Electrochemical Instruments
Filter
Showing 1411–1440 of 1703 results
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 99580-0 |
| Conductivity Range | 0–2000 pS/m |
| Resolution | 0.1 pS/m and 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Operating Temperature | −30 °C to +50 °C |
| Power Source | Replaceable AAA batteries |
| Compliance | ASTM D2624, IP 274, GB/T 6539 |
| Measurement Principle | AC Conductance (2-electrode, frequency-compensated) |
| Brand | Shenchanghong |
|---|---|
| Model | PH-650 |
| Type | Portable pH Meter |
| Measurement Range | 0.00–14.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.03 pH |
| Temperature Compensation Range | 0.0–99.9 °C |
| Input Impedance | ≥10¹² Ω |
| Data Storage | 999 readings with timestamp |
| Power Supply | Rechargeable Li-ion battery |
| Dimensions | 185 × 92 × 50 mm |
| Weight | 370 g |
| Calibration | Auto-recognition of NIST-traceable buffers (Chinese variant) |
| Compliance | Meets GB/T 23776–2018 and JJG 1107–2015 metrological verification requirements |
| Brand | Shengaohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Parameter Type | Single-Parameter (pH/ORP/Temp) |
| Measurement Accuracy | ±0.01 pH |
| pH Range | 0.00–14.00 pH |
| ORP Range | −1999 to +1999 mV |
| Temperature Range | 0.0–100.0 °C |
| pH Resolution | 0.01 pH |
| ORP Resolution | 1 mV |
| Temperature Resolution | 0.1 °C |
| Temperature Compensation | Manual |
| Calibration | 2-point pH calibration (using pH 7.00 standard buffer) |
| Input Impedance | ≥1 × 10¹² Ω |
| Input Current | ≤2 × 10⁻¹² A |
| Operating Temperature | 0–50 °C |
| Dimensions | 157 × 76 × 38 mm |
| Weight | 206 g |
| Instrument Class | 0.1-grade |
| Brand | Shengaohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Model | PHS-300 |
| Measurement Parameters | Dual (pH and mV) |
| pH Accuracy | ±0.01 |
| pH Range | −2.00 to 16.00 |
| mV Range | −1000 to +1000 mV |
| pH Resolution | 0.01 |
| mV Resolution | 1 mV |
| Temperature Compensation | Automatic (0.0–60.0 °C) |
| Temperature Sensor | PT1000 |
| Calibration | Auto-buffer recognition, 3-point calibration |
| Standard Buffer Compatibility | NIST-traceable (Chinese national standard version) |
| Instrument Class | 0.01-level |
| Brand | Shengaohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | SH-5 |
| Detection Parameter | Single-parameter (Conductivity) |
| Portability | Portable |
| Application Site | Field & Lab Environments |
| Conductivity Range | 0–200,000 µS/cm |
| Temperature Range | 0–60 °C |
| Accuracy | ±3% of reading |
| Minimum Resolution | 0.1 µS/cm (dependent on range) |
| Electrode Type | Digital Four-Electrode Graphite Sensor |
| Temperature Compensation | Automatic, ±0.1 °C |
| Communication Interface | RS485 |
| Response Time | ≤15 s |
| Display | Backlit LCD with Clock Function |
| Calibration | Single-point calibration |
| Electrode Cable Length | 3 m (customizable) |
| Operating Environment | 0–60 °C, non-freezing |
| Power Supply | Rechargeable Lithium-ion Battery |
| Dimensions | 20 × 10 × 3.5 cm |
| Net Weight | 610 g |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic |
| Model | Si+SiO2+Ti+Pt (Domestically Sourced) |
| Pricing | Upon Request |
| Film Thickness | SiO₂ = 500 nm |
| Silicon Substrate | p-type, B-doped, resistivity < 0.005 Ω·cm |
| Standard Dimensions | Ø101.6 mm × 0.5 mm (4" wafers) or 10 mm × 10 mm × 0.5 mm |
| Surface Finish | Single-side polished |
| Packaging | Individual wafers in Class 100 cleanroom bags within Class 1000 cleanroom environment |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Si Crystal Substrate |
| Pricing | Upon Request |
| Doping Type | B- or P-doped (p-type) / N-doped (n-type) |
| Resistivity | 10⁻³ – 40 Ω·cm |
| EPD (Etch Pit Density) | ≤100 cm⁻² |
| Oxygen Content | ≤1.8 × 10¹⁸ cm⁻³ |
| Carbon Content | ≤5 × 10¹⁶ cm⁻³ |
| Crystal Orientation | <100>, <110>, or <111> ± 0.5° (custom orientations available) |
| Standard Dimensions | Ø25.4 mm × 0.30 mm, Ø50.8 mm × 0.50 mm, Ø76.2 mm × 0.50 mm, Ø101.6 mm × 0.60 mm |
| Surface Roughness | Ra < 0.1 nm (10 Å) |
| Optional Surface Modifications | Thermal SiO₂ layer (thickness customizable), or pre-fabricated multilayer stacks: Si/SiO₂/Ti/Pt |
| Packaging | Individual wafers in Class 100 cleanroom bags |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Si-Ge (2 wt% Ge) |
| Conductivity Type | P-type |
| Resistivity | 7–8 Ω·cm |
| Surface Finish | Single-side polished |
| Standard Orientation | <100> |
| Standard Dimensions | Ø100 mm × 0.5 mm |
| Packaging | Class 1000 Cleanroom / Class 100 Clean Bag |
| Customization | Available for orientation, diameter, thickness, and double-side polish upon request |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Ag-Foil |
| Thickness Range | 0.01–1 mm (custom-cut available) |
| Packaging | Vacuum-sealed in Class 100 cleanroom bags, stored and shipped from Class 1000 cleanroom environment |
| Pricing | USD 0.50–500.00 per piece (volume-dependent) |
| Brand | SM |
|---|---|
| Origin | Germany |
| Model | LF40 |
| Portability | Portable |
| Application Environment | Laboratory & Field |
| Conductivity Range | 0–200 mS/cm (auto-ranging across 0–200 μS/cm, 0–2000 μS/cm, 0–20 mS/cm, 0–500 mS/cm) |
| TDS Ranges | 0–200 mg/L, 0–2000 mg/L, 0–20 g/L, 0–500 g/L |
| Salinity Range | 0–70 g/kg |
| Temperature Range | −10 to +100 °C |
| Resolution | 0.1 μS/cm (low range), 0.01 mS/cm / 0.1 mS/cm (mid/high ranges), 0.1 °C |
| Temperature Compensation | Pt1000 sensor (automatic or fixed) |
| Display | 128 × 64 pixel backlit LCD |
| Data Storage | 4000 measurement records |
| Connectivity | Isolated USB interface |
| Enclosure Rating | IP65 |
| Dimensions | 200 × 95 × 40 mm (W × H × D) |
| Weight | 290 g (with 3 × AA batteries) |
| EMC Compliance | EN 61326 Class B |
| Standard Electrode | LTC 0.35/LF 40 (4-pole, cell constant 0.33 cm⁻¹, integrated Pt1000 temperature sensor, 1 m cable with BK 6-pin connector) |
| Included Accessories | Carrying case, LF40 main unit, 3 × AA batteries, LTC 0.35/LF 40 electrode, 50 mL KCl 1413 μS/cm calibration solution |
| Brand | SM |
|---|---|
| Origin | Germany |
| Model | TM39 |
| Measurement Ranges | pH 0–14, mV −1999 to +1999, Temperature −70 to +250 °C |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Temperature Compensation | Automatic (Pt100) or Manual |
| Calibration | Auto 2-/3-point pH calibration |
| Display | LCD, 2-line × 4-digit |
| Power | 9 V battery (IEC 6F22) |
| Interface | RS-232 (TM39-D variant) |
| Operating Environment | 0–50 °C |
| Dimensions (H×W×D) | 142 × 71 × 26 mm |
| Weight | ~145 g |
| Electrode Connection | BNC (pH/ORP), Mini-DIN (temperature) |
| Compatible Electrode | EGA142/TM39 (pH/Temp composite, Ø12 mm, 120 mm immersion, Pt1000 sensor, Ag/AgCl reference, 3 mol/L KCl gel electrolyte, max. 6 bar) |
| Brand | SMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ABL |
| Pricing | Available Upon Request |
| Brand | MTI Corporation (OEM by Hefei Kejing) |
|---|---|
| Origin | Anhui, China |
| Model | SMT-72ESD |
| Dimensions | Ø13 × 72 mm |
| Suction Cup Diameters | 6.4 mm / 9.5 mm / 12.5 mm / 19 mm |
| Corresponding Max Suction Force | 15 g / 30 g / 80 g / 150 g |
| Tip Configuration | Straight or Bent |
| Handle Material | ESD-Safe Silicone Rubber |
| Compliance | ANSI/ESD S20.20, IEC 61340-5-1 |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FJA-10 |
| Portability | Handheld / Field-Deployable |
| Calibration Compatibility | KCl/NaCl standard solutions (0.01–0.2 mol/L) |
| Electrode Material | Graphite |
| Temperature Compensation | Integrated NTC thermistor |
| Response Time | <20 s |
| Minimum Volumetric Water Content for Reliable Measurement | ~20% (varies with clay content) |
| Electrode Constant | Adjustable (factory-set to 100 cm⁻¹ for direct mS/cm readout) |
| Linearity (0.02–0.3 N) | R² ≥ 0.98 |
| Repeatability | Relative average deviation ≤5% (max. 10%) |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1260A |
| Channel Count | Single-Channel Workstation |
| Current Range | 200 nA – 2 A |
| Current Accuracy | ±0.2% of reading + ±1% of full scale |
| Potential Accuracy | ±0.2% of reading + ±10 mV |
| Potentiostatic Range | ±14.5 V (when coupled with 1287) / ±40.95 V (1260A standalone) |
| AC Impedance Frequency Range | 10 µHz – 32 MHz |
| Voltage/Current Resolution | 1 µV / 1 pA |
| Frequency Resolution | 0.015 ppm |
| Phase Accuracy | ±0.1° |
| Magnitude Accuracy | ±0.1 dB |
| Electrode Configurations | 2-, 3-, and 4-terminal |
| Active Shielding | Yes |
| Floating Measurement Capability | Yes |
| Software | CorrWare & ZPlot v3.x |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1260A |
| Instrument Type | Multi-Channel Electrochemical Workstation |
| Current Range | ±60 mA |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±40.95 V |
| AC Impedance Frequency Range | 10 µHz – 32 MHz |
| Phase Accuracy | ±0.1° |
| Magnitude Accuracy | ±0.1% |
| Frequency Resolution | 0.015 ppm |
| Core Technology | Single-Sine Correlation Method |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1287/1260 |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±14.5 V |
| EIS Frequency Range | 10 µHz – 32 MHz |
| Voltage Resolution | 1 µV |
| Current Resolution | 1 pA |
| Polarization Voltage (1260A) | ±40.95 V |
| Frequency Resolution | 15 ppm (0.000015) |
| Phase Accuracy | ±0.1° |
| Magnitude Accuracy | ±0.1 dB |
| Measurement Configurations | 2-, 3-, and 4-terminal |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1455 / 1451 |
| Frequency Range | 10 Hz – 1 MHz (1455), 10 Hz – 100 kHz (1451) |
| Frequency Resolution | 1 / 65,000,000 |
| DAC Sampling Rate | 40 MHz |
| Accuracy | ±0.1% magnitude, ±0.1° phase |
| Phase Resolution | 0.01° |
| RMS Signal Amplitude | 3 V – 50 V |
| Waveform Options | Single-sine, multi-sine (FFT-based) |
| Input/Output Interface | Ethernet per module |
| Expandable Channels | 1–8 independent FRA units per system |
| Auxiliary Voltage Analyzer Ports | 4 (requires 14702A/14703A option with 1470E) |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1455 / 1451 |
| Channel Count | Multi-channel workstation |
| Current Range | ±4 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±10 V |
| AC Impedance Frequency Range | 10 µHz to 1 MHz |
| DAC Sampling Rate | 40 MHz |
| Frequency Resolution | 1 in 65,000,000 |
| Signal Amplitude Range | 1 mV–50 V (rms) |
| Phase Resolution | 0.01° |
| Voltage Resolution | 1 µV |
| Waveform Options | Single-sine, multi-sine (FFT-based) |
| Auxiliary Input Channels | 4 (with optional 14702A/14703A modules) |
| Communication Interface | Ethernet |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model Series | 1470E |
| Current Range | ±4 A |
| Current Accuracy | ±0.1% of full scale |
| Potential Accuracy | ±0.1% of full scale |
| Potentiostatic Range | −3 V to +10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1470E Series |
| Channel Count | Up to 8 independent channels per unit |
| Current Range | ±4 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Control Interface | Ethernet |
| Compliance | ASTM G102, ISO 17475, IEC 62660-2, USP <1058>, FDA 21 CFR Part 11 (software audit trail enabled) |
| Safety | Per-channel hardware-based voltage/current limit enforcement, fast-acting termination logic (<100 µs response) |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 6200 |
| Instrument Type | Electrochemical Workstation |
| Channel Capacity | Up to 120 channels (scalable via rack-mount chassis) |
| Current Range | ±200 mA per channel (up to ±2 A via 10-channel current paralleling) |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 20 kHz per channel |
| ADC Resolution | 24-bit |
| Sampling Rate | Up to 1000 samples/second across all active channels |
| Onboard Temperature Sensing | Integrated thermistor per channel |
| Data Storage | Direct-to-disk recording with optional RAID-enabled storage module |
| Compliance | Designed for GLP/GMP-aligned battery testing environments |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 9300R SA |
| Channel Count | 1–4 configurable channels |
| DC Current Range | ±200 A (±300 A pulse), up to ±800 A with 4-channel parallel operation |
| DC Current Accuracy | ±0.03% of reading |
| DC Potential Accuracy | ±0.03% of reading |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 1 mHz – 10 kHz |
| Voltage Resolution | 20 µV (24-bit ADC) |
| Current Resolution | 2 µA (24-bit ADC) |
| DC Sampling Rate | 1 kS/s per channel |
| Auxiliary Inputs | 2 differential voltage dividers (for DC/EIS), optional synchronized temperature acquisition |
| Power Supply | 3-phase 380 V AC, 5.5–11 kW |
| Brand | Solartron Analytical |
|---|---|
| Origin | USA |
| Model | 9300R-SA |
| Instrument Type | Multi-Channel Electrochemical Workstation |
| Channel Count | 1–4 Configurable Channels |
| DC Current Range | ±200 A (300 A Pulse), Up to ±800 A with 4-Channel Parallel Operation |
| DC Current Accuracy | ±0.02 % of Reading |
| Potential Accuracy | ±30 µV |
| Potentiostatic Range | +300 mV to +10 V |
| EIS Frequency Range | 1 mHz to 10 kHz |
| Voltage Resolution | 20 µV (24-bit ADC) |
| Current Resolution | 2 µA (24-bit ADC) |
| DC Sampling Rate | 1 kS/s |
| Auxiliary Voltage Divider Inputs | 2 (for DC/EIS) |
| Temperature Monitoring | Optional External 16-Channel Synchronized Acquisition |
| Power Supply | 3-Phase 380 V, 5.5–11 kW |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | Energylab XM |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | 0.1% + 0.05% + 30 fA |
| Potential Accuracy | 0.1% + 0.05% + 100 µV |
| Potentiostatic Range | ±8 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Impedance Measurement Limit | <100 µΩ (with external amplifier support up to 100 A) |
| Sampling Rate | Up to 1 MS/s (DC), 40 MS/s (FRA) |
| Auxiliary Differential Inputs | 4-channel synchronized with RE |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | Energylab XM |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±8 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Low-Impedance Measurement Capability | Down to 10 µΩ |
| Current Resolution | 100 aA |
| Voltage Resolution | 1 µV |
| Sampling Rate | Up to 1 MS/s (DC), 40 MS/s (FRA) |
| Auxiliary Differential Inputs | 4-channel |
| Compliance | ASTM G5, G59, G102 |
| Brand | Solartron Analytical |
|---|---|
| Origin | UK |
| Model | HV 9250 |
| Channel Configuration | Multi-channel (1 or 2 main channels + up to 5 auxiliary voltage divider channels) |
| Current Range | ±125 A to ±250 A |
| Current Accuracy | ±0.1% |
| Potential Accuracy | ±0.1% |
| Potentiostatic Range | ±60 V, ±120 V, ±240 V |
| EIS Frequency Range | 1 mHz – 10 kHz |
| Maximum Power per Main Channel | 10 kW |
| Data Acquisition Rate | 10 kS/s |
| ADC Resolution | 24-bit (120 µV main channel, 20 µV auxiliary) |
| Input Impedance | 10 MΩ (all voltage inputs) |
| Temperature Inputs | 6 thermistor channels (1 per main + 5 auxiliary), 16 thermocouple channels via external VTI1401 DAQ |
| Digital I/O | 1 input, 1 output (trigger/control) |
| Software Platform | Aspire™ electrochemical control and analysis suite |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | Modulab XM DSSC |
| Current Range | ±2 A |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | 0.1% reading + 0.05% range + 100 µV |
| Potentiostatic Range | ±100 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Compliance | NIST-traceable light source calibration |
| Software Platform | ModuLab XM Control & Analysis Suite |
| Upgrade Path | Compatible with legacy Modulab and Modulab XM hardware modules |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | Modulab XM DSSC |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Light Source | NIST-traceable, thermally stabilized LED-based optical platform with selectable high-brightness monochromatic LEDs |
| Software | ModuLab XM Suite with integrated FRA, CV, CP, EIS, IMPS/IMVS, Voc decay, charge extraction, and J-V analysis modules |
| Compliance | Fully compatible with GLP/GMP data integrity requirements |