Environmental Monitoring Instruments
Filter
Showing 3211–3240 of 9112 results
| Brand | Hongweiliangzi |
|---|---|
| Model | HW-YHS |
| ORP Range | −2000 to +2000 mV, Resolution: 0.1 mV, Accuracy: ±10 mV |
| pH Range | 0–14, Resolution: 0.1, Accuracy: ±0.05 |
| Temperature Range | 5–60 °C, Resolution: 0.1 °C, Accuracy: ±1 °C |
| Power Supply | DC 5 V / 2 A |
| Battery Capacity | 6000 mAh |
| Data Storage | 5 million records |
| Display | 3.5-inch color touchscreen |
| IP Rating | IP65 |
| Compliance | HJ 746–2015, SL 94–1994 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hood IL-2700 |
| Price | Upon Request |
| Mariotte Reservoir Capacity | 5 L |
| Small Infiltration Ring Diameter | 16 cm |
| Large Infiltration Ring Diameter | 24 cm |
| U-Tube Manometer Range | −25 cm to +25 cm (resolution: 1 mm) |
| Data Logger Capacity | 2,000 measurements |
| Sampling Interval | 1 s (adjustable from 0–100 s) |
| Communication Interface | RS232 |
| Display | Integrated LCD screen |
| Dimensions (Packaging) | 90 × 51 × 31 cm |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Hood-Infiltrometer |
| Pricing | Available Upon Request |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HD-101 |
| Measurement Principle | Potassium Dichromate Oxidation–Spectrophotometric Method |
| Measurement Range | (15–1000) mg/L, (50–3000) mg/L, (200–10000) mg/L (expandable) |
| Zero Drift | ±5 mg/L |
| Span Drift | ±5% F.S. |
| Accuracy | ±10.0% of reading |
| Limit of Quantitation | 15 mg/L |
| Repeatability | ≤5.0% RSD |
| Cycle Time | ≤60 min |
| Insulation Resistance | >20 MΩ |
| MTBF | ≥720 h |
| Communication Interfaces | RS232 / RS485, 4–20 mA analog output |
| Dimensions (L×W×H) | 500 × 440 × 1440 mm |
| Weight | 55 kg |
| Display | 7-inch capacitive touchscreen |
| Controller | Industrial PLC-based embedded system |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–85% RH (non-condensing) |
| Power Supply | AC 220 V ±25%, 50 Hz ±0.5 Hz |
| Rated Power Consumption | 100 W |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HD-BTN |
| Price | USD 1,780 (FOB) |
| Measurement Method | Chromotropic Acid Spectrophotometry |
| Range | 0.5–200 mg/L |
| Resolution | 0.001 mg/L |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Model | HD-HW100A |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Target Gas | Carbon Monoxide (CO) |
| Multi-Component Capability | Yes |
| Repeatability | ≤1.0% |
| Response Time (T90) | ≤90 s |
| Linearity Error | ≤±2% F.S. |
| Operating Temperature Range | -10°C to 50°C |
| Data Storage Capacity | >100,000 records |
| Battery Life | >8 h (fully charged) |
| Display | 7-inch capacitive touchscreen (Android OS) |
| Connectivity | Wi-Fi, USB host/device, cloud platform integration |
| Calibration Options | N₂ zeroing & catalytic zeroing |
| Environmental Compensation | Integrated temperature & humidity sensors with real-time algorithmic correction |
| Flow Measurement | Optional digital mass flow sensor |
| Data Output | ppm / mg/m³ (user-switchable) |
| Regulatory Compliance | JJG635–2011, HJ965–2018, GB/T18204.2–2014, GB9801–1988, GBZ/T300.37–2017 |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XRF-SL1 |
| Price | ¥118,000 |
| Instrument Type | Handheld |
| Detection Principle | X-Ray Fluorescence Spectrometry (XRF) |
| Operating Temperature | −20 °C to 50 °C |
| Brand | HORDE Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XRF-ST1 |
| Product Type | Handheld |
| Detection Principle | Energy-Dispersive X-Ray Fluorescence (EDXRF) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 1512-10C |
| Measuring Range | 2.3–230,000 ppm Na⁺ |
| Compatible Reference Electrode | 2565A |
| Catalog Number | 3014068526 (9003016700) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 6560-10C |
| Measurement Range | 0.4–35,000 ppm Cl⁻ |
| Electrode Type | Composite (Integrated Reference) |
| Compatible Instruments | F-72, F-73, F-74, F-74BW, D-53 |
| Catalog No. | 3014093430 (Legacy: 9003014500) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 6561-10C |
| Measurement Range | 0.02–19,000 ppm F⁻ |
| Electrode Type | Composite (integrated reference), no external reference electrode required |
| Compatible Instruments | HORIBA F-72, F-73, F-74, F-74BW (benchtop) |
| Compliance | Designed for ASTM D1179, ISO 10304-1, and EPA Method 300.0 applications in water quality testing |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 6581-10C |
| Measuring Range | 0.62–62,000 ppm NO₃⁻ |
| Electrode Type | Composite (integrated reference) |
| Compatible Instruments | F-72, F-73, F-74, F-74BW (benchtop) |
| Interference Consideration | Performance affected by pH and coexisting ions (e.g., Cl⁻, SO₄²⁻, HCO₃⁻) |
| Part Number | 3014093432 (legacy: 9003014700) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 6582-10C |
| Measurement Range | 0.04–39,000 ppm K⁺ |
| Electrode Type | Composite (Integrated Reference) |
| Compatible Meters | HORIBA F-72 / F-73 / F-74 / F-74BW (benchtop), D-53 (portable) |
| Reference System | Built-in double-junction Ag/AgCl reference |
| Operating pH Range | 2.5–10.5 (K⁺-specific membrane unaffected by common interferents within this range) |
| Response Time | <30 seconds (t₉₀ in standard calibration solutions) |
| Temperature Range | 0–50 °C |
| Storage Solution | 0.1 M KCl or manufacturer-recommended storage buffer |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 6583-10C |
| Measuring Range | 0.4–40,080 ppm Ca²⁺ |
| Electrode Type | Composite ISE (Integrated Reference) |
| Compatible Instruments | F-72, F-73, F-74, F-74BW (benchtop) |
| Catalog No. | 3014093434 (9003014900) |
| Interference Consideration | pH range and coexisting ions affect measurement accuracy |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 8002-10C |
| Measuring Range | 0.4–35,000 ppm Cl⁻ |
| Reference Electrode | 2565A |
| Part Number | 3014094394 (9003015600) |
| Compatible With | F-72/F-73/F-74/F-74BW Benchtop Analyzers, D-53 Portable Analyzer |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 8010-10C |
| Measuring Range | 0.02–19,000 ppm F⁻ |
| Compatible Reference Electrodes | 2060A & 2565A |
| Part Number | 3014093439 (9003016400) |
| Compliance | Designed for ASTM D1179, ISO 10304-1, and EPA Method 300.0 applications |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 8201-10C |
| Measuring Range | 0.62–62,000 ppm NO₃⁻ |
| Reference Electrode | 2565A |
| Part Number | 3014094403 (9003016800) |
| Compatible Meters | F-72, F-73, F-74, F-74BW, D-53 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 8202-10C |
| Measuring Range | 0.04–39,000 ppm K⁺ |
| Reference Electrode | 2565A |
| Electrode Type | Non-Composite, Replaceable Sensing Element Design |
| Compliance | Designed for ASTM D1293, ISO 10523, and EPA Method 9055B applications |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 8203-10C |
| Measuring Range | 0.4–40,080 ppm Ca²⁺ |
| Compatible Reference Electrodes | 2060A and 2565A |
| Part Number | 3014068839 (9003017000) |
| Compliance | Designed for ASTM D511, ISO 10523, and EPA Method 300.0-compatible water analysis workflows |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9551-100D |
| Cable Length | 10 m |
| Operating Temperature Range | 0–40 °C |
| IP Rating | IP68 (submersible) |
| Electrode Type | Clark-type polarographic DO sensor |
| Compatibility | Designed for use with HORIBA LAQUA DO meters (e.g., LAQUA twin, LAQUA DO-110/210 series) |
| Calibration | Two-point (zero O₂ and air-saturated water) or single-point (air-saturation) |
| Response Time (t₉₀) | < 30 s in stirred water |
| Membrane | Replaceable Teflon® (PTFE) cap |
| Electrolyte | KCl-based aqueous electrolyte |
| Storage Condition | Wet storage in DO electrode storage solution or saturated KCl solution |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9551-20D |
| Cable Length | 2 m |
| Operating Temperature Range | 0–40 °C |
| IP Rating | IP68 (submersible) |
| Compatibility | Designed for use with HORIBA portable and benchtop DO meters (e.g., D-55, LAQUA twin series, or compatible analog input systems) |
| Electrode Type | Polarographic (Clark-type), membrane-covered, galvanic cell configuration |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9615-10D / 9625-10D |
| Construction | Integrated Glass pH Sensor, Reference Electrode, and Pt1000 Temperature Sensor |
| Body Material | 9615-10D — Glass Shaft |
| Membrane Type | ToupH Thick-Film Glass (9615-10D) |
| Internal Electrolyte | KCl 3.0 mol/L (Ref. #300) |
| Application Focus | Municipal drinking water, ultrapure water, low-buffered samples, field-deployable environmental monitoring |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9615S-10D |
| pH Range | 0–14 |
| Temperature Range | 0–100 °C |
| Temperature Sensor | Integrated Pt1000 or NTC (configurable) |
| Cable Length | 1 m |
| Connector | BNC + Phono (RCA) |
| Overall Length | 151 mm |
| Diameter | 12 mm |
| Fill Solution | 3.33 M KCl (HORIBA Ref. 525-3 or 300) |
| Construction | Lead-free thick-film glass membrane, waterproof IP67-rated body |
| Electrode Type | Refillable combination electrode |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 9630-10D |
| Price Range | USD 1,400–7,000 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Temperature Range | 0–50 °C |
| pH Range | 0–16 |
| Dissolved Oxygen (DO) | 0–50.00 mg/L (or 0–5000% saturation, depending on calibration mode) |
| Conductivity Range | 0–5000 µS/cm |
| Turbidity Range | 0–1000 NTU |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 5002A-10C |
| Measuring Range | 0.1–1000 ppm NH₃ |
| Electrode Type | Composite ISE (integrated reference) |
| Compatible Instruments | HORIBA F-72, F-73, F-74, F-74BW benchtop analyzers |
| Regulatory Compliance | Designed for ISO 5667-3, ASTM D1426, and EPA Method 350.1 applications |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APDA-370 |
| Measurement Principle | Beta-ray Attenuation Method |
| Measured Parameter | PM₁₀ |
| Range | 0–1000 / 5000 µg/m³ (standard) |
| Repeatability | ±20 µg/m³ @ 200/500 µg/m³ |
| Linearity | ±30 µg/m³ @ 200/500 µg/m³ |
| Zero Drift | ±20 µg/m³/day across all ranges |
| Span Drift | ±30 µg/m³/day @ low ranges |
| Sampling Flow Rate | ~16.7 L/min |
| Measurement Interval | 1 hour |
| Data Output | RS-232C, optional LAN (TCP/IP), analog 0–1 V, pulse & contact I/O |
| Power Supply | AC 100 V ±10 V, 50/60 Hz, ~200 VA |
| Dimensions | 430 × 483.5 × 266 mm (W×D×H) |
| Weight | Monitor unit: ~19 kg |
| Sampling pump | ~5 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APDA-370 |
| Measurement Principle | Beta-ray attenuation |
| Measured Parameters | PM2.5 and PM10 |
| Range | 0–1000/5000 µg/m³ (standard), up to 10,000 µg/m³ (custom configurations) |
| Repeatability | ±20 µg/m³ @ 200/500 µg/m³ |
| Linearity | ±30 µg/m³ @ 200/500 µg/m³ |
| Zero Drift | ±20 µg/m³/day across all ranges |
| Span Drift | ±30 µg/m³/day @ low ranges |
| Sampling Flow Rate | ~16.7 L/min |
| Measurement Interval | 1 hour |
| Data Output | RS-232C, optional LAN (TCP/IP), analog 0–1 V, pulse & contact I/O |
| Power Supply | AC 100 V ±10 V, 50/60 Hz, ~200 VA |
| Dimensions (W×D×H) | 430 × 483.5 × 266 mm |
| Weight | Monitor unit: ~19 kg |
| Sampling pump | ~5 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APDA-375A |
| Measurement Principle | Beta-ray Absorption |
| Safety Classification | Non-explosion-proof |
| Measurement Range | Standard: 0–1000 / 0–5000 µg/m³ |
| Resolution | ±1.0 µg/m³ (instantaneous) |
| Accuracy | ±2.0 µg/m³ (24-h average) or ±1% of reading (for concentrations >80 µg/m³) |
| Detection Limit | <1.0 µg/m³ (24-h average), <4.8 µg/m³ (1-h average) |
| Sampling Flow Rate | 16.7 L/min |
| Cut-point Options | VSCC (Vortex Separation Cyclone Classifier) for PM10 |
| Operating Temperature | −30 to +60 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 220 V, 50/60 Hz |
| Power Consumption | ~200 VA (up to ~320 VA with optional dehumidification & heater) |
| Dimensions (Analyzer Unit) | 430 W × 400 D × 266 H mm |
| Weight (Analyzer Unit) | ~19 kg |
| Weight (Pump Unit) | ~5 kg |
| Analog Output | 4–20 mA or 0–1 V |
| Digital Interfaces | Optional RS-232C, Ethernet (TCP/IP) |
| Environmental Compliance | Designed for continuous ambient air quality monitoring per ISO 12103-1, EN 12341, and US EPA EQOA-PM-01 reference method equivalency criteria |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APHA-370 |
| Instrument Type | Online Gas Analyzer |
| Target Analytes | Total Hydrocarbons (THC), Methane (CH₄), Non-Methane Hydrocarbons (NMHC) |
| Measurement Principle | Flame Ionization Detection (FID) with Selective Combustion Technology |
| Detection Limit | 0.050 ppmC (2σ, ≤5 ppmC range) or 0.5% F.S. (2σ, >5 ppmC range) |
| Repeatability | ±1.0% F.S. |
| Linearity | ±2.0% F.S. |
| Zero Drift | ±0.1 ppmC/day or ±2.0% F.S./day (whichever is greater) |
| Span Drift | ±2.0% F.S./day |
| Response Time (T90) | ≤60 s |
| Sample Flow Rate | ~0.9 L/min |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz (configurable) |
| Dimensions | 430 W × 550 D × 221 H mm |
| Weight | ~33 kg |
| Output Signals | 0–1 V / 0–10 V / 4–20 mA (user-selectable) |
| Data Storage | CF card (optional) |
| Communication | Ethernet/LAN interface (optional) |
| Display Language | English, German, French, Japanese |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APHA-370 |
| Measurement Principle | Flame Ionization Detection (FID) with Selective Combustion Technology |
| Target Analytes | CH₄, NMHC, THC (expressed as ppmC) |
| Standard Range | 0–5 / 10 / 20 / 50 ppmC |
| Optional Range | 0–100 ppmC (4 selectable spans, span ratio ≤10) |
| Detection Limit | 0.050 ppmC (2σ, for ranges ≤5 ppmC) or 0.5% F.S. (2σ, for ranges >5 ppmC) |
| Repeatability | ±1.0% F.S. |
| Linearity | ±2.0% F.S. |
| Zero Drift | ±0.1 ppmC/day or ±2.0% F.S./day (whichever is greater) |
| Span Drift | ±2.0% F.S./day |
| Response Time (T90) | ≤60 s |
| Sample Flow Rate | ~0.9 L/min |
| Output Signals | 0–1 V, 0–10 V, 4–20 mA (user-specified) |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz (configurable) |
| Dimensions | 430 W × 550 D × 221 H mm |
| Weight | ~33 kg |
| Display Language Options | English, German, French, Japanese |
| Data Storage | CF card (optional) |
| Network Interface | Ethernet/LAN (optional) |