Chemical Analysis Instruments
Filter
Showing 7321–7350 of 10703 results
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Automated Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–240 mg N |
| Steam Distillation Time Setting | 10–9990 s (adjustable in 1-s increments) |
| Repeatability | ≤0.5% RSD |
| Sample Weight Capacity | Solids ≤5.00 g |
| Nitrogen Recovery Rate | 99–101% |
| Rated Power | 2000 W |
| Dimensions (L×W×H) | 500 mm × 460 mm × 710 mm |
| Touchscreen Interface | 10-inch color LCD with bilingual (English/Chinese) UI |
| Data Storage Capacity | Up to 1,000,000 records |
| Thermal Printer | 57 mm auto-cut thermal printer |
| Safety Systems | Leakage protection, interlocked safety door with alarm, steam boiler dry-run/overtemperature/overpressure detection, sample overheating protection |
| Auto-shutdown | 60-minute idle timeout |
| Electronic Audit Trail | User-level access control (3-tier), digital signature support, timestamped operation logs compliant with GLP/GMP traceability requirements |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Kjeldahl Nitrogen Analyzer |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–240 mg N |
| Steam Distillation Time | 10–9990 s |
| Repeatability | ≤0.5% RSD |
| Sample Weight Capacity | Solids ≤5.00 g, Liquids ≤20 mL |
| Nitrogen Recovery Rate | 99–101% |
| Power Consumption | 2000 W |
| Dimensions (L×W×H) | 500 × 460 × 710 mm |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Kjeldahl Nitrogen Analyzer |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1 mg – 240 mg N |
| Steam Distillation Time Setting | 10–9990 s (adjustable) |
| Repeatability | ≤0.5% RSD |
| Sample Weight Capacity | Solids ≤5.00 g |
| Ammonia Recovery Rate | 99–101% |
| Power Consumption | 2000 W |
| Dimensions (L×W×H) | 500 mm × 460 mm × 710 mm |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RKCF-200 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 81 positions |
| Flow Cell Path Length | 1–5 cm |
| Light Source | LED |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | RKFI-100 |
| Price Range | USD 11,200 – 25,200 (based on exchange rate of ¥1 = USD 0.14) |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1050 nm |
| Sample Capacity | 42 positions / 79 cups |
| Reagent Positions | 12 |
| Flow Cell Path Lengths | 10 mm / 20 mm / 30 mm |
| Light Source | LED |
| Brand | Rayleigh |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-made) |
| Model | Elementis QQ Series |
| Instrument Type | Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Detection Principle | Inductively Coupled Plasma Ionization + Mass Separation via RF Quadrupole Filter |
| Detector | Digital/Analog Dual-Mode Electron Multiplier |
| Dynamic Range | 9–10 orders of magnitude |
| Mass Analyzer Material | Pure Molybdenum Quadrupole Rods |
| Ion Source | Self-Excited All-Solid-State RF Generator (Frequency-Matched Tuning) |
| Sample Introduction | Split-Type Torch with Auto-Alignment |
| Nebulizer Cooling | Thermoelectrically Cooled (TEC) Spray Chamber |
| Gas Control | On-line Argon Dilution System |
| Optional Oxygen Addition | Independent O₂ Combustion Module |
| Collision/Reaction Cell | Patented Hybrid Electric Field Collision/Reaction Cell (KED, CRC, and MR Mode Support) |
| Brand | Rayleigh |
|---|---|
| Origin | Beijing, China |
| Model | WQF-600N |
| Instrument Principle | Fourier Transform (FT) |
| Wavenumber Range | 3300–10000 cm⁻¹ |
| Spectral Resolution | < 4 cm⁻¹ |
| Wavenumber Accuracy | Better than half the set resolution |
| Transmittance Repeatability | ±0.5% T |
| Signal-to-Noise Ratio (S/N) | >10,000:1 (RMS, 32 scans at 4300–4400 cm⁻¹) |
| Beam Splitter | CaF₂ |
| Detector Options | DTGS (PbS, InGaAs optional) |
| Light Source | Air-cooled tungsten-halogen lamp |
| Data System | PC-based with Windows OS |
| Software | Full-featured FT-NIR acquisition, preprocessing, chemometric modeling, and spectral analysis suite compliant with ASTM E1655 and ISO 12099 |
| Brand | Rayscience |
|---|---|
| Origin | Germany |
| Model | CVP21 |
| Instrument Type | Electrochemical Capacitance–Voltage Profiling System |
| Application Domain | Semiconductor Doping Profile Characterization |
| Carrier Concentration Range | 1×10¹¹ to 1×10²¹ cm⁻³ |
| Depth Resolution | Down to ≤1 nm |
| Sample Compatibility | Wafer-scale (up to 300 mm), micro-samples, epitaxial layers, bulk crystals |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | Rayscience |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | THz |
| Spectral Range | 0.1–4.0 THz |
| Spectral Resolution | <50 GHz (after FFT) |
| Dynamic Range | >70 dB (at peak) |
| Operation Modes | Transmission or Reflection |
| Sample-to-Source Distance | 1–40 cm |
| Emitter | Photoconductive Antenna |
| Detector | ZnTe Electro-Optic Crystal |
| Control Software | LabVIEW-based GUI |
| Interface | USB 2.0 & Bluetooth |
| Dimensions | 10.5" × 6.25" × 2.75" (267 × 159 × 70 mm) |
| Weight | <4.2 lbs (1.9 kg) |
| Brand | Raytech (Baoying Technology) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | Ruiyi-5S |
| Price Range | USD 28,000–42,000 (FOB Shanghai) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | High-Frequency Induction Furnace (3.5 kW output) |
| Measurement Range | C: 0.00001–99.99 wt% |
| S | 0.00001–99.99 wt% |
| Sensitivity | 0.01 ppm |
| Accuracy | C: ±1.0 ppm or RSD ≤ 0.4% |
| S | ±1.0 ppm or RSD ≤ 0.9% (per certified reference materials) |
| Analysis Time | 20–40 s |
| Gas Flow Control | Digital Electronic Pressure Control (EPC) with multi-channel independent regulation |
| Detection Configuration | Dual-band IR/UV detection for sulfur (SO₂) |
| Optical Source | Solid-state pulsed IR source & solid-state UV LED |
| Detector | High-stability solid-state IR/UV detectors |
| Thermal Management | Individual thermostatic control per gas cell |
| Safety | Integrated HF leakage shielding |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RC-800 |
| Pricing | Upon Request |
| Instrument Type | Flow Injection Analyzer (FIA) |
| Brand | Red Sun Instrument |
|---|---|
| Model | HR-280 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Control Range | Ambient to 300.0 °C (independently adjustable per bath) |
| Temperature Accuracy | ±0.1 °C (per bath) |
| Temperature Sensor | Imported Pt100 Platinum Resistance Thermometer |
| Heating Power | 1.5 kW (rated) |
| Bath Configuration | 4 independent metal heating baths |
| Stirring Speed | 1400 rpm |
| Timing Range | 0.01 s to 99 h 59 min |
| Display | 7-inch capacitive touch LCD with Chinese menu interface |
| Data Storage | Onboard non-volatile memory |
| Compliance | GB/T 7326–2016 (Petroleum Products — Determination of Copper Strip Corrosion) |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRDZT-380 |
| Application | Wood Moisture & Insulation Resistance Testing |
| Resistance Range | 10² Ω to 10¹⁶ Ω (extendable to 10²⁰ Ω via current extrapolation) |
| Resistivity Range | up to 10²² Ω·cm |
| Voltage Accuracy | ±0.5% ±1 V |
| Measurement Speed | Fast mode — 5 readings/sec |
| Display | 4.3″ high-resolution TFT LCD |
| Interface | Banana jacks, BNC connectors |
| Compliance Reference | GB/T 10580–2003, IEC 60260, ASTM D257, ISO 3915 |
| Brand | Redback Systems |
|---|---|
| Origin | Australia |
| Model | RS10k |
| Spectral Range | 450–1030 nm |
| Resolution (R = λ/Δλ) | 17,000–10,000 |
| Wavelength Stability | <10 pm/°C |
| Wavelength Accuracy | <50 pm |
| SNR | 350:1 |
| Detector | Uncooled Sony STARVIS CMOS |
| Pixel Read Noise | <2 e⁻/pixel (rms) |
| Dark Current | <0.5 e⁻/pixel/s |
| Exposure Time | 1 ms–60 s |
| Data Acquisition Rate | Up to 10 Hz |
| Input Interface | Single-mode fiber, FC/PC |
| Dimensions (H×W×L) | 40 mm × 78 mm × 120 mm |
| Polarization Independence | Yes |
| Software | RedSolve (license-free) |
| API | Python-based RedMote SDK |
| Brand | Redback Systems |
|---|---|
| Origin | Australia |
| Model | RS40k |
| Spectral Range | 430–950 nm |
| Resolution (R = λ/Δλ) | 44,000–32,000 |
| Wavelength Stability | <5 pm/°C |
| Wavelength Accuracy | <20 pm |
| Input Interface | Single-mode fiber, FC/PC |
| Detector | Cooled sCMOS (Sony STARVIS) |
| Exposure Time | 1–20,000 ms |
| Dark Current | 0.2 e⁻/pixel/s |
| Read Noise | 1.9 e⁻/pixel (rms) |
| Data Acquisition Rate | up to 5 Hz |
| Dimensions (H×W×L) | 105 × 320 × 292 mm |
| Brand | RedMatrix |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PS-PEC008 |
| Instrument Category | Electrochemical Instrument Accessory |
| Light Source Configuration | 8-channel integrated high-power monochromatic LED array (365–980 nm + white light options) |
| Max Irradiance | 200 mW/cm² |
| LED Power per Channel | 10 W (optical output: 5.4 W) |
| Spectral Range | 365–980 nm (25 discrete bands + 5 white light CCTs) |
| Light Window Diameter | 12 mm |
| LED Lifetime | >20,000 h |
| Switching Speed | <1 ms (electronic on/off, no mechanical shutter) |
| Control Interface | USB, Bluetooth, analog TTL trigger |
| Software Integration | PSTrace v4.x (compatible with PalmSens4 potentiostat/galvanostat) |
| Compliance | Designed for GLP-compliant photoelectrochemical workflows |
| Brand | Reilap |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Explorer |
| Pricing | Available Upon Request |
| Brand | Reilap |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Novisar Apply Series |
| Price Range | USD 140,000 – 280,000 |
| Instrument Type | Triple Quadrupole |
| Application Scope | Specialized |
| Mass Range | 5–2000 amu (extendable to 5–2200 amu) |
| Sensitivity | (1) ESI+, MRM mode: 1 pg reserpine, S/N ≥ 1,200,000:1 (up to 2,000,000:1) |
| (2) ESI−, MRM mode | 1 pg chloramphenicol, S/N ≥ 1,200,000:1 (up to 2,000,000:1) |
| Resolution | 0.4–2 amu |
| Brand | RELION |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | RELION CL-MicroSpectra |
| Operating Principle | Electron Beam–Induced Cathodoluminescence Spectroscopy |
| Imaging Modality | Computerized Tomographic Spectral Mapping |
| Platform Compatibility | Ground-Based & Airborne Integration |
| Spectral Range | 200–850 nm (CL Emission), Extended to 1–10,000 µm² spatial sampling area |
| Spectral Resolution | 1–15 nm (FWHM) |
| Spatial Resolution (IFOV) | 1 nm (at optimal beam focus) |
| Field of View (TFOV) | 8 mm diameter |
| Imaging Frame Rate | 15 fps (full-frame spectral cube acquisition) |
| Vacuum Chamber | ≤0.25 Pa base pressure |
| Electron Gun | Cold Cathode, Horizontal Geometry |
| Acceleration Voltage | 0–30 kV (adjustable in 100 V increments |
| Beam Current | 0.15–1 mA continuous (5 mA peak, current-limited with thermal feedback) |
| Spot Size Control | Variable demagnification from defocused (≥5 µm) to diffraction-limited point focus (<10 nm at 25 kV) |
| Digital Interface | Real-time vacuum, HV, beam current, and operational mode display with status logging |
| Brand | RELION |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RELION EDS |
| Pricing | Upon Request |
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Model | IFFM-EA |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 325–1000 nm |
| Cuvette Path Length | 10 mm (standard, fixed) |
| Wavelength Accuracy | ≤ ±2 nm |
| Wavelength Repeatability | 1 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | < 0.1% T (at NaNO₂) |
| Dark Current Drift | 0.2% T / 3 min |
| Light Current Drift | 0.5% T / 3 min |
| Data Acquisition Rate | 1–100 samples/s |
| Gain Settings | 1×, 2×, 4×, 8×, 16× |
| Filter Cutoff Frequency | 10–100 Hz |
| Pump Speed Control | 0–99 digital steps |
| Number of Pump Channels | 10 (5 per pump) |
| Valve Configuration | 16-position auto/manual selector valve |
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | IFIS Series |
| Product Type | Flow Injection Sampler |
| Pump Speed Range | 0–99 rpm |
| Maximum Sample Throughput | >600 samples/h |
| Number of Integrated Peristaltic Pumps | Dual |
| Number of Fluid Channels | Up to 10 (5 per pump) |
| Valve Configuration | Dual 16-position auto/manual switching valves (supporting up to 8 independent fluid paths) |
| Programmable Steps | Up to 15 sequences × 10 steps each |
| Control Interface | RS-232/USB |
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-A |
| Current Range | ±250 mA |
| Potential Range | −10 V to +10 V |
| Reference Electrode Input Impedance | 10 MΩ |
| Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| CE High-Voltage Power Supply Output | 0–20 kV / 0–300 µA |
| Photodetector HV Input | −100 to −1000 V |
| Wavelength Response Range | 300–650 nm (peak @ 420 nm) |
| Dynamic Range | >5 decades |
| Amplifier Gain | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Integration Time | 0.001–10 s |
| Sampling Rate | 1–200 Hz |
| Signal Noise | ≤0.5 mV (P-P, 1× gain) |
| Amplifier Drift | <0.05% |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-E |
| Current Range | ±250 mA |
| Potential Range | −10 V to +10 V |
| Reference Electrode Input Impedance | 10 MΩ |
| Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 auto-ranging decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| Luminescence Detection Dynamic Range | >5 decades |
| Photomultiplier Tube (PMT) High Voltage | −100 V to −1000 V |
| Emission Wavelength Range | 300–650 nm (Peak Sensitivity at 420 nm) |
| PMT Spectral Responsivity | >1000 A/lm |
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MPI-EII |
| Pricing | Available Upon Request |
| Electrochemical Potential Range | −10 V to +10 V |
| Current Range | ±250 mA |
| Reference Electrode Input Impedance | 10 MΩ |
| Current Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| Luminescence Dynamic Range | >5 decades |
| Photometric Accuracy | <0.05% |
| Gain Settings | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Amplifier Drift | <0.05% |
| Peak-to-Peak Noise | ≤0.5 mV (1× gain) |
| Input Impedance (Optical) | ≥10 MΩ |
| Integration Time | 0.01–10 s |
| Sampling Rate | 1–200 Hz |
| PMT High Voltage | −100 V to −1000 V |
| Spectral Range | 230–920 nm (λₚₑₐₖ = 630 nm) |
| Anode Sensitivity | >2000 A/lm |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | RFL-II |
| Detector Type | Electrochemical Luminescence Analyzer with Integrated Spectral Photomultiplier Module |
| High-Voltage Power Supply | −100 V to −1000 V (stability ±0.05%, output current ≥5 mA) |
| Gain Settings | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Signal Noise | ≤0.5 mV<sub>P-P</sub> (at 1× gain) |
| Input Impedance | ≥10 MΩ |
| Integration Time Range | 0.01–1000 s |
| Sampling Rate | 1–1000 Hz |
| Spectral Response | 230–920 nm (peak sensitivity at 630 nm) |
| Anode Sensitivity | >2000 A/lm |
| Software Functions | Real-time signal acquisition, auto-zero calibration, AGC (Automatic Gain Control), peak/area quantification, spectral export (TXT), VFD-based local parameter display |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | RPEC-A |
| Light Source | 300 W Xenon Arc Lamp |
| Spectral Range | 200–1000 nm |
| Wavelength Accuracy | ±0.25 nm |
| Wavelength Repeatability | ±0.1 nm |
| Minimum Wavelength Step | 0.01 nm |
| Spectral Bandwidth | 0.054–16.2 nm (adjustable slit: 10 µm–3 mm) |
| Electrochemical Potential Range | −10 V to +10 V |
| Current Range | ±250 mA |
| Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Scan Rate | 0.001–65 V/s |
| Reference Electrode Input Impedance | 10 MΩ |
| Operating System | Windows-based Dedicated Software |
| Brand | REMEX (Xi’an Remex) |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RPEL-B |
| Pricing | Upon Request |
| Potential Applications | Antigen/Antibody Detection, Pathogen Screening (e.g., Influenza A, HIV, Plague), Small-Molecule Biomarker Analysis (Hormones, Toxins, Glucose, Amino Acids) |
| Operating Modes | Standalone & PC-Connected (USB) |
| Electrode Format | Disposable Screen-Printed Electrodes (WE: Pt, CE: Pt, RE: Ag/AgCl or user-specified) |
| Dimensions | 140 × 110 × 110 mm (L×W×H) |
| Weight | <0.8 kg |
| Battery Life | >10 h continuous operation |
| Data Storage | Up to 1000 assay records |
| Optical Detection Range | 230–920 nm |
| Electrochemical Range | Potential: −3 V to +3 V |
| Current | ±50 mA |
| Scan Rate | 0.001–200 V/s |
| Sampling Rate | 1–200 points/s |
| Dynamic Range | >5 decades |
| Measurement Accuracy | <0.05% FS |
| Interfaces | USB 2.0 (PC control/data transfer), DB9 RS-232 (mini-printer output) |
| Integrated Magnetic Separation Module | Yes |
| Sample Volume | 5–10 µL per test |
| Compatible Substrates | Paper-based chips, ceramic chips, custom solid-phase electrochemiluminescent platforms |
| Brand | REMEX (Xi’an Remex Analytical Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RPSE-A |
| Pricing | Upon Request |
| Electrochemical Potential Range | −10 V to +10 V |
| Current Range | ±250 mA |
| Reference Electrode Input Impedance | ≥10 MΩ |
| Current Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| Wavelength Range (Monochromator) | 300–800 nm (standard), optional 200–800 nm |
| Spectral Resolution | 4.32 nm (adjustable via slit pairs: 0.4–7.2 nm, slit widths 0.05–1.0 mm) |
| Wavelength Accuracy | ±0.2% |
| Wavelength Repeatability | ±0.15% |
| Monochromator Scan Speed | 50 nm/s (standard), 100 nm/s (high-speed) |
| Exit Slit Width | 600 µm |
| Scan Modes | Time-based, fixed-point, range-scan, cyclic scan |
| Photodetector Wavelength Range | 230–700 nm |
| Peak Sensitivity Wavelength | 420 nm |
| Detection Method | Single-Photon Counting |
| Integration Times | 1 ms to 3600 s (12 selectable steps) |
| Brand | IVEA |
|---|---|
| Origin | France |
| Instrument Type | Online LIBS System |
| Laser Source | Pulsed Nd:YAG (266 nm / 355 nm / 532 nm options) |
| Operating Distance | 3–10 m (customizable) |
| Probe Options | FarLIBS (telescopic coupling) or OfiLIBS (fiber-optic coupling) |
| Optical Architecture | Integrated collimation, focusing, and light collection path |
| Spectrometer Options | Echelle spectrometer + ICCD or Czerny-Turner spectrometer + ICCD |
| Motion Control | Motorized XYZ sample positioning stage |
| Integration | Modular, field-deployable design |
| Compliance | Designed for industrial process monitoring and hazardous environment deployment |