| Brand | Auniontech (HaoLiang Optoelectronics) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model Series | SA108P, SA120P, SA217P, SA220P/SS-OCT, SA230P, SA240P/SS-OCT, SA248P |
| Sampling Rates | 1–8 GS/s |
| Resolution | 8-bit or 14-bit |
| Bandwidth | DC to 2.5 GHz |
| Input Range | 50 mV–5 V (configurable) |
| Onboard Memory | Up to 8 GB |
| Interface | PCIe 3.0 x8 |
| ENOB | 9-bit (8-bit models) |
| SFDR | 70 dBc (flat over analysis bandwidth) |
| Trigger Interpolation Accuracy | 15 ps RMS |
| Clock Jitter | 100 fs |
| Clock Accuracy | ±1 ppm |
| Brand | Auniontech (HaoLiang Optoelectronics) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SA248P |
| Application Focus | SS-OCT, LIDAR, Fiber Optic Sensing, Mass Spectrometry, Semiconductor Test |
| Interface | PCIe Gen2 x8 |
| Sampling Rate | 8 GS/s (single channel) |
| Resolution | 14-bit |
| Analog Bandwidth | 2.5 GHz |
| Input Impedance | 50 Ω, DC-coupled |
| Full-Scale Range | 1 V (selectable) |
| Input Offset Range | ±0.5 FSR |
| Onboard Memory | 4 GB or 8 GB |
| Real-Time Processing | FPGA-based hardware averaging (AVG), Clock & Synchronization Trigger (CST) output |
| Software Support | IVI-C, IVI.NET, C/C++, C#, VB.NET, MATLAB, LabVIEW, Linux |
| Compliance | Designed for GLP/GMP-aligned test systems |
| Key | Brand: Campbell |
|---|---|
| Origin | USA |
| Model | CR1000Xe |
| Operating Temperature (Standard) | -40 to +70°C |
| Operating Temperature (Extended) | -55 to +85°C |
| Analog Inputs | 16 single-ended or 8 differential, plus 2 dedicated 0–20 mA / 4–20 mA current inputs |
| ADC Resolution | 24-bit |
| Max Scan Rate | 100 Hz |
| Communication Interfaces | Ethernet, USB Micro-B, RS-232/RS-485/RS-422, CPI, CS I/O, SDI-12, I²C, SPI |
| Data Storage | 4 MB SRAM + 72 MB flash + microSD slot (up to 16 GB) |
| Power Input | 10–36 VDC |
| Real-Time Clock Accuracy | ±3 min/year (GPS optional for ±10 µs) |
| Enclosure | Anodized aluminum with RF-shielded stainless steel electronics housing |
| Dimensions | 23.8 × 10.1 × 6.2 cm |
| Weight | 0.86 kg |
| Brand | Campbell |
|---|---|
| Origin | USA |
| Model | CR300 |
| CPU | ARM Cortex-M4 @ 144 MHz |
| Internal Memory | 80 MB data storage, 5 MB program storage, 2 MB OS storage |
| Clock Accuracy | ±1 minute/month |
| USB Interface | Micro-B, USB 2.0 Full-Speed (12 Mbps) |
| Power Input | 12 V terminal or 12 V battery/UPS |
| Excitation Output | 1 × switched 12 V (500 mA @ 20°C) |
| Analog Inputs | Differential, ±34 mV range, 230 nV resolution, accuracy ±(0.04% of reading ± 6 µV) at 0°–40°C |
| Operating Temperature | –40° to +70°C |
| Dimensions | 14 × 7.6 × 5.1 cm |
| Weight | 242 g |
| Communication Protocols | PPP, ICMP/Ping, Auto-IP (APIPA), IPv6, UDP, TCP, TLS, DHCP Client, SLAAC, DNS Client, Telnet, PakBus, SDI-12, Modbus RTU/ASCII/TCP, DNP3 |
| Environmental Protection | High-level surge and ESD protection |
| Data Transmission | Encrypted email & alarm notifications via TLS |
| Configuration | USB direct-to-PC |
| Compliance | Designed for long-term unattended field deployment in hydrological, meteorological, environmental, and industrial monitoring applications |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR1000X |
| Operating Temperature Range | –40 to +70 °C (standard), –55 to +85 °C (extended) |
| Analog Inputs | 16 single-ended or 8 differential |
| ADC Resolution | 24-bit |
| Max Scan Rate | 100 Hz |
| Communication Interfaces | Ethernet, USB Micro-B, RS-232/RS-485/RS-422, CPI, SDI-12, PakBus, Modbus TCP/RTU, DNP3, MQTT, NMEA 0183, I²C, SPI |
| Real-Time Clock Accuracy | ±3 min/year (±10 µs with optional GPS synchronization) |
| Power Supply | 10–18 VDC |
| Idle Current Draw | <1 mA @ 12 VDC |
| Dimensions | 23.8 × 10.1 × 6.2 cm |
| Weight | 0.86 kg |
| Data Storage | 4 MB SRAM + 72 MB flash + microSD slot (up to 16 GB) |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR300 |
| Operating Temperature | -40 to +70 °C (standard, non-condensing) |
| Analog Inputs | 6 single-ended or 3 differential (software-configurable) |
| ADC Resolution | 24-bit |
| Analog Voltage Accuracy | ±(0.04% of reading + offset) at 0–40 °C |
| Pulse Counters | 8 (P_SW, P_LL, C1, C2, SE1–SE4) |
| Excitation Outputs | 2 (VX1, VX2) |
| Digital I/O | 7 configurable terminals (C1, C2, P_SW, SE1–SE4 |
| Communication Interfaces | USB Micro-B, RS-232, Ethernet (10/100BASE-T), PPP, RNDIS |
| Supported Protocols | PakBus, Modbus RTU/TCP, DNP3, SDI-12, TCP/IP, UDP, TLS v1.2, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS, NTP, DHCP, DNS, ICMP, IPv4/IPv6 |
| Real-Time Clock Accuracy | ±1 minute per month (battery-backed) |
| Power Supply | 16–32 Vdc (CHG input) |
| Idle Current Draw | 1.5 mA @ 12 Vdc |
| Active Current Draw | 5 mA @ 12 Vdc (1 Hz scan, 1 analog measurement) |
| Enclosure Material | Powder-coated aluminum |
| Dimensions | 13.97 × 7.62 × 4.56 cm (5.5 × 3.0 × 1.8 in.) |
| Weight | 242–250 g (0.53–0.55 lb) |
| Onboard Memory | 80 MB flash (program/storage), 30 MB dedicated data storage |
| Programming Language | CRBasic (onboard BASIC-like language) |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR3000 |
| Analog Input Channels | 28 single-ended (14 differential) |
| Analog Voltage Range | ±5000 mV |
| Analog Resolution | 0.33 µV |
| A/D Resolution | 16-bit |
| Maximum Scan Rate | 100 Hz |
| Pulse Count Channels | 4 |
| Switched Excitation Outputs | 4 voltage, 3 current |
| Control Ports | 3 SDM, 8 I/O |
| Communication Interfaces | CS I/O, RS-232, Ethernet (optional), RF radio (optional), CDMA/GPRS (optional), satellite (optional) |
| Supported Protocols | PakBus, Modbus RTU/ASCII/TCP, DNP3, FTP, HTTP, XML, POP3, SMTP, Telnet, NTP, NTCIP, SDI-12, SDM |
| Memory | 4 MB internal |
| Power Consumption | 2 mA (sleep), 3 mA (1 Hz), 10 mA (100 Hz) |
| Environmental Compliance | CE, EMC, GDT input protection |
| Real-Time Clock | Temperature-compensated, battery-backed |
| Data Storage Format | Tabular (timestamp + record number) |
| Operating Temperature | 0–40 °C |
| Software Compatibility | LoggerNet 3.4/4.0, PC400 1.2, ShortCut 2.2 |
| Brand | CAMPBELL |
|---|---|
| Origin | USA |
| Model | CR310 |
| Operating Temperature | -40 to +70°C (standard, non-condensing) |
| Scan Rate | Up to 10 Hz |
| Analog Inputs | 6 single-ended or 3 differential (user-configurable) |
| Pulse Counters | 8 (P_SW, P_LL, C1, C2, SE1–SE4) |
| Excitation Outputs | 2 (VX1, VX2) |
| Communication Interfaces | USB Micro-B, RS-232, 10/100 Base-T Ethernet (RJ45) |
| Digital I/O | 7 configurable terminals (C1, C2, P_SW, SE1–SE4 |
| ADC Resolution | 24-bit |
| Analog Accuracy | ±(0.04% of reading + offset) at 0–40°C |
| Power Input | 16–32 Vdc (CHG), 10–18 Vdc (BAT) |
| Typical Idle Current | 10 mA @ 12 Vdc (Ethernet link idle) |
| Active Current | 56 mA @ 12 Vdc (Ethernet active, CPU always on) |
| Enclosure | Powder-coated aluminum |
| Dimensions | 16.26 × 7.62 × 5.68 cm (6.4 × 3.0 × 2.2 in.) |
| Weight | 288–306 g (0.64–0.68 lb) |
| Onboard Memory | 80 MB flash for OS/program, 30 MB for data storage |
| Protocols | PakBus, Modbus RTU/TCP, DNP3, SDI-12, TCP/IP, UDP, TLS 1.2, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS, NTP, DHCP, SLAAC, ICMP, Telnet, PPP, RNDIS, Auto-IP |
| Real-Time Clock Accuracy | ±1 minute per month |
| Brand | CAMPBELL |
|---|---|
| Origin | USA |
| Model | CR350 |
| Operating Temperature | -40 to +70 °C (standard, non-condensing) |
| Max Scan Rate | 10 Hz |
| Enclosure Material | High-impact polycarbonate (Recycling Code 7) |
| Analog Inputs | 4 single-ended or 2 differential (software-configurable) |
| Pulse Counters | 8 (P_SW, P_LL, C1, C2, SE1–SE4) |
| Excitation Terminals | 2 (VX1, VX2) |
| Communication Interfaces | USB Type-C 2.0, RS-232, RS-485 |
| 12 V Switched Power Outputs | 2 |
| Digital I/O | 7 (C1, C2, P_SW, SE1–SE4 |
| Input Range | -100 to +2500 mV |
| Analog Voltage Accuracy | ±(0.04% of reading + offset) at 0–40 °C |
| ADC Resolution | 24-bit |
| Power Supply Input (CHG) | 16–32 Vdc (max 1.1 A for charger/solar input) |
| Real-Time Clock Accuracy | ±1 min/month |
| Supported IP Protocols | Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP (APIPA), IPv4, IPv6, UDP, TCP, TLS v1.2, DNS, DHCP, SLAAC, NTP, Telnet, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS, MQTT(S) |
| Communication Protocols | PakBus, PakBus Encryption, Modbus RTU/ASCII/TCP, DNP3, SDI-12 |
| CPU & Program Memory | 50 MB serial flash |
| Data Storage | 50 MB serial flash |
| Idle Current Draw | 0.5 mA (@ 12 Vdc) |
| Active Current Draw | 8 mA (@ 12 Vdc, processor always on) |
| Dimensions | 16.3 × 8.4 × 5.6 cm (6.4 × 3.3 × 2.2 in.) |
| Weight | 288–306 g (0.64–0.68 lb), depending on comms options |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR6 |
| Processor | 32-bit ARM Cortex-M4 with hardware floating-point unit (100 MHz) |
| Internal Memory | 4 MB RAM, 6 MB flash for OS, 1 MB serial flash for program execution |
| MicroSD Card Support | Up to 16 GB |
| Real-Time Clock Accuracy | ±3 minutes/year (±10 µs with GPS synchronization) |
| USB Interface | USB 2.0 Full-Speed (12 Mbps), host/device capable |
| Ethernet | 10/100BASE-T |
| Communication Protocols | PakBus, SDI-12, SDM, RS-232, RS-485, CPI (Campbell Peripheral Interface) |
| U-Port Capabilities | Simultaneous analog/digital input, static vibration measurement (100 Hz – 6.5 kHz), bridge excitation (±2.5 V or ±2.5 mA), thermistor support (5 kΩ reference), frequency measurement up to 200 kHz |
| Analog Input | 12 single-ended or 6 differential channels |
| ranges | ±5000 mV, ±1000 mV, ±200 mV |
| Analog Output | 12-bit DAC (±2.5 V or ±2.5 mA) |
| Digital I/O | 12 configurable ports (3.3 V / 5 V logic) |
| Power Input | 12 V DC battery, solar (16–32 V DC), or USB |
| SW12V outputs | 2 × 12 V @ 1100 mA (20 °C) |
| Overvoltage Protection | All terminal strips include transient voltage suppression |
| Operating Temperature | −25 °C to +50 °C (extended range options available) |
| Dimensions | 20.3 × 10.2 × 6.1 cm |
| Weight | 0.42 kg |
| Compliance | CE, FCC Part 15 Class B, RoHS |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR6 |
| Operating Temperature Range | -40 to +70°C (standard), -55 to +85°C (extended) |
| Analog Input Resolution | 24-bit ADC |
| Analog Voltage Accuracy | ±(0.04% of reading + offset) at 0–40°C |
| Input Channels | Up to 12 single-ended or 6 differential analog inputs |
| Communication Interfaces | Ethernet (10/100 RJ-45), USB Micro-B (virtual Ethernet & serial), RS-485, RS-422, SDI-12, CPI, CS I/O |
| Data Storage | 4 MB SRAM + 72 MB flash + microSD slot (up to 16 GB) |
| Power Supply | 10–18 Vdc (BAT), 16–32 Vdc (CHG) |
| Real-Time Clock Accuracy | ±3 min/year (GPS optional: ±10 µs) |
| Vibration Compensation | VSECT® spectral analysis for static vibrating-wire measurements |
| Enclosure | UV-stabilized TPE over impact-resistant polycarbonate (Recycling Code 7) |
| Dimensions | 21.0 × 10.2 × 5.6 cm |
| Weight | 0.42–0.52 kg |
| Brand | Campbell Scientific |
|---|---|
| Model | CR800 |
| Origin | USA |
| Differential Input Channels | 3 (6 single-ended) |
| Analog Input Resolution | 13-bit A/D |
| Scan Rate | Up to 100 Hz |
| Operating Temperature Range | 0 to 40 °C |
| Voltage Measurement Resolution | 0.33 µV |
| Sleep Mode Current Draw | ~0.6 mA |
| Active Current Draw (w/o RS-232) | 1–16 mA |
| Active Current Draw (w/ RS-232) | 17–28 mA |
| Communication Interfaces | 1 × CS I/O port, 1 × RS-232 serial port |
| Supported Protocols | PakBus®, Modbus RTU/ASCII, SDI-12, SDM, DNP3, FTP, HTTP, XML, POP3, SMTP, Telnet, NTCIP, NTP |
| Onboard Memory | 4 MB (data + program storage) |
| Data Format | Tabular ASCII |
| Operating System | PakBus OS |
| Compatible Software | LoggerNet, PC400, Short Cut |
| Optional Peripheral | CR1000KD handheld display |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | DaqLink |
| Pricing | Available Upon Request |
| Brand | DataTaker |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | CEM20 |
| Price | USD 1,120 (FOB) |
| Input Channels | 20 per module |
| Max. Modules per DT80 (v2+) | 5 |
| Max. Modules per DT85 (v2+) | 16 |
| Max. Analog Inputs | 300 (DT80), 960 (DT85) |
| Isolation | Dual-channel galvanic isolation per input pair |
| Input Configurations | 2 isolated differential or 3 shared single-ended per channel |
| Max. Input Voltage | 30 Vdc |
| Sampling Rate | 12 Hz (per CEM20) |
| Power Supply | 12 Vdc ±5% (from host or external) |
| Power Consumption | 0.36 W (active), <0.1 W (sleep mode) |
| Operating Temperature | −45 °C to +70 °C |
| Enclosure | Anodized aluminum housing with steel end plates |
| Dimensions | 180 × 100 × 50 mm |
| Weight | 0.55 kg |
| Communication Interface | Digital control via 5D/6D I/O lines |
| Max. Cable Distance (host to last CEM20) | 100 m |
| Addressing | 4-bit DIP switch (address range 1–15) |
| Status Indication | LED indicators for power, communication, and sampling activity |
| Included | Analog interface cable for DT80/DT85 host connection |
| Brand | DataTaker |
|---|---|
| Origin | Imported |
| Model | DT80 |
| Analog Inputs | 15 single-ended / 10 differential / 5 three- or four-wire |
| Resolution | 8-bit |
| Max Sampling Rate | 40 Hz |
| Excitation Outputs | 5 V / 12 V selectable, up to 150 mA |
| Digital I/O & Counter | 32-bit, up to 100 kHz |
| Communication Ports | RJ45 Ethernet, USB, RS232 (host), RS232/RS485/RS422 (configurable) |
| Protocols | MODBUS RTU (master/slave), MODBUS TCP/IP, SDI-12, ASCII |
| Network Support | HTTP, FTP, SMTP |
| Power Supply | 10–30 VDC |
| RTC Accuracy | ±1 min/year (0–40 °C), ±4 min/year (−40–70 °C) |
| Operating Temperature | −40 to +70 °C, 85% RH non-condensing |
| Enclosure Rating | IP54 |
| Dimensions | 180 × 137 × 65 mm |
| Weight | 1.5 kg |
| Internal Storage | 128 MB CompactFlash (upgradable to 4 GB), optional 8 GB USB storage |
| Internal Battery | 6 V @ 1.2 Ah |
| Origin | Australia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DT80 Series 2 |
| Pricing | Upon Request |
| Brand | DataTaker |
|---|---|
| Origin | Imported |
| Model | DT80G |
| Analog Inputs | 15 single-ended / 10 differential / 5 three- or four-wire |
| Resolution | 8-bit |
| Sampling Rate | up to 40 Hz |
| Vibrating Wire Channel | integrated, 500–5 kHz range, coil resistance 50–200 Ω, excitation pulse: 36 V @ 200 µs |
| Digital I/O & Counter | 32-bit, up to 100 kHz |
| Communication | RJ45 (Ethernet), USB, RS232/RS485/RS422 |
| Protocols | MODBUS RTU/TCP, SDI-12, ASCII, HTTP, FTP, SMTP |
| Power | 10–30 VDC |
| Operating Temperature | −40 to +70 °C |
| Enclosure Rating | IP54 |
| Dimensions | 180 × 137 × 65 mm |
| Weight | 1.5 kg |
| Internal Storage | 128 MB CompactFlash (upgradable to 4 GB), optional 8 GB USB drive |
| Real-Time Clock Accuracy | ±1 min/year (0–40 °C), ±4 min/year (−40–70 °C) |
| Internal Battery | 6 V @ 1.2 Ah |
| Brand | DataTaker |
|---|---|
| Origin | Imported |
| Model | DT82E |
| Analog Inputs | 6 single-ended / 4 differential / 2 three- or four-wire RTD channels |
| Resolution | 18-bit |
| Sampling Rate | up to 40 Hz |
| Excitation Outputs | 5 V / 12 V selectable, max 150 mA |
| Digital I/O | 8 configurable channels with 32-bit counter (100 kHz max) |
| Communication | RJ45 Ethernet, RS232 serial, SDI-12 master interface |
| Protocols | SDI-12, Modbus RTU (master), Modbus TCP/IP |
| Storage | 128 MB CompactFlash (upgradable), optional 8 GB USB flash |
| Operating Temperature | −40 °C to +70 °C |
| Enclosure Rating | IP54 |
| Dimensions | 180 × 137 × 65 mm |
| Weight | 900 g |
| Real-Time Clock Accuracy | ±1 min/year (0–40 °C), ±4 min/year (−40–70 °C) |
| Power Supply | 10–30 VDC |
| Origin | Australia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DT82e |
| Pricing | Upon Request |
| Brand | dataTaker |
|---|---|
| Origin | Imported |
| Model | DT82I |
| Analog Inputs | 6 single-ended / 4 differential / 2 three- or four-wire |
| Resolution | 18-bit |
| Sampling Rate | up to 40 Hz |
| Analog Output | 16-bit DAC, 0–10 V or 0–20 mA |
| Excitation Outputs | 5 V / 12 V selectable, max. 150 mA |
| Digital I/O & Counter | 32-bit, up to 100 kHz |
| Communication Ports | RJ45, RS232 (host), RS232/RS485/RS422 |
| Protocols | MODBUS RTU (master/slave), MODBUS TCP/IP, ASCII, SDI12 |
| Power Supply | 10–30 VDC |
| Operating Temperature | −40 to +70 °C |
| Enclosure Rating | IP54 |
| Dimensions | 180 × 137 × 65 mm |
| Weight | 900 g |
| Internal Storage | 128 MB CompactFlash (upgradable to 4 GB), optional 8 GB USB storage |
| Real-Time Clock Accuracy | ±1 min/year (0–40 °C), ±4 min/year (−40–70 °C) |
| Built-in Battery | 6 V @ 1.2 Ah |
| Brand | DataTaker |
|---|---|
| Origin | Imported |
| Model | DT85 |
| Analog Inputs | 48 single-ended / 32 differential / 16 three- or four-wire |
| Resolution | 18-bit |
| Sampling Rate | up to 40 Hz |
| Excitation Outputs | 5 V / 12 V, 150 mA max |
| Digital I/O & Counters | 32-bit, up to 100 kHz |
| Communication Ports | RJ45 (Ethernet), USB, RS232 (host), RS232/RS485/RS422 (multi-protocol) |
| Protocols | MODBUS RTU/TCP/IP, SDI-12, ASCII, HTTP, FTP, SMTP |
| Power Supply | 10–30 VDC |
| Operating Temperature | −40 °C to +70 °C |
| Enclosure Rating | IP54 |
| Dimensions | 300 × 137 × 65 mm |
| Weight | 2.5 kg |
| Internal Memory | 128 MB CompactFlash (upgradable to 4 GB), optional 8 GB USB storage |
| Real-Time Clock Accuracy | ±1 min/year (0–40 °C), ±4 min/year (−40–70 °C) |
| Origin | Australia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DT85 Series 2 |
| Pricing | Upon Request |
| Brand | DataTaker |
|---|---|
| Origin | Imported |
| Model | DT85G |
| Analog Input Channels | 48 single-ended / 32 differential / 16 three- or four-wire |
| Resolution | 18-bit |
| Sampling Rate | up to 40 Hz |
| Excitation Outputs | 5 V / 12 V, max 150 mA |
| Digital I/O & Counter | 32-bit, up to 100 kHz |
| Vibrating Wire Channel | integrated, 500–5000 Hz range, coil resistance 50–200 Ω, excitation pulse 36 V @ 200 µs |
| Communication | RJ45 (Ethernet), USB, RS232/RS485/RS422 |
| Protocols | MODBUS RTU/TCP, SDI-12, ASCII, HTTP, FTP, SMTP |
| Power | 10–30 VDC |
| Internal Battery | 6 V @ 4 Ah |
| Operating Temperature | −40 °C to +70 °C |
| Storage | 128 MB CF (upgradable to 4 GB), optional 8 GB USB drive |
| Enclosure Rating | IP54 |
| Dimensions | 300 × 137 × 65 mm |
| Weight | 2.5 kg |
| RTC Accuracy | ±1 min/year (0–40 °C), ±4 min/year (−40–70 °C) |
| Brand | EverACQ Technologies |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | μXI-X3658 |
| Pricing | Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | DaqPRO 5300 |
| Pricing | Available Upon Request |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | MetStream 100 |
| Power Consumption | 2 W |
| Operating System | Embedded Linux |
| Serial Interface Support | RS-232 / RS-422 / RS-485 |
| Ethernet Interface | 10/100 Base-T |
| Maximum Sampling Rate | 32 Hz |
| Onboard Storage | 8 GB microSD |
| Surge & EMC Protection | IEC 61000-4-5 Level 3, IEC 61000-4-4 Level 3 |
| Web-Based Configuration | Yes |
| Protocol Support | Modbus RTU/ASCII, NMEA 0183, ASCII text streams, custom serial protocols |
| Brand | Gill |
|---|---|
| Origin | USA |
| Model | TFT |
| Display Size | 8.5-inch LED-backlit industrial LCD |
| Viewing Angle | 170° true wide-angle |
| Resolution | WVGA (800 × 480) |
| Wind Data Input | NMEA 0183 (4800 baud) directly from Gill anemometers |
| Power Output | +15 VDC for sensor and daisy-chain expansion |
| Power Input | 100–240 VAC, 50/60 Hz (max. 50 VA) or optional 18–32 VDC |
| Dimensions | 238 × 148.5 × 71 mm |
| Weight | 1.2 kg |
| IP Rating | IP22 |
| Operating Temperature | −15 °C to +55 °C |
| Operating Humidity | 10–93 % RH |
| EMC Compliance | IEC 61000-4-2 (ESD), IEC 61000-4-3 (Radiated Immunity), IEC 61000-4-4 (Fast Transients), IEC 61000-4-5 (Surge), IEC 61000-4-6 (Conducted Immunity) |
| Brand | Grant |
|---|---|
| Origin | UK |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMK610 |
| Pricing | Upon Request |
| Brand | Grant |
|---|---|
| Origin | UK |
| Model | OQ610-S |
| Channels | 6 |
| Thermocouple Types | K or T |
| Temperature Range | −200 °C to 1300 °C (K-type), −200 °C to 400 °C (T-type) |
| Accuracy | ±0.5 °C (−50–500 °C), ±1.0 °C (−200–1300 °C) |
| Resolution | 0.1 °C |
| Sampling Rate | 0.5 s to 2 h per channel |
| Max Samples | 260,000 (non-volatile flash memory) |
| Display | 2×16-character LCD |
| Interface | USB 1.1/2.0 |
| Power | 2×AA batteries (200 h typical life) |
| Dimensions | 148 mm × 95 mm × 21 mm |
| Weight | 450 g |
| Operating Environment | −30 °C to +65 °C, ≤95% RH |
| Brand | Grant |
|---|---|
| Origin | UK |
| Model | SQ2010 |
| Analog Inputs | 4–8 (universal, single-ended or differential) |
| Digital Inputs | 8 |
| Calculated/Export Channels | 16 |
| Alarm Outputs | 2 open-drain FETs (18 V, 0.1 A) |
| Pulse Counters | 2 (0–100 Hz & 0–64 kHz) |
| Accuracy | ±0.1% of reading + 0.1% of range |
| A/D Resolution | 24-bit |
| Internal Memory | 16 MB (up to 14 million readings) |
| Sampling Rate | 10 Hz on one channel (dual-speed mode), 1 Hz on all channels (standard) |
| Display | 128 × 64 dot-matrix graphic LCD |
| Power | 2 × C cells (5 days continuous @ 1 Hz) |
| Operating Temperature | −20 to +65 °C |
| Humidity | up to 95% RH (non-condensing) |
| Compliance | CE, RoHS |