Electrochemical Instruments
Filter
Showing 1261–1290 of 1703 results
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | EmStat4R |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±30 mA |
| Current Accuracy | ≤ 0.2% |
| Potential Accuracy | ≤ 0.2% |
| Potentiostatic Range | ±3 V |
| EIS Frequency Range | 10 µHz to 200 kHz |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | EmStat4S |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±30 mA |
| Current Accuracy | ≤ 0.2% |
| Potential Accuracy | ≤ 0.2% |
| Potentiostatic Range | ±3 V |
| EIS Frequency Range | 10 µHz to 200 kHz |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | EmStat4T |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±30 mA |
| Current Accuracy | ≤ 0.2% |
| Potential Accuracy | ≤ 0.2% |
| Potentiostatic Range | ±3 V |
| EIS Frequency Range | 10 µHz to 200 kHz |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | EmStat4X |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±30 mA |
| Current Accuracy | ≤ 0.2% |
| Potential Accuracy | ≤ 0.2% |
| Potentiostatic Range | ±3 V |
| EIS Frequency Range | 10 µHz to 200 kHz |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | MultiEmStat4 |
| Channel Count | 4 / 8 / 12 (configurable) |
| Current Range | ±30 mA |
| Current Accuracy | ≤ 0.2% |
| Potential Accuracy | ≤ 0.2% |
| Potentiostatic Range | ±3 V |
| EIS Frequency Range | 10 µHz to 200 kHz |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NEXUS |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | 100 pA to 1 A (11 decades) |
| Current Accuracy | ±0.1% of reading |
| Potential Accuracy | ±0.1% of full scale |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Communication Interface | USB-C and Ethernet |
| Onboard Storage | 32 GB internal flash memory |
| Optional Dual-Potentiostat Mode | Available |
| Software Platform | .NET-based desktop application with SDK and MethodSCRIPT™ support |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | PS4&MUX8/MUX16 |
| Instrument Type | Portable Electrochemical Workstation |
| Number of Channels | 8 (expandable to 128 via daisy-chained MUX8-R2 modules) |
| Current Range | 100 pA to 10 mA (9 decades) |
| Current Accuracy | ≤ 0.1 % |
| Potential Accuracy | ≤ 0.2 % |
| Potentiostatic Range | ±10.000 V |
| EIS Frequency Range | 10 μHz to 1 MHz |
| Power Supply | Rechargeable Li-ion battery or USB-powered |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | Sensit BT |
| Instrument Type | Portable Electrochemical Workstation |
| Current Range | 100 nA to 3 mA |
| Current Accuracy | < 1% of selected current range |
| Potential Accuracy | ≤ 0.5% |
| Potentiostatic Range | −1.7 V to +2.0 V |
| EIS Frequency Range | 0.016 Hz to 200 kHz |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | Sensit_BT |
| Instrument Type | Portable Electrochemical Workstation |
| Current Range | 100 nA to 3 mA |
| Current Accuracy | < 1% of selected current range |
| Potential Accuracy | ≤ 0.5% |
| Potentiostatic Range | −1.7 V to +2.0 V |
| Electrochemical Impedance Spectroscopy (EIS) Frequency Range | 0.016 Hz to 200 kHz |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | SensitSmart |
| Instrument Type | Portable Electrochemical Workstation |
| Current Range | 100 nA to 3 mA |
| Current Accuracy | < 1% of selected current range |
| Potential Accuracy | ≤ 0.1% |
| Potentiostatic Range | −1.7 V to +2.0 V |
| EIS Frequency Range | 0.016 Hz to 200 kHz |
| Communication & Power | USB-C |
| Dimensions | 43 × 25 × 11 mm |
| Compatible Electrode Pitch | 2.54 mm |
| Electrode Thickness Support | 0.1–0.8 mm |
| Max Electrode Width | 11 mm |
| Supported Techniques | LSV, CV, DPV, SWV, NPV, CA, I–t, PAD, OCP, MA, EIS |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | PalmSens 4 |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | 100 pA to 10 mA (9 ranges) |
| Current Accuracy | ≤ 0.1 % of Full-Scale Reading (FSR) |
| Potential Accuracy | ≤ 0.1 % of FSR |
| Potentiostatic Range | ±10.000 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | EL-Cell |
|---|---|
| Origin | Germany |
| Model | PAT-Chamber |
| Dimensions (W × D) | 380 mm × 640 mm |
| Height (open/closed lid) | 600 mm / 375 mm |
| Weight (empty) | 32 kg |
| Compatibility | PAT-Core test cells, ECC-PAT-Core cells, PAT-16, PAT-Pressure |
| Data Channels | Battery current, battery voltage, half-cell voltage, temperature, single-cell pressure |
| Interface | Compatible with standard potentiostats/galvanostats and battery cyclers |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PCA |
| Price Range | USD 700 – 10,000 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-Purpose |
| Measurement Range | −1000 to +1000 mV |
| Meter Accuracy | ±0.1% of full scale |
| Meter Resolution | 1 mV |
| Titration Precision | ±1 mV |
| Brand | Metrohm Autolab |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab B.V. |
| Type | Single-Channel Potentiostat/Galvanostat |
| Max Current Output | ±100 mA |
| Current Range | 10 nA – 10 mA (7 decades) |
| Current Resolution | 30 fA (at 10 nA range) |
| Current Accuracy | ±0.2% of reading ± 0.2% of range |
| Potential Range | ±10 V |
| Applied Potential Accuracy | ±2 mV ± 0.2% of setting |
| Potential Resolution | 150 µV (applied), 3–300 µV (measured, selectable) |
| Potentiostat Bandwidth | 1 MHz |
| Rise/Fall Time (1 V step, 10–90%) | < 250 ns |
| Input Impedance | > 100 GΩ |
| Bias Current (25°C) | < 1 pA |
| Coulometric Integrator | Built-in, hardware-based |
| iR Compensation | Positive feedback and current-interrupt modes |
| Electrode Configuration | 2-, 3-, or 4-electrode |
| Analog I/O | 16-bit DAC/ADC, programmable voltage/current control and monitoring |
| Software | NOVA 2.1+ (Windows only) |
| Compliance | CE, RoHS, ISO 9001 certified design |
| Data Integrity | Audit-trail enabled in NOVA for GLP/GMP environments |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PHS-3C |
| Pricing | Available Upon Request |
| Accuracy Class | 0.01 |
| pH Range | 0.00–14.00 pH |
| mV Range | ±1400 mV |
| Resolution | 0.01 pH / 1 mV / 0.1 °C |
| Temperature Compensation | 0–60 °C |
| Basic Error (pH) | ±0.1 pH |
| Input Impedance | ≥3 × 10¹¹ Ω |
| Input Current | ≤1 × 10⁻¹¹ A |
| Repeatability (pH) | ≤0.05 pH |
| Stability | ±0.05 pH ±1 digit / 3 h |
| Dimensions (L×W×H) | 220 × 160 × 65 mm |
| Weight | 0.3 kg |
| Power Supply | DC 6 V |
| Operating Environment | 5–50 °C, RH ≤85%, No Strong Vibration or Magnetic Interference |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PHS-3C |
| Pricing | Available Upon Request |
| Display | 3½-digit LED |
| Temperature Compensation | Manual (0–60 °C) |
| Calibration | One-point or Two-point |
| Compatible Electrode | E-201-C pH Combination Electrode |
| Accuracy Class | 0.01 |
| pH Range | 0.00–14.00 pH |
| mV Range | ±0.00–1800.00 mV |
| pH Resolution | 0.01 pH |
| mV Resolution | 1 mV |
| pH Basic Error | ±0.01 pH ±1 digit |
| mV Basic Error | ±1 mV ±1 digit |
| Input Impedance | ≥1×10¹² Ω |
| Drift | ≤±0.01 pH ±1 digit / 3 h |
| Sample Temperature Range | 5–60 °C |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PHS-5 |
| Price Range | USD 280–420 |
| Instrument Type | Benchtop |
| pH Range | 0.00–14.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH ±1 digit |
| ORP Range | −1999.9 to +1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range | −20.0 to +100.0 °C |
| Temperature Resolution | 0.1 °C |
| Input Impedance | ≥3 × 10¹² Ω |
| Measurement Update Rate | 0.5 s |
| Auto-Save Calibration & State | Yes |
| Dimensions (W×H×D) | 200 × 128 × 60 mm |
| Weight | <1.0 kg |
| Power Supply | DC 12 V |
| Power Consumption | <0.5 W |
| Operating Environment | 5–45 °C, RH <85% (non-condensing) |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | PIN-PMN-PT |
| Pricing | Upon Request |
| Brand | Pine Instruments (Pine Test Equipment, Inc.) |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | AFMSRCE / MSR |
| Rotation Speed Range | 0–10,990 rpm |
| Motor Power | 20 W |
| Speed Display Accuracy | ±1% |
| Control Architecture | Separated Motor & Controller Units |
| Electrical Protection | Integrated Surge and Voltage Instability Protection |
| Interface | Analog Input/Output (0–10 V) for External Speed Command and Tachometer Signal Output |
| Electrode Compatibility | Standard RDE, RRDE, and Rotating Ring-Disk Electrode (RRDE) configurations |
| Brand | dc-energies |
|---|---|
| Volume | 150 mL |
| Port Configuration | One 24/25 ground-glass rotation port, four 14/20 side ports |
| Jacket Type | Double-walled with circulating coolant inlet/outlet |
| Gas Sealing | Dual F-type gas inlets + L-type gas outlet |
| Shaft Seal | PINE proprietary ceramic bearing seal assembly |
| Material | High-borosilicate glass (ASTM E438 Type I, Class A) |
| Compliance | Designed for ASTM D129, ISO 12927, and USP <797> electrochemical cell validation protocols |
| Brand | Pinnacle |
|---|---|
| Model | CD-30 |
| Type | Pocket-Sized Conductivity Meter |
| Origin | USA |
| Measurement Range | 0–1999 µS/cm and 0–19.99 mS/cm |
| Resolution | 1 µS/cm / 0.01 mS/cm |
| Accuracy | ±2% of reading |
| Temperature Compensation | Automatic, 0–50 °C |
| Calibration | Auto- or manual 1–2-point with buffer recognition |
| Electrode Diameter | 8 mm |
| Display | LCD with auto-hold |
| Power | 2×CR2032 (3 V) |
| Battery Life | ~200 hours |
| Auto-Off | After 8 min inactivity |
| Dimensions | 236 × 46 × 33 mm |
| Weight | 140 g |
| IP Rating | IP66+ |
| Standard Kit | Meter, replaceable electrode, calibration solutions, batteries, manual |
| Brand | PONSEL (France) |
|---|---|
| Origin | France |
| Model | PHEHT |
| Measurement Principle | Composite Glass Electrode (pH), Platinum Redox Electrode (ORP), NTC Thermistor (Temperature) |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.1 |
| ORP Range | −1000 to +1000 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±2 mV |
| Temperature Range | 0.00–50.00 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.5 °C |
| Response Time | <5 s |
| IP Rating | IP68 |
| Output Interface | Modbus RTU over RS-485 (standard), SDI-12 (optional) |
| Supply Voltage | 5–12 V DC |
| Standby Current | 25 µA |
| Active Current (1 Hz, RS-485) | 3.9 mA |
| Active Current (1 Hz, SDI-12) | 6.8 mA |
| Pulse Current | 500 mA |
| Dimensions (Ø × L) | 27/21 mm × 207 mm |
| Weight (sensor + 3 m cable) | 350 g |
| Housing Materials | PVC, Delrin®, specialty pH glass, platinum, polyamide |
| Max Pressure Rating | 5 bar |
| Cable | Armored coaxial polyurethane cable, bare leads or Fischer connector |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | FJ3003 |
| Instrument Type | Single-Channel Electrochemical Workstation |
| Analog Input Channels | 2 (auto-ranging: ±0.2 V, ±2 V, ±20 V) |
| Input Impedance | >10 MΩ |
| Sampling Rate | 100 MS/s |
| Display & Measurement Resolution | 4 significant digits |
| Temperature Measurement Accuracy | ±0.01 °C |
| Temperature Control Range | 15 °C above ambient to 100 °C |
| Temperature Setpoint Range | 0–100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Output Actuation | Zero-crossing triggered thyristor |
| Control Output | 5-step power output (max. 300 W) |
| Electrical Isolation | Analog-to-digital and overvoltage protection integrated |
| Compliance | Designed for academic lab environments |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JH11X |
| Instrument Type | Single-Channel Electrochemical Workstation |
| Potentiostatic Range | ±2 V |
| Current Range | ±2 mA / ±20 mA (dual-range) |
| Potential Resolution | 0.001 V |
| Current Resolution | 0.001 mA |
| Reference Electrode Input Impedance | ≥10¹² Ω |
| Cell Voltage Range | ±13 V |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 320 × 215 × 130 mm |
| Brand | PRIMA (UK) |
|---|---|
| Origin | Taiwan |
| Model | innoLab 10P |
| Instrument Type | Portable |
| Parameter Type | Single-Parameter |
| pH Range | -2.00 to 16.00 |
| ORP Range | -2000 to +2000 mV |
| Temperature Range | -5.0 to 120.0 °C |
| Resolution | 0.01 pH / 0.1 mV (±600.0 mV) / 0.1 °C |
| Accuracy | ±0.01 pH / ±0.2 mV (≤ ±600 mV), ±1 mV (> ±600 mV) / ±0.3 °C |
| Calibration | Up to 5-point auto-calibration with NIST-traceable buffers |
| Temperature Compensation | Automatic or manual |
| Display | 43 × 70 mm LCD |
| Power | 2 × AA batteries |
| IP Rating | IP65 (pH mode), IP67 (conductivity/DO-capable variants) |
| Dimensions | 73 × 152 × 42 mm |
| Weight | 250 g |
| Brand | PRIMA SCI (UK) |
|---|---|
| Origin | Shanghai, China |
| Model | innoLab 10P |
| Instrument Type | Portable |
| Parameter Type | Single-Parameter (pH/ORP/Temp) |
| Measurement Range | 0.00–14.00 pH (extended: –2.00 to +16.00 pH), –2000 to +2000 mV, –5.0 to 120.0 °C |
| Resolution | 0.01 pH, 0.1 mV (±600.0 mV), 1 mV (full range), 0.1 °C/0.1 °F |
| Accuracy | ±0.01 pH, ±0.2 mV (±600.0 mV), ±1 mV (full range), ±0.3 °C / ±0.5 °F |
| Calibration | Auto-recognition of 1–3 point NIST-traceable buffer calibration |
| Temperature Compensation | Automatic (ATC) or Manual (MTC), –5.0 to +120.0 °C |
| Electrode Interface | BNC + 3.5 mm temperature probe jack |
| Display | 43 × 70 mm LCD, 120° viewing angle |
| Housing Rating | IP65 |
| Dimensions | 73 × 152 × 42 mm (W × H × D) |
| Weight | 250 g |
| Power | 2 × 1.5 V AA alkaline batteries (>500 h operation) |
| Data Storage | Optional 100-point memory |
| Auto-Off | Selectable (10 min idle timeout) |
| Key Features | Differential signal circuitry, electrode health diagnostics (Slope/Offset), STABLE reading indicator, MTC fallback mode, ergonomic grip, scratch-resistant display |
| Brand | PRIMASCI |
|---|---|
| Origin | Shanghai, China |
| Model | innoLab 10 C |
| Portability | Handheld |
| Conductivity Range | 0–500 mS/cm |
| TDS Range | 0–500,000 ppm (as NaCl) |
| Resistivity Range | 0–100.0 MΩ·cm |
| Salinity Range | 0–325 ppt (Practical Salinity Scale) |
| Temperature Range | −5 to +120 °C |
| Accuracy | ±1% F.S. (Conductivity), ±0.3 °C (Temperature) |
| Resolution | 0.001 µS/cm (low range), 0.01 mS/cm (high range), 0.1 °C |
| Calibration | Auto-ranging 1-point or manual multi-point (up to 3 points) |
| Temperature Compensation | Automatic/manual, −5 to +120 °C, selectable reference temp (15–30 °C, default 25 °C) |
| Electrode Constants | 0.01, 0.1, 1.0, 10.0 cm⁻¹ |
| TDS Factor | 0.40–1.00 (adjustable) |
| Salinity Factor | 0.65 (PSS-78 compliant) |
| Memory Capacity | 100 data sets with timestamp |
| Display | 40 × 70 mm LCD, 120° viewing angle |
| IP Rating | IP67 |
| Power | 2 × AA alkaline batteries (>500 h operation) |
| Dimensions | 73 × 152 × 42 mm (W × L × H) |
| Weight | 250 g |
| Brand | PRIMASCI |
|---|---|
| Origin | Taiwan |
| Model | innoLab 20C |
| Form Factor | Benchtop |
| Conductivity Range | 0–500 mS/cm |
| TDS Range | 0–500,000 ppm (as NaCl) |
| Resistivity Range | 0–18.30 MΩ·cm |
| Salinity Range | 0–325 ppt |
| Temperature Range | −5 to +120 °C |
| Accuracy | ±0.5% of Full Scale |
| Minimum Resolution | 0.001 µS/cm (at lowest range) |
| Electrode Constants Supported | 0.01, 0.1, 1.0, 10.0 cm⁻¹ |
| Temperature Compensation | Automatic or Manual (−5 to 120 °C), Reference Temp: 15–30 °C (default 25 °C) |
| TDS Conversion Factor | Adjustable 0.40–1.00 |
| Salinity Conversion Factor | Fixed 0.65 |
| Data Storage | 100 measurement records |
| Power | AC 100–240 V + internal rechargeable Li-ion battery (1300 mAh) |
| Dimensions | 150 × 194 × 56 mm (W × L × H) |
| Weight | 1.0 kg |
| Brand | PRIMASCI |
|---|---|
| Model | innoLab 20P |
| Type | Benchtop pH Meter |
| Parameters | Single-parameter (pH, ORP, Temperature) |
| Measurement Range | −2.00 to +16.00 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration | Auto-recognizing 1–3-point calibration with USA-standard buffers |
| Electrode Compatibility | Glass electrode or antimony electrode (HF-resistant mode) |
| Temperature Compensation | Automatic (ATC) or manual (MTC), −5.0 to 120.0 °C |
| Data Storage | 100 measurement records |
| Power | AC 100–240 V adapter + built-in rechargeable Li-ion battery (1300 mAh) |
| Dimensions | 150 × 194 × 56 mm (W × L × H) |
| Weight | 1.0 kg |