Chemical Analysis Instruments
Filter
Showing 7441–7470 of 10689 results
| Brand | Rocktek |
|---|---|
| Model | RTK-SGMC |
| Origin | Hubei, China |
| Measurement Principle | Infrared Bubble Volume Detection |
| Flow Range | 30 µL/h – 2 L/h |
| Minimum Detectable Volume | 30 µL |
| Accuracy | <1% FS |
| Sampling Frequency | Up to 1 Hz (1 sample/sec) |
| Operating Pressure Threshold | <300 Pa |
| Temperature & Pressure Compensation | Yes (converted to STP: 0 °C, 101.325 kPa) |
| Multi-Channel Capability | Up to 9 channels via single software instance |
| Gas Compatibility | All gases including corrosive species (e.g., H₂S, NH₃, Cl₂, HCl) and mixed gas streams |
| Output Interfaces | Digital (RS485/USB) and Analog (4–20 mA or 0–5 V) |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | RoHS II |
| Pricing | Available Upon Request |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LR |
| Pricing | Available Upon Request |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | RollScan 300 |
| Price | Upon Request |
| Power Supply | 90–260 VAC, 49–61 Hz, Single-Phase |
| Inrush Current (Cold Start) | 40 A @ 115 VAC, 80 A @ 230 VAC |
| Power Consumption (Charging Battery) | 150 VA |
| Typical Operating Power | 100 VA |
| Magnetization Frequency Range | 1.0–1000 Hz |
| Magnetization Voltage Range | 0–16 V |
| Signal Analysis Filter Bands | 10–70 kHz, 70–200 kHz, 200–450 kHz |
| Channel Configuration | Single-Channel Standard (Multi-Channel Optional) |
| Sensor Interface | Detachable Pre-Amplified Probes |
| Compatible Materials | Ferritic steels, iron-based alloys, nickel-based superalloys, cobalt-based alloys |
| Signal Processing | Real-Time Digital Signal Processor (DSP) |
| Brand | ROOKO |
|---|---|
| Model | LX-9830GA |
| Type | Benchtop Voltage Drop Analyzer |
| Measurement Parameters | Contact Resistance, Voltage Drop, Current, Open-Circuit Voltage, Temperature |
| Current Range | 0–300 A (selectable ranges: 0–40 A / 0–60 A / 0–100 A / 0–200 A / 0–300 A) |
| Voltage Range (open-circuit) | 0–12 V / 0–24 V / 0–30 V (optional) |
| Voltage Drop Range | 0–199.99 mV |
| Resolution | 0.01 mV (voltage drop), 0.01 A (current), 0.01 V (voltage) |
| Accuracy | ±1% of reading |
| Test Time Setting | 0.01 s – 99.99 h |
| Temperature Measurement Range | 0–25 °C (integrated sensor) |
| Compliance Standards | QC/T 29106–2004, QC/T 730–2005, ISO 6722:2002, GB/T 2951–1997, GB/T 3048–1994, QC/T 413–2002, SAE USCAR-38:2009 |
| Interface Options | RS-232, USB 2.0 |
| Data Management | Password-protected instrument configuration, pass/fail counting (0–99999), audible/visual alarm on limit violation |
| External Integration | PLC control interface, PC software (optional), printer support, custom fixture compatibility |
| Brand | Tlyon (Distributor) |
|---|---|
| Origin | Hungary |
| Manufacturer | RotaChrom GmbH |
| Instrument Type | Benchtop Centrifugal Partition Chromatograph |
| Software Components | CPC Simulator, CPC Visualizer |
| Flow Rate Range | 0.1–25 mL/min |
| Sample Load Capacity | 10 mg–5 g per cycle |
| Detection | UV-Vis (200–600 nm), optional ELSD/MS interface |
| Fraction Collection | Automated, timed or peak-triggered |
| Compliance | GLP-ready architecture, audit trail-capable software logging, ISO/IEC 17025-aligned operation |
| Brand | dc-energies |
|---|---|
| Diameter | 5 mm (active disk) |
| Overall Outer Diameter | 15 mm |
| Material | High-purity glassy carbon disk, PTFE-insulated shaft, stainless steel or brass housing (configurable) |
| Origin | Hubei, China |
| Instrument Type | Electrochemical Working Electrode Accessory |
| Brand | dc-energies |
|---|---|
| Material Options | Glassy Carbon (GC), Gold (Au), Platinum (Pt) |
| Disk Diameter | 5.0 mm |
| Overall Electrode Outer Diameter | 15 mm |
| Operating Temperature Range | 10–25 °C |
| Brand | dc-energies |
|---|---|
| Disk Diameter | 5.61 mm |
| Ring Outer Diameter | 15.0 mm |
| Material | Glassy Carbon Disk / Platinum Ring |
| Insulator | PTFE Shroud |
| Max Rotation Speed | 3000 rpm |
| Collection Efficiency | 37% |
| Operating Temperature | ≤25 °C |
| Origin | Hubei, China |
| Instrument Type | Electrochemical Working Electrode |
| Origin | Switzerland |
|---|---|
| Type | Portable Dew Point Meter |
| Model | DP70 |
| Sensor Platform | HygroClip 2 with AirChip3000 IC |
| Accuracy | ±0.8 %RH (10–30 °C), ±0.1 °C temperature, ±2 °C dew point (at −40 °C Td) |
| Dew Point Range | −60 to +60 °C (extended: −40 to +85 °C) |
| Pressure Rating | 20 bar |
| Calibration | Onboard probe-stored calibration data, traceable to SCS-certified humidity standards |
| Compliance | Meets requirements for ISO/IEC 17025-compliant calibration workflows, supports GLP/GMP audit trails |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | ROXY™ EC |
| Application | Online Electrochemical Cell for LC-MS Coupling |
| Compatibility | Universal MS Interface (Agilent, Thermo Fisher, Waters, SCIEX, Shimadzu) |
| Configuration | Flow-through electrochemical flow cell with integrated electrode cartridge and MS-compatible solvent handling |
| Regulatory Context | Designed for GLP-compliant metabolic stability screening and oxidative stress simulation studies |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ROXY |
| Pricing | Available Upon Request |
| Potentiostat | ROXY Potentiostats DCC |
| Autosampler | AS 110 (Cool, Micro, 10-Position Vial) |
| LC Pump | LC 110 |
| Reactor Cell | Integrated with Multi-Electrode Detection (MD) and Gas Collection (GC) Electrodes |
| Organizer | OR 110 |
| Software | Clarity Chromatography Data System |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | RP-92 |
| Pricing | Upon Request |
| Instrument Type | Online/Field-Deployable |
| Analytical Principle | Cold Vapor Atomic Fluorescence Spectrometry (CV-AFS) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RQflex 20 |
| Price | Upon Request |
| Brand | DC-Energies |
|---|---|
| Model | RRDE High-Temperature |
| Disk Material | Glassy Carbon |
| Ring Material | Platinum |
| Disk Diameter | 5.61 mm |
| Ring Outer Diameter | 15.0 mm |
| Collection Efficiency | 37% |
| Rotation Speed Range | Up to 3000 rpm |
| Housing Material | PTFE |
| Operating Temperature | Elevated Temperature Capability (Designed for >25°C environments, compatible with thermostatted electrochemical cells) |
| Compliance | ASTM D1308, ISO 13473-2 (Electrode Geometry & Calibration Standards), GLP-Compatible Configuration |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RSL-Plus |
| Pricing | Available Upon Request |
| Brand | Ruihai Photonics (Oceanhood) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PL980 |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Spectral Resolution | ~4 nm @ 25 µm slit |
| Wavelength Accuracy | ≤3% peak-to-peak (@ 2 hrs) |
| Excitation Wavelength | 976 ± 3 nm, Linewidth < 0.2 nm |
| Laser Power Stability | ≤3% P-P (@ 2 hrs) |
| Laser Lifetime | 10,000 hrs |
| Output Power Range | 0–500 mW adjustable |
| Optical Density (OD) of Notch Filter | OD8 |
| Probe Working Distance | 7.5 mm |
| Probe Fiber Length | ~1.5 m |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 5–80% RH |
| Excitation Fiber Core | 105 µm VIS-NIR |
| Emission Collection Fiber Core | 200 µm VIS-NIR |
| Spectral Range | 1000–1700 nm |
| Brand | S.T. Japan |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EZSlicer |
| Price Range | USD 2,800 – 7,000 |
| Brand | S.T. Japan |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mini Plane |
| Price Range | USD 1,400 – 2,800 |
| Brand | S.T. Japan |
|---|---|
| Origin | Japan |
| Model | S-100R |
| Temperature Range | Ambient to 600 °C |
| Optical Modes | Reflectance and Transmission |
| Vacuum Port | Integrated (1 × 10⁻³ Torr base pressure) |
| Pressure Rating | 0.5 MPa (with BaF₂, CaF₂, ZnSe, or SiO₂ windows) |
| Cooling Interface | Standard recirculating chiller port |
| Mounting Compatibility | Standard microscope stage adapters (e.g., Nikon, Olympus, Zeiss) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | S22 |
| Price | USD 72 (FOB Shanghai) |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 340–1000 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Stray Light | ≤0.3% T |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | S3 |
| Price Range | USD 65,000–130,000 |
| Operating Principle | Filter-Based |
| Imaging Method | Filter-Based |
| Deployment Mode | Airborne |
| Image Resolution | 12 Megapixel (4000 × 3000 px) |
| Sensor Size | 6.20 × 4.65 mm |
| Pixel Pitch | 1.55 µm |
| Image Format | RAW (12-bit) + JPG (8-bit) |
| Lens Options | S3W (87° HFOV, f/3.0, 19 mm equiv.) or S3N (41° HFOV, 2× optical fixed zoom, f/3.0, 19 mm equiv.) |
| Distortion | <1% extreme low distortion (non-fisheye) |
| Focal Length | 8.25 mm |
| Ground Sampling Distance (GSD) | 2.3 cm/px at 120 m AGL |
| Capture Interval | 1.5 s (JPG), 2.75 s (RAW+JPG) |
| Trigger Interface | PWM via HDMI port |
| Storage | MicroSD (64 GB or 128 GB) |
| Weight | 50 g (body only), 76 g (with battery) |
| Dimensions | 59 × 41.5 × 36 mm (L × H × W) |
| Power Input | 5.2 V, 0.2 A (USB-powered), 5.2 V, 0.4 A (battery-powered) |
| Battery | Removable Li-ion, 1200 mAh |
| Display | 2.0″ ultra-bright color touchscreen LCD |
| Video Output | HD 1080p (HDMI micro), SD 480p (optional USB FPV cable) |
| Exposure Control | Auto, manual shutter (1/2000–60 s), ISO 50–400, exposure compensation ±2.0 in 1/3-stop increments |
| White Balance Modes | Auto, Daylight, Cloudy, Tungsten, Fluorescent, Blue, Light Blue, Red, Light Red, Custom |
| Color Profiles | Normal, B&W, Sepia, Vivid |
| Sharpness | Strong, Medium, Soft |
| Shooting Modes | Single, 3-sequence, 10-sequence |
| OSD | On/Off |
| Date Stamp | On/Off |
| Audio | On/Off |
| Quick Capture | On/Off |
| Auto Power-Off | Off, 1/3/5/10/15/30/60 min |
| LCD Sleep Timer | 1/3/5 min, Off |
| Vertical Flip | On/Off |
| Included Accessories | USB GPS receiver, battery, lens cap, USB charge cable, user manual |
| Brand | Sabio |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Model 6020 |
| Price | Upon Request |
| Measurement Principle | Pulsed UV Fluorescence (PUVF) |
| Range | 0–50 ppb to 0–20 ppm (user-selectable) |
| Detection Limit | < 0.4 ppb |
| Noise | < 0.2 ppb |
| Zero Drift | < 0.5 ppb/24 hr |
| Accuracy | < 1% Full Scale |
| Sample Flow Rate | 0.4–0.8 L/min |
| Operating Temperature | 5–40 °C |
| Power Consumption | 200 W |
| Dimensions (H×W×D) | 133 × 432 × 571.5 mm |
| Weight | 11.3 kg |
| Display | High-resolution color TFT LCD with touchscreen support |
| Communication Interfaces | Ethernet (TCP/IP), USB 2.0, RS-232/485 |
| Analog I/O | 4 configurable voltage channels (0.1 V, 1 V, 2 V, 5 V, 10 V output ranges) |
| Digital I/O | 8 standard TTL-compatible channels |
| Data Logging | Internal non-volatile memory with timestamped records |
| Compliance | EPA Reference Method EQOA-0808-191 (equivalent to EPA Method 40 CFR Part 53, Class I) |
| Software | Menu-driven embedded OS with diagnostic suite, barcode-enabled time-series visualization, Modbus RTU/TCP support |
| Environmental Compensation | Automatic temperature and barometric pressure correction |
| Brand | Sabio |
|---|---|
| Origin | USA |
| Model | Model 6050 |
| Detection Principle | Non-Dispersive Infrared (NDIR) with Gas Filter Correlation (GFC) |
| Measurement Range | 0–200 ppm (user-selectable) |
| Resolution | 0.01 ppm |
| Units | ppm, ppb |
| Display | 7-inch high-resolution color TFT LCD (touch-enabled) |
| Communication Interfaces | Ethernet (TCP/IP), USB 2.0 (front-panel & rear), RS-232/485 |
| Analog I/O | 4-channel configurable voltage/current inputs & outputs |
| Digital I/O | 8-channel opto-isolated inputs/outputs |
| Environmental Compensation | Automatic temperature and barometric pressure compensation |
| Data Logging | Internal non-volatile memory (≥30 days at 1-min intervals) |
| Compliance | Meets EPA Method 40 CFR Part 53 reference equivalent performance criteria for CO analyzers |
| Software | Embedded menu-driven firmware with diagnostic suite, barcode-enabled time-series visualization, and remote configuration via web interface |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable |
| Instrument Category | Fourier Transform |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | 0.01 cm⁻¹ |
| Scan Speed | 1 scan per 60 seconds |
| Signal-to-Noise Ratio (SNR) | 45,000:1 |
| Wavenumber Accuracy | ≤0.5 cm⁻¹ |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Instrument Type | Portable Handheld Raman Spectrometer |
| Model | AT-RS200 |
| Spectral Range | 200–3200 cm⁻¹ (Raman), 190–1100 nm (UV-Vis) |
| Spectral Resolution | ≤1 cm⁻¹ (Visible Raman), ≤2 cm⁻¹ (UV Raman) |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Repeatability | ≤±0.15 cm⁻¹ |
| Detection Modalities | Surface-Enhanced Raman Scattering (SERS), UV-Vis Absorption Spectrophotometry, Colloidal Gold Immunochromatographic Assay (CGIA) |
| Total Assay Coverage | ~600 analytes across food safety, environmental monitoring, and veterinary medicine |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Excitation Wavelength | 785 nm |
| Spectral Range | 200–3350 cm⁻¹ |
| Spectral Resolution | 4.5–10 cm⁻¹ (best ≤4.5 cm⁻¹ at 912 cm⁻¹) |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.15 cm⁻¹ |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHGGP-90A |
| Operating Principle | Pushbroom Scanning |
| Imaging Method | Dispersive (Prism-Grating Hybrid) |
| Platform | UAV-Mounted |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | ≤2 nm FWHM @ 546.1 nm |
| Spatial Resolution (IFOV) | 0.1 m at 300 m AGL |
| Image Resolution | 1000 × 1200 pixels |
| Total Field of View (TFOV) | ≥20° |
| Max Operational Altitude | 500 m AGL |
| Onboard Power | Integrated LiPo Battery with Extended Flight Duration |
| Environmental Certification | Certified by China National Environmental Monitoring Centre (CNEMC) and China Environmental Protection Industry Association (CEPIA) |
| Data Processing | End-to-end pipeline including radiometric calibration, atmospheric correction, spectral unmixing, and empirical/semi-analytical inversion algorithms for water quality parameters |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHGGP-90B |
| Operating Principle | Pushbroom Scanning |
| Imaging Method | Dispersive (Prism/Grating-based) |
| Deployment Mode | Ground-Based Fixed Tower Mount |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | ≤2 nm FWHM @ 546.1 nm |
| Total Field of View (TFOV) | ≥20° |
| Instantaneous Field of View (IFOV) | 0.08 m (at 50 m installation height, 30° tilt angle) |
| Spectral Bands | >200 channels |
| Real-Time Processing Capability | Yes |
| Water Parameter Retrieval | ≥15 parameters (e.g., TSS, Turbidity, Secchi Depth, Zn, Cu, Pb, Chlorophyll-a, COD, DO, TP, TN, NH₃-N) |
| Data Transmission | Multi-destination upload support |
| Calibration | Onboard solar tracking + electronic white-board radiometric calibration |
| Software Modes | Scanning Imaging Mode & Fixed-Point Monitoring Mode |
| Georeferencing | Manual ROI-based water body delineation |
| Data Integration | Manual lab sample import for post-acquisition spectral calibration |
| Brand | SAMA |
|---|---|
| Origin | Japan |
| Model | S-7010 |
| Instrument Type | Portable |
| Principle | Multi-channel Fourier Transform NIR |
| Wavelength Range | 700–1050 nm |
| Scan Speed | 1 s per spectrum |
| Data Sampling Interval | 3 s |
| Measurement Time | 2–3 s per sample |
| Chemometrics Software | S-7010 Software |
| Light Source | Halogen lamp (avg. lifetime: 40,000 h) |
| Detector | 16-bit ADC |
| Interface | USB 2.0 |
| Power Supply | 6 × rechargeable AA batteries |
| Operating Time | ~1 h |
| Dimensions (W×H×D) | 296 × 98 × 233 mm |
| Weight | 5.3 kg |
| Application Scope | Academic research & QC in meat science, food chemistry, and agricultural laboratories |