nitrogen Determination Range | 0.08–240 mg N |
| Sample Weight Capacity | Solid ≤6 g, Liquid ≤16 mL |
| Distillation Time | 3–8 min (typical) |
| Repeatability | RSD < 0.5% |
| Recovery Rate | ≥99.5% |
| Adjustable Distillation Power | 750–1500 W |
| Dimensions (L×W×H) | 370 × 300 × 680 mm |
| Cooling Water Flow Requirement | >1.5 L/min (inlet water temperature ≤20 °C) |
| Operating Pressure | >0.15 MPa |
| Data Storage | ≥100 distillation programs, ≥1000 sample records |
| Safety Features | Dual-level liquid detection, real-time temperature monitoring (digestion cup & collector), door-closed status sensing, intermittent alkali addition, automatic reagent dosing (acid, alkali, boric acid, diluent), overheat protection, dry-run prevention, and coolant flow interruption detection |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SKD-800 |
| Instrument Type | Kjeldahl Nitrogen Analyzer |
| Automation Level | Semi-Automatic |
| Nitrogen Determination Range | 0.08–240 mg N |
| Distillation Time per Sample | 3–8 min |
| Repeatability (RSD) | ≤0.5% |
| Sample Weight Capacity | Solids < 6 g |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Rating | 1500 W (adjustable) |
| Dimensions (L×W×H) | 370 × 300 × 680 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SKD-800 |
| Price Range | USD 2,800 – 7,200 (FOB Shanghai) |
| Instrument Type | Kjeldahl Nitrogen Analyzer |
| Automation Level | Semi-Automatic |
| Nitrogen Measurement Range | 0.08–240 mg N |
| Distillation Time | 1–99 min |
| Repeatability | RSD < 0.5% |
| Sample Weight Capacity | Solids ≤ 5 g, Liquids ≤ 15 mL |
| Nitrogen Recovery Rate | > 99.5% |
| Adjustable Distillation Power | 1500 W |
| Dimensions (L×W×H) | 370 × 300 × 680 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD200 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automatic |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time | 3–8 min |
| Repeatability | RSD < 0.5% |
| Sample Weight Capacity | ≤6 g (solid) / ≤16 mL (liquid) |
| Nitrogen Recovery Rate | 99.5% |
| Adjustable Distillation Power | 1500 W |
| Dimensions (L×W×H) | 370 × 300 × 680 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | V100 |
| Price Range | USD 2,800 – 7,000 (FOB Shanghai) |
| Titration Mode | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 1 µg |
| Moisture Content Range | 100 ppm to 100% w/w |
| Accuracy | ±0.3% relative |
| Minimum Dispensing Increment | 1/20,000 of burette volume |
| Titration Control Precision | 1 µg (equivalent to 0.001 mL at 1 mg/mL KF reagent concentration) |
| Brand | Other Brands |
|---|---|
| Origin | Domestic |
| Manufacturer Type | General Distributor |
| Origin Category | Imported |
| Model | PEM Photoelastic Modulator (Domestic) |
| Price | Upon Request |
| Brand | PerfectLight |
|---|---|
| Model | DT-Series (e.g., DT 350, DT 405, DT 550, etc.) |
| Substrate Material | Fused Silica |
| Diameter | 63 mm |
| Clear Aperture | >57 mm |
| Center Wavelength Range | 320–700 nm (UV-Vis) |
| Full Width at Half Maximum (FWHM) | 20 nm ±3 nm |
| Blocking Range | OD ≥4 from 200–1200 nm (typical) |
| Surface Quality | 20–10 scratch-dig |
| Parallelism | <3 arcsec |
| Transmission Peak | >85% (typical) |
| Operating Temperature | –20 °C to +70 °C |
| Compliance | ISO 9001-manufactured, RoHS-compliant |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | UVref |
| Filter Type | Cut-On / Cut-Off, Bandpass, and Narrowband |
| Substrate Material | Fused Silica (Quartz) |
| Diameter | 63 mm |
| Clear Aperture | >57 mm |
| Spectral Range | 320–2500 nm |
| Optical Density (OD) @ Blocking Region | ≥4.0 (typ.) |
| Surface Quality | 20–10 scratch-dig |
| Parallelism | <3 arcsec |
| Coating Type | Hard Dielectric Multilayer |
| Incident Angle | 0° ± 2° (for specified spectral performance) |
| Compliance | ISO 9001-manufactured optical components |
| Application Domain | Laboratory-based NIR, UV-Vis, and FT-NIR spectroscopy systems |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | Custom 2 |
| Pricing | Available Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Custom 9 |
| Pricing | Upon Request |
| Detection Principle | Laser Raman Spectroscopy |
| Target Analytes | Monoethanolamine (MEA), Diethanolamine (DEA) |
| Concentration Range | 0–55% (w/w) |
| Accuracy | ≤ ±1% FS |
| Response Time | ≤ 30 s |
| Operating Temperature | −10 to 50 °C |
| Operating Humidity | 15–85% RH |
| Probe Configuration | In-situ or Extractive |
| System Architecture | Modular (Separated Spectrometer Unit & Immersion Probe) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | Customized-6 |
| Pricing | Available Upon Request |
| Brand | PERIC |
|---|---|
| Model | GNF-TR-DP |
| Sensor Principle | Ultra-Thin Aluminum Oxide Capacitive |
| Measurement Range | –100 °C to +20 °C (Td) |
| Accuracy | ±2 °C @ +20 °C to –60 °C Td |
| Repeatability | ±0.5 °C |
| Stability | ±1% F.S. / 7 days |
| Response Time (63% / 90%) | 5 s / 10 s (–60 °C → –20 °C Td) |
| Explosion Protection | Ex db IIC T6 Gb (ATEX-compliant) |
| Ingress Protection | IP66 |
| Power Supply | 24 V DC |
| Communication Interface | TTL-level Serial Port |
| Analog Output | 4–20 mA (hardware-ready, software-configurable) |
| Mechanical Interface | M20×1.5 thread (display unit) |
| Operating Ambient Temperature | –10 °C to +50 °C |
| Relative Humidity | <90% RH (non-condensing) |
| Sample Pressure | Atmospheric ±10% (vented to ambient) |
| Sample Flow Rate | 3–5 L/min |
| Sensor Lifetime | >2 years (normal operation) |
| Instrument Lifetime | >5 years (normal operation) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | PR-GLRSA |
| Quotation | Upon Request |
| Detection Channels | 2 (simultaneous) |
| Target Gases | H₂, CO, C₃H₈, C₃H₆ |
| Concentration Ranges | H₂: 0–50% vol, CO: 0–10% vol, C₃H₈: 0–50% vol, C₃H₆: 0–80% vol |
| Accuracy | ≤ ±3% FS |
| Response Time | ≤ 30 s |
| Explosion Protection | Ex db ec ib pzc II C T3 Gc (Positive-Pressure Purged & Pressurized) |
| Operating Temperature | 5–40 °C |
| Power Supply | AC 220 V / 50 Hz, ≤ 800 W (host only) |
| Purge Gas | Clean, oil-free, dry, particle-free compressed air, 0.4–0.8 MPa |
| Brand | PERIC |
|---|---|
| Model | PR-LM |
| Type | Portable / Handheld Raman Spectrometer |
| Origin | Hebei, China |
| Manufacturer | PERIC Instrument Co., Ltd. |
| Measurement Range | 0–100% (v/v) |
| Detection Limit | 1 µmol/mol |
| Accuracy | ±0.1% (full scale) |
| Analysis Time | 1–300 s (user-configurable) |
| Sample Inlet | Integrated diaphragm pump |
| Dimensions (L×W×H) | 557 × 420 × 330 mm |
| Weight | <23 kg |
| Target Gases | H₂, N₂, O₂, CO, CO₂, CH₄, NH₃, H₂O, H₂S, C₂H₂, C₂H₄, C₂H₆, C₃H₆, and other hydrocarbons and inorganic gases |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Region | Domestic (China) |
| Model | PR-LR |
| Pricing | Upon Request |
| Gas Detection Range | N₂, O₂, H₂, CH₄, CO, CO₂, C₂H₆, C₂H₄, C₂H₂, C₃H₈, C₃H₆, C₄H₁₀, NO, NO₂, SO₂, H₂S |
| Accuracy | ≤±1% FS for components >1% full scale |
| Resolution | ≤0.01% (for >1% FS) |
| Analysis Time | 10–30 s (adjustable) |
| Laser Wavelength | 532 nm |
| Laser Linewidth | ≤0.1 nm |
| Spectral Range | 0–4200 cm⁻¹ |
| Spectral Resolution | 5 cm⁻¹ |
| Power Supply | 220 VAC, 50 Hz |
| Max. Power Consumption | ≤300 W |
| Operating Temperature | 10–35 °C |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PR-RM |
| Instrument Type | Online Raman Spectrometer |
| Gas Species | Benzene, Nitrogen, Hydrogen, Carbon Dioxide, Carbon Monoxide, Carbonyl Sulfide, Hydrogen Sulfide, Oxygen, Methane |
| Range | 0–100 %vol |
| Detection Limit | ≤50–100 ppm (gas-dependent) |
| Accuracy | ≤2 %FS |
| Measurement Cycle | 1–30 s (adjustable) |
| Sampling Method | Pump-aspirated with integrated pre-treatment |
| Environmental Robustness | Rated for high-pressure, high-temperature, high-humidity, high-dust, and hazardous-area operation |
| Maintenance | Consumable-free design |
