| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | Plate-Smart |
| Instrument Type | Benchtop Plate Centrifuge |
| Max Speed | 2500 rpm |
| Max RCF | 650 × g |
| Capacity | 4 × 96-well microplates, or 2 × deep-well plates, or 2 × PCR plates |
| Drive System | High-torque disc motor, direct drive |
| Control | Microprocessor-based, digital time/speed display |
| Timer Range | 1–99 min + continuous mode |
| Speed Range | 500–2500 rpm |
| Power Supply | 110–230 V, 50 Hz, 150 W |
| Max Temperature Rise | <12 °C |
| Dimensions (W×D×H) | 310 × 380 × 300 mm |
| Net Weight | 12 kg |
| Safety | Automatic rotor stop upon lid opening, mechanical safety interlock |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLR DHEU-I |
| Power Supply | 220 VAC/50 Hz, 1 A (wide-range input: 110–260 VAC) |
| Light Source | 100 W high-power LED (standard 365 nm UV |
| Gas Collection | water-displacement and water-seal gas collection modes |
| Reactor | jacketed cylindrical reactor with U-shaped quartz window, flanged connection, ~160 mL nominal volume |
| Fuel Cell Output | 0.5–0.7 V, 15–20 mA under typical operating conditions |
| Volume Measurement | integrated sensor module for real-time digital display of gas volume (mL), droplet count, flow rate, and runtime |
| Dimensions | 500 × 454 × 215 mm (L×W×H) |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR OTPR-I |
| Type | In-situ thermometric, gas-permeating photocatalytic reactor for solid-phase catalysts |
| Compatibility | Designed for integration with Labsolar-6A all-glass automated micro-gas analysis system (OTPR-1 variant) or continuous-flow photo(thermal)catalytic setups (OTPR-2 variant) |
| Thermal Management | Integrated thermostatic jacket + non-contact IR temperature monitoring port |
| Gas Flow Mode | Forced-through (transmissive) configuration |
| Sample Forms | Powder, porous thin films, and low-thickness monolithic catalysts |
| Primary Function | Real-time surface temperature measurement during irradiation-driven gas-solid reactions |
| Compliance Context | Engineered for GLP-aligned photocatalysis research |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR RVTF-POX |
| Reaction Pressure Range | 0.2 (gauge) – 6 MPa |
| Reaction Temperature Range | 80 – 600 °C |
| Catalyst Bed Volume | 0.2 – 0.8 mL |
| Reactor Type | Quartz fixed-bed with metallic outer jacket and integrated light-conducting optics |
| Heating Configuration | Dual-channel, three-zone furnace with 16-segment programmable ramp/soak profiles |
| Gas Flow Control | Three independent mass flow controllers (500/200/200 mL/min, 4–100% FS, ±1% FS accuracy) |
| Liquid Flow Rate | 0.001–4.999 mL/min (water-compatible) |
| Preheating Temp Range | 50–400 °C (16-segment program) |
| Trace Heating | 150–240 °C |
| Total System Volume | ~1.2 L |
| Dual Separation Vessels | 350 mL each (max 300 mL liquid holdup per vessel) |
| Dimensions | 1300 × 700 × 1800 mm |
| Power Supply | 220 V AC / 32 A, ≤6.5 kW (including light source) |
| Interface | Metric 3 mm Swagelok®-compatible fittings |
| Brand | PerfectLight (PoFeiLai) |
|---|---|
| Origin | Beijing, China |
| Model | PLR STPRS-O3 |
| Tracking Actuation | Photoelectric Auto-Tracking & Manual Override |
| Pan Range | 0–210° (adjustable reference) |
| Tilt Range | 0–90° |
| Reactor Active Area | 250 × 250 mm |
| Optical Window | Ultra-White Glass |
| Diffuser Plate | Frosted Glass |
| Adjustable Liquid Layer Thickness | 3 mm |
| Tubing Dimensions | 4 × 6 mm (ID × OD) |
| Operating Pressure Range | −60 to +20 kPa (with automatic pressure relief >20 kPa) |
| Reaction Vessel Materials | Borosilicate Glass, Fluoropolymer (FEP/PFA), Silicone Elastomer, 316 Stainless Steel |
| Liquid Reservoir Volume | ~300 mL |
| Gas Flow Measurement | Standard Mass Flow Controller (H₂, 0–20 sccm) |
| Liquid Flow Control | Rotameter (0–1 L/min), recommended ≥100 mL/min |
| Gas Inlet Pressure Limit | <0.1 MPa |
| Ambient Operation Temperature | 15–35 °C |
| Brand | PerfectLight |
|---|---|
| Model | PLR-100 |
| Reactor Type | Plate-type microchannel continuous flow photoreactor |
| Light Source Wavelength Range | 255–760 nm (multi-wavelength selectable) |
| Light Source Geometry | Planar LED array |
| Light Source Lifetime | >10,000 h |
| Adjustable Unit Power | 10–120 W |
| Temperature Control Range | −20 to +80 °C |
| Reaction Volume per Channel | 5 mL or 10 mL (configurable) |
| Reaction Phases Supported | Gas–liquid, liquid–liquid, liquid–solid |
| Gas–Liquid Channel Configuration | 3 liquid channels + 1 dedicated gas channel |
| Liquid Flow Rate Range | 1.5–8.5 mL/min |
| Gas Flow Rate Range | 4–20 mL/min |
| Flow Regime | Taylor (slug) flow optimized for interfacial mass transfer |
| In-line Monitoring | Fiber-optic UV-Vis spectrometer for real-time effluent absorbance profiling |
| Dimensions (W × D × H) | 810 × 600 × 500 mm |
| Compliance | Designed for lab-scale process intensification under GLP-aligned operation |
| Brand | PerfectLight (PofeiLai) |
|---|---|
| Origin | Beijing, China |
| Model | PLR-HGPR |
| Temperature Range | Ambient +10 °C to 300 °C (up to 380 °C) |
| Operating Pressure | 1–10 MPa |
| Reactor Volume | 50 mL (customizable: 25 mL or 100 mL) |
| Gas Inlets | 3 independent channels |
| Total Gas Flow Rate | 1–60 mL/min |
| Safety Relief Valve Setpoint | Adjustable up to 7 MPa |
| Gas Mixing Chamber Volume | 1 L |
| Flow Monitoring | Electronic soap-film flowmeter (10–60 mL/min range) |
| Optical Window | Thick fused-silica quartz, broadband transmission (190–2500 nm) |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR-HGPR |
| Temperature Range | Ambient +10 °C to 300 °C (up to 380 °C) |
| Operating Pressure | 1–10 MPa |
| Reactor Volume | 50 mL (customizable: 25 mL or 100 mL) |
| Gas Inlets | 3 independent channels |
| Total Gas Flow Rate | 1–60 mL/min |
| Safety Relief Valve Setpoint | Adjustable up to 7 MPa |
| Gas Mixing Chamber Volume | 1 L |
| Flow Monitoring | Electronic soap-film flowmeter (10–60 mL/min range) |
| Optical Window | Thick fused-silica quartz, transmission range: 190–2500 nm |
| Pressure & Temperature Display | Integrated digital panel meters |
| Enclosure | Integrated safety-rated protective cabinet |
| Brand | PerfectLight (Perfetlight) |
|---|---|
| Origin | Beijing, China |
| Model | PLR-HTSR |
| Heating Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.5 °C |
| Max Working Pressure (gauge) | 0–1.6 MPa |
| Reactor Volume (gas phase) | ~18 mL (integral mode: ~27 mL |
| differential mode | ~35 mL) |
| Liquid Fill Capacity | ≤6.5 mL |
| Reactor Body Material | 304 Stainless Steel |
| Optical Window | Sapphire, Ø30 mm, >90% Transmittance in UV-Vis-NIR (200–2500 nm) |
| Gas Inlet/Outlet Fitting | Standard Ø3 mm Swagelok-compatible Compression Fitting |
| Heating Element | Embedded Ni-Chrome Resistive Heater on 96% Al₂O₃ Ceramic Substrate |
| Temperature Sensor | Integrated K-Type Thermocouple with PID Feedback Control |
| Catalyst Support Options | Quartz Fiber Membrane (Ø37–50 mm, active area Ø35 mm), SiC Porous Ceramic Disc |
| Internal Insulation | Glass Fiber–Phenolic Resin Composite |
| Sealing | Fluoroelastomer (FKM) O-Ring |
| Brand | PerfectLight (PerfekLight) |
|---|---|
| Origin | Beijing, China |
| Model | PLR-PTSR II |
| Reaction Pressure | 1.6 MPa (gauge) |
| Maximum Reaction Temperature | 550 °C |
| Catalyst Bed Volume | 12 mL |
| Reactor Material | 304 Stainless Steel |
| Optical Window Transmission Range | 0.19–5 μm |
| Optical Window Diameter | Ø35 mm |
| Gas Volume (Differential Mode) | ~35 mL |
| Gas Volume (Integral Mode) | ~27 mL |
| Liquid Loading Capacity | ≤1.5 mL |
| Catalyst Forms | Powder-on-membrane or porous disc (Ø51 mm, ≤5.5 mm thick) |
| Membrane Support Size | Ø37–Ø50 mm, effective area ≥Ø35 mm |
| Mass Flow Control Range | 3–60 mL/min, ±1% FS |
| Pressure Control Range | 0.3–1.6 MPa (gauge), ±0.25% FS |
| Temperature Control Range | Ambient to 550 °C (N₂), resolution ±0.1 °C |
| Heating Modes | Electric, Photoirradiation, or Coupled Photothermal |
| Temperature Program | Up to 8 segments (isothermal, constant-power, or ramped profiles) |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR-PTSRⅡ |
| Reactor Type | Flow-through / Batch-integrated Photothermal Reactor |
| Volume | 18 mL (gas phase, sealed mode) |
| Max Operating Pressure | 1.6 MPa (gauge) |
| Max Temperature | 550°C (N₂ atmosphere) |
| Material | 304 Stainless Steel |
| Optical Window | Ø35 mm, Transmission Range: 0.19–5 μm |
| Gas Flow Control Range | 3–60 mL/min, ±1% F.S. |
| Pressure Control Range | 0.3–1.6 MPa |
| Temperature Control Resolution | ±0.1°C |
| Catalyst Format | Powder-on-membrane or porous disc (Ø51 mm, ≤5.5 mm thick) |
| Humidification Capability | Yes, liquid water injection supported |
| Heating Modes | Electrical, Photoirradiation (Xe lamp compatible), or Coupled Photothermal |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR-QY1000 |
| Light Source | 405 nm Laser Diode (standard), optional wavelengths available |
| Reaction Volume | ~150 mL internal headspace (calibration-dependent) |
| Liquid Sample Volume | 100 mL (adjustable range) |
| Pressure Range | 20–130 kPa (absolute) |
| Purge Gas | N₂, delivery pressure 0.4–0.45 MPa |
| Purge Cycles | 0–255 programmable |
| Residual O₂ | ≤100 ppm after purge |
| Stirring Speed | 250–1250 rpm |
| Temperature Control | 0–60 °C (via external circulating chiller) |
| Humidity & Temperature Monitoring | Integrated in-situ sensors |
| Quantum Yield Range | 0.05%–100% |
| Data Export | USB flash drive interface |
| Compliance | Designed for ISO/IEC 17025-aligned photocatalytic testing workflows |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLR-QY1000 Quantum Yield Measurement System |
| Temperature Range | 0–60 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Reaction Vessel Count | 1 |
| Reaction Volume Capacity | 100 mL |
| Light Source | 405 nm Laser Diode (Standard), Optional Wavelengths Available |
| Operating Pressure Range | 20–130 kPa |
| Gas Purge Pressure | 0.4–0.45 MPa (N₂) |
| Purge Cycles | 0–255 |
| Residual Oxygen Level | ≤100 ppm |
| Stirring Speed | 250–1250 rpm |
| Measurable Quantum Yield Range | 0.05%–100% |
| Internal Environmental Monitoring | Integrated Temperature & Relative Humidity Sensors |
| Cooling Interface | External Circulating Water Connection |
| Data Export | USB Flash Drive Interface |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR-SPRL |
| Effective Illuminated Area | 10×10 cm² (configurable: 5×5, 15×15, 20×20, 25×25 cm²) |
| Liquid Layer Thickness | 1–5 mm (customizable) |
| Reactor Angle Adjustment | 0–90° continuous |
| Flow Rate (Liquid) | 0–1 L/min |
| Carrier Gas Flow | 4–100 mL/min |
| Operating Temperature | Ambient to 60 °C |
| Operating Pressure | Atmospheric (sealed mode up to 50 kPa) |
| Circulating Gas Pump Flow | 1–1.5 L/min |
| Wetted Materials | PA66, PMMA, PP, Fluoroelastomer |
| Brand | PerfectLight (PoFeiLai) |
|---|---|
| Origin | Beijing, China |
| Model | PLR-STR05O |
| Reactor Effective Illuminated Area | >0.5 m² |
| Concentration Ratio | ≤5 |
| Reactor Specification | DN50 borosilicate glass tube, length >1000 mm |
| Operating Pressure | Ambient with micro-positive pressure (5–10 kPa) |
| Gas–Liquid Separation | Integrated |
| Storage Tank Volume | 10 L |
| Irradiance Monitoring | 0–1200 W/m² (at reactor plane) |
| pH Range | 1–14, accuracy ±0.02 |
| ORP Range | −2000 to +2000 mV, accuracy ±15 mV |
| Flow Rate Monitoring | 3–60 L/min, accuracy ±3 L/min |
| Temperature Monitoring | 0–80 °C, accuracy ±1 °C |
| Environmental Sensors | Wind speed, ambient temperature/humidity/pressure |
| Flow Control | Variable-frequency pump (0–60 L/min, head >10 m) |
| Azimuth Tracking Range | ±70° |
| Elevation Adjustment Range | 0–50° (manual) |
| Safety Alarms | Wind speed, temperature, and angle limits |
| Data Logging | Real-time acquisition with automated report generation |
| Structural Wind Resistance | Grade 6 (IEC 61400-1 compliant) |
| Enclosure Rating | IP65 |
| Mobility | Modular, ground-mountable or mobile base compatible |
| Human–Machine Interface | 7-inch PLC touchscreen + PC-based control software |
| Brand | SHNTI |
|---|---|
| Origin | Shanghai, China |
| Model | PMT |
| Load Capacity | Up to 300 kg |
| Vibration Control Principle | Real-time active force cancellation via triaxial inertial sensing and pneumatic actuation |
| Noise Attenuation | Broadband airborne noise isolation via multilayer acoustic barrier construction |
| Magnetic Shielding | Integrated mu-metal and conductive layer shielding |
| Control Architecture | Hybrid feedforward + feedback control |
| Compliance | Designed for GLP-compliant environments |
| Software Interface | Embedded LED status display |
| Brand | PofeiLai (PerfectLight) |
|---|---|
| Origin | Beijing, China |
| Model | PQ Series Laboratory-Scale Photoreactor |
| Construction Material | JGS-2 Fused Quartz |
| Optical Window Options | Quartz Flat Plate (Φ110 × 8 mm) or Quartz Jacketed Window |
| Total Volume | ~350 mL |
| Effective Reaction Volume | ~150 mL |
| Sealing Method | Flanged Connection with Viton/FFKM O-Ring Seal |
| Standard Ground Joints | Two 19/26 taper joints |
| Integrated Features | Gas Inlet/Outlet Ports for Atmosphere Control, Manual Sampling Port with Septum Penetration, Optional Vacuum/Reagent Addition Port, Optional Thermostatic Water Jacket |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory use |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NGB-R |
| Price Range | USD 280,000 – 700,000 |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NGB-R |
| Price Range | USD 270,000 – 680,000 |
| Brand | Polycold |
|---|---|
| Origin | USA |
| Model | MAXCOOL 2500 L |
| Maximum Load | 2500 W |
| Operating Temperature Range | –120 °C to –145 °C |
| Water Vapor Pumping Speed (actual) | 140,000 L/s |
| Ultimate Vacuum | 1 × 10⁻⁹ mbar |
| Starting Pressure | ≤1 atm |
| Defrost Time | 4.0 min |
| Cold Surface Area | 1.4 m² |
| Cooling Water Flow Rate (at 13 °C ΔT) | 13.6 L/min |
| Noise Level (max) | 68 dB(A) |
| Footprint (min) | 0.403 m³ |
| Weight | 544 kg |
| Compliance | CE, UL Listed, RoHS Compliant |
| Brand | Polycold |
|---|---|
| Origin | USA |
| Model | MaxCool 4000 H |
| Cooling Method | Water-Cooled |
| Circulating Pump Pressure | 7 × 10⁻⁸ mbar |
| Refrigeration Capacity | 4000 W |
| Condensing Surface Area | 2.2 m² |
| Cold Trap Tube Diameter | 16 mm |
| Single-Loop Tube Length | 43 m |
| Dual-Loop Tube Length | 2 × 21.9 m |
| Standard Cold Finger Length | 2.44 m |
| Cooling Water Flow Rate (at ΔT = 13°C/26°C/29°C) | 13.6 / 27.3 / 54.1 L/min |
| Noise Level | ≤78 dB(A) |
| Dimensions (Min. Footprint) | 34 m³ |
| Weight | 533 kg |
| Brand | Polycold |
|---|---|
| Origin | USA |
| Model | MaxCool Series |
| Cooling Principle | Meissner Absorption Cycle |
| Refrigerant | Proprietary Non-Toxic, Recyclable Cryogenic Fluid |
| Ultimate Vacuum | 4×10⁻⁸ to 1×10⁻⁹ mbar |
| Maximum Condensing Load | 4000 W |
| Water Vapor Pumping Speed | Up to 220,000 L/s |
| Mounting | Direct Integration into Vacuum Chamber via Custom Cryocoil |
| Compliance | Designed for ISO/IEC 17025-aligned vacuum system integration |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PB1 |
| Quotation | Available Upon Request |
| Bath Volume | 3.5 L |
| Temperature Range | Ambient +5°C to 60°C |
| Setpoint Range | 10°C to 60°C |
| Temperature Stability (DIN 58966) | ±0.3°C at 37°C |
| Control Method | Analog Dial Control |
| Power Supply | 120 V or 230 V AC |
| Heating Power | 0.3 kW |
| External Dimensions (L×W×D) | 225 × 120 × 80 mm |
| Safety Feature | Fixed-Temperature Cut-Off (DIN 12876 Compliant) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 12122-04 |
| Instrument Type | Circulating Water/Oil Bath |
| Circulation Mode | Internal Only |
| Temperature Control | Dual-mode (Cooling & Heating) |
| Bath Capacity | 15 L |
| Temperature Range | −20 °C to +100 °C |
| Temperature Stability | ±0.1 °C at ambient |
| Pump Flow Rate | 15 L/min |
| Refrigerant | R-134a |
| Sensor | Pt100 Platinum Resistance Thermometer |
| Controller | PID with LCD Display & Touch Keypad |
| Safety Features | High/Low Temp Limit Setpoints, Dry-run Protection, Auto Shut-off at Over-Temp |
| Power Supply | 230 V, 50 Hz |
| Heating Power | 1200 W |
| Cooling Power | 250 W |
| Internal Dimensions (L×W×D) | 17.3 × 15 × 18.3 cm |
| External Dimensions (L×W×D) | 26 × 65 × 49 cm |
| Key Features | Stainless steel reservoir |
|---|---|
| Temperature range | ambient to +100 °C |
| Stability | ±0.1 °C across full range |
| Brand | Polytech |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM Manufacturer |
| Model | Automated SPE 606S |
| Pricing | Upon Request |
| Sample Volume Range | 0.1 mL to unlimited (with particulate tolerance) |
| Channels | 6 independent parallel channels |
| Cartridge Compatibility | 1 mL, 3 mL, 6 mL, 12 mL SPE cartridges |
| Disk/Cartridge Configurations | Cartridge–cartridge, disk–disk, cartridge–disk serial setups |
| Solvent Channels | Up to 9 reagents |
| Elution Solvent Delivery | Precision syringe pumps |
| Sample Loading Pumps | Peristaltic metering pumps (6-channel simultaneous loading) |
| Concentration Mode | 6-channel independent nitrogen blow-down with liquid-level sensing |
| Control Interface | 5-inch 65K-color capacitive touchscreen |
| Data Storage | SD card-based method storage and transfer |
| Compliance Standards | GB/T 20466–2006, GB/T 5750.8–2006, HJ 478–2009, HJ 648–2013, HJ 753–2015, GB/T 21925–2008, CJ/T 141–2001, CJ/T 146–2001, CJ/T 147–2001 |
| Brand | Polytech |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Graphite Block Digestion System |
| Automation Level | Fully Automated |
| Digestion Positions | 30 × 50 mL + 16 × 100 mL (configurable modular layout) |
| Max Heating Temperature | 230 °C |
| Temperature Uniformity | High spatial uniformity across graphite block |
| Reagent Channels | 8 independent peristaltic pump-driven channels |
| Sample Processing Workflow | Automated reagent addition, mixing, temperature-programmed digestion, acid evaporation (dry-down), cooling, and final volumetric定容 via ultrasonic sensor-based precision dispensing |
| Brand | Polytech |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | EVA08 |
| Pricing | Available upon Request |
| Brand | Polytech |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | EVA32 |
| Price | USD 8,400 (FOB Anhui) |
| Brand | Polytech |
|---|---|
| Model | HPSE-06 |
| Extraction Channels | 6 parallel |
| Temperature Range | Ambient to 210 °C (±1 °C control accuracy) |
| Pressure Range | 0–20 MPa |
| Pump Flow Rate | 0–100 mL/min |
| Maximum Pump Output Pressure | 26 MPa |
| Solvent Selection | Quaternary solvent system with programmable mixing ratios |
| Extraction Cell Volumes | 5, 10, 34, 40, 66, 80, 100, 120 mL (customizable) |
| Cell Material | Electropolished stainless steel or specialty alloy with PTFE seals |
| Collection Vial Capacity | 60–250 mL |
| Safety Systems | Integrated pressure regulation, overpressure cutoff, gas–liquid isolation protection |
| Interface | Bilingual (Chinese/English) graphical LCD with real-time extraction profile visualization, self-diagnostic capability, and automated nitrogen/solvent purge cycles |