| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | FS-100 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–10.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | FS-50 |
| Price Range | USD 14,000 – 28,000 (FOB Shanghai) |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 30 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | Grad600 |
| Price Range | USD 14,000 – 28,500 |
| Application Tier | Industrial-Scale Preparative |
| Instrument Class | Medium-to-Low Pressure Preparative LC System |
| Flow Rate Range | 0.01–600.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU @ 254 nm, TC = 1 s |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HPLC-10C18E |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure Rating | 10 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.5×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HPLC-5C18E |
| Application Level | Laboratory-Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Model | HT-100 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Class | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Pump Material | 316L Stainless Steel (PEEK optional) |
| UV Detector | Dual-lamp (Deuterium + Tungsten), Dual-wavelength simultaneous detection |
| Fraction Collector | Auto-collector with 2×60 tube rack (Φ15 mm × 150 mm) |
| Collection Modes | Time-based, peak-triggered, threshold-triggered, sequential, cyclic |
| Injection Valve | Manual preparative valve (standard 10 mL loop) |
| Sample Introduction | Solid or liquid loading |
| Gradient Types | Step, linear, real-time modifiable |
| Minimum Gradient Increment | 1% |
| Software Compliance | CFDA GxP & FDA 21 CFR Part 11 compliant Sanochrom™ workstation (Windows 7/8/10) |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | HT-50 |
| Price Range | USD 14,000 – 28,000 (FOB Shanghai) |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 30 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Producer |
| Instrument Type | Isocratic Pump |
| Max Pressure | 40 MPa |
| Flow Rate Range | 0.0001–1 mL/min |
| Flow Accuracy | ±0.1% |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.1 MPa |
| Priming Mode | Dual-Piston Serial Drive with Floating Piston Design |
| Wetted Materials | 316L Stainless Steel, Sapphire, PTFE, Ceramic |
| Connection | 1/16″ Standard Fitting |
| Display | 256×64 Dot Matrix Backlit LCD |
| Communication | RS232 & USB (Standard), RS485/RS422 (Optional), Sanotac Proprietary & Modbus RTU Protocols |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions | 370 × 240 × 152 mm |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | K6000 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | Semiconductor Laser |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | KAP0010 |
| Instrument Type | Binary High-Pressure Solvent Delivery Pump |
| Maximum Pressure | 42 MPa |
| Flow Rate Range | 0.001–10 mL/min (standard configuration with 10 mL pump head) |
| Pump Head Material Options | Stainless Steel, Titanium, PTFE, PCTFE, Hastelloy C-276, PEEK |
| Control Interface | RS-232/RS-485, Open Protocol for External Workstation Integration |
| Gradient Capability | Isocratic, Linear, Step, and Custom Composite Gradients |
| Flow Accuracy | ≤ ±0.1% RSD at ≥1 mL/min |
| Pressure Ripple | < 0.1% (measured at 1 mL/min, 10 MPa, methanol/water 80:20) |
| Seal Life | Enhanced via Floating Plunger Design & Precision Cam Drive |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | L6000 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | Semiconductor Laser |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Max Pressure | 42 MPa |
| Flow Accuracy | ±1% |
| Flow Precision | ±0.5% |
| Injection Volume Options | 2 mL (108-position) or 4 mL (70-position) |
| Column Oven Temperature Range | Ambient +5 °C to 80 °C |
| Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LC2200 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Profile | Dedicated-Use Analytical Instrument |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Maximum Operating Pressure | 42 MPa |
| Detector Wavelength Range | 190–700 nm (D₂ + W lamp) |
| Baseline Noise | ≤1×10⁻⁵ AU |
| Baseline Drift | ≤1.5×10⁻⁴ AU/hr |
| Flow Accuracy | ≤±1% |
| Flow Precision | ±0.5% |
| Flow RSD | ≤0.1% |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Detection Range | 0–3 AU |
| Flow Cell Volume | 10 µL |
| Time Constant | 16-step adjustable |
| Auto-Zero | Full-scale |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ELSD 7000 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | Semiconductor Laser |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ELSD-2000 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | Semiconductor Laser Diode |
| Baseline Noise | ≤ 0.04 mV |
| Baseline Drift | ≤ 0.4 mV / 30 min |
| Minimum Detectable Mass | < 1 ng |
| Quantitative Range | 0.1 µg – 30 µg |
| Quantitative RSD | ≤ 2% |
| Evaporator Temp Range | Ambient to 130 °C (1 °C increments) |
| Nebulizer Temp Range | Ambient to 56 °C (1 °C increments) |
| Temperature Accuracy | ±1 °C |
| Carrier Gas | Clean Air or Nitrogen |
| Gas Pressure Range | 2–5 bar |
| Gas Pressure Resolution | 0.01 bar |
| Gas Flow Rate | 1–4 L/min |
| Flow Control Accuracy | ≤1% or 0.02 L/min |
| Mobile Phase Flow Compatibility | 0.01–3 mL/min |
| Analog Output | −1200 to +1200 mV |
| Gain Adjustment | 0.3–30 (continuous) |
| Data Acquisition Rate | 100 Hz (digital), 20 Hz (analog) |
| Interface | RS-232, RS-485, USB/LAN (TCP/HTTP), Programmable External Event I/O |
| Dimensions (W×H×D) | 26 × 19 × 46 cm |
| Weight | 10 kg |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ELSD-3300 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | Semiconductor Laser Diode |
| Brand | Sanotac |
|---|---|
| Model | Omnitor ELSD |
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Evaporative Light Scattering Detector |
| Wavelength | 650 nm semiconductor laser |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | 650 nm semiconductor laser diode |
| Dimensions | 26 × 19 × 46 cm |
| Weight | 10 kg |
| Power Supply | 85–264 VAC, 50 Hz |
| Evaporator Temperature Range | Ambient to 130 °C (1 °C increment) |
| Nebulizer Temperature Range | Ambient to 56 °C (1 °C increment) |
| Temperature Control Accuracy | ±1 °C |
| Carrier Gas | Clean compressed air or nitrogen |
| Gas Pressure Range | 2–5 bar (0.01 bar resolution) |
| Gas Flow Rate | 1–4 L/min (accuracy ≤1% or ±0.02 L/min) |
| Mobile Phase Flow Rate Compatibility | 0.01–3 mL/min |
| Baseline Noise | ≤0.03 mV |
| Baseline Drift | ≤0.3 mV / 30 min |
| Minimum Detectable Mass | <1 ng (e.g., cholesterol in methanol) |
| Quantitative Range | 0.1 µg–30 µg |
| Quantitative Repeatability (RSD₆) | ≤1.5% |
| Dynamic Range | 10⁴ (at fixed gain) |
| Analog Output Range | –1200 to +1200 mV |
| Gain Adjustment | Continuous, 0.3–30× |
| Output Offset | –1000 to +1000 mV |
| Sampling Rate | 100 Hz (digital), 20 Hz (analog) |
| Data Interfaces | RS-232, RS-485, USB, LAN (TCP/HTTP), programmable external event I/O |
| Software Compliance | FDA 21 CFR Part 11–compliant chromatography data system with audit trail |
| Method Storage | 10 methods × 25 parameters |
| Power Consumption | Low-power standby mode reduces nitrogen consumption by >50% |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omnitor |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | Semiconductor Laser |
| Brand | Sanotac |
|---|---|
| Model | Pilot Series |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min (gradient) |
| Max. Operating Pressure | 30 MPa |
| Injection Volume | 1–20 mL |
| Column Temperature Control | 0–80 °C |
| UV Detection Wavelength Range | 190–800 nm (dual-wavelength simultaneous detection) |
| Data Acquisition Frequency | 10 Hz |
| Detector Wavelength Accuracy | ±1 nm |
| Absorbance Range | 0–2 AU |
| Gradient Types | Step, Linear, Real-time Adjustable |
| Flow Accuracy | ±0.5% |
| Pressure Pulsation | ≤0.2 MPa |
| Pump Material Options | 316L Stainless Steel, PEEK, Titanium, Hastelloy |
| Fraction Collector | Auto, 2 × 60 positions (Φ15 mm × 150 mm tubes), multiple collection modes |
| Software Compliance | Fully compliant with CFDA GxP and FDA 21 CFR Part 11 (audit trail, electronic signature, role-based access control, database-driven project management) |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Pilot |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Pilot-1000 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative HPLC |
| Flow Rate Range | 0.01–1000.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Pilot-300 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–300.00 mL/min |
| Maximum Pressure | 15 MPa |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Pressure Pulsation | ≤0.5 MPa |
| Wavelength Range (UV-Vis Detector) | 190–700 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Flow Cell Path Length | Adjustable (1–5 mm) |
| Baseline Noise | ±0.5×10⁻⁵ AU (254 nm, TC=1 s) |
| Baseline Drift | 1.5×10⁻⁴ AU (254 nm) |
| Linear Range | ≥3 AU |
| Time Constant Options | 0.1/0.2/0.5/1.0/2.0/5.0/10.0 s |
| Detection Modes | Dual-Wavelength Monitoring, Wavelength-Time Programming, Stop-Flow Scanning |
| Gradient & Flow Programming | 10 User-Defined Methods |
| Column ID Compatibility | 10–30 mm I.D. |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Pilot-50 |
| Price Range | USD 14,000 – 28,000 (FOB Shanghai) |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 30 MPa |
| Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Pilot-600 |
| Price Range | USD 14,000 – 28,000 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative HPLC |
| Flow Rate Range | 0.01–600.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU at 254 nm, TC = 1 s |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Pilot100 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 30 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Pilot1000 |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Static Axial Compression System |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | Pilot200 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–200.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 10 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Pilot50 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Pressure | 30 MPa |
| Wavelength Range | 190–700 nm |
| Wavelength Repeatability | ±0.2 nm |
| Detection Modes | Dual-Wavelength UV, Time-Programmed Wavelength, Stop-Flow Scanning |
| Gradient Programming | 10 User-Defined Methods |
| Column ID Compatibility | 10–30 mm |
| Detector Cell Pathlength | Adjustable (1–5 mm) |
| Baseline Noise | ±0.5×10⁻⁵ AU (254 nm, TC=1 s) |
| Baseline Drift | 1.5×10⁻⁴ AU (254 nm, 1 h) |
| Time Constant Options | 0.1/0.2/0.5/1.0/2.0/5.0/10.0 s |
| Digital Zero Adjustment | Full-Scale Auto-Zero |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Pilot600 |
| Instrument Type | Dynamic Axial Compression (DAC) System |
| Pump Material | 316L Stainless Steel (PEEK optional) |
| Flow Rate Range | 0.01–600.00 mL/min (gradient mode) |
| Flow Accuracy | ±0.5% |
| Maximum Pressure | 10 MPa |
| Pressure Pulsation | ≤0.2 MPa |
| Gradient Types | Step, Linear, Real-time Adjustable |
| Minimum Gradient Increment | 1% |
| Detection Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | 0–2 AU |
| UV-Vis Light Source | Imported Deuterium + Tungsten Lamps |
| Sample Injection | Manual 10 mL loop (customizable loops available) |
| Injection Modes | Solid or Liquid Loading |
| Power Supply | 220 V ±10%, 50 Hz |
| Control Interface | Graphical UI via USB/RS-232 |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Purifier 100 |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |