Common Laboratory Equipment
Filter
Showing 8011–8040 of 18361 results
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | DHL-C |
| Flow Rate | 2 × (0.1–1099) mL/h |
| Pressure Rating | ≥3 kg/cm² |
| Display | 3.5-inch HD touchscreen LCD (Chinese UI) |
| Pump Head | DHL-series 6-roller peristaltic head |
| Speed Range | 0.1–75 rpm, reversible |
| Tube Compatibility | Ø1.2×3 mm and Ø3×5 mm silicone/fluoroelastomer tubing |
| Power Input | AC 220 V, 50/60 Hz |
| Dimensions (L×W×H) | 125 × 150 × 180 mm |
| Weight | 1.55 kg |
| Calibration Function | Yes (user-input actual flow for auto-correction) |
| External Control Interface | TTL-level start/stop signal output for fraction collector synchronization |
| Full-Speed Mode | Dedicated “All-Speed” key for priming and tube purging |
| Quantitative Dispensing Range | 0.1 mL–99999.9 mL |
| Timing Range | 0.1 s–99999.999 h |
| Distribution Parameters | Time per fraction 0–6553.5 s |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HL-2B |
| Pump Type | Peristaltic Pump |
| Flow Rate Range | 2 × (0.5–900) mL/h |
| Speed Range | 0–65 rpm |
| Maximum Pressure | 3 kg/cm² |
| Display | Gold LED Digital Screen |
| Motor Type | Stepper Motor with Multi-Step Drive |
| Tubing Compatibility | 1.2×3 mm and 3×5 mm ID×OD silicone or Tygon® tubing |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 125×150×180 mm |
| Weight | 1.5 kg |
| Enclosure Material | ABS Plastic (Injection-Molded, Full-Enclosure Design) |
| Control Interface | Front-panel keypad + external TTL-compatible control port for integration with fraction collectors |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HL-2F |
| Pump Type | Dual-Channel Peristaltic Pump |
| Flow Rate Range | 2 × (0.5–900) mL/h |
| Speed Range | 0–65 rpm (dispensing mode: 0–60 rpm) |
| Pressure Rating | 3 kg/cm² |
| Display | Gold LED Digital Screen |
| Pump Head | Dual 6-Roller with PTFE Housing |
| Tubing Compatibility | 1.2×3 mm and 3×5 mm ID/OD |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (L×W×H) | 125 × 150 × 180 mm |
| Weight | 1.5 kg |
| Direction Control | Bidirectional (Forward/Reverse) |
| Enclosure Material | ABS Plastic (Injection-Molded, Full-Enclosure Design) |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | Jiapeng |
|---|---|
| Model | TH-1000A |
| Gradient Volume Capacity | 2000 mL |
| Gradient Profile Type | Linear |
| Solvent Compatibility | Organic Solvent–Resistant Construction |
| Display | LED Digital Speed Indicator |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (L×W×H) | 270 × 170 × 90 mm |
| Net Weight | 1.2 kg |
| Application Class | Laboratory Gradient Generation System for Chromatography & Fractionation |
| Instrument Type | Magnetic Stirrer–Integrated Gradient Mixer |
| Maximum Stirring Volume (as stirrer mode) | 1000 mL |
| Brand | Jiapeng |
|---|---|
| Model | TH-300A |
| Gradient Volume | 600 mL |
| Gradient Profile | Linear |
| Solvent Compatibility | Organic-solvent resistant |
| Display | LED digital speed indicator |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 270 × 170 × 90 mm |
| Weight | 1.2 kg |
| Instrument Type | Magnetic Stirrer-Integrated Gradient Mixer |
| Brand | Jiapeng |
|---|---|
| Model | TH-500A |
| Gradient Volume Capacity | 1000 mL |
| Gradient Profile | Linear Only |
| Solvent Compatibility | Organic Solvent–Resistant Construction |
| Display | LED Digital Speed Readout |
| Input Power | AC 220 V, 50/60 Hz |
| Dimensions (L×W×H) | 270 × 170 × 90 mm |
| Weight | 1.2 kg |
| Equipment Type | Magnetic Stirrer–Integrated Gradient Mixer |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | Vortex-3 |
| Speed Range | 0–2800 rpm |
| Operating Modes | Continuous / Touch-Start (Pulse) |
| Motion Type | Orbital (Circular) |
| Platform Amplitude | 5 mm |
| Display | Analog Scale (Calibrated Dial) |
| Housing Material | ABS Engineering Plastic |
| Platform Surface | Wear-Resistant Rubber |
| Input Voltage | 198–242 V AC, 50 Hz |
| Power Consumption | 60 W (Motor Input: 85 W |
| Mechanical Output | 15 W) |
| Ambient Operating Conditions | 5–40 °C, ≤80% RH |
| IP Rating | IP56 |
| Dimensions (W×D×H) | 140 × 145 × 145 mm |
| Net Weight | 1.75 kg |
| Compliance | Designed for general laboratory use per IEC 61010-1 safety requirements |
| Brand | Jiaxinhai |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Circular Split Die, 61–70 mm Diameter |
| Price | USD 700 (FOB Tianjin) |
| Brand | Jiaxinhai |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JPT-10 |
| Price | USD 850 (FOB Tianjin) |
| Brand | Jiayuan |
|---|---|
| Origin | Shanghai, China |
| Model | 85-2 |
| Stirrer Type | Magnetic Stirrer |
| Max. Stirring Volume | 10 L (water) |
| Speed Range | 100–2000 rpm |
| Heating Power | 350 W |
| Temperature Control Range | Ambient to 150 °C (within 1 L volume) |
| Heating Plate Diameter | Φ145 mm |
| Dimensions | 250 × 150 × 130 mm |
| Construction | Stainless Steel Heating Plate |
| Regulatory Status | Domestic Manufacturing |
| Distribution Channel | General Distributor |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | BTH-100 |
| Temperature Range (Heating) | RT + 5°C to 100°C |
| Temperature Range (Cooling) | –10°C to 100°C |
| Temperature Stability @ 100°C | ≤ ±0.5°C |
| Block Uniformity | ≤ ±0.3°C |
| Display Resolution | 0.1°C |
| Ramp Time (20°C → 100°C) | ≤ 15 min |
| Cooling Time (RT → RT–25°C, ambient ≤ 26°C) | ≤ 25 min |
| Max Power | 150 W |
| Dimensions (W×D×H) | 260 × 240 × 168 mm |
| Net Weight | 2.2 kg |
| Module Capacity | Up to 8 interchangeable blocks |
| Timer Range | 0–99 h 59 min |
| Brand | JIAYUAN |
|---|---|
| Model | DKT200-2A |
| Temperature Range | Ambient +5°C to 150°C |
| Temperature Accuracy | ≤ ±0.5°C (40–100°C), ≤ ±1.0°C (100–150°C) |
| Temperature Uniformity | ≤ ±0.5°C across block surface |
| Max Block ΔT at 40°C differential | 0.3°C |
| Heating Time | ≤30 min (20°C → 150°C) |
| Display Resolution | 0.1°C |
| Timer Range | 1 min – 99 h 59 min |
| Max Power | 400 W |
| Dimensions (W×D×H) | 260 × 290 × 95 mm |
| Compatible Modules | DT01–DT19 (including 0.2 mL × 96, 1.5/2.0 mL × 24, 13–28 mm tube formats, 96-well PCR/ELISA plates, and custom blocks) |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | DMT-2500 |
| Speed Range | 500–2500 rpm |
| Speed Accuracy | ±50 rpm (at 2500 rpm) |
| Orbital Diameter | 4 mm |
| Display | LED |
| Operating Modes | Touch-Start & Timer |
| Timer Range | 1 s – 9999 min |
| Max Load Capacity | 5 kg |
| Top Plate Dimensions | 311 × 184 mm |
| Overall Dimensions | 426 × 250 × 480 mm |
| Net Weight | 21.5 kg |
| Power Supply | 100–230 V, 50/60 Hz |
| Power Consumption | 60 W |
| Standard Accessories | 12 mm foam tube rack + tray pad |
| Optional Foam Racks | DMT-A (50×Φ10 mm), DMT-B (50×Φ12 mm), DMT-C (50×Φ13 mm), DMT-D (50×Φ16 mm, fits 15 mL centrifuge tubes), DMT-E (15×Φ25 mm), DMT-F (15×Φ29 mm, fits 50 mL centrifuge tubes), DMT-H (replaceable upper & lower tray pads) |
| Brand | Jiayuan |
|---|---|
| Model | ET-60 |
| Temperature Range | Ambient +5°C to 60°C |
| Timer Range | 1 min – 99 h 59 min |
| Temperature Uniformity | ±0.5°C |
| Temperature Stability | ±0.2°C |
| Temperature Accuracy | ±0.5°C |
| Power Supply | 220 V, 2.5 A, 200 W |
| Incubation Chamber Dimensions | 245 × 215 × 85 mm |
| External Dimensions | 395 × 275 × 130 mm |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | FSTPRP-24 |
| Instrument Type | Cryogenic Ball Mill |
| Sample Compatibility | Frozen & temperature-sensitive materials |
| Maximum Feed Size | ≤ 8 mm |
| Final Particle Size | 0–5 µm |
| Throughput | 24 × 1.5 mL tubes |
| Operating Temperature Range | −196 °C to −100 °C |
| Frequency Range | 1–70 Hz (30–2100 rpm, equivalent to 100–7000 impacts/min) |
| Grinding Vessel Options | 1.5, 2, 5, 10, 25, 35, 50 mL |
| Vessel Materials | Stainless steel, PTFE |
| Grinding Media | Stainless steel, chrome steel, zirconia, tungsten carbide, quartz |
| Safety Certification | ISO, CE |
| Cooling Method | Liquid nitrogen (LN₂) or optional air-cooling unit |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FW-4 |
| Instrument Type | Manual Hydraulic Pellet Press |
| Pressure Range | 0–24 T (0–38 MPa) |
| Maximum Piston Stroke | 20 mm |
| Oil Cylinder Diameter | Φ70 mm |
| Pressure Gauge | Dual-Scale Analog Pressure Gauge |
| Working Table Diameter | 80 mm |
| Working Chamber Dimensions | 120 × 120 × 130 mm |
| Pressure Stability | ≤1 MPa/10 min |
| Net Weight | 25 kg |
| Overall Dimensions | 240 × 170 × 390 mm |
| Construction | Monolithic Cast Aluminum Base Plate, Chrome-Plated Oil Cylinder, Four-Guided Column Architecture |
| Handle & Crank Material | Anodized Aluminum Alloy |
| Brand | JIAYUAN |
|---|---|
| Model | HA-300 |
| Hydrogen Purity | 99.999% |
| Hydrogen Flow Rate | 0–300 mL/min |
| Hydrogen Pressure | 0–0.4 MPa (factory-set at 0.3 MPa) |
| Air Flow Rate | 0–2000 mL/min |
| Air Pressure | 0–0.4 MPa |
| Operating Noise | <40 dB(A) |
| Ambient Humidity | ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 500 × 300 × 380 mm |
| Weight | 20 kg |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HG1802 |
| Hydrogen Purity | 99.999% |
| Hydrogen Flow Rate | 0–200 mL/min |
| Flow Display | LED Digital |
| Operating Pressure | 0–0.4 MPa (factory-set at 0.3 MPa) |
| Pressure Stability | ±0.02 MPa |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 150 W |
| Ambient Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions (W×D×H) | 400 × 180 × 380 mm |
| Net Weight | ~12 kg |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY-1508A |
| Max Sample Section Size | 50×40 mm |
| Section Thickness Range | 1–30 µm |
| Minimum Thickness Increment | 1 µm |
| Sectioning Accuracy | ±5% |
| Dimensions | 400×350×350 mm |
| Compliance | CE-marked for laboratory use |
| Optional Accessories | Disposable blade holder |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY-1508AIII |
| Maximum Specimen Size | 50 × 30 mm |
| Section Thickness Range | 1–30 µm |
| Minimum Thickness Increment | 1 µm |
| Cryostage Max. Area | 45 × 40 mm |
| Temperature Differential (Cryostage) | ≥60 °C |
| Temperature Differential (Cryo-Knife) | ≥50 °C |
| Cooling Time to Operating Temp | 4–8 min |
| Knife Angle | 45° |
| Dimensions | 400 × 350 × 350 mm |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY-1508R |
| Max Sample Section Size | 60 × 45 mm |
| Slice Thickness Range | 1–60 µm |
| Trim Thickness Range | 1–60 µm |
| Minimum Increment | 1 µm |
| Slice Accuracy | ±5% |
| Horizontal Specimen Translation | 28 mm |
| Vertical Specimen Translation | 60 mm |
| Specimen Orientation Adjustment | ±8° horizontal, ±8° vertical, 360° rotation |
| Knife Base Travel | ±25 mm (front/back) |
| Dimensions | 400 × 350 × 350 mm |
| Compliance | Designed for ISO 13485-aligned lab environments and GLP-compliant histology workflows |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY-1508RIII |
| Max Sample Size | 60×45 mm |
| Section Thickness Range | 1–30 µm |
| Minimum Increment | 1 µm |
| Cryostage Max Area | 45×35 mm |
| Temperature Differential (Cryostage) | ≥60 °C |
| Cooling Rate | 2–7 min to set temperature |
| Blade Angle | 45° |
| Precision | ±5% |
| Dimensions (JY-1508R + JY-III modules) | 400×350×350 mm / 390×180×390 mm |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY-1900 |
| Maximum Sample Size | 35 × 35 mm |
| Section Thickness Range | 1–80 µm |
| Section Increment | 1 µm (1–30 µm), 2 µm (20–40 µm), 5 µm (40–80 µm) |
| Cryochamber Temperature | −5 °C to −35 °C (±2 °C) |
| Specimen Stage Temperature | −10 °C to −55 °C (semiconductor-cooled, ≤15 min to target) |
| Cryo-head Temperature | −5 °C to −40 °C (±2 °C) |
| Knife Temperature | −5 °C to −25 °C |
| Specimen Retraction | 20 µm |
| XY Positioning Accuracy | ±8° tilt, Z-axis 360° rotation |
| Motorized Specimen Advance Speed | 0.8 mm/s |
| Defrost Cycle | Programmable (24-hr adjustable) |
| Power Consumption | 560 W |
| Dimensions (W×D×H) | 600 × 640 × 1150 mm |
| Weight | 120 kg |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY-202AIII |
| Max Sample Size | 40 × 30 mm |
| Section Thickness Range | 1–25 µm |
| Minimum Thickness Increment | 1 µm |
| Cryo Stage Max Area | 45 × 40 mm |
| Knife Angle | 45° |
| Precooling Time | 4–8 min to target temperature |
| Dimensions | 335 × 350 × 300 mm |
| Brand | Jiayuan |
|---|---|
| Model | JY-2508 |
| Origin | Beijing, China |
| Maximum Sample Section Size | 60×40 mm |
| Section Thickness Range | 1–40 µm |
| Minimum Thickness Increment | 1 µm |
| Sectioning Accuracy | ±5% |
| Dimensions | 400×350×350 mm |
| Knife Holder Compatibility | Disposable blade holder (optional) |
| Guideway System | Precision crossed roller bearing guideways |
| Safety Feature | Right-hand single-hand locking handwheel |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY-2508III |
| Max Sample Size | 60×40 mm |
| Section Thickness Range | 1–35 µm |
| Minimum Increment | 1 µm |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY-315III |
| Max Sample Size | 45 × 40 mm |
| Section Thickness Range | 0–60 µm |
| Incremental Step | 0.5 µm (0–2 µm), 1 µm (2–10 µm), 2 µm (10–20 µm), 5 µm (20–60 µm) |
| Horizontal Travel | 28 mm |
| Vertical Travel | 60 mm |
| Sectioning Accuracy | ±5% |
| Cryostage Max Temp Differential | ≥60 °C |
| Cryoblade Max Temp Differential | ≥50 °C |
| Cooling Time to Operating Temperature | 2–7 min |
| Knife Angle | 45° (fixed cold knife geometry) |
| Knife Mounting | Magnetic attachment |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY-335 |
| Maximum Sample Thickness Range | 0–100 µm |
| Sectioning Increment | 1 µm (0–10 µm), 2 µm (10–20 µm), 5 µm (20–50 µm), 10 µm (50–100 µm) |
| Re-Trim Range | 0–500 µm |
| Max Horizontal Specimen Travel | 28 mm |
| Max Vertical Specimen Travel | 60 mm |
| Automatic Specimen Advance & Retraction | 12 µm |
| Minimum Sectioning Resolution | 1 µm |
| Sectioning Accuracy | ±1% |
| Max Section Area | 50 × 50 mm |
| Dimensions | 520 × 450 × 300 mm |
| Power Supply | AC 220 V / 110 V, 50 / 60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY-335III |
| Max Sample Size | 50×45 mm |
| Section Thickness Range | 0–100 µm |
| Section Increment | 1 µm (0–10 µm), 2 µm (10–20 µm), 5 µm (20–50 µm), 10 µm (50–100 µm) |
| Trimming Range | 0–500 µm |
| Horizontal Sample Travel | 28 mm |
| Vertical Sample Travel | 60 mm |
| Automatic Feed & Retraction | 12 µm |
| Feed Resolution | 1 µm |
| Sectioning Accuracy | ±5% |
| Cryostage Max Area | 45×40 mm |
| Blade Angle | 45° |
| Cooling Time | 2–7 min to Operating Temp |
| Dimensions | 520×450×300 mm |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY-800D |
| Operating Temperature Range | 825 °C |
| Temperature Control Accuracy | ±50 °C at 825 °C |
| Heating Power | 250 W |
| Internal Chamber Diameter | φ35 mm |
| Heating Zone Length | 100 mm |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Weight | 1.5 kg |
| Ambient Operating Temperature | 10–50 °C |
| Relative Humidity | ≤90% RH |
| Max. Altitude | Unrestricted |