Electrochemical Instruments
Filter
Showing 1471–1500 of 1703 results
| Brand | Admiral |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Squidstat Solo |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±100 mA |
| Current Accuracy | 0.2% of full scale, down to 20 nA |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SrLaGaO4 |
| Price | Upon Request |
| Growth Method | Czochralski (CZ) |
| Crystal Structure | Tetragonal |
| Lattice Parameters | a = 3.843 Å, c = 12.680 Å |
| Dielectric Constant (εᵣ) | 16–20 |
| Melting Point | ~1600 °C |
| Density | 4.88 g/cm³ |
| Surface Roughness (RMS) | < 5 Å |
| Lattice Mismatch vs. YBCO | 5.7% |
| Orientation Options | <100>, <001> |
| Orientation Tolerance | ±0.5° |
| Surface Finish | Single-Polished, Double-Polished |
| Standard Dimensions | 10 × 10 × 0.5 mm, 5 × 5 × 0.5 mm |
| Customization | Available for orientation, thickness, and geometry |
| Packaging | Class 1000 cleanroom processed |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Sr-TiO3 |
| Pricing | Available Upon Request |
| Crystal Structure | Cubic |
| Lattice Constant | a = 3.905 Å |
| Growth Method | Flame Fusion (Verneuil) |
| Melting Point | 2080 °C |
| Density | 5.175 g/cm³ |
| Mohs Hardness | 6 |
| Thermal Expansion Coefficient | 9.4 × 10⁻⁶ /°C |
| Dielectric Constant | ~300 (300 K) |
| Loss Tangent | ~5 × 10⁻⁴ (300 K), ~3 × 10⁻⁴ (77 K) |
| Appearance | Transparent (slight brown tint possible depending on annealing history) |
| Chemical Stability | Insoluble in water |
| Orientation Angles | 10°, 24°, 36° (misorientation between two single-crystal domains) |
| Dimensions | 10 × 10 × 0.5 mm, 10 × 5 × 0.5 mm, 5 × 5 × 0.5 mm |
| Surface Finish | Single-side polished, Ra < 0.5 nm |
| Packaging | Class 1000 cleanroom processed |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SRX-CT23 |
| Price Range | USD 280–690 |
| Instrument Type | Electrochemical Electrode |
| Brand | SRS/Stanford Research Systems |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | QCM200 System |
| Pricing | Available Upon Request |
| Measurement Accuracy | ±1.5 ppm |
| Minimum Detectable Mass Change | 1 ng |
| Operating Frequency | >5 MHz |
| Interface | RS-232 |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | 884 |
| Price Range | USD 14,000–28,000 |
| Key Measurement Modes | DPV, NPV, DCV, SWV, ACV (1st & 2nd), CV, PSA, CCPSA, CVS, CPVS |
| Potential Range | ±5 V |
| Max Output Potential | ±12 V |
| Max Output Current | ±80 mA |
| Scan Rate | 1 mV/s–3 V/s (1 mV resolution) |
| Current Measurement Range | 10 nA–10 mA (7 decades) |
| Electrode Support | Metrohm Multi-Mode Electrode (MME), Rotating Disk Electrodes (Au, Pt, GC, Ag, Graphite) |
| Interface | USB |
| Compliance | GLP-ready with user authentication, audit trail, electrode self-test, and automated calibration logging |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Origin Category | Domestic (China) |
| Model | InnoCon 60C |
| Detection Parameters | Conductivity, Salinity, TDS, Resistivity, Temperature |
| Portability | Benchtop |
| Intended Use | Laboratory |
| Conductivity Range | 0–5.000 / 50.00 / 500.0 / 5000 µS/cm |
| TDS Range | 0–500 ppt |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–325 ppt |
| Temperature Range | 5–55 °C |
| Accuracy | ±1% of Full Scale |
| Minimum Resolution | 0.001 / 0.01 / 0.1 / 1 µS/cm |
| Temperature Compensation | Automatic (adjustable TC coefficient: 0.00–9.99%, factory default 2.00%) |
| Data Storage | 100 measurement records |
| Power Supply | Rechargeable Li-ion battery with AC adapter |
| Interface | USB-B for PC connectivity |
| Display | Backlit LCD with adjustable brightness and keypress tone |
| Electrode Diagnostics | Real-time electrode status indication |
| Auto Power-Off | Configurable timeout (default: 10 min) |
| Calibration | Manual 1–3 point calibration with user-defined standards |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SDW-4334 |
| Price Range | USD 2,800 – 7,000 |
| Heating Capacity | 4 independent stations (500 W each) |
| Max Operating Temperature | 400 °C |
| Compliance | GB/T 4334–2020 (including optional Method A) |
| Control System | PLC + PID temperature regulation |
| Cooling | Integrated reflux condensation system with auto-recirculation |
| Safety Features | Low-coolant alarm, auto-shutdown, power-interruption resume function |
| Power Supply | 2000 W total |
| Optional Modules | ICT-W closed-loop chiller, ICT-M Wi-Fi remote monitoring, ICT-S SMS-based remote control, ICT-A sensitization test kit, acid fume extraction cabinet |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | BV-10 |
| Instrument Type | Microelectrode Processing System for Electrophysiology |
| Heating Elements | Pt/Ir wire and Sn-Pb alloy wire |
| Tip Diameter Capability | < 0.3 µm |
| Control | Triple independent digital controllers for heat, pull force, and timing |
| Microscopy | Integrated dual-magnification optical system (low- and high-power objectives) |
| Compliance | Designed for GLP-compliant electrophysiology lab workflows |
| Brand | Sutter Instrument |
|---|---|
| Origin | USA |
| Product Line | Capillary Glass & Filaments |
| Wall Type Options | Standard Wall, Thin Wall, Multibarrel, Quartz |
| Material | Borosilicate Glass (e.g., 7052, 7740) and Fused Quartz |
| Outer Diameter Range | 1.00–2.00 mm |
| Inner Diameter Range | 0.30–1.56 mm |
| Length Options | 7.5 cm, 10 cm, 15 cm |
| Packaging Quantities | 75–250 units per pack |
| Filament Availability | With or Without Internal Filament |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Product Type | Replacement Filament Heating Elements |
| Compatible Models | P-1000, P-97, P-87, P80PC, P80C, PC-84, P-77B, P-30, P-2000, P-77A |
| Filament Types | Box (square), Trough (rectangular), Loop, Custom Pt/Ir, Nichrome |
| Dimensions Range | 1.5–4.5 mm width |
| Material Options | Kanthal A1, Nichrome, Platinum/Iridium alloy |
| Packaging | Minimum order quantity = 4 filaments |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MP85 / MP285 / MP-33 |
| Type | Electrochemical Sample Manipulator |
| Axes | 3–4 axis (manual or motorized) |
| Positioning Resolution | Down to 62.5 nm (MP-285/MP-225), 0.2 µm (MP-85 ultra-fine), 0.01 mm (MP-33 fine), 0.1 mm (coarse) |
| Drift | <10 nm/h (MP-285, 24°C), <1 µm/h (MPC-325-2/MPC-385-2) |
| Travel Range | Up to 25 mm (X/Y/Z/oblique), 1 inch (MP-285), 37 × 20 × 20 mm (MP-33 coarse) |
| Control Interface | RS-232 serial, software-driven (XenoWorks™ compatible) |
| Compliance | Designed for GLP/GMP-aligned electrophysiology and electrochemical microelectrode positioning |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MPC-200 / MPC-385 / MPC-325 |
| Drive Type | Motorized (DC servo) |
| Position Resolution | ≤ 10 nm (closed-loop) |
| Travel Range (X/Y/Z) | 25 mm × 25 mm × 25 mm (standard) |
| Repeatability | ±0.1 µm |
| Max Load Capacity | 250 g |
| Compatibility | Standard micropipette holders (e.g., Sutter MO-103, MO-203), compatible with upright & inverted microscopes |
| Interface | Analog voltage input (±10 V), RS-232, optional USB-to-serial adapter |
| Operating Temperature | 15–30 °C |
| Humidity | 20–80% RH (non-condensing) |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-30 |
| Heating Element Options | Platinum-Iridium or Nichrome Coil |
| Control Interface | Three Digital Knobs (Heat, Pull, Velocity) |
| Precision Mechanism | Micrometer-Based Pull Length Reproducibility |
| Electrode Tip Diameter | Down to <0.3 µm |
| Power Supply | Constant-Current Source for Heater and Pull Solenoid |
| Dual-Step Heating Mode | Yes |
| RFI Filtering | Integrated |
| Mounting Base | Rubber-Pad Clamping System |
| Construction Materials | Corrosion-Resistant Alloys and Ceramics |
| Voltage/Frequency Options | Dual (115 V / 230 V |
| Application Domain | Intracellular Electrophysiology, Patch-Clamp Recording, Microinjection, Single-Cell Manipulation |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P97 |
| Instrument Type | Electrochemical Micropipette Fabrication System |
| Heating Element | Dual-Loop Resistive Wire (NiChrome or Platinum) |
| Control Architecture | Embedded Microprocessor with Non-Volatile Program Memory |
| Max. Program Storage | 100 Protocols |
| Display | Vacuum Fluorescent Display (VFD), Omnidirectional View |
| Environmental Control | Integrated Humidity-Stabilized Chamber |
| Cooling Options | Pneumatic Blast Cooling (Selectable Mode) |
| Glass Compatibility | Single- and Multi-Barrel Capillaries (OD up to 2.0 mm) |
| Tip Diameter Resolution | Sub-100 nm (Typical for Borosilicate & Aluminosilicate Glass) |
| Compliance | Designed for GLP/GMP-Adjacent Electrophysiology Labs |
| Software Features | Date/Time-Stamped Protocol Logging, Write-Protected Program Mode, Atmospheric Pressure Compensation Parameter |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XenWorks |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T11 |
| Price Range | USD 700 – 7,000 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 0–14 |
| mV Measurement Range | ±2000 mV |
| pH Resolution | 0.01 |
| mV Resolution | 0.1 mV |
| pH Accuracy | ±0.01 |
| mV Accuracy | ±0.2 mV |
| Titration Accuracy | ±0.15% (10 mL), ±0.2% (20 mL) |
| Minimum Dispensing Volume | 10 µL |
| Stepper Motor Resolution | 1/60,000 steps |
| Temperature Interface | Pt1000 (Resolution: 0.1 °C, Max Error: ±0.2 °C) |
| Electrode Interfaces | 2 x indicator electrode, 2 x reference electrode, 2 x polarizable electrode |
| Color Sensor | 16-bit RGB tri-color sensor |
| Dimensions | 200 × 200 × 260 mm |
| Weight | 4.3 kg |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | TbScO₃ Single Crystal Substrate |
| Price | Upon Request |
| Crystal Structure | Orthorhombic (Space Group: Pbnm) |
| Lattice Parameters | a ≈ 5.52 Å, b ≈ 5.70 Å, c ≈ 7.88 Å |
| Melting Point | ~2120 °C |
| Density | ~6.8 g/cm³ |
| Growth Method | Czochralski (Cz) |
| Orientation | <110> ± 0.5° |
| Dimensions | 10 × 10 × 0.5 mm³ or 5 × 5 × 0.5 mm³ |
| Surface Finish | Single-side polished |
| Surface Roughness (Ra) | < 0.5 nm |
| Packaging | Vacuum-sealed in Class 100 cleanroom bags, stored and shipped from Class 1000 cleanroom environment |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TCL-1B |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Cement Chloride Ion Analysis Dedicated |
| Measurement Range | mV: −2000 to +2000 mV |
| pH | 0.000–14.000 |
| Temperature | −55.0 to +125.0 °C |
| Meter Accuracy | ±0.5% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Precision | ≤0.8 mV/h |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 2051 |
| Instrument Type | Portable |
| Parameter Types | pH & Temperature |
| pH Range | 0–14 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| Temperature Range (NTC) | 0–60 °C (short-term up to +80 °C for ≤5 min) |
| Temperature Accuracy | ±0.4 °C |
| Temperature Resolution | 0.1 °C |
| Calibration | 1-, 2-, or 3-point with NIST-traceable buffers |
| Electrolyte | Replaceable gel electrolyte |
| Probe Tip Diameter | 11 mm |
| Probe Shaft Length | 25 mm |
| Display | Dual-line backlit LCD |
| Housing Material | ABS |
| Protection Rating | IP65 |
| Weight | 135 g |
| Dimensions (L×W×H) | 145 × 38 × 167 mm |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–+70 °C |
| Battery | LR44 button cell (≈80 h operation) |
| Compliance | CE 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 2061 |
| Instrument Type | Pen-style pH Meter |
| Parameters Measured | pH and Temperature |
| pH Range | 0–14 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| Temperature Range (NTC) | 0–60 °C (short-term up to 80 °C for ≤5 min) |
| Temperature Accuracy | ±0.4 °C |
| Temperature Resolution | 0.1 °C |
| Calibration Standard | NIST-traceable buffer solutions |
| IP Rating (with TopSafe protective sleeve) | IP68 |
| Weight | 69 g |
| Dimensions (L×W×H) | 197 × 33 × 20 mm (including probe and TopSafe) |
| Display | 2-line LCD with backlight |
| Power Supply | 1 × CR2032 battery (≈80 h operating time) |
| Housing Material | ABS |
| Operating Temperature | 0–60 °C |
| Storage Temperature | −20–+70 °C |
| Compliance | CE 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 2061 |
| Instrument Type | Pen-style |
| Parameter Types | Dual-parameter (pH + temperature) |
| pH Measurement Range | 0–14 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| Temperature Range (NTC) | 0 to +60 °C (short-term up to +80 °C for ≤5 min) |
| Temperature Accuracy | ±0.4 °C |
| Temperature Resolution | 0.1 °C |
| Calibration Solution Standard | NIST-traceable |
| Protection Rating (with TopSafe sleeve) | IP68 |
| Weight | 69 g |
| Dimensions (L×W×H) | 197 × 33 × 20 mm (with probe and TopSafe) |
| Display | Backlit 2-line LCD |
| Battery | CR2032 (≈80 h operation) |
| Operating Temperature | 0 to +60 °C |
| Storage Temperature | −20 to +70 °C |
| Housing Material | ABS |
| Compliance | CE 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 2062 |
| Instrument Type | Pen-style pH Meter |
| Parameter Types | pH + Temperature (NTC) |
| pH Range | 0–14 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| Temperature Range | 0–+60 °C (short-term up to +80 °C for ≤5 min) |
| Temperature Accuracy | ±0.4 °C |
| Temperature Resolution | 0.1 °C |
| Calibration | 1-, 2-, or 3-point with NIST-traceable buffer solutions |
| Electrode Type | Integrated gel-filled pH electrode with annular transparent reference junction |
| Probe Diameter | 11 mm |
| Probe Sleeve Length | 35 mm |
| IP Rating | IP68 |
| Display | 2-line LCD |
| Power | 1 × CR2032 battery (≈80 h operation) |
| Weight | 115 g (with TopSafe protective sleeve), 65 g (without) |
| Dimensions | 197 × 33 × 20 mm (L×W×H, with probe & sleeve) |
| Housing Material | ABS |
| Operating Temperature | 0–+60 °C |
| Storage Temperature | −20–+70 °C |
| Compliance | CE 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 2062 |
| Instrument Type | Pen-Style |
| Parameter Types | pH & Temperature |
| Measurement Accuracy | ±0.02 pH |
| pH Range | 0–14 pH |
| pH Resolution | 0.01 pH |
| Temperature Range (NTC) | 0–60 °C (short-term up to 80 °C, max 5 min) |
| Temp. Accuracy | ±0.4 °C |
| Temp. Resolution | 0.1 °C |
| Calibration | 1-, 2-, or 3-point with automatic buffer recognition |
| Calibration Standard | NIST-traceable buffers |
| Protection Rating | IP68 |
| Electrode Type | Integrated gel-filled ring-electrode with built-in temperature sensor |
| Probe Shaft Diameter | 11 mm |
| Sleeve Length | 35 mm |
| Weight | 115 g (with TopSafe protective sleeve), 65 g (without) |
| Dimensions | 197 × 33 × 20 mm (L×W×H, with probe & sleeve) |
| Display | 2-line LCD |
| Battery | CR2032 (≈80 h operation) |
| Housing Material | ABS |
| Operating Temperature | 0–60 °C |
| Storage Temperature | −20–+70 °C |
| CE Marked | 2014/30/EU |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ECtestr 11+ |
| Conductivity Range | 0–200.0 µS/cm, 0–2000 µS/cm, 0–20.00 mS/cm |
| Resolution | 0.1 µS/cm, 1 µS/cm, 0.01 mS/cm |
| Accuracy | ±1% of full scale |
| Calibration Points | 3-point (auto/manual) |
| Temperature Range | 0–50.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| TDS Conversion Factor | Adjustable (0.40–1.00) |
| Sensor Material | SS316 stainless steel with Valox protective housing |
| Ingress Protection | IP67 |
| Power | Replaceable batteries |
| Battery Status Retention | Calibration settings retained after battery replacement |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Benchtop Conductivity Meter |
| Model | Eutech CON700 |
| Measurement Parameters | Conductivity, TDS, Temperature |
| Conductivity Range | 0 μS/cm to 200.0 mS/cm |
| TDS Range | 0–100 ppt (TDS factor 0.5) |
| Temperature Range | 0.0–100.0 °C |
| Accuracy | ±1% of full scale |
| Resolution | 0.01 / 0.1 / 1 μS/cm |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Calibration Points | Up to 5-point conductivity/TDS calibration |
| Data Storage | 100 measurement records |
| Electrode Compatibility | 2-cell or 4-cell conductivity cells (K = 0.1, 1.0, 10.0 cm⁻¹) |
| Auto-Endpoint Detection | Yes |
| Temperature Compensation | Automatic or manual (linear, 0.00–10.00%/°C) |
| Reference Temperature | 15.0–30.0 °C |
| Display | Dual-line LCD (5.6 × 7.5 cm), large-font numeric readout |
| Power Supply | 9 V DC regulated adapter (100–240 VAC, SMPS) |
| Dimensions (H×W×D) | 17.5 × 15.5 × 6.9 cm |
| Weight | 650 g (instrument only) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher Scientific brand) |
| Model | pH 6+ |
| Type | Portable Electrochemical Meter |
| Measurement Modes | pH, ORP (mV), Relative mV (RmV), Temperature |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Calibration Points | Up to 3-point auto-buffer recognition (USA, NIST, Pure Water) |
| ORP/RmV Range | ±1000.0 mV |
| ORP/RmV Resolution | 0.1 mV (±199.9 mV), 1 mV (>±199.9 mV) |
| ORP Accuracy | ±0.2 mV (±199.9 mV), ±2 mV (>±199.9 mV) ±1 LSD |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Compensation | Automatic or Manual (0.0–100.0 °C) |
| Display | Dual-line LCD (4.5 × 2.3 cm) |
| Power | 4 × 1.5 V AAA alkaline batteries |
| Battery Life | >500 hours |
| Auto-Off | 20 min inactivity |
| Dimensions (Instrument) | 15.7 × 8.5 × 4.2 cm |
| Weight (Instrument) | 255 g |
| Input Connectors | BNC + 2.5 mm phono sockets |
| Operating Environment | 0–50 °C, ≤85% RH non-condensing |
| Enclosure Rating | IP67-rated rubber boot included |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Salt6+ |
| Measurement Principle | Conductivity-based salinity determination with automatic temperature compensation (ATC) |
| Salinity Range | 1.0–50.0 ppt / 0.1–5.00% |
| Salinity Resolution | 0.1 ppt / 0.01% |
| Salinity Accuracy | ±1% of full scale |
| Temperature Range | −10.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Compensation | ATC/MTC (0–50 °C) |
| Adjustable Temperature Coefficient | 0.0–3.0 %/°C |
| Reference Temperatures | 20.0 °C or 25.0 °C (selectable) |
| Cell Constant | 1.0 cm⁻¹ |
| Data Hold Function | Yes |
| Auto Power-Off | After 20 min of inactivity |
| Power Supply | 4 × 1.5 V AAA batteries |
| Dimensions (Instrument) | 14 × 17 × 3.5 cm |
| Weight (Instrument) | 200 g |
| Dimensions (Packaging) | 24 × 17 × 8 cm |
| Weight (Packaging) | 550 g |
| Compliance | Designed for GLP-compliant field and lab use |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | 3-Star |
| Price | Upon Request |
| pH Range | -2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| Calibration Points | 1–5-point with US/NIST, DIN, or Custom Buffers |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Temperature Range | -5 to 105 °C |
| Temperature Resolution | 0.1 °C (-5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Compensation | Automatic or Manual |
| Display | Backlit LCD |
| Electrode Interface | pH – BNC |
| Communication | Bidirectional RS232, optional USB cable |
| Data Logging | 1000 readings |
| Calibration History | Last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Password Protection | 10 user accounts |
| Power | 4×AA batteries |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| IP Rating | Benchtop – IP54 |
| Dimensions (Benchtop) | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| Dimensions (Portable) | 4.8 × 9.7 × 21.3 cm (H×W×L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Star A215 |
| Price | Upon Request |
| pH Range | –2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| pH Calibration | 1–5 points, NIST/US, DIN, or user-defined buffers |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Conductivity Range | 0.000 µS/cm to 3000 mS/cm |
| Conductivity Resolution | 4 significant digits, down to 0.001 µS/cm |
| Conductivity Accuracy | ±0.5% ±1 digit or ±0.01 µS/cm (whichever is greater) |
| Resistivity Range | 0.0001–100 MΩ·cm |
| Salinity | 0.01–80.0 ppt NaCl |
| TDS | 0–19999 mg/L |
| Cell Constant Range | 0.001–199.9 cm⁻¹ |
| Reference Temperatures | 5, 10, 15, 20, or 25 °C |
| Electrode Compatibility | Two-electrode, four-electrode, and planar conductivity cells |
| Temperature Range | –5 to 105 °C |
| Temperature Resolution | 0.1 °C (–5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Compensation | Automatic or manual |
| Display | Backlit LCD with icon-driven interface |
| Connectivity | BNC (pH), miniDIN (temperature), phono-jack (stirrer control for benchtop), RS232 (bidirectional), optional USB cable |
| Data Storage | 750 measurements |
| Calibration History | Last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Password Protection | Up to 10 user accounts |
| Power | 4×AA alkaline batteries (up to 2000 h in portable mode) |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| IP Rating | Benchtop — IP54 (dust-protected, splash-resistant) |
| Dimensions (Benchtop) | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| (Portable) | 4.8 × 9.7 × 21.3 cm (H×W×L) |