| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Apurifier 150 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–150.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | aPurifier 50 |
| Price Range | USD $14,000–$28,000 (FOB) |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium- to Low-Pressure Preparative HPLC |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | B1000 |
| Price Range | USD 1,400–2,800 |
| Optical Design | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–700 nm |
| Wavelength Automation | Automatic |
| Spectral Bandwidth | <5 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.2% |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Biolot 100 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 20 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BioLot 50 |
| Application Level | Laboratory-scale |
| Instrument Type | Medium-to-Low Pressure Preparative HPLC |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU at 254 nm (TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Biolot200 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–200.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 10 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Model | C100 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conductivity Detector |
| Conductivity Range | 1 µS/cm – 500 mS/cm |
| Temperature Reading Range | 0–99 °C |
| Temperature Accuracy | ±1 °C |
| Flow Rate Compatibility | 0–100 mL/min |
| Tubing Connection | 1/16" OD |
| Display | 256×64 dot matrix backlit LCD |
| Control Interface | Front-panel manual control or PC-based remote control via USB/Ethernet |
| Software Compliance | FDA 21 CFR Part 11 (user authentication, audit trail, electronic signature) |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions | 370 × 240 × 95 mm |
| Brand | Sanotac |
|---|---|
| Model | C1000 |
| Application | In-line conductivity detection for chromatographic protein purification |
| Conductivity Range | 1 µS/cm to 500 mS/cm |
| Temperature Range | 0–99 °C |
| Temperature Accuracy | ±1 °C |
| Conductivity Accuracy | ±2% FS |
| Flow Rate Compatibility | 100–1000 mL/min |
| Tubing Connection | 1/8" (3.2 mm) compression fitting |
| Display | 256×64 dot-matrix backlit LCD |
| Control Interface | Front-panel keypad + PC-based software with remote control capability |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions (W×D×H) | 370 × 240 × 95 mm |
| Compliance | FDA 21 CFR Part 11 (audit trail, electronic signature, role-based user access), GLP/GMP-ready architecture |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | CS100 |
| Price Range | USD $14,000 – $28,000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0.01–10.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU at 254 nm, TC = 1 s |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | CS2501 |
| Price Range | USD 14,000–28,000 (FOB) |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.1–100.00 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 5 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU at 254 nm, TC = 1 s |
| Data Acquisition Rate | 10 Hz |
| Gradient Types | Step, Linear, Real-Time Adjustable |
| Detector Light Source | Dual Lamp (Deuterium + Tungsten, Imported) |
| UV/Vis Detection Modes | Dual-Wavelength Simultaneous Detection, Time-Programmed Wavelength, Stop-Flow Scanning |
| Sample Collection | Automated Fraction Collector with 2×60 positions (Φ15 mm × 150 mm tubes), Volume/Time/Threshold/Slope-Triggered Collection, Delay Volume Compensation, Independent Waste Channel, High-Accuracy Vial Switching |
| Software Compliance | Fully compliant with CFDA GxP and FDA 21 CFR Part 11 (audit trail, electronic signature, user access control, data integrity safeguards) |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | DAC Series |
| Price | USD 7,000–85,000 (varies by configuration) |
| Application Level | Laboratory to Pilot-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.01–6,000 mL/min (model-dependent) |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 10 MPa (100 bar) |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Column ID Options | 50–300 mm |
| Max. Bed Height | 500 mm |
| Column Tube Material | 316L Stainless Steel |
| Wall Roughness (Ra) | ≤0.2 µm |
| Frit Pore Size | 2 µm |
| Frit Material | 316L Stainless Steel |
| Gradient Types | Step, Linear, Real-Time Adjustable |
| Minimum Gradient Increment | 1% |
| UV Detector Light Source | Imported Deuterium Lamp + Tungsten Lamp |
| Absorbance Range | 0–2 AU |
| Collection Modes | Time-Based, Peak-Triggered, Threshold-Triggered, Sequential, Recirculating |
| Recommended Particle Sizes | 5–10 µm |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DAC-100 |
| Application Level | Industrial Preparative Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–1000.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Column ID | 100 mm |
| Max Bed Height | 500 mm |
| Column Tube Material | 316L Stainless Steel |
| Wall Roughness (Ra) | ≤0.2 µm |
| Frit Pore Size | 2 µm |
| Frit Material | 316L Stainless Steel |
| Recommended Particle Size | 5–10 µm |
| Pump Max Flow | 600 mL/min |
| Recommended Operational Flow | 200–350 mL/min |
| Gradient Types | Step, Linear, Real-Time Modifiable |
| Minimum Gradient Increment | 1% |
| UV Detector Light Sources | Deuterium + Tungsten Lamps (Imported) |
| Absorbance Range | 0–2 AU |
| Collection Modes | Time-Based, Peak-Triggered, Threshold-Based, Sequential, Recirculating |
| System Dimensions (W×D×H) | 750 × 650 × 2360 mm |
| Net Weight | 240 kg |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DAC300 |
| Application Level | Industrial-Scale Preparation |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.01–3000.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.5×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DAC80 |
| Application Level | Industrial Preparative Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.01–1000.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.5×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ELSD 9000 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | Semiconductor Laser Diode |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) & Direct Producer |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | Semiconductor Laser Diode |
| Brand | Sanotac |
|---|---|
| Model | ELSD-6000 |
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Light Source | 650 nm semiconductor laser |
| Detection Principle | Mass-sensitive, non-destructive aerosol light scattering |
| Drift Tube Temperature Range | Ambient to 130 °C (1 °C increments) |
| Nebulizer Temperature Range | Ambient to 56 °C |
| Gas Flow Rate | 1–4 L/min (accuracy ≤1% or ±0.02 L/min) |
| Gas Pressure Range | 2–5 bar (pressure detection accuracy: 0.01 bar) |
| Mobile Phase Flow Rate Compatibility | 0.01–3 mL/min |
| Baseline Noise | ≤0.03 mV |
| Baseline Drift | ≤0.3 mV / 30 min |
| Minimum Detectable Mass | <1 ng |
| Typical Quantitation Range | 0.1–30 µg |
| Quantitative Repeatability (RSD) | ≤2% |
| Dynamic Range | 10⁴ (at fixed gain) |
| Gain Adjustment | Continuous, 0.3–30 |
| Analog Output | –1200 to +1200 mV |
| Data Acquisition Rate | 100 Hz (digital), 20 Hz (filtered) |
| Dimensions (W×H×D) | 26×19×46 cm |
| Weight | 10 kg |
| Compliance | FDA 21 CFR Part 11 (audit trail enabled in Clarity™ software) |
| Software Interface | RS-232, RS-485, USB, LAN (TCP/HTTP), programmable external event I/O |
| Brand | Sanotac |
|---|---|
| Model | ELSD-6000 |
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | HPLC-Compatible Evaporative Light Scattering Detector |
| Flow Rate Range | 0.01–3 mL/min |
| Max Operating Pressure | 1 bar |
| Sample Injection Positions | 1 |
| Injection Volume Range | 1 µL–100 µL (system-dependent) |
| Drift Tube Temperature Range | Ambient to 150 °C (1 °C increment) |
| Nebulizer Temperature Range | Ambient to 50 °C (1 °C increment) |
| Light Source | 650 nm, 30 mW Semiconductor Laser |
| Photodetector | Photomultiplier Tube (PMT) |
| Data Acquisition Rate | 20 Hz |
| Baseline Noise | ≤ 0.03 mV |
| Baseline Drift | ≤ 0.3 mV / 60 min |
| Quantitative Reproducibility (RSD) | ≤ 2% |
| Minimum Detectable Mass | < 1 ng |
| Typical Linear Quantitation Range | 0.1–30 µg |
| Gas Supply | Clean, oil-free air or nitrogen |
| Gas Pressure Range | 2–5 bar |
| Gas Flow Control | Mass Flow Controller, accuracy ≤ ±1% or ±0.02 L/min |
| Gain Adjustment | Linear, 0.3–30× continuous |
| Analog Output | –1200 to +1200 mV |
| Digital Interfaces | RS-232, USB, LAN (TCP/HTTP), programmable external event I/O |
| Power | 85–264 VAC, 50 Hz |
| Dimensions (W×H×D) | 260 × 190 × 460 mm |
| Weight | 10 kg |
| Brand | Sanotac |
|---|---|
| Model | ELSD-6000 |
| Detector Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Principle | Low-Temperature Evaporation Mode |
| Light Source | Semiconductor Laser |
| Evaporation Temperature Range | Ambient to 130 °C (1 °C increment) |
| Nebulization Temperature Range | Ambient to 56 °C (1 °C increment) |
| Temperature Control Accuracy | ±1 °C |
| Gas Requirement | Clean Compressed Air or Nitrogen |
| Gas Pressure Range | 2–5 bar |
| Gas Pressure Sensing Accuracy | 0.01 bar |
| Gas Flow Rate | 1–4 L/min |
| Gas Flow Control Accuracy | ≤1% or 0.02 L/min |
| Mobile Phase Flow Rate | 0.01–3 mL/min |
| Baseline Noise | ≤0.03 mV |
| Baseline Drift | ≤0.3 mV / 30 min |
| Minimum Detectable Mass | <1 ng |
| Typical Quantitation Range | 0.1–30 µg |
| Quantitation Repeatability (RSD₆) | ≤2% |
| Dynamic Range | 10⁴ (at fixed gain) |
| Analog Output Range | −1200 to +1200 mV |
| Gain Adjustment | Continuous, 0.3–30× |
| Output Offset Range | −1000 to +1000 mV |
| Sampling Rate | 100 Hz (digital), 20 Hz (analog) |
| Dimensions (W×H×D) | 26×19×46 cm |
| Weight | 10 kg |
| Power Supply | 85–264 VAC, 50 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | ELSD2000 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | Semiconductor Laser |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | ELSD3300 |
| Light Source | 650 nm, 30 mW laser |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 650 nm |
| Optical Design | Dual-beam |
| Spectral Bandwidth | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.01% |
| Baseline Noise | ≤0.01 mV |
| Baseline Drift | ≤0.2 mV / 30 min |
| Detection Limit | 0.5 ng |
| Quantitative Repeatability | ≤1.5% |
| Dynamic Range | 10⁴ (fixed gain) |
| Nebulizer Temp. Range | RT–56 °C (1 °C step) |
| Evaporator Temp. Range | RT–150 °C (1 °C step) |
| Temp. Control Accuracy | ±1 °C |
| Gas Supply | Clean air or nitrogen (2–5 bar) |
| Gas Flow Control | Mass flow controller (accuracy ±0.02 L/min) |
| Mobile Phase Flow Rate | 0.01–3 mL/min |
| Analog Output | −1200 to +1200 mV |
| Gain Adjustment | 0.3–30 (continuous) |
| Sampling Rate | 100 Hz (digital), 20 Hz (analog) |
| Dimensions (W×H×D) | 26 × 19 × 46 cm |
| Weight | 10 kg |
| Power | 85–264 VAC, 50 Hz |
| Compliance | CE-marked |
| Communication Interfaces | RS-232, RS-485, USB, LAN (TCP/HTTP) |
| Software Compatibility | Sanotac proprietary chromatography software |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ELSD-5000 |
| Detection Principle | Evaporative Light Scattering Detection (ELSD) |
| Wavelength | 650 nm semiconductor laser |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | 650 nm semiconductor laser diode |
| Evaporator Temperature Range | Ambient to 130 °C (1 °C increment, accuracy ±1 °C) |
| Nebulizer Temperature Range | Ambient to 56 °C (1 °C increment, accuracy ±1 °C) |
| Carrier Gas | Clean compressed air or nitrogen |
| Gas Pressure Range | 2–5 bar (pressure sensing resolution: 0.01 bar) |
| Gas Flow Rate | 1–4 L/min (control accuracy: ≤1% or ±0.02 L/min) |
| Mobile Phase Flow Rate Compatibility | 0.01–3 mL/min |
| Baseline Noise | ≤0.03 mV |
| Baseline Drift | ≤0.3 mV / 30 min |
| Minimum Detectable Mass | <1 ng |
| Typical Quantitative Range | 0.1–30 µg |
| Relative Standard Deviation (RSD) for Quantitation | ≤2% |
| Dynamic Range (fixed gain) | 10⁴ |
| Analog Output Range | −1200 to +1200 mV |
| Gain Adjustment | 0.3–30 (continuous) |
| Auto-Zero & Output Offset | −1000 to +1000 mV |
| Data Acquisition Rate | 100 Hz (digital), 20 Hz (filtered output) |
| Interface | RS-232, USB |
| Dimensions (W×H×D) | 26×19×46 cm |
| Weight | 10 kg |
| Power Supply | 120/240 V, 50/60 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ELSD5000 |
| Detection Principle | Evaporative Light Scattering Detection (ELSD) |
| Light Source | 650 nm Semiconductor Laser |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation Mode |
| Dimensions (W×H×D) | 26 × 19 × 46 cm |
| Weight | 10 kg |
| Evaporation Temperature Range | Ambient to 130 °C (1 °C increment) |
| Nebulization Temperature Range | Ambient to 56 °C (1 °C increment) |
| Temperature Control Accuracy | ±1 °C |
| Carrier Gas | Clean Compressed Air or Nitrogen |
| Gas Pressure Range | 2–5 bar |
| Gas Pressure Sensing Accuracy | 0.01 bar |
| Gas Flow Rate | 1–4 L/min |
| Gas Flow Control Accuracy | ≤1% or 0.02 L/min |
| Mobile Phase Flow Rate Compatibility | 0.01–3 mL/min |
| Baseline Noise | ≤0.04 mV |
| Baseline Drift | ≤0.4 mV / 30 min |
| Minimum Detectable Mass | <1 ng |
| Typical Quantitative Range | 0.1–30 µg |
| Quantitative Repeatability (RSD) | ≤2% |
| Analog Output Range | −1200 to +1200 mV |
| Gain Adjustment Range | 0.3–30 (continuous) |
| Data Acquisition Rate | 100 Hz (digital), 20 Hz (analog) |
| Communication Interfaces | RS-232, RS-485, USB, LAN (TCP/HTTP), Programmable External Event I/O |
| Power Supply | 120/240 V, 50/60 Hz |
| Regulatory Compliance | FDA 21 CFR Part 11 (audit trail enabled in Clarity®-compatible software) |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | Semiconductor Laser Diode |
| Dimensions (W×H×D) | 26 × 19 × 46 cm |
| Weight | 10 kg |
| Power Supply | 85–264 VAC, 50 Hz |
| Baseline Noise | ≤ 0.03 mV |
| Baseline Drift | ≤ 0.3 mV / 30 min |
| Minimum Detectable Mass | < 1 ng |
| Quantitative Range | 0.1 µg – 30 µg |
| Precision (RSD) | ≤ 2% |
| Dynamic Range | 10⁴ (fixed gain) |
| Nebulizer Temp Range | RT–56 °C (1 °C increment) |
| Evaporator Temp Range | RT–130 °C (1 °C increment) |
| Temperature Accuracy | ±1 °C |
| Carrier Gas | Clean compressed air or nitrogen |
| Gas Pressure Range | 2–5 bar |
| Pressure Sensing Accuracy | 0.01 bar |
| Gas Flow Range | 1–4 L/min |
| Flow Control Accuracy | ≤1% or 0.02 L/min |
| Mobile Phase Flow Rate Compatibility | 0.01–3 mL/min |
| Analog Output | −1200 to +1200 mV |
| Gain Adjustment | 0.3–30 (continuous) |
| Data Acquisition Rate | 100 Hz (digital), 20 Hz (analog) |
| Communication Interfaces | RS-232, RS-485, USB, LAN (TCP/HTTP) |
| Software Integration | Sanotac-native chromatography software & Clarity® DLL-compatible platform (with Colibrick™ driver support) |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ELSD6000 Plus |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | Semiconductor Laser |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | ELSD9000 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Conventional HPLC-Compatible Detector |
| Flow Rate Range | 0.01–3 mL/min |
| Max Operating Pressure | 1 bar |
| Sample Injection Port | Single-channel |
| Injection Volume Range | Not applicable (flow-through detector) |
| Temperature Control Range | Ambient to 150 °C (1 °C step resolution) |
| Light Source | 650 nm, 30 mW laser diode |
| Data Acquisition Rate | 20 Hz (digital output), 100 Hz (internal sampling) |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ePilot-100 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ePurify-100 |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Origin | Yes |
| Model | ePurify100 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 10 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU at 254 nm, TC = 1 s |
| Data Acquisition Rate | 10 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Flash 100 |
| Price Range | USD $14,000–$28,000 (FOB Shanghai) |
| Application Level | Laboratory-Scale Purification |
| Instrument Type | Medium-Pressure Preparative HPLC System |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75×10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Rate | 10 Hz |
| Gradient Capability | Up to 4-Solvent Linear/Step Gradients |
| Fraction Collection Modes | Time-, Peak-, Threshold-, and Slope-Triggered |
| Software Compliance | FDA 21 CFR Part 11 & CFDA GxP-Compliant Sanochrom™ Control Software |