Electrochemical Instruments
Filter
Showing 1441–1470 of 1703 results
| Brand | Solartron Analytical |
|---|---|
| Origin | UK |
| Model | Modulab XM ECS |
| Current Range | ±2 A |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | 0.1% reading + 0.05% range + 100 µV |
| Potentiostatic Range | ±100 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | ModuLab XM MTS (1296A + 1294A) |
| Current Range | ±2 A |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | ±0.2% of setting |
| Potentiostatic Range | ±100 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Impedance Measurement Range | 100 Ω – 100 TΩ (12 decades) |
| Dielectric Loss Tangent Resolution | tan δ < 10⁻⁴ |
| Max DC Bias Voltage | 1000 V (with external high-voltage source or amplifier) |
| Compliance | IEC 601 for biomedical applications (1294A), ASTM D257, ISO 3001, IEEE Std 930 |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | ModuLab XM MTS |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±8 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Optional High-Impedance Interface | 1296A (Impedance Range: 100 Ω – 100 TΩ, 12 decades |
| Frequency | 10 µHz – 10 MHz |
| Optional Biomedical Interface | 1294A (IEC 601 compliant) |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | ModuLab XM PhotoChem IPCE |
| Current Range | ±300 mA |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | 0.1% reading + 0.05% range + 100 µV |
| Potentiostatic Range | ±8 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Compliance | NIST-traceable light source calibration included |
| Software | ModuLab XM Suite with dedicated PhotoElectroChemical (PEC) experiment modules |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | ModuLab XM PhotoChem IPCE |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±8 V to ±100 V (high-voltage option) |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Light Source Calibration | NIST-traceable |
| Software Platform | ModuLab XM Suite with PhotoElectroChem module |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | ModuLab XM PhotoEchem IPCE |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±2 A |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | 0.1% reading + 0.05% range + 100 µV |
| Potentiostatic Range | ±100 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Brand | Solartron Analytical |
|---|---|
| Origin | USA |
| Model | 9300R |
| Instrument Type | Multi-Channel Electrochemical Workstation |
| Channel Count | Up to 40 channels (42U rack) / 20 channels (24U rack) |
| Current Range | 2–200 A continuous (300 A pulse, 60 s) |
| Current Accuracy | ±0.03% of full scale |
| Potential Accuracy | ±0.03% of full scale |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 mHz – 10 kHz |
| EIS Frequency Resolution | 1 mHz |
| Auxiliary Voltage Inputs | 2 per channel |
| Temperature Inputs | Up to 16 per PoE-based unit |
| Power Supply | 3-phase, 200–480 V AC |
| Module Power | 3 kW per 5-channel module |
| Brand | Sonnen |
|---|---|
| Model | T03 |
| Origin | Shanghai, China |
| Instrument Type | General-purpose Automatic Potentiometric Titrator |
| Minimum Titration Volume | 10 µL |
| Accuracy | ±0.15% (at 10 mL), ±0.2% (at 20 mL) |
| Stepper Motor Resolution | 1/60,000 steps |
| Display | High-brightness color LCD |
| Interface Language | English & Chinese selectable |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 200 × 200 × 260 mm |
| Weight | 4.3 kg |
| Tubing Material | Imported PTFE |
| Piston Material | Imported corrosion-resistant high-performance polymer |
| Fill/Empty Time | ≤30 s (at 100% flow rate) |
| Flow Rate Control | Continuously adjustable |
| Quantitative Dispensing | Programmable volume range |
| Brand | Sonnen |
|---|---|
| Origin | Shanghai, China |
| Model | T11 |
| Instrument Type | Universal Automatic Potentiometric Titrator |
| Application Scope | General-purpose chemical analysis |
| mV Measurement Range | ±2000 mV |
| pH Measurement Range | 0–14 |
| mV Resolution | 0.1 mV |
| pH Resolution | 0.01 |
| Temperature Resolution | 0.1 °C |
| Temperature Range (PT1000) | 0–50 °C |
| Colorimetric Resolution | 1/65535 |
| Titration Volume Range | <99.99 mL |
| Burette Capacity | 25 mL |
| Minimum Dispensing Volume | 10 µL |
| Titration Resolution | 1/60000 |
| Maximum Titration Error | ±0.15% (at 10 mL), ±0.2% (at 20 mL) |
| Burette Fill/Empty Time | ~30 s |
| Dimensions | 200 × 200 × 260 mm |
| Weight | 4.3 kg |
| Brand | SOP TOP |
|---|---|
| Model | CON6300 |
| Conductivity Range | 0–5.000 µS/cm, 0–50.00 µS/cm, 0–500.0 µS/cm, 0–5000 µS/cm, 0–50.00 mS/cm, 0–500.0 mS/cm |
| TDS Range | 0–500 ppt |
| Salinity Range | 0–325 ppt |
| Conductivity Resolution | 0.001–1 µS/cm, 0.01 mS/cm |
| Conductivity Accuracy | ±1% of Full Scale |
| Resistivity Range | 0.00–18.30 MΩ·cm |
| Resistivity Resolution | 0.01 MΩ·cm |
| Temperature Range | −5.0–120.0 °C (23.0–248.0 °F) |
| Temperature Accuracy | ±0.3 °C, ±0.5 °F |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Temp. Compensation | Auto/Manual |
| Reference Temp. | 15.0–30.0 °C (default 25.0 °C) |
| Temp. Coefficient | 0.00–9.99% (default 2.00%) |
| TDS Factor | 0.40–1.00 (default 0.50) |
| Salinity Factor | 0.65 |
| Cell Constant Options | 0.01, 0.1, 1.0, 10.0 cm⁻¹ |
| Data Storage | 100 memory slots |
| Power | Rechargeable 3.7 V Li-ion battery (base-integrated, battery not included) |
| Interface | USB port for PC connectivity |
| Display | 5-inch multi-line LCD with high-brightness backlight |
| Features | Auto-hold, electrode diagnostics, temperature offset adjustment, key beep, programmable auto-off (default 10 min idle) |
| Brand | SOP TOP |
|---|---|
| Model | CON6301 |
| Conductivity Range | 0–5.000 µS/cm, 0–50.00 µS/cm, 0–500.0 µS/cm, 0–5000 µS/cm, 0–50.00 mS/cm, 0–500.0 mS/cm |
| TDS Range | 0–500 ppt |
| Salinity Range | 0–325 ppt |
| Conductivity Resolution | 0.001–1 µS/cm, 0.01 mS/cm |
| Conductivity Accuracy | ±1% of Full Scale |
| Resistivity Range | 0.00–18.30 MΩ·cm |
| Resistivity Resolution | 0.01 MΩ·cm |
| Temperature Range | −5.0–120.0 °C (23.0–248.0 °F) |
| Temperature Accuracy | ±0.3 °C, ±0.5 °F |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Temp. Compensation | Auto/Manual |
| Reference Temp. | 15.0–30.0 °C (factory set at 25.0 °C) |
| Temp. Coefficient | 0.00–9.99% (factory default 2.00%) |
| TDS Factor | 0.40–1.00 (factory default 0.50) |
| Salinity Factor | 0.65 |
| Cell Constant Options | 0.01, 0.1, 1.0, 10.0 cm⁻¹ |
| IP Rating | IP67 |
| Data Storage | 100 measurement records |
| Power | 2 × 1.5 V AA batteries |
| Auto-Off | Configurable (default: 10 min idle) |
| Brand | SOP TOP |
|---|---|
| Model | DO35 |
| Type | Portable Electrochemical Dissolved Oxygen Meter |
| Measurement Principle | Clark-type Polarographic Membrane Electrode |
| Display | Multi-line LED with backlight (22 × 32 mm) |
| Protection Rating | IP67 |
| Power Supply | 1 × AA alkaline battery (1.5 V) |
| Auto-off | 6 min inactivity with data retention |
| Data Storage | 10 measurement records |
| Operating Temperature | 0–60.0 °C (32–140.0 °F) |
| DO Range | 0.00–20.00 mg/L and 0.0–200.0 % saturation |
| Resolution | 0.01 mg/L, 0.1 %, 0.1 °C, 1 °F |
| Accuracy | ±1.5 % of full scale |
| Temperature Compensation | Automatic or manual |
| Atmospheric Pressure Compensation | 600–1100 mbar |
| Salinity Compensation | 0.0–140.0 ppt |
| Calibration | 1-point or 2-point (air-saturated water or zero-oxygen solution) |
| Hold Function | Yes |
| Low-Battery Indicator | Yes |
| Brand | SOP TOP |
|---|---|
| Origin | Shanghai, China |
| Model | DO6400 |
| Measurement Range | 0.00–40.00 mg/L, 0.0–400.0% |
| Resolution | 0.01 mg/L, 0.1% |
| Accuracy | ±1.5% F.S. |
| Temperature Range | −5.0–120.0 °C (23.0–248.0 °F) |
| Temp. Resolution | 0.1 °C/°F |
| Temp. Accuracy | ±0.3 °C, ±0.5 °F |
| Salinity Compensation | 0.0–45.0 ppt |
| Pressure Compensation | 450–800 mmHg (0.500–1.100 bar) |
| Pipeline Pressure Compensation | 0.00–1.00 kg |
| Depth Compensation | 0.0–10.0 m |
| Data Storage | 100 sets |
| Auto-off | Configurable (default: 10 min idle) |
| Brand | SOP TOP |
|---|---|
| Model | ION6500 |
| Type | Benchtop Ion-Selective Electrode (ISE) Meter |
| Measurement Principle | Potentiometric Ion-Selective Electrode Detection |
| pH Range | −2.000 to 20.000 |
| mV Range | −2000.0 to +2000.0 mV |
| Ion Concentration Range | 0.000–9999 mg/L |
| Temperature Range | −10.0 to 120.0 °C (14.0–248.0 °F) |
| Resolution | 0.001 pH / 0.1 mV / 0.001 mg/L / 0.1 °C / 0.1 °F |
| Accuracy | ±0.001 pH / ±0.2 mV / ±0.005 mg/L / ±0.3 °C / ±0.5 °F |
| Calibration | Up to 5-point pH, up to 7-point ISE |
| Data Storage | 1000 measurement records |
| Interface | USB-B port for PC connectivity |
| Power | Internal rechargeable 3.7 V Li-ion battery (battery not included) |
| Display | 5-inch LED, 120° viewing angle |
| Compliance | Designed per IEC 61010-1 for laboratory electrical safety |
| Software | Included Windows-compatible data acquisition software with audit trail logging capability |
| Brand | SOP TOP |
|---|---|
| Model | ION6501 |
| Type | Portable Electrochemical Ion Analyzer |
| Measurement Principles | Potentiometric Ion-Selective Electrode (ISE) Method |
| pH Range | −2.000 to 20.000 pH |
| mV Range | −2000.0 to +2000.0 mV |
| Ion Concentration Range | 0.000–9999 mg/L (ion-specific, dependent on calibrated ISE) |
| Temperature Range | −10.0 to 120.0 °C (14.0 to 248.0 °F) |
| Temperature Compensation | Automatic or Manual |
| Resolution | 0.001 pH / 0.1 mV / 0.001 mg/L / 0.1 °C / 0.1 °F |
| Accuracy | ±0.001 pH / ±0.2 mV / ±0.005 mg/L / ±0.3 °C / ±0.5 °F |
| Calibration | Up to 5-point pH calibration |
| Calibration Reminders | Configurable interval (0–60 days) |
| Data Storage | 1000 measurement records with timestamp, user ID, instrument ID, and calibration metadata |
| Power Supply | 2 × 1.5 V AA alkaline batteries |
| Display | 3.2-inch multi-line LCD with anti-scratch coating and adjustable high-brightness backlight |
| Communication Interface | USB 2.0 compliant port |
| Software | Windows-compatible data acquisition software with audit trail logging capability |
| Auto-Power-Off | Programmable (default: 10 min idle timeout) |
| User Authentication | 4-digit password protection |
| Instrument & User ID Customization | 4-digit serial number + 2-digit user code |
| Date/Time Format Options | YY/MM/DD, MM/DD/YY, DD/MM/YY |
| Reading Lock Function | Enable/disable |
| Temperature Offset Adjustment | ±5.0 °C (±9.0 °F) |
| Real-time Calibration Diagnostics | Slope (%), offset (mV), and calibrated point count displayed during/after calibration |
| Brand | SOPOTOP |
|---|---|
| Origin | Shanghai, China |
| Model | DO6401 |
| Measurement Range | 0.00–40.00 mg/L and 0.0–400.0% saturation |
| Resolution | 0.01 mg/L, 0.1% |
| Accuracy | ±1.5% F.S. |
| Temperature Range | −5.0 to 120.0 °C (23.0 to 248.0 °F) |
| Temp. Resolution | 0.1 °C / 0.1 °F |
| Temp. Accuracy | ±0.3 °C / ±0.5 °F |
| Salinity Compensation | 0.0–45.0 ppt |
| Pressure Compensation | 450–800 mmHg or 0.500–1.100 bar |
| Pipe Pressure Compensation | 0.00–1.00 kg |
| Depth Compensation | 0.0–10.0 m |
| IP Rating | IP67 |
| Data Storage | 100 sets |
| Auto Power-Off | Configurable (default: 10 min inactivity) |
| Display | 3.2-inch multi-line LCD with anti-scratch coating |
| Power | 2 × 1.5 V AA batteries |
| Electrode Diagnostics | Offset & Slope display, self-diagnostic status |
| Connectivity | Optional USB interface |
| Software | Optional data acquisition software with PC compatibility |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | CON35 |
| Measurement Range | 0–200.0 µS/cm (ppm), 0–50.0 mS/cm (ppt) |
| Temperature Range | 0–60.0 °C / 32–140.0 °F |
| Temperature Compensation | Automatic or Manual |
| Resolution | 0.1 / 1 µS/cm (ppm), 0.1 / 1 mS/cm (ppt), 0.1 °C, 1 °F |
| Accuracy | ±1% F.S. |
| Temperature Coefficient Adjustment | 0.00–10.00% |
| TDS Conversion Factor | 0.40–1.00 |
| Salinity Factor | 0.65 |
| Electrode Material | PPS-encapsulated graphite conductivity sensor |
| Calibration | Single-point auto-ranging calibration |
| Data Storage | 10 measurement records |
| Ingress Protection | IP67 |
| Display | Multi-line LED, 22 × 32 mm active area with energy-efficient backlight |
| Power Supply | 1 × AA alkaline battery (1.5 V) |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | FCL35 |
| Detection Parameter | Free Chlorine (Single-Parameter) |
| Form Factor | Pen-Type Portable Analyzer |
| Measurement Range | 0.05–10.00 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ±1% F.S. |
| Temperature Range | 0.0–60.0 °C |
| Calibration | Two-Point (0 ppm + User-Selectable Standard) |
| Display | 22 × 32 mm Multi-Line LCD with Energy-Saving Backlight |
| Data Storage | 10 Sets |
| IP Rating | IP67 |
| Power Supply | 1 × AA Alkaline Battery (1.5 V) |
| Auto-Power-Off | After 6 min of inactivity with data retention |
| Brand | SOPTOP |
|---|---|
| Model | ORP35 |
| Measurement Range | −900 to +900 mV |
| Temperature Range | 0.0–60.0 °C (32.0–140.0 °F) |
| Temperature Compensation | Automatic or Manual |
| Resolution | 1 mV, 0.1 °C, 0.1 °F |
| Accuracy | ±1 mV |
| Calibration | Auto-recognition of standard buffer solutions |
| Electrode Type | Flat-surface platinum ORP electrode |
| Data Storage | 10 measurement records |
| Display | Multi-line LED, 22 × 32 mm active area with energy-efficient backlight |
| Ingress Protection | IP67 |
| Power Supply | 1 × AA alkaline battery (1.5 V) |
| Auto-power-off | After 6 minutes of inactivity with data retention |
| Hold Function | Manual reading freeze |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | pH6220 |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH/mV/Temperature) |
| pH Range | -2.00 to 16.00 pH |
| mV Range | -2000 to +2000 mV |
| Temperature Range | -5.0 to 120.0 °C |
| Temperature Compensation | Automatic or Manual |
| pH Resolution | 0.01 pH |
| mV Resolution | 0.1 mV |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| pH Accuracy | ±0.01 pH |
| mV Accuracy | ±0.2 mV |
| Temperature Accuracy | ±0.3 °C / ±0.5 °F |
| Calibration Points | Up to 5-point NIST-traceable calibration (China-specific NIST-type buffers) |
| Data Storage | 100 measurement records |
| Auto-Power-Off | Configurable (default: 10 min inactivity) |
| Display | 5-inch LED, 120° viewing angle |
| Power | USB-powered base with integrated rechargeable 3.7 V Li-ion battery compartment (battery not included) |
| Interface | USB communication port |
| Software | Included data acquisition software (CD-based) |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | PH6221 |
| Instrument Type | Portable |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | -2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Standards | NIST-traceable buffer solutions |
| mV Range | -2000 to +2000 mV |
| Temperature Range | -5.0 to 120.0 °C (23.0 to 248.0 °F) |
| Temperature Compensation | Automatic or Manual |
| Calibration Points | Up to 5-point calibration |
| Data Storage | 100 measurement records |
| Display | 3.2-inch multi-line LCD with anti-scratch coating |
| Power Supply | 2 × 1.5 V AA batteries |
| IP Rating | IP65 |
| Backlight | Adjustable high-brightness LED |
| Auto-power-off | Configurable (default: 10 min inactivity) |
| Electrode Diagnostics | Real-time slope and offset display |
| Connectivity | Optional USB interface |
| Software | Optional data acquisition software with PC compatibility |
| Brand | SOPTOP |
|---|---|
| Model | pH6230 |
| Type | Benchtop |
| Parameter Type | Single-Parameter (pH/mV/Temperature) |
| pH Range | -2.000 to 20.000 pH |
| pH Resolution | 0.001 pH |
| pH Accuracy | ±0.001 pH |
| mV Range | -2000.0 to 2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.2 mV |
| Temperature Range | -10.0 to 120.0 °C (14.0 to 248.0 °F) |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Temperature Accuracy | ±0.3 °C / ±0.5 °F |
| Calibration | Up to 5-point NIST-traceable buffer calibration |
| Temperature Compensation | Automatic or Manual |
| Data Storage | 750 measurement records |
| Display | 5-inch LED, 120° viewing angle |
| Power | USB-powered base with integrated rechargeable 3.7 V Li-ion battery compartment (battery not included) |
| Interface | USB communication port |
| Software | Included PC-based data acquisition software (CD provided) |
| Backlight | Adjustable high-brightness LED backlight |
| Auto-Off | Configurable (default: 10 min inactivity) |
| Password Protection | 4-digit user-defined password |
| User ID & Instrument ID | Customizable (4-digit instrument ID, 2-digit user ID) |
| Date/Time Format | YY/MM/DD, MM/DD/YY, DD/MM/YY |
| Calibration Reminder | 0–60 days adjustable |
| Slope & Offset Display | Real-time calibration diagnostics |
| Reading Lock | Enable/disable |
| Temperature Offset Adjustment | ±5.0 °C / ±9.0 °F |
| Brand | SOPTOP |
|---|---|
| Model | pH6231 |
| Type | Portable pH Meter |
| Parameter Type | Single-Parameter (pH/mV/Temperature) |
| Measurement Range | −2.000 to 20.000 pH |
| Resolution | 0.001 pH |
| Accuracy | ±0.001 pH |
| mV Range | −2000.0 to +2000.0 mV |
| mV Accuracy | ±0.2 mV |
| Temperature Range | −10.0 to 120.0 °C |
| Temp. Accuracy | ±0.3 °C |
| Temperature Compensation | Automatic or Manual |
| Calibration Points | Up to 5-point NIST-traceable buffer calibration |
| Data Storage | 750 sets with timestamp, instrument ID, and user ID |
| Display | 3.2-inch multi-line LCD with adjustable backlight |
| Power | 2 × 1.5 V AA batteries |
| Auto-Off Delay | Configurable (default: 10 min idle) |
| Interface | USB port for data transfer |
| Compliance | NIST-traceable calibration support |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SP1-12012 Self-Adhesive Quartz Crystal Holder |
| Pricing | Upon Request |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP1-24018 Self-Adhesive Quartz Crystal Carrier Box |
| Pricing | Upon Request |
| External Dimensions | 240 mm × 120 mm × 18 mm |
| Internal Dimensions | 235 mm × 115 mm × 13 mm |
| Lid/Bottom Height | 9 mm / 9 mm |
| Adhesion Strength | Selectable Low or High |
| Material | Ultra-Clean Polymer Adhesive Layer + Rigid Polycarbonate Housing |
| Optical Transparency | Fully Transparent or Black Opaque Variant Available |
| Compatibility | Standard AT-cut quartz crystal resonators (5–14 mm diameter), SAW/BAW substrates, and thin-film sensor wafers |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SP1-8512 Self-Adhesive Quartz Crystal Holder |
| Pricing | Upon Request |
| Dimensions (OD) | 85 mm × 85 mm × 12 mm |
| Dimensions (ID) | 81 mm × 81 mm × 8.5 mm |
| Lid/Bottom Height | 6 mm each |
| Adhesion Strength | Low or High Option |
| Transparency | Clear or Black Variant |
| Material | High-Purity Polymer Adhesive Layer + Rigid Polypropylene Housing |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SP3-3818 |
| Pricing | Upon Request |
| Brand | Spectrum |
|---|---|
| Origin | USA |
| Model | 2266FS |
| Portability | Portable |
| Conductivity Ranges | 0.0–200.0 µS/cm |
| Resolution | 0.1 µS/cm |
| Accuracy | ±1% of full scale |
| Temperature Range | 0–60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C (0–50 °C), ±1.0 °C (50–60 °C) |
| Automatic Temperature Compensation (ATC) | Yes |
| Ingress Protection | IP67 |
| Power | 4 × AAA 1.5 V batteries |
| Battery Life | >150 hours |
| Brand | Admiral Instruments |
|---|---|
| Origin | USA |
| Model | Squidstat Prime |
| Instrument Type | Multi-Channel Potentiostat/Galvanostat |
| Number of Channels | 4 Independent Channels |
| Voltage Range per Channel | ±10 V |
| Current Range per Channel | ±250 mA |
| Current Resolution | 750 fA (0.003% of range) |
| Voltage Resolution | 33 µV |
| Input Impedance | 10 TΩ |
| ADC Resolution | 16-bit |
| Maximum Sampling Rate | 40,000 samples/s |
| Onboard Memory | 16 GB |
| Electrode Configurations Supported | 2-, 3-, 4-, and 5-electrode cells |
| Cable Length | 90 cm |
| Operating Modes | Potentiostatic, Galvanostatic, Zero Resistance Ammeter (ZRA) |
| Grounding Options | Grounded or Floating |
| Electrochemical Techniques Supported | CV, LSV, OCP, Tafel, Potentiodynamic Polarization, CA, CC, CP, CR, DPV, NPV, SWV, Staircase Voltammetry, GITT, PITT, CC-CV Cycling, dQ/dV Analysis, Coulombic Efficiency Calculation, State-of-Charge (SOC) Tracking, Energy Efficiency Metrics, Charge/Discharge Time & Capacity Statistics |
| EIS Frequency Range | 10 µHz to 1 MHz (typical) |
| Current Accuracy | ±0.1% of full scale, down to 10 nA |
| Potential Accuracy | ±0.1% of full scale, within ±1 mV |
| Maximum Impedance Measurement | 5 GΩ (typical) |
| Brand | Admiral |
|---|---|
| Origin | USA |
| Model | Squidstat Prime |
| Instrument Type | Benchtop Multi-Channel Electrochemical Workstation |
| Number of Channels | 4 Independent Channels |
| Current Range per Channel | ±250 mA |
| Current Resolution | 750 fA (0.003% of range) |
| Current Accuracy | 0.1% of full scale, down to 10 nA |
| Potential Range | ±10 V |
| Potential Accuracy | ±1 mV (0.1% of range) |
| Potentiostatic/Galvanostatic/ZRA Modes | Yes |
| Input Impedance | 10 TΩ |
| ADC Resolution | 16-bit |
| Sampling Rate | 40 kS/s |
| Onboard Memory | 16 GB |
| Electrode Configurations Supported | 2-, 3-, 4-, and 5-electrode |
| Standard Cable Length | 90 cm |
| AC Impedance Frequency Range | 10 µHz – 1 MHz (typical, dependent on cell configuration) |
| Compliance | ASTM G5, G59, G102 |