Electrochemical Instruments
Filter
Showing 1501–1530 of 1703 results
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Orion Star T910 |
| Instrument Category | General-purpose Potentiometric Titrator |
| Measurement Range | pH: −2.000 to 20.000 |
| mV | −2000 to +2000 mV |
| Temperature | −5 to 100 °C |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | pH: 0.001 |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Titration Accuracy | (±0.3 mV ±1 digit) over 3 h |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ORPTestr 10 |
| Electrode Type | Double-Junction |
| Interface | BNC (ORPTestr 10 BNC variant) |
| Measurement Range | −999 to +1000 mV |
| Resolution | 1 mV |
| Accuracy | ±2 mV |
| Calibration | Single-point manual |
| Temperature Compensation | None |
| Operating Temperature | 0–50 °C |
| Display | Dual-line LCD (2.1 × 2.7 cm) |
| Power | 4 × 1.5 V button cells |
| Battery Life | >500 hours |
| Dimensions (Instrument Only) | 16.5 × 3.8 cm |
| Weight (Instrument Only) | 90 g |
| Packaging Dimensions | 18.5 × 6.5 × 5 cm |
| Package Weight | 200 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CON700 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | COND600 |
| Origin | USA |
| Instrument Type | Portable Conductivity/TDS/Temp Meter |
| IP Rating | IP67 |
| GLP Compliance | Yes |
| Measurement Principles | Two-electrode AC conductivity, temperature-compensated TDS calculation (linear α coefficient), NIST-traceable calibration |
| Key Ranges | Conductivity 0–200.0 mS/cm (5-range auto-ranging) |
| Resolution | 0.01 µS/cm (low range) to 0.1 mS/cm (high range) |
| Accuracy | ±1% of full scale + 1 LSD (conductivity & TDS) |
| Calibration | Up to 4-point automatic or 5-point manual using standard KCl solutions |
| Temperature Compensation | Linear, user-selectable α (0.00 to 10.00 %/°C), default 2.00 %/°C |
| Electrode Constant Range | 0.010–10.000 cm⁻¹ |
| Data Storage | 500 measurement sets with timestamp, temperature, and electrode ID |
| Connectivity | RS-232C serial port, IrDA infrared interface |
| Power | 4×AA alkaline batteries (≥200 h operation) or optional 9 V DC adapter (500 mA) |
| Dimensions (unit) | 18.3 × 9.5 × 5.7 cm |
| Weight (unit) | 460 g |
| Operating Environment | 0–50 °C, ≤95% RH non-condensing |
| Storage Environment | −25–70 °C |
| Display | Backlit LCD (5.4 × 7.1 cm active area), multi-parameter real-time view |
| Auto-off | Configurable 2–30 min idle timeout |
| Auto-hold | Yes |
| Certifications | CE, RoHS, FCC Class B |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | CON 6000 |
| Conductivity Range | 0.000–500.0 mS/cm |
| Resistivity Range | 3 Ω·cm – 100 MΩ·cm |
| TDS Range | 0.0–500.0 ppt |
| Accuracy | ±0.5% of full scale + 1 digit |
| Repeatability | ±0.01% of full scale |
| Temperature Range | −5.0 to 105.0 °C |
| Temp. Accuracy | ±0.2 °C |
| Temp. Repeatability | ±0.1 °C |
| Calibration | Auto or manual up to 4-point per range |
| Cell Constants | 0.1, 1.0, 10.0 cm⁻¹ |
| Display | 640 × 480 pixel color TFT touchscreen |
| Data Storage | Up to 10,000 readings with timestamp and user ID |
| Connectivity | USB, IrDA, RS-232C, Ethernet (RJ45) |
| Power | 9 VDC, 3.3 A, center-negative |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Dual Star Kit |
| Instrument Type | Benchtop |
| Parameter Channels | Dual-Channel (pH + ISE) |
| pH Accuracy | ±0.001 |
| pH Range | −2.000 to 19.999 |
| Resolution | 0.1 / 0.01 / 0.001 (user-selectable) |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV |
| ISE Concentration Range | 0–19999 (with up to 3 significant digits) |
| ISE Accuracy | ±0.1 mV equivalent |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Calibration Points | pH: 1–6 pts |
| ISE | 2–6 pts |
| Calibration Modes | Linear, Nonlinear, Standard Addition/Subtraction, Auto-Blank Correction |
| Data Storage | 1000 GLP-compliant entries (manual, timed, or auto-triggered) |
| Input Interfaces | Two BNC pH/ISE electrode ports, one 8-pin mini-DIN ATC probe port, reference electrode input |
| Output Interfaces | RS232, USB |
| Power Supply | 100–240 V AC adapter |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Dual Star |
| Instrument Type | Multifunctional Electrochemical Analyzer |
| pH Range | –2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| Calibration Points | 1–6 |
| Auto-Buffer Recognition | US, NIST, DIN, and User-Defined Buffers |
| Ion Concentration Range | 0–19999 |
| Ion Resolution | 1–3 significant digits |
| Ion Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Ion Units | ppm, mg/L, M, %, or unitless |
| ISE Methods | Single or Dual Known Addition/Standard Addition, Sample Addition/Subtraction |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Temperature Range | –5 to 105 °C |
| Temperature Resolution | 0.1 °C (–5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temperature Accuracy | ±0.1 °C |
| Display | Dual-channel LCD |
| Inputs | Two BNC, Two Reference Electrode, Two MiniDIN (for ATC probes) |
| Method Storage | 20 methods |
| Password Protection | Yes |
| Data Storage | 1000 readings |
| GLP Compliance | Yes |
| Data Interface | Bidirectional RS232, optional USB cable |
| IP Rating | IP54 |
| Safety Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| Power Supply | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 cm (H) × 17.0 cm (W) × 22.4 cm (D) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher brand) |
| Type | Portable Conductivity/TDS/Temperature Meter |
| Model | CON110 |
| Conductivity Range | 0–199.9 mS/cm (5 ranges) |
| Resolution | 0.05% of full scale |
| Conductivity Accuracy | ±1% FS + 1 LSD |
| TDS Range | 0–99.9 ppt (adjustable coefficient 0.40–1.00) |
| TDS Accuracy | ±1% FS + 1 LSD |
| Temperature Range | 0–100.0 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Compensation | Automatic/manual (0–80 °C) |
| Calibration | Auto 4-point / Manual 5-point |
| Data Storage | 100 measurement sets with timestamp |
| Electrode Constant Display | Yes (0.1, 1.0, 10.0 cm⁻¹) |
| Interface | RS232C |
| Power | 4×AAA alkaline batteries (200+ hr life) or 9 V DC adapter |
| Dimensions (unit) | 18 × 9 × 4 cm |
| Weight (unit) | 220 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | COND600 |
| Price | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher brand) |
| Type | Benchtop Conductivity/TDS/Temp Meter |
| Model | CON510 |
| Key Features | Auto-ranging (5 ranges), 4-point auto-calibration & 5-point manual calibration, built-in temperature compensation (NTC thermistor), 100-data storage, adjustable TDS factor, electrode constant selection (0.1 / 1.0 / 10.0 cm⁻¹) |
| Conductivity Range | 0–19.99 μS/cm, 20.0–199.9 μS/cm, 200–1999 μS/cm, 2.00–19.99 mS/cm, 20.0–199.9 mS/cm |
| Conductivity Resolution | 0.01 / 0.1 μS/cm |
| TDS Range (user-selectable factor) | 0–9.99 ppm, 10.0–99.9 ppm, 100–999 ppm, 1.00–9.99 ppt, 10.0–99.9 ppt, 0–199.9 ppt |
| TDS Resolution | 0.01 / 0.1 / 1 ppm |
| Conductivity Accuracy | ±1% full scale |
| Temperature Range | 0.0–80.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Temp. Compensation Coefficient | 0.0–10.0 %/°C |
| Reference Temperature | 15.0–30.0 °C |
| Display | LCD (5.9 × 3.2 cm), backlit |
| Power | 9 V DC regulated adapter (100–220 VAC input, linear supply) |
| Dimensions (H×W×D) | 23 × 18 × 6 cm |
| Weight | 750 g (instrument only) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CON6000 |
| Price | Upon Request |
| Conductivity Range | 0–200 μS/cm, 200.0 μS/cm–2.000 mS/cm, 2.000–20.00 mS/cm, 20.00–500.0 mS/cm |
| TDS Range | 0–200.0 ppm, 200.0–2000 ppm, 2.000–20.00 ppt, 20.00–500.0 ppt |
| Salinity Range | 0–90.00 ppt |
| Resistivity Range | 0–19.99 kΩ, 20.00–199.9 kΩ, 200.0 kΩ–1.999 MΩ, 2.000–100.0 MΩ |
| Temperature Range | −5.0–105.0 °C |
| Conductivity Accuracy | ±0.5% of full scale + 1 LSD |
| TDS/Salinity/Resistivity Accuracy | ±0.5% of full scale + 1 LSD |
| Temperature Accuracy | ±0.2 °C |
| Temperature Compensation | Automatic or manual (−5 to 100 °C), adjustable coefficient (0.000–10.000 %/°C), reference temperature (15.0–30.0 °C) |
| Calibration | Up to 4-point, auto- or manual |
| Electrode Constants Supported | 0.1, 1.0, 10.0 cm⁻¹ |
| Data Storage | 1,000 readings per user |
| Display | 11.43 × 15.24 cm Windows CE–based color touchscreen |
| Connectivity | BNC, DIN, phono sockets, SD card reader, USB (host & device), RS232C, RJ45, IrDA |
| Power Supply | 9 V DC regulated adapter (100–240 VAC input, SMPS) |
| Dimensions (H×W×D) | 16.5 × 23.5 × 8.9 cm |
| Weight | 1.1 kg (instrument only) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Model | pH 610 |
| Type | Portable Electrochemical Analyzer |
| Measurement Parameters | pH, ORP (mV), Temperature (°C) |
| pH Range | −2.000 to 20.000 |
| pH Resolution | 0.001 / 0.01 / 0.1 |
| pH Accuracy | ±0.002 |
| ORP Range | ±2000.0 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.2 mV + 1 LSD |
| Temperature Range | −10.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration Points | 1–6 |
| Auto-Buffer Recognition | USA, NIST, DIN, PWB, Custom |
| Temperature Compensation | Automatic or Manual (0.0–100.0 °C) |
| GLP Compliance | Yes |
| Data Storage | 500 readings with timestamp, electrode ID, and calibration history |
| IP Rating | IP67 |
| Display | Backlit LCD (5.4 × 7.1 cm) |
| Communication | IrDA infrared, RS232C, no cables required |
| Power | 4×AAA alkaline batteries (≥500 h life) or 9 V regulated DC adapter (500 mA) |
| Dimensions (H×W×D) | 18.3 × 9.5 × 5.7 cm |
| Weight | 460 g (instrument only) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | 3-Star |
| Price | Upon Request |
| Conductivity Range | 0.000–3000 mS/cm |
| Resolution | Up to 4 significant digits, down to 0.001 μS/cm |
| Accuracy | ±0.5% of reading or ±0.01 μS/cm (whichever is greater) |
| Resistivity Range | 0.0001–100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl |
| TDS Range | 0–19999 mg/L |
| Cell Constant Range | 0.001–199.9 cm⁻¹ |
| Reference Temperatures | 5, 10, 15, 20, or 25 °C |
| Electrode Compatibility | Two-electrode, four-electrode, and planar conductivity cells |
| Calibration Points | 1–5 manual points |
| Temperature Range | −5 to 105 °C |
| Temp. Resolution | 0.1 °C (−5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temp. Accuracy | ±0.1 °C |
| Temp. Compensation | Automatic or manual |
| Display | Backlit LCD with icon-driven interface |
| Input Interfaces | pH-BNC, temperature-miniDIN, stirrer-Phono-jack (benchtop only) |
| Communication | Bidirectional RS232, optional USB cable |
| Data Logging | 1000 readings |
| Calibration History | Last 10 calibrations stored |
| Method Storage | 10 user-defined methods |
| Password Protection | 10 independent user profiles |
| Power | 4×AA alkaline batteries |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| IP Rating | Benchtop: IP54 |
| Portable | IP67 |
| Dimensions (Benchtop) | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| (Portable) | 4.8 × 9.7 × 21.3 cm (H×W×L) |
| Battery Life (Portable) | ~2000 hours |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 4-Star |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | A215 (Benchtop), A325 (Portable) |
| Instrument Category | Benchtop |
| Parameter Types | Dual (pH & Conductivity) |
| Measurement Accuracy | ±0.001 pH / ±0.5% of reading (conductivity) |
| Conductivity Range | 0.001 μS/cm to 3000 mS/cm |
| Resolution | 0.001 μS/cm minimum or 4 significant digits |
| Calibration Solutions | Auto-recognized (USA/NIST/DIN buffers) |
| Data Storage | 2000 entries (A215), 5000 entries (A325), GLP-compliant |
| Environmental Rating | IP54 (benchtop), IP67 (portable) |
| Power | AC adapter or 4 × AA batteries |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | A215 (Benchtop), A325 (Portable) |
| Measurement Parameters | pH, mV/RmV, Conductivity, TDS, Salinity, Resistivity, Temperature |
| Portability | Benchtop (A215) / IP67-rated Portable (A325) |
| Conductivity Range | 0.001 µS/cm to 3000 mS/cm |
| TDS Range | 1–200 ppt |
| Resistivity Range | 2 Ω·cm to 100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl (relative) / 0.01–42 ppt practical salinity |
| Temperature Range | –5 °C to +105 °C |
| pH Accuracy | ±0.001 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | A216 (Benchtop), A326 (Portable) |
| Instrument Category | Benchtop |
| Parameter Count | Dual (pH & DO) |
| pH Accuracy | ±0.001 |
| pH Measurement Range | −2.000 to 20.000 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| mV Range | ±2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV |
| Polarographic DO Range | 0–90 mg/L |
| RDO Fluorescence DO Range | 0–50 mg/L |
| RDO DO Accuracy | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% of reading (20–50 mg/L) |
| DO Saturation Range | 0–600% (polarographic), 0–500% (RDO) |
| DO Saturation Accuracy | ±2% |
| Atmospheric Pressure Compensation | 450.0–850.0 mmHg |
| Salinity Correction | 0–45 ppt |
| Temperature Range | 0–50 °C |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 2000 entries (A216), 5000 entries (A326), with timestamp, date, sample ID, user ID, calibration data |
| Compliance | GLP-compliant data logging |
| Connectivity | RS232, USB |
| Power | 4 × AA batteries or AC adapter |
| IP Rating | IP54 (A216), IP67 (A326) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | A221 |
| Instrument Category | Portable |
| Parameter Types | Multi-parameter |
| pH Measurement Range | -2.000 to 20.000 |
| Resolution | 0.1 / 0.01 / 0.001 |
| Accuracy | ±0.001 |
| Calibration Buffer Recognition | USA / NIST / DIN auto-identification |
| Temperature Compensation | Automatic (ATC) with 8-pin mini-DIN probe interface |
| Data Storage | Up to 2000 GLP-compliant entries |
| Connectivity | USB and RS232 |
| Power | 4 × AA batteries or AC adapter |
| IP Rating | IP67 |
| Electrode Interface | BNC + ATC port |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | A322 |
| Detection Parameters | Multi-parameter (Conductivity, TDS, Salinity, Resistivity, Temperature) |
| Portability | Portable |
| Conductivity Range | 0.001 µS/cm to 3000 mS/cm |
| TDS Range | 1–200 ppt |
| Resistivity Range | 2 Ω·cm to 100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl (relative) / 0.01–42 ppt practical salinity |
| Temperature Range | −5 to 105 °C |
| Accuracy | ±0.5% of reading |
| Minimum Resolution | 0.001 µS/cm (or 4 significant digits) |
| Compliance | GLP-compliant data logging (5000 entries), ASTM D1125, ISO 7888, USP <645>, EN 27888, FDA 21 CFR Part 11-ready software support |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | PC700 |
| pH Range | –2.00 to 16.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH + 1 LSD |
| pH Calibration | Up to 5-point (pH 1.68, 4.01, 7.00, 10.01, 12.45) |
| Temperature Range | –10.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Conductivity Range | 0–200.0 mS/cm |
| Conductivity Resolution | 0.1 / 0.01 mS/cm |
| Conductivity Accuracy | ±1% of full scale |
| Conductivity Calibration | Up to 5-point per range |
| TDS Range | 0–100 ppt (TDS factor 0.5) |
| TDS Resolution | 0.1 / 0.01 ppt |
| TDS Accuracy | ±1% of full scale + 1 digit |
| TDS Calibration | Up to 5-point per range |
| mV Range | ±2000 mV |
| mV Resolution | 0.1 mV (±199.9 mV), 1 mV (>±200 mV) |
| mV Accuracy | ±0.2 mV (±199.9 mV), ±2 mV (>±200 mV) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Model | pH6+ |
| Instrument Type | Portable |
| Measurement Parameters | pH, ORP, Temperature (°C) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| ORP Range | ±1000 mV |
| ORP Resolution | 0.1 mV (up to 199.9 mV), 1 mV (above) |
| ORP Accuracy | ±2 mV ±1 LSD |
| Calibration Points | 3-point (pH) |
| Buffer Standards | USA, NIST, PWB |
| ATC/MTC Compensation | 0–100 °C |
| Auto-Off | After 20 min inactivity |
| Power Supply | 4 × 1.5 V AAA alkaline batteries |
| Battery Life | >200 hours |
| Display | LCD (4.5 × 2.3 cm) |
| Dimensions (unit) | 14 × 17 × 3.5 cm |
| Weight (unit) | 200 g |
| Packaging Dimensions | 36 × 28 × 8 cm |
| Packaging Weight | 1500 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | PH700 |
| Origin | USA |
| Type | Benchtop Electrochemical pH Meter |
| pH Range | −2.00 to 16.00 |
| pH Resolution & Accuracy | 0.01, ±0.01 pH |
| mV Range | ±2000 mV |
| mV Resolution & Accuracy | 0.1 mV (±199.9 mV), 1 mV (±200 mV+) |
| Temperature Range | 0.0 to 100.0 °C |
| Temp Resolution & Accuracy | 0.1 °C, ±0.5 °C |
| Calibration Points | Up to 5-point |
| Buffer Standards | USA (pH 4.01, 7.00, 10.01) and NIST (pH 4.01, 6.86, 9.18) |
| Temperature Compensation | Automatic or Manual (0–100 °C) |
| Data Storage | 100 measurements |
| Output Interface | RS-232 or USB (with optional cable) |
| Power Supply | 9 V DC adapter |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | PHTestr 30 |
| Origin | USA |
| Type | Waterproof Portable pH/Temp Pen Meter |
| Measurement Range | pH –1.00 to 15.00, Temperature 0 to 50 °C |
| Resolution | 0.01 pH / 0.1 °C |
| Accuracy | ±0.01 pH / ±0.5 °C |
| Calibration | Auto 3-point with USA (4.01, 7.00, 10.01) or NIST (4.01, 6.86, 9.18) buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Design | Double-junction Ag/AgCl reference system with high-capacity gel electrolyte |
| Auto-off | After 8.5 minutes of inactivity |
| Display | Dual-line LCD (2.1 × 2.7 cm) |
| Power | 4 × 1.5 V button cells (LR44) |
| Battery Life | >500 hours |
| Operating Temperature | 0–50 °C |
| Dimensions (Instrument) | 16.5 × 3.8 cm |
| Weight (Instrument) | 90 g |
| Packaging Dimensions | 18.5 × 6.5 × 5 cm |
| Weight (Packaged) | 200 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | pHTestr30 |
| Price | Upon Request |
| pH Range | –1.00 to 15.00 |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration | Up to 3-point, auto-buffer recognition (pH 4.01, 7.00, 10.01) |
| Temperature Range | 0.0 to 50.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.1 °C |
| ATC | Built-in automatic temperature compensation |
| Enclosure Rating | IP67 |
| Electrode Design | Dual-junction (double salt bridge), gel-filled KCl electrolyte with enhanced gel volume |
| Electrode Module | Replaceable sensor cartridge |
| Display | Dual-line LCD, configurable °C/°F output |
| Brand | Eutech Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Eutech 1700 Series Benchtop Water Quality Analyzer |
| Form Factor | Benchtop |
| Measurement Parameters | pH, Conductivity, Dissolved Oxygen (DO) |
| Display | Large Backlit LCD |
| Data Output | USB and RS232 |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Warranty | Standard 2-year limited warranty |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Expert CTS |
| Measurement Parameters | Single-parameter (Conductivity, TDS, Salinity, Temperature) |
| Form Factor | Pen-style portable meter |
| Conductivity Range | 0.00 – 20.00 mS/cm |
| TDS Range | 0.00 – 20.00 ppt |
| Resistivity Range | 0 – 50 MΩ·cm |
| Salinity Range | 0.0 – 10.0 ppt |
| Temperature Range | 0.0 – 50.0 °C |
| Accuracy | ±2% full scale ±1 LSD |
| Resolution | 10 µS/cm below 2.00 mS/cm |
| Auto-Calibration Points | 84 µS/cm, 1413 µS/cm, 12.88 mS/cm |
| TDS Conversion Factor | Adjustable (0.40–1.00) |
| Temp Compensation | Automatic (ATC), 0–50.0 °C |
| Display | Dual-line 4-digit LCD with status icons |
| Power | 4 × A76 (LR44) batteries |
| Auto-Off | 8.5 min inactivity |
| IP Rating | IP67 |
| Dimensions | 170 × 45 × 30 mm (L×W×H) |
| Operating Temperature | 5–45 °C |
| Battery Life Indicator | Yes |
| Calibration Status Indicator | Yes |
| Stand & Sample Cup | Integrated protective cap |
| Lanyard | Included |
| Floatation | Buoyant design |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Expert pH |
| Instrument Type | Pen-style |
| Parameter Type | Single-parameter (pH) |
| Measurement Accuracy | ±0.1 pH |
| pH Range | 0.0–14.0 pH |
| Resolution | 0.1 pH |
| Calibration Standard | NIST-traceable buffer solutions |
| Temperature Range | 0.0–50.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.5 °C + 1 LSD |
| Calibration Points | 1–3-point auto-recognized |
| ATC | Yes |
| IP Rating | IP67 |
| Auto-off | 8.5 min idle |
| Power | 4 × A76/LR44 batteries |
| Operating Temp. | 5–45 °C |
| Dimensions | 170 × 45 × 30 mm (L×W×H) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Pen-Style pH Meter |
| Model | EXPERTPH |
| Measurement Parameters | pH and Temperature (°C/°F) |
| pH Range | 0.0–14.0 |
| pH Resolution | 0.1 pH |
| pH Accuracy | ±0.1 pH |
| Temperature Range | 0.0–50.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C ±1 LSD |
| Calibration Points | 1–3 point auto-buffer recognition |
| ATC | Yes |
| Auto-Off | 8.5 min inactivity |
| Power Supply | 4 × A76/LR44 batteries |
| Operating Temperature | 5–45 °C |
| IP Rating | IP67 |
| Dimensions | 170 × 45 × 30 mm (L×W×H) |
| Calibration Standard | NIST-traceable buffers |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3-Star 310P-01 |
| Pricing | Upon Request |
| pH Range | –2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| Calibration Points | 1–5-point, with US/NIST, DIN, and user-defined buffers |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Temperature Range | –5 to 105 °C |
| Temperature Resolution | 0.1 °C (–5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Compensation | Automatic or manual |
| Display | Backlit LCD |
| Electrode Interfaces | pH–BNC, Temperature–miniDIN, Stirrer–phone jack |
| Communication | Bidirectional RS232, optional USB cable |
| Data Storage | 200 GLP-compliant readings |
| Calibration History | Last 10 calibrations |
| Method Storage | 10 password-protected methods |
| Self-Diagnostic Function | Yes |
| Firmware Upgrade | Network-enabled via PC software |
| Power | 4×AA batteries + universal AC adapter (benchtop) |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH |
| Enclosure Rating | IP54 (benchtop) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3-Star 310P-02 |
| Pricing | Upon Request |