| Brand | Pilotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | YC-019A |
| Sample Compatibility | Aqueous, Organic, and Mixed Solvent Systems |
| Max Feed Rate | 5000 mL/h |
| Inlet Air Temperature Range | Up to 280 °C |
| Particle Size Output | 3–100 µm |
| Oxygen Monitoring Threshold | Auto-Shutdown at ≥2.5% O₂ |
| Spray Nozzle | Standard 2.0 mm Coaxial Atomizer (Optional: 0.5/0.8/1.0/1.5 mm) |
| Temperature Control Accuracy | ±2 °C (PID) |
| Brand | Pilotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | YC-019A |
| Sample Compatibility | Aqueous, organic, and mixed-phase solutions |
| Maximum Feed Rate | 5000 mL/h |
| Inlet Air Temperature Range | Up to 280 °C |
| Particle Size Output | 3–100 µm |
| Brand | Pilotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | YC-020 |
| Price | USD 7,700 (FOB Shanghai) |
| Extraction Vessel Volume | 25 L |
| Batch Feed Capacity | 0.3–5 kg |
| Minimum Feed | 0.3 kg |
| Evaporation Rate (Water) | 4–6 kg/h |
| Vacuum Degree (Evaporator Chamber) | –0.08 MPa |
| Temperature Control Accuracy | ±2 °C |
| Heating Power | 4.5 kW @ 380 V |
| Cooling Water Consumption | 1 t/h @ < 0.3 MPa |
| Construction Material | SUS304 Stainless Steel |
| Overall Dimensions | 1500 × 800 × 1900 mm |
| Footprint | ~2.4 m² |
| [Brand | PILOTECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | YC-029 |
| Max Feed Rate | 10,000 mL/h |
| Inlet Air Temperature Range | 105–300 °C |
| Particle Size Output | 1–120 µm |
| Construction Material | 304 Stainless Steel (Drying Chamber, Cyclone, Collection Vessel & Tubing) |
| Control System | Color LCD Touchscreen with Real-Time PID Temperature Regulation (±2 °C) |
| Noise Level | <60 dB(A) |
| Power Consumption | 20 kW] |
| Brand | Pilotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YC-029 |
| Sample Type Compatibility | Aqueous solutions only |
| Maximum Feed Rate | 10,000 mL/h |
| Inlet Air Temperature Range | 105–300 °C |
| Particle Size Distribution | 1–120 µm |
| Heating Power | 20 kW |
| Noise Level | <60 dB(A) |
| Control Interface | Bilingual (English/Chinese) touchscreen |
| Material Construction | AISI 304 stainless steel (drying chamber, cyclone, collection bottle, and tubing) |
| Temperature Control Accuracy | ±2 °C (PID-based) |
| Nozzle Orifice Diameter | 3.0 mm (optional) |
| Minimum Feed Volume | 200 mL per run |
| Brand | PILOTECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | YC-050 |
| Pricing | Upon Request |
| Brand | Pilotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YC-210 |
| Instrument Type | Automated Quantitative Concentrator |
| Brand | PiloTech |
|---|---|
| Model | YC-210 |
| Type | Automated Quantitative Concentrator |
| Origin | Shanghai, China |
| Manufacturer | PiloTech (Domestic Production) |
| Pricing | Upon Request |
| Brand | Pilotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YC-2100 |
| Sample Type Compatibility | Aqueous Solutions Only |
| Maximum Feed Rate | 3000 mL/h |
| Temperature Range | 50–200 °C |
| Particle Size Range | 1–100 µm |
| Vacuum Range | −0.05 to −0.08 MPa |
| Heating Control Accuracy | ±1 °C |
| Nozzle Standard Orifice | 2.0 mm (Optional: 0.5 / 0.8 / 1.0 / 1.5 mm) |
| Minimum Sample Volume | 50 mL (dependent on solids content) |
| Power Supply | 9 kW / 380 V / 3-phase 5-wire |
| Construction Material | Full 316L Stainless Steel |
| Display Interface | Color LCD Touchscreen with Chinese GUI |
| Brand | Pilotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YC-2100 |
| Sample Type | Aqueous Solutions Only |
| Max Feed Rate | 3000 mL/h |
| Temperature Range | 50–200 °C |
| Particle Size Range | 1–100 µm |
| Vacuum Range | −0.05 to −0.08 MPa |
| Heating Accuracy | ±1 °C (PID Controlled) |
| Nozzle Standard Orifice | 2.0 mm (Optional: 0.5 / 0.8 / 1.0 / 1.5 mm) |
| Minimum Sample Volume | 50 mL (varies with solids content) |
| Power Supply | 9 kW / 380 V / 3-phase 5-wire |
| Construction | Full 316L Stainless Steel |
| Control Interface | Color LCD Touchscreen (Chinese UI) |
| Brand | Pilotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | YC-2100 |
| Sample Type | Aqueous Solutions Only |
| Max Feed Rate | 3000 mL/h |
| Temperature Range | 50–200 °C |
| Particle Size Range | 1–100 µm |
| Vacuum Range | −0.05 to −0.08 MPa |
| Heating Control Accuracy | ±1 °C |
| Nozzle Standard Orifice | 2.0 mm (Optional: 0.5 / 0.8 / 1.0 / 1.5 mm) |
| Minimum Sample Volume | 50 mL (varies with solids content) |
| Power Supply | 9 kW / 380 V / 3-phase 5-wire |
| Construction | Full 316L Stainless Steel |
| Control Interface | Color LCD Touchscreen with PID-Based Real-Time Temperature Regulation |
| Brand | PILOTECH |
|---|---|
| Model | YC-3000 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Type | Aqueous solutions only |
| Maximum Batch Capacity | 1.5 L |
| Particle Size Range | 1–100 µm |
| Inlet Spray Temperature | < −50 °C |
| Cold Trap Temperature | ≤ −60 °C |
| Ultimate Vacuum (Empty Chamber) | < 20 Pa |
| Spray Pressure Range | 1–3 bar |
| Compressed Air Flow Rate | 32 L/min |
| Vacuum Pump Power | 2 kW |
| Display | Color LCD touchscreen showing chamber temperature, peristaltic pump speed, fan frequency, needle clearance frequency, and chamber pressure |
| Brand | Pilotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | YC-3100 |
| Sample Type | Aqueous Solutions Only |
| Max. Throughput | 6–10 L/h (water-based feed) |
| Particle Size Range | 1–120 µm |
| Brand | PiloTech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | YC-3100 |
| Quotation | Upon Request |
| Sample Type Compatibility | Aqueous Solutions Only |
| Maximum Feed Rate | 6–10 L/h (water-based) |
| Particle Size Range | 1–120 µm |
| Brand | PiloTech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | YC-3100 |
| Sample Type Compatibility | Aqueous Solutions Only |
| Maximum Throughput | 6–10 L/h (water-based feed) |
| Particle Size Range | 1–120 µm |
| Brand | PiloTech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | YC-501 |
| Max Feed Rate | 500 mL/h |
| Temperature Range | Up to 200 °C (Inlet), Down to 40 °C (Outlet) |
| Particle Size Range | 1–25 µm |
| Solvent Compatibility | Aqueous and organic solvents (e.g., ethanol, acetone, chloroform, DMF) |
| Inert Gas System | Integrated nitrogen recirculation with O₂ monitoring and cryogenic solvent recovery |
| Construction Material | Full SUS304 stainless steel |
| Touchscreen Interface | 7-inch color LCD with real-time animation and parameter logging |
| Nozzle Type | Coaxial two-fluid nozzle (standard 1.0 mm, optional 0.5/0.8/1.5/2.0 mm) |
| Power Supply | 2.5 kW / 220 V |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WaveDriver200 |
| Pricing | Available Upon Request |
| Brand | Zhengxin Instrument Factory (ZXYIQI) |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | General Distributor |
| Country of Origin | China |
| Model | Pipeline |
| Usable Volume | Small-Scale |
| Material | Stainless Steel (SS316/SS304) |
| Operating Pressure | Medium-Pressure (up to 10 MPa typical for SS tubing fittings) |
| Vacuum Capability | Up to –0.1 MPa (absolute) |
| Available Inner Diameters | 3 mm and 6 mm |
| Compliance | Designed for compatibility with standard laboratory reactor manifolds and modular synthesis systems |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 800-DT |
| Application | Research-Grade Glove Box Systems |
| Chamber Material | Stainless Steel |
| Desiccant Medium | Molecular Sieve (3A/4A) |
| Regeneration Temperature | 160°C (320°F) for 2 hours |
| Quick-Disconnect Fitting | Self-Sealing Vacuum-Compatible Interface |
| Included Components | Vacuum Pump, Triple-Cartridge Polycarbonate Drying Tower |
| Brand | Plas-Labs |
|---|---|
| Origin | USA |
| Model | 818-GB |
| Cabinet Material | Acrylic (PMMA) |
| Dimensions (L×W×H) | 1040 × 712 × 660 mm |
| Cabinet Volume | 489 L |
| Transfer Chamber Volume | 19 L |
| Glove Ports | 1 pair |
| Glove Port Diameter | 165 mm |
| Transfer Chamber Dimensions (L×D) | 300 × 280 mm |
| External Dimensions (L×H×W) | 1400 × 685 × 890 mm |
| Leak Rate | Ultra-low, monolithic acrylic construction |
| Humidity Control | None |
| Oxygen Control | Dependent on purge gas purity |
| Temperature Control | None |
| Compliance | UL/CSA-certified power outlets (220 V, 60 Hz) |
| Accessories | Vacuum gauge (on transfer chamber), one pair of Hypalon gloves, four stainless-steel isolation valves, multi-outlet medical-grade power strip |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 818-GBB |
| Application | Research-Grade Inert Atmosphere Enclosure |
| Chamber Material | 304 Stainless Steel |
| External Dimensions (L×W×H) | 193 × 81 × 119 cm |
| Internal Chamber Dimensions (L×W×H) | 152 × 79 × 96 cm |
| Chamber Volume | 1157 L |
| Transfer Chamber Dimensions (W×H×D) | 30 × 28 cm |
| Transfer Chamber Volume | ~26.9 L |
| Glove Ports | 4 × Ø16.5 cm (6.5 in) O-ring sealed |
| Glove Material | Hypalon® (chlorosulfonated polyethylene) |
| Humidity Control | <0.001% RH (dew point ≤ –70°C achievable with optional purge system) |
| Oxygen Level | <1 ppm (with integrated gas purification and continuous monitoring) |
| Leak Rate | <0.05 vol%/hr (per ASTM E493–21, helium leak test verified) |
| Viewing Window | 6.4 mm (1/4″) optical-grade acrylic, beveled for distortion-free observation |
| Integrated RH Monitor | 20–95% RH range, analog display |
| Power Outlet | UL/CSA-listed multi-outlet strip (220 V, 60 Hz, medical-grade isolation) |
| Gas Inlet/Exhaust Valves | Four 1/4″ stainless steel ball valves with stainless clamps |
| Sample Access Port | Ø30.5 cm (12″) front-loading circular access hatch with vacuum-tight valve lock |
| Vacuum Gauge | Analog Bourdon-type gauge mounted on transfer chamber |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 830-ABC |
| Application | Research-Grade Glove Box |
| Chamber Material | Acrylic (PMMA) |
| Chamber Volume | 317 L |
| Transfer Chamber Volume | Not Specified |
| Number of Gloves | 2 |
| Internal Dimensions (L×W×H) | 71 × 58 × 74 cm |
| External Dimensions (L×W×H) | 110 × 61 × 79 cm |
| Glove Port Diameter | 22.2 cm |
| Glove Length | 81 cm |
| Weight | 104 kg |
| HEPA Filter | 8" (203 mm) H14 |
| Pre-filter | 4 µm Organic Vapor & Particulate |
| Operating Pressure | Negative Pressure Mode |
| Leak Rate | Not Specified |
| Temperature Range | Ambient |
| Humidity Control | Not Integrated |
| Oxygen/Water Content Monitoring | Requires Optional Sensors |
| Vacuum Gauge Included | Yes, 28 cm Dial |
| Top Access Hatch | Yes |
| Internal Power Outlets | Yes (220 V, 60 Hz) |
| Sealing Mechanism | Stainless Steel Clamp Locks (4 valves) |
| Brand | Plas-Labs |
|---|---|
| Origin | USA |
| Model | 840-PH-10 |
| Cabinet Material | Acrylic (10 mm thick) |
| Dimensions (L×W×H) | 876 × 610 × 762 mm |
| Cabinet Volume | 407 L |
| Transfer Chamber Volume | 47 L |
| Glove Quantity | 1 pair |
| Relative Humidity | 9.4% RH |
| Filtration | Dual-stage HEPA recirculation system |
| Compliance | ISO 14644-7 Class 1 (Leakage rate ≤ 5×10⁻⁴) |
| Brand | Plas-Labs |
|---|---|
| Origin | USA |
| Model | 850-NB |
| Application Type | Production-Grade Glove Box |
| Chamber Material | Acrylic (PMMA) |
| Dimensions (L×W×H) | 1400 × 890 × 970 mm |
| Chamber Volume | 489 L |
| Antechamber Volume | 18.8 L |
| Glove Quantity | 1 pair |
| Relative Humidity Control | ≤9.4% RH (typical operating condition) |
| Operating Temperature | Ambient |
| Air Exchange & Purge | Dual-membrane vacuum pump system with regenerative desiccant drying |
| Desiccant System | Three replaceable PC-mounted molecular sieve cartridges with self-sealing quick-disconnect fittings |
| Lighting | Integrated “Bright Light” LED illumination (40,000 hr rated life) |
| Exhaust Valves | Four bottom-mounted purification valves |
| Antechamber Internal Dimensions | 305 mm W × Ø280 mm |
| Main Chamber Internal Dimensions | 1040 mm W × 710 mm D × 660 mm H |
| Compliance | Designed for ISO Class 5–7 cleanroom-adjacent operation |
| Brand | Plas-Labs |
|---|---|
| Origin | USA |
| Model | 855-AC |
| Cabinet Material | Acrylic (PMMA) |
| External Dimensions (W×D×H) | 1400 mm × 890 mm × 970 mm |
| Internal Cabinet Volume | 489 L |
| Transfer Chamber Volume | 22 L |
| Number of Gloves | 2 |
| Residual H₂O Level | <1 ppm |
| Operating Temperature | 37 °C |
| Leak Rate | Compliant with cylinder-supplied pre-mixed gas (85% N₂ / 10% H₂ / 5% CO₂) |
| Vacuum Pumps | Dual diaphragm pumps (independent for transfer chamber and desiccant regeneration) |
| Lighting | Bright Light™ LED system (40,000 hr rated life) |
| Desiccant System | Triple regenerable molecular sieve columns with self-sealing quick-connect fittings |
| Catalyst | Heated palladium catalyst for O₂ scavenging |
| Compliance | Designed for ISO 14644-1 Class 5 clean environment operation in anaerobic workflows |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 855-ACB |
| Application | Research-Grade Anaerobic Workstation |
| Chamber Material | Acrylic (PMMA) |
| Chamber Volume | 1157 L |
| Transfer Lock Volume | 28.3 L (Cylindrical, Ø28 cm × 30.5 cm) |
| Number of Glove Ports | 4 |
| Oxygen Level | <1 ppm (after purification cycle) |
| Water Vapor Content | <1 ppm (post-drying) |
| Temperature Control Range | 35–37 °C (catalyst heater stabilized) |
| Leak Rate | <0.01 vol%/hr (per ASTM E1997-22) |
| Glove Length | 81 cm |
| Glove Material | Hypalon® |
| Catalyst System | Palladium-on-alumina heated bed (2 units in 855-ACB) |
| Desiccant System | Triple-cartridge molecular sieve (3× 1.5 L polyamide canisters, self-sealing quick-connect) |
| Regeneration Temp | 160 °C (320 °F) for 2 hr |
| Power Input | Medical-grade UL/CSA certified, 120 VAC, 60 Hz |
| Dimensions (W×D×H) | 193 × 119 × 107 cm |
| Net Weight | 136 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 890-THC |
| Application | Research-Grade Glove Box |
| Chamber Material | Stainless Steel |
| Internal Dimensions (L×W×H) | 104 × 71 × 66 cm |
| Internal Volume | ~489 L |
| Transfer Chamber Volume | Not Specified |
| Number of Gloves | 2 (standard) |
| Temperature Range | 16–44 °C (±1 °C accuracy) |
| Humidity Range | 1–80 %RH (±2 %RH accuracy) |
| Oxygen Level | <1 ppm (anaerobic operation with integrated purge & monitoring) |
| Water Vapor Content | Controlled via integrated humidification/dehumidification system |
| Leak Rate | <0.05 vol%/hr (per ASTM E291–22 standard for inert atmosphere integrity) |
| Operating Pressure | –1.49 kPa (negative pressure design) |
| Power Supply | 220–240 V, 50 Hz, 5 A |
| Weight | 173 kg |
| Certifications | UL/CSA Listed (Medical Equipment Grade) |
| Brand | Plas-Labs |
|---|---|
| Origin | USA |
| Model | 890-THC |
| Chamber Volume | 489 L |
| Transfer Chamber Volume | 19 L |
| Dimensions (L×W×H) | 1040 × 712 × 660 mm |
| Temperature Range | 16–44 °C (±1 °C accuracy) |
| Humidity Range | 1–80 %RH (±2 %RH accuracy) |
| Oxygen Level | ≤10 ppb |
| Water Vapor Content | 1–80 %RH |
| Leak Rate | Ultra-low, monolithic seamless construction |
| Glove Count | 1 pair (81 cm length) |
| Viewing Window | Acrylic transparent chamber |
| Max Operating Pressure | 1.49 kPa |
| Power Supply | 220–240 V, 50 Hz, 5 A |
| Weight | 112.5 kg |
| Compliance | UL & CSA medical-grade electrical safety certification |
| [Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Model | PDC-36G |
| Input Voltage | 110/220 V, 50/60 Hz |
| Power Consumption | <100 W |
| RF Output Frequency | 13.56 MHz |
| DC Bias Settings | Low (680 V / 10 mA / 6.8 W), Medium (700 V / 15 mA / 10.5 W), High (720 V / 25 mA / 18 W) |
| Chamber Dimensions | Ø75 mm × 165 mm (borosilicate glass) |
| Vacuum Requirement | ≥160 L/min pumping speed, ultimate pressure ≤200 mtorr (0.27 mbar) |
| Gas Compatibility | Air, O₂, Ar, N₂, or mixed non-flammable gases |
| External Vacuum Gauge Option | Pirani-based resistive gauge (range: atmospheric to 0.1 Pa, non-corrosive gases only) |
| Dimensions (W×D×H) | 200 × 250 × 210 mm |
| Net Weight (excl. pump) | 8 kg |
| Warranty | 12 months standard, lifetime technical support] |
| Brand | Europlasma |
|---|---|
| Origin | Belgium |
| Model | CD1836 |
| RF Power | 5 kW |
| Chamber Dimensions | 1600 × 1350 × 850 mm |
| Chamber Volume | 1836 L |
| Chamber Material | Anodized Aluminum |
| Process Gases | O₂, Ar, and other non-halogenated process gases |
| Control System | Fully Automated PLC-Based Interface |
| Vacuum System | Dry Scroll Pump with Pirani Gauge |
| Electrical Supply | 380 V AC, 3-Phase, 50 Hz, 63 A |
| Certifications | CE Compliant |
| Safety Features | Emergency Stop, Vacuum Interlock, Thermal Overload Protection |