| Brand | QSense |
|---|---|
| Origin | Finland |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | QSense Initiator |
| Price | Upon Request |
| Minimum Sample Volume | 40 µL |
| Temperature Range | 15–65 °C |
| Frequency Range | 1–70 MHz |
| Brand | QSense |
|---|---|
| Origin | Sweden |
| Model | Omni |
| Minimum Sample Volume | 90 µL |
| Temperature Range | 4–70 °C |
| Frequency Range | 1–72 MHz |
| Brand | QSense |
|---|---|
| Origin | Finland |
| Model | Pro |
| Minimum Sample Volume | 40 µL |
| Temperature Range | 15–65 °C |
| Frequency Range | 1–70 MHz |
| Brand | QSense |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QSensor |
| Price Range | USD 1–9,999 |
| Key | Brand: Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | A-Z Series |
| Price Range | USD 1–1,400 (FOB) |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | Si+SiO₂ Thin-Film QCM Substrate |
| Pricing | Available Upon Request |
| Crystal Orientation | <100> or <111> |
| Doping Type | N-type or P-type |
| Fabrication Method | Dry or Wet Oxidation |
| SiO₂ Thickness | 50 nm – 1 µm (customizable) |
| Si Wafer Thickness | 0.5 mm |
| Standard Dimensions | Ø100 mm (4") or Ø50 mm (2") |
| Surface Configuration | Single-Side or Double-Side Oxidized |
| Packaging | Class 1000 Cleanroom-Processed, Sealed in Class 100 Clean Bags |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | QCM-25-2IN |
| Pricing | Available Upon Request |
| Brand | Ransburg |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 76652-01 / 76652-02 / 76652-03 / 76652-04 |
| Power Supply | 9V Alkaline Battery |
| High Voltage Range | ±0–199.9 kV |
| Short-Circuit Current Range | ±0–1999.9 µA |
| Conductance Range | 0.01–199.9 mS/cm (with 7922-00 Paint Probe) |
| Resistivity Range | 10⁰–10⁹ Ω·cm (typical for solvent-based and waterborne coatings) |
| Electrode Material | Corrosion-Resistant Stainless Steel |
| Compliance | Designed for industrial electrostatic spray process control per ITW Ransburg engineering specifications |
| Brand | Rayscience |
|---|---|
| Origin | Germany |
| Model | CVP21 |
| Instrument Type | Electrochemical Capacitance–Voltage Profiling System |
| Application Domain | Semiconductor Doping Profile Characterization |
| Carrier Concentration Range | 1×10¹¹ to 1×10²¹ cm⁻³ |
| Depth Resolution | Down to ≤1 nm |
| Sample Compatibility | Wafer-scale (up to 300 mm), micro-samples, epitaxial layers, bulk crystals |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | Red Sun Instrument |
|---|---|
| Model | HR-280 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Control Range | Ambient to 300.0 °C (independently adjustable per bath) |
| Temperature Accuracy | ±0.1 °C (per bath) |
| Temperature Sensor | Imported Pt100 Platinum Resistance Thermometer |
| Heating Power | 1.5 kW (rated) |
| Bath Configuration | 4 independent metal heating baths |
| Stirring Speed | 1400 rpm |
| Timing Range | 0.01 s to 99 h 59 min |
| Display | 7-inch capacitive touch LCD with Chinese menu interface |
| Data Storage | Onboard non-volatile memory |
| Compliance | GB/T 7326–2016 (Petroleum Products — Determination of Copper Strip Corrosion) |
| Brand | RedMatrix |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PS-PEC008 |
| Instrument Category | Electrochemical Instrument Accessory |
| Light Source Configuration | 8-channel integrated high-power monochromatic LED array (365–980 nm + white light options) |
| Max Irradiance | 200 mW/cm² |
| LED Power per Channel | 10 W (optical output: 5.4 W) |
| Spectral Range | 365–980 nm (25 discrete bands + 5 white light CCTs) |
| Light Window Diameter | 12 mm |
| LED Lifetime | >20,000 h |
| Switching Speed | <1 ms (electronic on/off, no mechanical shutter) |
| Control Interface | USB, Bluetooth, analog TTL trigger |
| Software Integration | PSTrace v4.x (compatible with PalmSens4 potentiostat/galvanostat) |
| Compliance | Designed for GLP-compliant photoelectrochemical workflows |
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-A |
| Current Range | ±250 mA |
| Potential Range | −10 V to +10 V |
| Reference Electrode Input Impedance | 10 MΩ |
| Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| CE High-Voltage Power Supply Output | 0–20 kV / 0–300 µA |
| Photodetector HV Input | −100 to −1000 V |
| Wavelength Response Range | 300–650 nm (peak @ 420 nm) |
| Dynamic Range | >5 decades |
| Amplifier Gain | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Integration Time | 0.001–10 s |
| Sampling Rate | 1–200 Hz |
| Signal Noise | ≤0.5 mV (P-P, 1× gain) |
| Amplifier Drift | <0.05% |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-E |
| Current Range | ±250 mA |
| Potential Range | −10 V to +10 V |
| Reference Electrode Input Impedance | 10 MΩ |
| Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 auto-ranging decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| Luminescence Detection Dynamic Range | >5 decades |
| Photomultiplier Tube (PMT) High Voltage | −100 V to −1000 V |
| Emission Wavelength Range | 300–650 nm (Peak Sensitivity at 420 nm) |
| PMT Spectral Responsivity | >1000 A/lm |
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MPI-EII |
| Pricing | Available Upon Request |
| Electrochemical Potential Range | −10 V to +10 V |
| Current Range | ±250 mA |
| Reference Electrode Input Impedance | 10 MΩ |
| Current Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| Luminescence Dynamic Range | >5 decades |
| Photometric Accuracy | <0.05% |
| Gain Settings | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Amplifier Drift | <0.05% |
| Peak-to-Peak Noise | ≤0.5 mV (1× gain) |
| Input Impedance (Optical) | ≥10 MΩ |
| Integration Time | 0.01–10 s |
| Sampling Rate | 1–200 Hz |
| PMT High Voltage | −100 V to −1000 V |
| Spectral Range | 230–920 nm (λₚₑₐₖ = 630 nm) |
| Anode Sensitivity | >2000 A/lm |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | RFL-II |
| Detector Type | Electrochemical Luminescence Analyzer with Integrated Spectral Photomultiplier Module |
| High-Voltage Power Supply | −100 V to −1000 V (stability ±0.05%, output current ≥5 mA) |
| Gain Settings | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Signal Noise | ≤0.5 mV<sub>P-P</sub> (at 1× gain) |
| Input Impedance | ≥10 MΩ |
| Integration Time Range | 0.01–1000 s |
| Sampling Rate | 1–1000 Hz |
| Spectral Response | 230–920 nm (peak sensitivity at 630 nm) |
| Anode Sensitivity | >2000 A/lm |
| Software Functions | Real-time signal acquisition, auto-zero calibration, AGC (Automatic Gain Control), peak/area quantification, spectral export (TXT), VFD-based local parameter display |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | RPEC-A |
| Light Source | 300 W Xenon Arc Lamp |
| Spectral Range | 200–1000 nm |
| Wavelength Accuracy | ±0.25 nm |
| Wavelength Repeatability | ±0.1 nm |
| Minimum Wavelength Step | 0.01 nm |
| Spectral Bandwidth | 0.054–16.2 nm (adjustable slit: 10 µm–3 mm) |
| Electrochemical Potential Range | −10 V to +10 V |
| Current Range | ±250 mA |
| Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Scan Rate | 0.001–65 V/s |
| Reference Electrode Input Impedance | 10 MΩ |
| Operating System | Windows-based Dedicated Software |
| Brand | REMEX (Xi’an Remex) |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RPEL-B |
| Pricing | Upon Request |
| Potential Applications | Antigen/Antibody Detection, Pathogen Screening (e.g., Influenza A, HIV, Plague), Small-Molecule Biomarker Analysis (Hormones, Toxins, Glucose, Amino Acids) |
| Operating Modes | Standalone & PC-Connected (USB) |
| Electrode Format | Disposable Screen-Printed Electrodes (WE: Pt, CE: Pt, RE: Ag/AgCl or user-specified) |
| Dimensions | 140 × 110 × 110 mm (L×W×H) |
| Weight | <0.8 kg |
| Battery Life | >10 h continuous operation |
| Data Storage | Up to 1000 assay records |
| Optical Detection Range | 230–920 nm |
| Electrochemical Range | Potential: −3 V to +3 V |
| Current | ±50 mA |
| Scan Rate | 0.001–200 V/s |
| Sampling Rate | 1–200 points/s |
| Dynamic Range | >5 decades |
| Measurement Accuracy | <0.05% FS |
| Interfaces | USB 2.0 (PC control/data transfer), DB9 RS-232 (mini-printer output) |
| Integrated Magnetic Separation Module | Yes |
| Sample Volume | 5–10 µL per test |
| Compatible Substrates | Paper-based chips, ceramic chips, custom solid-phase electrochemiluminescent platforms |
| Brand | ROOKO |
|---|---|
| Model | LX-9830GA |
| Type | Benchtop Voltage Drop Analyzer |
| Measurement Parameters | Contact Resistance, Voltage Drop, Current, Open-Circuit Voltage, Temperature |
| Current Range | 0–300 A (selectable ranges: 0–40 A / 0–60 A / 0–100 A / 0–200 A / 0–300 A) |
| Voltage Range (open-circuit) | 0–12 V / 0–24 V / 0–30 V (optional) |
| Voltage Drop Range | 0–199.99 mV |
| Resolution | 0.01 mV (voltage drop), 0.01 A (current), 0.01 V (voltage) |
| Accuracy | ±1% of reading |
| Test Time Setting | 0.01 s – 99.99 h |
| Temperature Measurement Range | 0–25 °C (integrated sensor) |
| Compliance Standards | QC/T 29106–2004, QC/T 730–2005, ISO 6722:2002, GB/T 2951–1997, GB/T 3048–1994, QC/T 413–2002, SAE USCAR-38:2009 |
| Interface Options | RS-232, USB 2.0 |
| Data Management | Password-protected instrument configuration, pass/fail counting (0–99999), audible/visual alarm on limit violation |
| External Integration | PLC control interface, PC software (optional), printer support, custom fixture compatibility |
| Brand | dc-energies |
|---|---|
| Diameter | 5 mm (active disk) |
| Overall Outer Diameter | 15 mm |
| Material | High-purity glassy carbon disk, PTFE-insulated shaft, stainless steel or brass housing (configurable) |
| Origin | Hubei, China |
| Instrument Type | Electrochemical Working Electrode Accessory |
| Brand | dc-energies |
|---|---|
| Material Options | Glassy Carbon (GC), Gold (Au), Platinum (Pt) |
| Disk Diameter | 5.0 mm |
| Overall Electrode Outer Diameter | 15 mm |
| Operating Temperature Range | 10–25 °C |
| Brand | dc-energies |
|---|---|
| Disk Diameter | 5.61 mm |
| Ring Outer Diameter | 15.0 mm |
| Material | Glassy Carbon Disk / Platinum Ring |
| Insulator | PTFE Shroud |
| Max Rotation Speed | 3000 rpm |
| Collection Efficiency | 37% |
| Operating Temperature | ≤25 °C |
| Origin | Hubei, China |
| Instrument Type | Electrochemical Working Electrode |
| Brand | DC-Energies |
|---|---|
| Model | RRDE High-Temperature |
| Disk Material | Glassy Carbon |
| Ring Material | Platinum |
| Disk Diameter | 5.61 mm |
| Ring Outer Diameter | 15.0 mm |
| Collection Efficiency | 37% |
| Rotation Speed Range | Up to 3000 rpm |
| Housing Material | PTFE |
| Operating Temperature | Elevated Temperature Capability (Designed for >25°C environments, compatible with thermostatted electrochemical cells) |
| Compliance | ASTM D1308, ISO 13473-2 (Electrode Geometry & Calibration Standards), GLP-Compatible Configuration |
| Brand | Sanotac |
|---|---|
| Model | C1000 |
| Application | In-line conductivity detection for chromatographic protein purification |
| Conductivity Range | 1 µS/cm to 500 mS/cm |
| Temperature Range | 0–99 °C |
| Temperature Accuracy | ±1 °C |
| Conductivity Accuracy | ±2% FS |
| Flow Rate Compatibility | 100–1000 mL/min |
| Tubing Connection | 1/8" (3.2 mm) compression fitting |
| Display | 256×64 dot-matrix backlit LCD |
| Control Interface | Front-panel keypad + PC-based software with remote control capability |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions (W×D×H) | 370 × 240 × 95 mm |
| Compliance | FDA 21 CFR Part 11 (audit trail, electronic signature, role-based user access), GLP/GMP-ready architecture |
| Brand | Sanpu |
|---|---|
| Model | PHS-2000 |
| Type | Portable Pen-Style pH Meter |
| Measurement Range | 0.0–14.0 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.2 pH |
| Temperature Compensation | Automatic (0–50 °C) |
| Power Supply | 4 × 1.5 V AG-13 button cells |
| Battery Life | ~1000 hours |
| Dimensions | 142 × 29 × 15 mm |
| Weight | 65 g |
| Calibration Buffers | pH 6.86 (phosphate), pH 9.18 (borax) or pH 14.00 (potassium hydrogen phthalate) |
| IP Rating | IP67 (dust-tight and immersion-resistant up to 1 m for 30 min) |
| Compliance | Meets GB/T 11165–2022 (Chinese national standard for laboratory pH meters) |
| Brand | SANXIN |
|---|---|
| Model | 5021 |
| Measurement Range | 0–10.00 mS/cm (auto-ranging across three segments: 0–99.9 μS/cm, 100–999 μS/cm, 1.00–10.00 mS/cm) |
| Resolution | 0.1/1 μS/cm |
| Accuracy | ±1% FS |
| Temperature Compensation | 5–50 °C (automatic, NTC 30 kΩ) |
| Calibration | Single-point auto-calibration with 1413 μS/cm standard solution |
| Power Supply | Two AAA batteries (1.5 V × 2) |
| Dimensions | 39 × 25 × 176 mm |
| Weight | 87 g |
| Ingress Protection | IP57 |
| Origin | Shanghai, China |
| Manufacturer | SANXIN Peirui Instrument Co., Ltd. |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | 5031 |
| Price | ¥426 |
| Measurement Range | (0–5.00) ppt (auto-ranging across three segments: 0–49.9 ppm, 50–499 ppm, 0.50–5.00 ppt) |
| Resolution | 0.1/1 ppm |
| Accuracy | ±1% FS |
| Temperature Compensation | Automatic, 5–50 °C (reference 25 °C, temp. coefficient 2%/°C) |
| Calibration | Single-point auto-calibration with 4.20 ppt standard solution |
| Power Supply | Two AAA batteries (1.5 V × 2) |
| Dimensions | 39 × 25 × 176 mm |
| Weight | 87 g |
| Ingress Protection | IP57 |
| Replaceable Electrode | Yes |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | 5041 |
| Measurement Range | ±100 mV |
| Resolution | 1 mV |
| Accuracy | ±0.5% FS |
| Power Supply | Two AAA batteries (1.5 V × 2) |
| Dimensions | 39 × 25 × 176 mm |
| Weight | 95 g |
| IP Rating | IP57 |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | 5051 |
| Price | USD 60 (approx.) |
| Measurement Range | 0–5.00 ppt |
| Resolution | 0.01 ppt |
| Accuracy | ±1% FS |
| Temperature Compensation | Automatic, 5–50 °C |
| Calibration | Single-point, factory-predefined 3.00 ppt standard |
| Power Supply | Two AAA batteries (1.5 V × 2) |
| Dimensions | 39 × 25 × 176 mm |
| Weight | 87 g |
| Ingress Protection | IP57 |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DDB-11A |
| Measurement Range | (a) 0.0–199.9 µS/cm (deionized water) |
| Accuracy | ±1% FS ±1 digit (basic error) |
| Power Supply | One 9V alkaline battery (6F22) or external 9V DC adapter |
| Dimensions (meter) | 162 × 43 × 25 mm |
| Electrode Dimensions | Ø12 × 130 mm |
| Weight | 210 g (including battery) |
| Operating Temperature | 5–35 °C |
| Compliance | Designed for field-deployable GLP-compliant conductivity measurements in environmental and industrial QA/QC workflows |