Chemical Analysis Instruments
Filter
Showing 7291–7320 of 10707 results
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QT-330 |
| Pricing | Available Upon Request |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.1 °C |
| Accuracy at 50 °C | ±0.1 °C |
| Repeatability | ±0.1 °C |
| Heating Chamber Dimensions | 350 mm × 45 mm × 40 mm |
| Display | Dual-line LED with Touch-sensitive Controls |
| Safety Features | Over-temperature Alarm & Auto Cut-off |
| Mounting | Magnetic-latch Lid & Dual Orientation (Vertical/Horizontal) |
| Viewing Window | Integrated Tempered Glass Panel |
| Column Capacity | 1–2 Standard HPLC Columns |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QuanX |
| Configuration | Benchtop or Floor-Standing |
| Detector Options | Liquid-Nitrogen-Cooled or Electrically Cooled Si(Li) Detector |
| Elemental Range | Na (11) to U (92) |
| Detection Limit | Typically sub-ppm to 100% w/w |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | TS-1 |
| Price Range | USD 1,400 – 2,800 |
| Instrument Type | Capillary Electrophoresis (CE) Accessory |
| Sample Analysis | Organic Analysis |
| Window Width | 2 mm |
| Processing Time | ≤5 s |
| Compatible Capillary OD | ≤1 mm |
| Coating Removal | Polyimide only |
| Optical Integrity Preserved | Yes |
| Mechanical Integrity Preserved | Yes |
| Key | Brand: Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | A-Z Series |
| Price Range | USD 1–1,400 (FOB) |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | Si+SiO₂ Thin-Film QCM Substrate |
| Pricing | Available Upon Request |
| Crystal Orientation | <100> or <111> |
| Doping Type | N-type or P-type |
| Fabrication Method | Dry or Wet Oxidation |
| SiO₂ Thickness | 50 nm – 1 µm (customizable) |
| Si Wafer Thickness | 0.5 mm |
| Standard Dimensions | Ø100 mm (4") or Ø50 mm (2") |
| Surface Configuration | Single-Side or Double-Side Oxidized |
| Packaging | Class 1000 Cleanroom-Processed, Sealed in Class 100 Clean Bags |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | QCM-25-2IN |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | R-3000 / R-3000QE |
| Price | Upon Request |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | BAM |
| Stroke | 10 mm |
| Speed | 141 rpm |
| Load Range | 0.5 kg to 36 kg (9 calibrated weights) |
| Ceramic Pin | Ø10 × 15 mm |
| Ceramic Plate | 25 × 25 × 5 mm |
| Surface Roughness (Ceramic Plate) | 9–32 µm |
| Net Weight | 62 kg |
| Electrical Supply Options | 380 V / 3 Ph / 50 Hz |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | HPV |
| Pressure Vessel Material | AISI 316 Stainless Steel |
| Internal Diameter | 50 mm |
| Internal Height | 94.5 mm |
| Burst Disc Rating | 6.2 bar ±10% at 22 °C |
| Nozzle Orifice Diameters | 1.0, 2.0, 3.5, 6.0, 9.0, 12.0, 16.0, 24.0 mm |
| Compliance | UN Manual of Tests and Criteria, Part I, Section 12 (Test Series 1) |
| Accessories | Tripod Stand, Base Plate, Protective Sleeve, 8 Nozzle Plates, 20 Burst Discs |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model Designation | MV-TS 24-135 |
| Temperature Range | 60–140 °C |
| Control Accuracy | ±0.1 °C |
| Heating Block | 24-position anodized aluminum, 20.5 mm bore (19 mm per MIL-STD-286C), 280 mm depth |
| Sample Tubes | 24 × stainless steel cylindrical tubes, OD 20 mm (18 mm per MIL-STD-286C), ID 17 mm (15 mm per MIL-STD-286C), L 290 mm, with vented retaining clamps and stainless steel suspension hooks |
| Detection Medium | 200 pcs methyl violet impregnated indicator papers (N₂O-sensitive) |
| Temperature Sensor | PT100 Class A |
| Safety | Independent overtemperature cut-off device |
| Controller | Dedicated PID-based programmable temperature controller with isolated ISO-compliant housing |
| Display | Dual digital LED (setpoint & real-time temperature) |
| Power Supply | 230 V AC, 50–60 Hz |
| Power Consumption | 1500 VA |
| Cable Length | ~2 m |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | OXISTAR |
| Chamber Configuration | Single (310-0003) or Dual (310-0001) |
| Max Operating Pressure | 21 bar |
| Oxygen Pre-Pressure | 25 ± 1 bar |
| Compressed Air Pre-Pressure | 7 ± 0.5 bar |
| Burst Disc Rating | 32 ± 7.5% bar |
| Max Temperature | 150 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Temp Uniformity | ±0.1 °C at 70 °C, ±0.2 °C at 150 °C |
| Pressure Sensor Range | 0–25 bar, ±0.5% FS |
| Chamber Volume | 4 L per cavity |
| Heating Power (Single) | 330 VA |
| Total Power Consumption | 720 VA (Dual), 360 VA (Single) |
| Dimensions (W×D×H) | 87 × 66 (45) × 42 cm |
| Weight | 58 kg (Dual), 42 kg (Single) |
| Electrical Supply | 230 V ±10% |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | PVC |
| Heating Range | RT–210 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Block | 40-position, Ø5.2 × 65 mm wells |
| Temperature Sensor | PT100 |
| Controller | Digital PID |
| Sample Tubes | 100 pcs, Ø5 × 110 mm |
| Power Consumption | 500 W |
| Electrical Supply | 230 V / 50 Hz |
| Weight | 8.5 kg |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | Thermogravimetric Stability Tester |
| Max Operating Temperature | 110 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Block | Aluminum, 21-hole, Ø31 mm × 170 mm depth |
| Temperature Sensor | PT100 |
| Overtemperature Cut-off | 120 °C |
| Sample Tubes | 21 × cylindrical borosilicate glass tubes, Ø30 ± 0.3 mm × 230 ± 2 mm, ground neck with stopper |
| Optical Detection System | UV-A fluorescent lamp (365 nm), non-glaring, rigidly mounted on solid support |
| Electrical Supply | 230 V, 50–60 Hz |
| Power Consumption | 1200 VA |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | VP250 Lubricating Oil Evaporation Loss Tester |
| Temperature Range | 150–300 °C |
| Temperature Accuracy | ±0.2 °C (at 250 °C: ±0.1 °C) |
| Pressure Range | up to 21 mmWS |
| Pressure Accuracy | ±0.02 mmWS |
| Power Supply | 230 V/110 V ±10%, 50/60 Hz, 1300 VA |
| Max. Power Consumption | 950 VA at 250 °C |
| Dimensions | 278 × 316 × 300 mm |
| Net Weight | 18 kg |
| Display | LCD with 0.1 °C resolution for temperature, pressure, and elapsed time |
| Control System | Digital PID microprocessor with auto-tuning |
| Safety Features | Independent overtemperature cut-off circuit, dual-sensor redundancy, audible/visual fault alerts |
| Calibration | PT100 sensor calibrated against certified mercury thermometer (traceable to national standards), deviation <0.5 °C |
| Brand | RADOM |
|---|---|
| Model | Altair / Mira / Sirius |
| Origin | Imported |
| Plasma Gas Compatibility | Air, N₂, CO₂, H₂, H₂O vapor |
| Max. Plasma Temperature | >5500 °C (Altair/Mira), >6000 °C (Sirius core) |
| Power Options | Up to 100 kW (Sirius) |
| Cooling | Electrodeless, water-free operation |
| Compliance | Designed for ISO/IEC 17025 laboratories, compatible with GLP/GMP data integrity requirements |
| Interface | Modular ICP-MS sampler cone adapters (Agilent, Thermo Fisher, PerkinElmer, Nu Instruments) |
| Brand | Endress+Hauser |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RAMANRXN2 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Excitation Wavelength Options | 532 nm, 785 nm, or 1000 nm |
| Channel Configuration | Single-Channel (Standard), Optional 4-Channel Multiplexing |
| Probe Compatibility | Rxn-10 (with accessory optics), Rxn-30, Rxn-40, Rxn-41, Rxn-45, Rxn-46 |
| Hazardous Area Certifications | ATEX, IECEx, North American Class I Div 1/2, Class II Div 1/2 |
| Installation Form Factor | Benchtop or Mobile Cart-Mounted |
| Regulatory Compliance | Designed for cGMP/GLP environments, supports FDA 21 CFR Part 11–compliant audit trails when integrated with validated software platforms |
| Software Interface | Embedded touchscreen control with optional remote web-based access via Ethernet/Wi-Fi |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Nanophoton RAMANdrive |
| Instrument Type | Fourier Transform Raman Spectrometer |
| Spatial Resolution | 350 nm (X), 500 nm (Y), 1 µm (Z) |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported Instrument |
| Model | RamSPEC-VUV-0.3-0.6 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 140–550 nm |
| Spectral Resolution | 0.1 nm |
| Spatial Resolution | 1 µm |
| Minimum Raman Shift | 0 cm⁻¹ |
| Spectral Repeatability | ≤ ±0.01 cm⁻¹ |
| Brand | Ransburg |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 76652-01 / 76652-02 / 76652-03 / 76652-04 |
| Power Supply | 9V Alkaline Battery |
| High Voltage Range | ±0–199.9 kV |
| Short-Circuit Current Range | ±0–1999.9 µA |
| Conductance Range | 0.01–199.9 mS/cm (with 7922-00 Paint Probe) |
| Resistivity Range | 10⁰–10⁹ Ω·cm (typical for solvent-based and waterborne coatings) |
| Electrode Material | Corrosion-Resistant Stainless Steel |
| Compliance | Designed for industrial electrostatic spray process control per ITW Ransburg engineering specifications |
| Brand | RapidXAFS |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Model | RapidXAFS 1M |
| Price Range | USD 420,000 – 700,000 |
| X-ray Source Power | 1.6 kW & 3.0 kW |
| Monochromatic X-ray Photon Flux | 1,000,000 photons/s/eV |
| Minimum Detectable Elemental Concentration | 1 wt% |
| Tunable X-ray Absorption Energy Range | 4.5 keV – 15 keV (extendable) |
| Brand | RapidXAFS |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RapidXAFS 2M |
| Price Range | USD 700,000 – 1,400,000 |
| X-ray Source Power | 1.6 kW & 3.0 kW |
| Monochromatic X-ray Photon Flux | > 2,000,000 photons/s/eV at 8 keV |
| Minimum Detectable Elemental Concentration | 0.5 wt% (on CN-supported matrix) |
| Tunable X-ray Absorption Energy Range | 4.5 keV – 20 keV |
| Brand | RapidXAFS (Anhui Absorption Spectrometer) |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic |
| Model | RapidXAFS In Situ Cell |
| Price Range | USD 280,000–420,000 |
| X-ray Source Power | ≤100 W |
| Minimum Detectable Elemental Concentration | 1 wt% |
| X-ray Absorption Energy Range | 2.5–5 keV |
| XAFS Spectrum Acquisition Speed | 1 spectrum/s |
| Brand | RapidXAFS |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RapidXAFS Emission Spectrometer |
| Price Range | USD 390,000 – 490,000 |
| X-ray Source Power | ≤100 W |
| Minimum Detectable Elemental Content | ≤1 wt% |
| Tunable X-ray Absorption Energy Range | 2.5–5 keV |
| Fluorescence Detection Energy Range | 5–15 keV |
| Detectable Edges | 3d transition metal K-edges, 5d transition metal L-edges, actinide L-edges |
| Energy Resolution | ≤1.5 eV @ Cu Kα |
| Detector Efficiency | ≥1×10¹¹ counts per photon |
| Spectral Reproducibility | Energy drift <50 meV across repeated scans |
| Ambient Control | Helium-purged measurement chamber |
| Monochromator | High-purity Si or Ge single-crystal analyzer |
| In Situ Capability | Modular reaction cells for high/low temperature, multiphase catalysis, electrocatalysis, and operando studies |
| Data Acquisition | Real-time XES spectral output during acquisition |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | AT200 |
| Pricing | Available upon request |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Auto GS 30 |
| Instrument Type | Multifunctional Gas Autosampler |
| Max Sample Capacity | 30 positions |
| Minimum Sample Volume | 0.25 mL |
| Quantitative Loop Volume | 1 mL |
| Positioning Accuracy | ±0.3° |
| Actuation Method | Valve-actuated switching |
| Needle Cleaning | Bidirectional pneumatic purge (forward + reverse) |
| Replicate Injections per Sample | Up to 30 |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Manufacturer |
| Product Category | Flow Injection Analyzer |
| Model | iLab-FIA |
| Wavelength Range | 400–1100 nm |
| Flow Cell Path Length | 10 mm |
| Light Source | LED |
| Brand | Raykol |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JP500 |
| Application Form Factor | Handheld / Portable |
| Industry Use | General-Purpose |
| Elemental Range | Al to U |
| Quantification Range | 0.03 ppm – 100% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Relative Standard Deviation (RSD) | ≤0.08% for major elements |
| Detector | High-Performance Silicon Drift Detector (SDD) |
| Brand | Raykol |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JPX500 |
| Application Form Factor | Handheld/Portable |
| Industry Use | General-Purpose |
| Elemental Range | Al to U (40+ elements) |
| Quantification Range | 0.03 ppm – 100% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability (RSD) | ≤0.08% |
| Detector | High-Performance Silicon Drift Detector (SDD) |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Kjeldahl Nitrogen Analyzer |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time Setting Range | 10–9990 s |
| Repeatability | ≤0.5% RSD |
| Sample Weight Capacity | ≤5.00 g (solid), ≤20 mL (liquid) |
| Nitrogen Recovery Rate | 99–101% |
| Power Consumption | 2000 W |
| Dimensions (L×W×H) | 500 mm × 460 mm × 710 mm |
| Sample Capacity | 40-position auto-sampler |
| Integrated Refrigeration System | Standard |
| Data Storage Capacity | Up to 1,000,000 records |
| Interface Options | USB, LAN, RS232, CAN, Wi-Fi, Ethernet, Analytical Balance, Chiller Control |