| Brand | DC-Energies |
|---|---|
| Model | RRDE High-Temperature |
| Disk Material | Glassy Carbon |
| Ring Material | Platinum |
| Disk Diameter | 5.61 mm |
| Ring Outer Diameter | 15.0 mm |
| Collection Efficiency | 37% |
| Rotation Speed Range | Up to 3000 rpm |
| Housing Material | PTFE |
| Operating Temperature | Elevated Temperature Capability (Designed for >25°C environments, compatible with thermostatted electrochemical cells) |
| Compliance | ASTM D1308, ISO 13473-2 (Electrode Geometry & Calibration Standards), GLP-Compatible Configuration |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RSL-Plus |
| Pricing | Available Upon Request |
| Brand | Ruihai Photonics (Oceanhood) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PL980 |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Spectral Resolution | ~4 nm @ 25 µm slit |
| Wavelength Accuracy | ≤3% peak-to-peak (@ 2 hrs) |
| Excitation Wavelength | 976 ± 3 nm, Linewidth < 0.2 nm |
| Laser Power Stability | ≤3% P-P (@ 2 hrs) |
| Laser Lifetime | 10,000 hrs |
| Output Power Range | 0–500 mW adjustable |
| Optical Density (OD) of Notch Filter | OD8 |
| Probe Working Distance | 7.5 mm |
| Probe Fiber Length | ~1.5 m |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 5–80% RH |
| Excitation Fiber Core | 105 µm VIS-NIR |
| Emission Collection Fiber Core | 200 µm VIS-NIR |
| Spectral Range | 1000–1700 nm |
| Brand | S.T. Japan |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EZSlicer |
| Price Range | USD 2,800 – 7,000 |
| Brand | S.T. Japan |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mini Plane |
| Price Range | USD 1,400 – 2,800 |
| Brand | S.T. Japan |
|---|---|
| Origin | Japan |
| Model | S-100R |
| Temperature Range | Ambient to 600 °C |
| Optical Modes | Reflectance and Transmission |
| Vacuum Port | Integrated (1 × 10⁻³ Torr base pressure) |
| Pressure Rating | 0.5 MPa (with BaF₂, CaF₂, ZnSe, or SiO₂ windows) |
| Cooling Interface | Standard recirculating chiller port |
| Mounting Compatibility | Standard microscope stage adapters (e.g., Nikon, Olympus, Zeiss) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | S22 |
| Price | USD 72 (FOB Shanghai) |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 340–1000 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Stray Light | ≤0.3% T |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | S3 |
| Price Range | USD 65,000–130,000 |
| Operating Principle | Filter-Based |
| Imaging Method | Filter-Based |
| Deployment Mode | Airborne |
| Image Resolution | 12 Megapixel (4000 × 3000 px) |
| Sensor Size | 6.20 × 4.65 mm |
| Pixel Pitch | 1.55 µm |
| Image Format | RAW (12-bit) + JPG (8-bit) |
| Lens Options | S3W (87° HFOV, f/3.0, 19 mm equiv.) or S3N (41° HFOV, 2× optical fixed zoom, f/3.0, 19 mm equiv.) |
| Distortion | <1% extreme low distortion (non-fisheye) |
| Focal Length | 8.25 mm |
| Ground Sampling Distance (GSD) | 2.3 cm/px at 120 m AGL |
| Capture Interval | 1.5 s (JPG), 2.75 s (RAW+JPG) |
| Trigger Interface | PWM via HDMI port |
| Storage | MicroSD (64 GB or 128 GB) |
| Weight | 50 g (body only), 76 g (with battery) |
| Dimensions | 59 × 41.5 × 36 mm (L × H × W) |
| Power Input | 5.2 V, 0.2 A (USB-powered), 5.2 V, 0.4 A (battery-powered) |
| Battery | Removable Li-ion, 1200 mAh |
| Display | 2.0″ ultra-bright color touchscreen LCD |
| Video Output | HD 1080p (HDMI micro), SD 480p (optional USB FPV cable) |
| Exposure Control | Auto, manual shutter (1/2000–60 s), ISO 50–400, exposure compensation ±2.0 in 1/3-stop increments |
| White Balance Modes | Auto, Daylight, Cloudy, Tungsten, Fluorescent, Blue, Light Blue, Red, Light Red, Custom |
| Color Profiles | Normal, B&W, Sepia, Vivid |
| Sharpness | Strong, Medium, Soft |
| Shooting Modes | Single, 3-sequence, 10-sequence |
| OSD | On/Off |
| Date Stamp | On/Off |
| Audio | On/Off |
| Quick Capture | On/Off |
| Auto Power-Off | Off, 1/3/5/10/15/30/60 min |
| LCD Sleep Timer | 1/3/5 min, Off |
| Vertical Flip | On/Off |
| Included Accessories | USB GPS receiver, battery, lens cap, USB charge cable, user manual |
| Brand | Sabio |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Model 6020 |
| Price | Upon Request |
| Measurement Principle | Pulsed UV Fluorescence (PUVF) |
| Range | 0–50 ppb to 0–20 ppm (user-selectable) |
| Detection Limit | < 0.4 ppb |
| Noise | < 0.2 ppb |
| Zero Drift | < 0.5 ppb/24 hr |
| Accuracy | < 1% Full Scale |
| Sample Flow Rate | 0.4–0.8 L/min |
| Operating Temperature | 5–40 °C |
| Power Consumption | 200 W |
| Dimensions (H×W×D) | 133 × 432 × 571.5 mm |
| Weight | 11.3 kg |
| Display | High-resolution color TFT LCD with touchscreen support |
| Communication Interfaces | Ethernet (TCP/IP), USB 2.0, RS-232/485 |
| Analog I/O | 4 configurable voltage channels (0.1 V, 1 V, 2 V, 5 V, 10 V output ranges) |
| Digital I/O | 8 standard TTL-compatible channels |
| Data Logging | Internal non-volatile memory with timestamped records |
| Compliance | EPA Reference Method EQOA-0808-191 (equivalent to EPA Method 40 CFR Part 53, Class I) |
| Software | Menu-driven embedded OS with diagnostic suite, barcode-enabled time-series visualization, Modbus RTU/TCP support |
| Environmental Compensation | Automatic temperature and barometric pressure correction |
| Brand | Sabio |
|---|---|
| Origin | USA |
| Model | Model 6050 |
| Detection Principle | Non-Dispersive Infrared (NDIR) with Gas Filter Correlation (GFC) |
| Measurement Range | 0–200 ppm (user-selectable) |
| Resolution | 0.01 ppm |
| Units | ppm, ppb |
| Display | 7-inch high-resolution color TFT LCD (touch-enabled) |
| Communication Interfaces | Ethernet (TCP/IP), USB 2.0 (front-panel & rear), RS-232/485 |
| Analog I/O | 4-channel configurable voltage/current inputs & outputs |
| Digital I/O | 8-channel opto-isolated inputs/outputs |
| Environmental Compensation | Automatic temperature and barometric pressure compensation |
| Data Logging | Internal non-volatile memory (≥30 days at 1-min intervals) |
| Compliance | Meets EPA Method 40 CFR Part 53 reference equivalent performance criteria for CO analyzers |
| Software | Embedded menu-driven firmware with diagnostic suite, barcode-enabled time-series visualization, and remote configuration via web interface |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable |
| Instrument Category | Fourier Transform |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | 0.01 cm⁻¹ |
| Scan Speed | 1 scan per 60 seconds |
| Signal-to-Noise Ratio (SNR) | 45,000:1 |
| Wavenumber Accuracy | ≤0.5 cm⁻¹ |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Instrument Type | Portable Handheld Raman Spectrometer |
| Model | AT-RS200 |
| Spectral Range | 200–3200 cm⁻¹ (Raman), 190–1100 nm (UV-Vis) |
| Spectral Resolution | ≤1 cm⁻¹ (Visible Raman), ≤2 cm⁻¹ (UV Raman) |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Repeatability | ≤±0.15 cm⁻¹ |
| Detection Modalities | Surface-Enhanced Raman Scattering (SERS), UV-Vis Absorption Spectrophotometry, Colloidal Gold Immunochromatographic Assay (CGIA) |
| Total Assay Coverage | ~600 analytes across food safety, environmental monitoring, and veterinary medicine |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Excitation Wavelength | 785 nm |
| Spectral Range | 200–3350 cm⁻¹ |
| Spectral Resolution | 4.5–10 cm⁻¹ (best ≤4.5 cm⁻¹ at 912 cm⁻¹) |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.15 cm⁻¹ |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHGGP-90A |
| Operating Principle | Pushbroom Scanning |
| Imaging Method | Dispersive (Prism-Grating Hybrid) |
| Platform | UAV-Mounted |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | ≤2 nm FWHM @ 546.1 nm |
| Spatial Resolution (IFOV) | 0.1 m at 300 m AGL |
| Image Resolution | 1000 × 1200 pixels |
| Total Field of View (TFOV) | ≥20° |
| Max Operational Altitude | 500 m AGL |
| Onboard Power | Integrated LiPo Battery with Extended Flight Duration |
| Environmental Certification | Certified by China National Environmental Monitoring Centre (CNEMC) and China Environmental Protection Industry Association (CEPIA) |
| Data Processing | End-to-end pipeline including radiometric calibration, atmospheric correction, spectral unmixing, and empirical/semi-analytical inversion algorithms for water quality parameters |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHGGP-90B |
| Operating Principle | Pushbroom Scanning |
| Imaging Method | Dispersive (Prism/Grating-based) |
| Deployment Mode | Ground-Based Fixed Tower Mount |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | ≤2 nm FWHM @ 546.1 nm |
| Total Field of View (TFOV) | ≥20° |
| Instantaneous Field of View (IFOV) | 0.08 m (at 50 m installation height, 30° tilt angle) |
| Spectral Bands | >200 channels |
| Real-Time Processing Capability | Yes |
| Water Parameter Retrieval | ≥15 parameters (e.g., TSS, Turbidity, Secchi Depth, Zn, Cu, Pb, Chlorophyll-a, COD, DO, TP, TN, NH₃-N) |
| Data Transmission | Multi-destination upload support |
| Calibration | Onboard solar tracking + electronic white-board radiometric calibration |
| Software Modes | Scanning Imaging Mode & Fixed-Point Monitoring Mode |
| Georeferencing | Manual ROI-based water body delineation |
| Data Integration | Manual lab sample import for post-acquisition spectral calibration |
| Brand | SAMA |
|---|---|
| Origin | Japan |
| Model | S-7010 |
| Instrument Type | Portable |
| Principle | Multi-channel Fourier Transform NIR |
| Wavelength Range | 700–1050 nm |
| Scan Speed | 1 s per spectrum |
| Data Sampling Interval | 3 s |
| Measurement Time | 2–3 s per sample |
| Chemometrics Software | S-7010 Software |
| Light Source | Halogen lamp (avg. lifetime: 40,000 h) |
| Detector | 16-bit ADC |
| Interface | USB 2.0 |
| Power Supply | 6 × rechargeable AA batteries |
| Operating Time | ~1 h |
| Dimensions (W×H×D) | 296 × 98 × 233 mm |
| Weight | 5.3 kg |
| Application Scope | Academic research & QC in meat science, food chemistry, and agricultural laboratories |
| Brand | Sanbei Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic |
| Model | TBF-8 |
| Pricing | Upon Request |
| Dimensions | 280 mm × 40 mm |
| Inlet/Outlet Ports | M8×1 thread, Φ3.2 mm, 1/8" NPT |
| Maximum Flow Rate | 5000 mL/min |
| Operating Temperature | Ambient (20–25°C) |
| CO₂ Residual Concentration | ≤0.1 ppm |
| H₂O Residual Concentration | ≤0.1 ppm |
| Adsorption Mechanism | Chromatographic adsorption using proprietary metal oxide-based desiccant and CO₂-selective sorbent |
| Compliance | Designed for GC carrier gas and sample stream purification per ASTM D6299, ISO 8573-1 Class 1 air quality requirements, and GLP-compliant laboratory environments |
| Brand | Sanfen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | PT-80A |
| Instrument Category | Water-and-Soil Integrated |
| Sample Tray Capacity | 80 positions |
| Injection Precision | RSD ≤ 3% |
| Trap Temperature Range | Ambient to 380 °C |
| Cooling | 250 °C → 35 °C in ≤ 90 s |
| Sample Heating (Liquid) | Ambient to 95 °C |
| Sample Chilling | Ambient only |
| Cold Trap Temperature | −40 °C to ambient (Peltier + air cooling) |
| Blowback Flow Separation | Yes |
| Foam Sensor | Integrated |
| PEEK & Silanized Stainless Steel Tubing | Yes |
| Hot Water Rinse Capability | Yes |
| GC/GC-MS Synchronization | Dual TTL outputs, 1–2 s trigger latency |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AP-0010 |
| Instrument Type | Isocratic Pump |
| Maximum Pressure | 42 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Flow Accuracy | ±0.1% |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.1 MPa |
| Drive Mechanism | Dual-Piston Series Configuration with Floating Piston Design |
| Wetted Materials | 316L Stainless Steel, Sapphire, PTFE, Ceramic |
| Tubing Connection | 1/16″ Standard Fitting |
| Display | 256×64 Dot Matrix LCD with Backlight |
| Communication Interfaces | RS232 & USB (Standard), RS485/RS422 (Optional) |
| Protocols | Sanotac Proprietary Protocol, Modbus RTU/ASCII |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions | 370 × 240 × 152 mm |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic |
| Model | AP-0013 |
| Instrument Type | Binary Pump |
| Max Pressure | 30 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Flow Accuracy | ±0.1% |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.1 MPa |
| Flow Increment | 0.001 mL/min |
| Pump Head Material | PEEK |
| Plunger Design | Floating Dual-Piston in Series |
| Communication Interfaces | RS232, USB (standard) |
| Display | 256×64 dot matrix backlit LCD |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions | 370 × 240 × 152 mm |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AP0010 |
| Instrument Type | Isocratic Pump |
| Maximum Pressure | 42 MPa |
| Flow Range | 0.001–9.999 mL/min |
| Flow Accuracy | ±0.1% |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.1 MPa |
| Pump Head Volume | 10 mL |
| Fluidic Path Materials | 316L Stainless Steel, Sapphire, PTFE, Ceramic |
| Connection Standard | 1/16" tubing ports |
| Display | 256×64 dot-matrix backlit LCD |
| Control Interface | Front-panel keypad + RS232/485/422, USB, Ethernet (Modbus RTU/ASCII, Profibus DP, Profinet), Analog I/O, Digital I/O |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions | 370 × 240 × 152 mm |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AP0013 |
| Instrument Type | Binary Pump |
| Maximum Pressure | 30 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Flow Accuracy | ±0.1% |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.1 MPa |
| Pump Head Volume | 10 mL |
| Wetted Materials | PEEK, Ruby, PTFE, Ceramic |
| Communication Interfaces | RS232, USB (standard) |
| Display | 256×64 dot matrix LCD with backlight |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions | 370 × 240 × 152 mm |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Apurifier 100 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative LC System |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Apurifier 150 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–150.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | aPurifier 50 |
| Price Range | USD $14,000–$28,000 (FOB) |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium- to Low-Pressure Preparative HPLC |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | B1000 |
| Price Range | USD 1,400–2,800 |
| Optical Design | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–700 nm |
| Wavelength Automation | Automatic |
| Spectral Bandwidth | <5 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.2% |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Biolot 100 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 20 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BioLot 50 |
| Application Level | Laboratory-scale |
| Instrument Type | Medium-to-Low Pressure Preparative HPLC |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU at 254 nm (TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Biolot200 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–200.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 10 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Model | C100 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conductivity Detector |
| Conductivity Range | 1 µS/cm – 500 mS/cm |
| Temperature Reading Range | 0–99 °C |
| Temperature Accuracy | ±1 °C |
| Flow Rate Compatibility | 0–100 mL/min |
| Tubing Connection | 1/16" OD |
| Display | 256×64 dot matrix backlit LCD |
| Control Interface | Front-panel manual control or PC-based remote control via USB/Ethernet |
| Software Compliance | FDA 21 CFR Part 11 (user authentication, audit trail, electronic signature) |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions | 370 × 240 × 95 mm |