| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | CFI20 |
| Pricing | Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T100-MST20 |
| Price | Upon Request |
| Temperature Range | RT + 5°C to 100°C |
| Temperature Stability | ±0.05°C |
| Display | 4-digit LED |
| Temperature Resolution | 0.1°C |
| Heating Power | 1.3 kW (230 V) / 1.4 kW (120 V) |
| Bath Opening | 240 × 210 mm |
| Bath Capacity | 20 L |
| Minimum/Maximum Liquid Depth | 185 / 225 mm |
| Total Power Consumption | 1.4 kW (230 V, 50/60 Hz) / 1.5 kW (120 V, 50/60 Hz) |
| Max. Gerber Fat Meter Capacity | 36 units (3 × H1-25M racks, 12 per rack) |
| Safety Features | Fixed overtemperature cut-off, low-level fluid alarm |
| Control System | Detachable digital PID controller with adaptive tuning, 3 programmable setpoints, flywheel + dual-button interface |
| Construction | Acid-resistant stainless steel inner tank and outer housing, removable stainless steel lid with ergonomic handles |
| Immersed Components | Acid-resistant heater, float switch, and Pt100 temperature sensor |
| Calibration | User-executable self-calibration routine |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | WB 436-D |
| Bath Volume | 16 L |
| Temperature Range | Ambient to 99 °C |
| Temperature Stability | ±0.3 °C (at 37 °C, steady state) |
| Circulation | Internal & External Pump |
| Power | 1000 W |
| Voltage/Frequency | 230 V / 50–60 Hz |
| Display | 4-digit LED |
| Timer Range | 1–99 min |
| Dimensions (L×W×H) | 396 × 331 × 265 mm |
| Weight | 10.1 kg |
| Construction | Stainless Steel Inner & Outer Chamber |
| Overheat Protection | Dual-stage thermal cutoff |
| Recommended Fluid | Distilled Water |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Type | Manual Bottle Top Dispenser |
| Volume Range | 0.25–50 mL |
| Graduation Interval | 0.25 mL |
| Accuracy | ±0.5% |
| Precision | 99.5% |
| Available Models | 2.50 mL, 5.00 mL, 10.00 mL, 25.00 mL, 50.00 mL |
| Compliance | ISO 8655-3, DIN EN ISO 8655-3, GLP-ready design |
| Brand | Gerhardt (C. Gerhardt) |
|---|---|
| Origin | Germany |
| Model | Dumatherm DT N Pro |
| Configuration | Pneumatic autosampler (64-position standard |
| Detection Principle | High-temperature combustion followed by thermal conductivity detection (TCD) and/or chemiluminescence detection (CLD) of nitrogen oxides after catalytic reduction |
| Sample Forms | Solid, liquid, semi-solid (paste) |
| Typical Analysis Time | ≤180 s per sample |
| Nitrogen Range | Up to 50 mg N per analysis |
| RSD | <0.5% (absolute, for 200 mg EDTA reference) |
| Carrier Gas Options | Helium (optimal sensitivity) or Argon (cost-optimized) |
| Oxygen Delivery | Software-controlled precise dosing |
| Compliance | AOAC, DIN EN ISO, USP, and national food/feed/environmental standards |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | KI 1 |
| Maximum Temperature | 600 °C |
| Heating Zone | Single |
| Flask Capacity Range | 50–250 mL |
| Dimensions (W×D×H) | 150 × 225 × 130 mm |
| Weight | 2 kg |
| Voltage | 230 V AC |
| Frequency | 50/60 Hz |
| Power Rating | 450 W |
| Ordering Code | 10-0003 |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | EV1 |
| Order No. | 10-0001 |
| Max Temperature | 425 °C |
| Heating Position | 1 |
| Power | 450 W |
| Voltage | 230 V AC, 50/60 Hz |
| Temperature Control Range | 0–425 °C (adjustable in 1 °C increments) |
| Temperature Stability | ±1 °C at 425 °C (typical, after thermal equilibrium) |
| Heating Time (RT → 425 °C) | ≤5 min |
| Dimensions (W×D×H) | 150 × 225 × 110 mm |
| Net Weight | 2.0 kg |
| Compliance | CE, IEC 61010-1, RoHS |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model(s) | EV1 (1-position), EV14 (4-position), EV16 (6-position) |
| Max Temperature | 425 °C |
| Block Dimensions (EV1) | 150 × 225 × 110 mm |
| Weight (EV1) | 2 kg |
| Voltage | 230 V AC |
| Frequency | 50/60 Hz |
| Power (EV1) | 450 W |
| Heating Element | Precision-machined aluminum alloy block with embedded resistance heaters |
| Control Type | Analog dial with mechanical thermostat (EV1) / Digital PID controller with LED display (EV14/EV16, optional upgrade) |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | EV 16 |
| Heating Power | 2700 W |
| Max. Operating Temperature | 450 °C |
| Temperature Uniformity | ±1 °C across Heating Zone |
| Heating Surface Diameter | 85 mm |
| Overall Dimensions (W × D × H) | 900 × 225 × 110 mm |
| Weight | 10 kg |
| Voltage | 230 V AC |
| Frequency | 50/60 Hz |
| Number of Heating Positions | 6 |
| Heating Technology | Infrared Radiant Heating |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model | EV6 AII14 / EV6 AII16 |
| Max. Heating Temperature | 425 °C |
| Heating Block Positions | 4 / 6 |
| Flask Capacity | 250–500 mL |
| Voltage | 230 V AC |
| Frequency | 50–60 Hz |
| Power Consumption | 1800 W / 2700 W |
| Dimensions (W×D×H) | 600×225×650 mm / 900×225×650 mm |
| Weight | 10 kg / 14 kg |
| Compliance | ASTM D2230, ISO 6496, AOAC 920.39, USP <467> |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Product Type | Imported Laboratory Instrument |
| Model | HT6+SOX416 |
| Extraction Chamber Volume | 150 mL |
| Receiver Flask Volume | 200 mL |
| Temperature Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Number of Parallel Channels | 6 |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | HYDROTHERM HT6 |
| Extraction Chamber Volume | 1 L |
| Receiving Flask Volume | 1 L |
| Temperature Range | Ambient to 120 °C (typical for acid hydrolysis) |
| Temperature Control Accuracy | ±1 °C |
| Throughput | 6 samples per run (3 dual-position modules) |
| Compliance | Designed for ISO 1444–1, AOAC 991.36, and USP <467> compliant workflows |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model | KT / KT-L |
| Sample Capacity | 8/20/40 positions |
| Digestion Tube Sizes | 100 mL, 250 mL, 400 mL |
| Temperature Control Accuracy | ±0.5% of setpoint |
| Programmable Methods | 99 methods, up to 40 temperature ramps per method |
| Predefined Methods | 30 standard protocols |
| Heating Rate | Adjustable |
| Safety Features | Overheat protection, acid drip tray, audible/visual alarms, automatic fume extraction activation, user-configurable safety cutoff temperature |
| Compliance | ISO/IEC 17025, GLP, FDA 21 CFR Part 11 (audit trail & user access control), DIN EN ISO 5983, AOAC 984.13, EPA 350.1, ASTM D5142, EU Regulation (EC) No 152/2009, APHA 4500-Norg, Ph. Eur. 2.5.33 (Method 7, Step A) |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | Electric Heating Digestion Instrument |
| Automation Level | Semi-Automatic |
| Digestion Positions | 8 / 20 / 40 |
| Max. Heating Temperature | 430 °C |
| Temperature Control Accuracy | ±0.5% |
| Heating Principle | Aluminum Block Heating |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Product Type | Imported Manual Single-Channel Volumetric Pipettes |
| Models | 4201 (0.25–2.50 mL), 4202 (0.50–5.00 mL), 4203 (1.00–10.00 mL), 4204 (2.50–25.00 mL), 4205 (5.00–50.00 mL) |
| Max Capacity | 2.5 mL / 5 mL / 10 mL / 25 mL / 50 mL |
| Accuracy Tolerance | ±0.025 mL |
| Operation Mode | Manual |
| Channel Count | Single |
| Compliance | ISO 8655-2:2022 (Volumetric pipettes – Part 2: Piston-operated volumetric apparatus) |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 300 °C |
| Extraction Cell Volume | 100 mL or 150 mL |
| Extraction Time | 0–120 min |
| Dimensions (W×D×H) | 525 × 410 × 580 mm (SOX 416 Macro) |
| Sample Capacity | 2, 4, 6, or up to 24 positions (via modular configuration) |
| Power Supply | 230 VAC, 50/60 Hz |
| Power Consumption | 1200 W |
| Weight | 42 kg |
| Cooling Water Flow | 0.5–3.5 L/min, min. pressure 0.3 bar |
| Communication Interface | Dual RS-485 ports |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | SOXTHERM |
| Extraction Chamber Volume | 200 mL |
| Receiver Flask Volume | 100 mL or 150 mL |
| Temperature Range | up to 300 °C |
| Temperature Control Accuracy | ±1 °C |
| Channel Configurations | 2, 4, 6, or modular up to 24 parallel units |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | Electric Heating Digestion Instrument |
| Automation Level | Fully Automatic |
| Digestion Positions | 20 |
| Max Heating Temperature | 240 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Principle | Resistive Electric Heating |
| Reagent Channels | 20 |
| Programmable Methods | 99 |
| Max Heating Stages per Method | 40 |
| Predefined Methods | 30 |
| Heating Rate Control | Variable |
| Footprint | 51.5 × 48.3 cm |
| Digestion Vessel Capacity | Up to 250 mL (8 samples simultaneously in standard configuration) |
| Safety Features | Integrated fume extraction interface, motorized lift stage, preheating function, automated TURBOSOG® and cooling water valve actuation |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | SMA 8s |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Fully Automatic |
| Digestion Positions | 8 |
| Max Heating Temperature | 240 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Principle | Electrical Resistance Heating |
| Reagent Dispensing Channels | 0 (No reagent addition) |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | Imported |
| Model | TTs125 |
| Max Temperature | 650 °C |
| Heating Element | Special Infrared Alloy |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | TUR/K |
| Voltage | 230 V AC |
| Frequency | 50–60 Hz |
| Power Consumption | 205 W |
| Weight | 19 kg |
| Dimensions (W × D × H) | 330 × 450 × 420 mm |
| Application | Laboratory-scale waste gas scrubbing and aqueous effluent conditioning |
| Maintenance Requirement | Minimal (no consumable scrubbing media required) |
| Compliance | Designed for integration into GLP-compliant laboratory workflows |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | VS |
| Application | Laboratory Acid Fume Treatment |
| Principle | Dilution, Chemical Neutralization, Absorption |
| Flow Rate | 120 L/min |
| Compliance | Meets German TRGS 554 and EU Directive 2010/32/EU for laboratory fume control |
| Power Consumption | 100 W |
| Noise Level | <52 dB(A) |
| Maintenance | Tool-free access via top-hinged door |
| Cooling | Integrated condensate trap |
| Filtration | Dual-stage — chemical scrubbing + optional solid-phase adsorption cartridge |
| Compatibility | Fully interoperable with Gerhardt KJELDATHERM, TURBOTHERM, KI digestion units and SMA series reflux digesters |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | VAP450 |
| Instrument Type | Quartz Glass Distillation Apparatus |
| Heating Method | Electric |
| Cooling Method | External Circulating Chiller or Tap Water |
| Distillation Rate | 30 samples/hour |
| Heating Position | 1-place |
| Power Consumption | 2200 W |
| Voltage/Frequency | 230 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 527 × 390 × 697 mm |
| Weight | 34 kg |
| Water Consumption | ~3 L/min |
| Typical Distillation Time | 3 min 30 s |
| Repeatability | ±1% |
| Detection Limit | 0.1 mg |
| Recovery Rate | >99.5% |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Model | Vapodest 300 |
| Water Consumption | ~3 L/min |
| Distillation Time | ~3 min 30 s (standard Kjeldahl method) |
| Power | 2200 W |
| Frequency | 50/60 Hz |
| Weight | 34 kg |
| Dimensions | 527 × 390 × 697 mm |
| Repeatability | ±1% |
| Detection Limit | 0.1 mg |
| Supply Voltage | 230 V AC |
| Nitrogen Recovery Rate | >99.5% |
| Brand | Gerhardt (C. Gerhardt) |
|---|---|
| Origin | Germany |
| Model | Vapodest 450 |
| Configuration | Standalone Steam Distillation Unit with Optional External Titrator Integration |
| Compliance | Designed for ASTM D1193, ISO 8968-1, ISO 5983-1, AOAC 981.10, USP <467>, and EN ISO 1871 |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Model | NORMAG Vacuum Batch Distillation System |
| Construction Material | High-purity quartz glass (Duran®-grade) |
| Vacuum Capability | Up to 10⁻⁶ mbar |
| Tower Types Available | Packed column, sieve plate column, Vigreux column, micro-rotating band column |
| Thermal Insulation | High-vacuum silvered jacket (10⁻⁶ mbar interlayer) |
| Visual Access | Full-length vertical observation window |
| Structural Feature | Axial thermal expansion compensation corrugated section |
| Control Interface | PC-based LabVIEW-compatible digital control system |
| Compliance | Designed for GLP-compliant operation and ASTM D2892 / ISO 6617 applicability |
| [Origin | Germany |
|---|---|
| Model | Zennium Pro |
| Potentiostat/Galvanostat Bandwidth | 10 MHz |
| ADC Resolution | 32 bit |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Frequency Accuracy | ±0.0025% |
| Frequency Resolution | 10,000 steps/decade |
| AC Amplitude Range | 0–6 V |
| Impedance Measurement Range | 1 mΩ – 10 GΩ (±2%), 100 mΩ – 10 MΩ (±0.2% for POT mode), 10 µΩ – 1 GΩ (±2% for GAL mode), 100 mΩ – 100 GΩ (±2% with HIZ probe) |
| Max Current Output | ±3 A |
| Applied Potential Range | ±15 V |
| Cell Voltage Range | ±28 V |
| Voltage Resolution | 3 nV |
| Current Resolution | ±5 aA |
| Small-Signal Rise Time | 150 ns – 200 µs (5-step auto-ranging) |
| Input Impedance | >10 TΩ |
| Grounding Modes | Switchable floating/grounded configuration |
| IR Compensation | Real-time automatic iR compensation |
| Software Platform | Thales XT with Zahner SIM, Z-HIT, EIS time-series analysis, equivalent circuit fitting, GITT/PITT, RDE/RRDE, battery cycling, electrochemical noise, and photoelectrochemical modules] |
| Origin | Germany |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Heating Power Range | 20–1000 W |
| Cleaning Medium | Pulsed Fiber Laser (1064 nm) |
| External Dimensions (L×W×D) | 50 × 50 × 70 cm (Mobile Configuration) |
| Cooling Method | Air-Cooled (≤600 W) |
| Control Interface | Touchscreen HMI |
| Origin | Germany |
|---|---|
| Type | Imported Laboratory Equipment |
| Model Series | 8000 (TS8024, TS8056, TS8136, TS8265, TS8430) |
| Capacity | 24–430 L |
| Temperature Range | Ambient +5°C to 250°C |
| Temperature Uniformity | ±1.5% (spatial), ±1°C (temporal stability) |
| Control System | PID with Dual K-Type Thermocouples |
| Power Supply | 220 V, 50 Hz |
| Compliance | CE-marked, IEC 61010-1, EN 60529 (IP20) |
| Brand | The Great Wall |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Direct Producer |
| Country of Origin | China |
| Model | GFY-10L |
| Capacity | 10 L |
| Vessel Material | High-Borosilicate Glass (DIN/ISO 3585 compliant) |
| Operating Pressure Range | Medium-pressure (up to 0.4 MPa gauge) |
| Ultimate Vacuum | ≤ –0.098 MPa (absolute, equivalent to ~2 mbar) |
| Valve Type | PTFE/FKM rotary stopcock with precision flow control |
| Stirring | Variable-speed overhead mechanical stirrer (0–200 rpm, torque-regulated) |
| Application Class | Pilot-scale liquid–liquid extraction |
| Compliance | Designed per GB/T 21673–2008 (Laboratory Glassware — Specifications for Separatory Funnels), compatible with ISO 17025-accredited lab workflows |