Environmental Monitoring Instruments
Filter
Showing 3151–3180 of 9112 results
| Brand | Hitech |
|---|---|
| Origin | United Kingdom |
| Model | IR600 |
| Instrument Type | Online Gas Analyzer |
| Detection Target | Single-component (CO₂ or CH₄) |
| Measurement Range | 0–100% CO₂ (selectable down to 0–3000 ppm) |
| Repeatability | ±1% of full scale |
| Resolution | 0.01% |
| Response Time (T₉₀) | 6 s (sensor response) |
| Zero Drift | ±1% FS/12 months |
| Span Drift | ±1% FS/12 months |
| Linearity Error | ±2% FS |
| Output | 4–20 mA (max. 500 Ω load) |
| Operating Temperature | 0–40 °C |
| Enclosure Rating | IP54 |
| Power Supply | 110/220/240 V AC, 50/60 Hz |
| Power Consumption | 13 W typical |
| Weight | 2.7 kg |
| Brand | HJ (Hujing Purification) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Y09-010 |
| Power Supply | AC 220 V, 50 Hz |
| Internal Tank Capacity | 2500 mL (Optimal Fill: 1200 mL) |
| Dimensions (L×W×H) | 280 × 265 × 300 mm |
| Net Weight | 9 kg |
| 雾化部件输入电压 | DC 45 V |
| Rated Power Consumption | 210 W |
| Fog Generation Rate | ≥5500 mL/h |
| Aerosol Output Flow Rate | 0.95 m³/min |
| Droplet Size Distribution | 1–10 µm (≥80% mass concentration within range) |
| Optimal Water Level for雾化 | 28 mm |
| Visible Plume Height | 120–150 mm |
| Compatible Water Conductivity Range | 0.15–1.00 mS/cm |
| Continuous Operation Duration | ≥50 min |
| Noise Level | Low (≤52 dB(A) at 1 m) |
| 雾化管 Compatibility | Yes (up to 2 m extension for curtain-type aerosol delivery) |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HK-3070ZD |
| Quotation | Upon Request |
| Temperature Control Range | Ambient to 120 °C |
| Temperature Accuracy | ±0.2 °C (ambient–60 °C), ±0.3 °C (60–120 °C) |
| Oscillation Frequency | 275 ±5 cycles/min |
| Oscillation Amplitude | 35 mm |
| Timer Range | Adjustable (0–999 min) |
| Power Supply | AC 220 V ±10 %, 50 Hz |
| Operating Ambient Temperature | 5–40 °C |
| Operating Ambient Humidity | ≤85 % RH (non-condensing) |
| Dimensions (W×D×H) | 500 × 460 × 420 mm |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HK-51 |
| Price Range | USD 700–1,400 (FOB) |
| Instrument Type | Sodium Ion-Specific Analyzer |
| Form Factor | Benchtop |
| Measurement Range | (1.00–8.00) pNa, equivalent to 0.23 µg/L–2.30 g/L Na⁺ |
| Detection Limit | ±0.03 pNa or ±5 µg/L (whichever is greater) |
| Response Time (T₉₀) | 2 min at 25 °C |
| Temperature Compensation | Automatic or Manual (0.1–60.0 °C) |
| Temperature Measurement Range | (0.0–99.9) °C |
| Temperature Accuracy | ±0.5 °C |
| Display | 192×64 dot-matrix LCD (English/Chinese selectable) |
| Resolution | 0.01 pNa / 0.01 µg/L |
| Electronic Unit Error | ±0.01 pNa or ±1 digit |
| Stability | ±0.01 pNa / 4 h |
| Input Impedance | ≥1×10¹² Ω |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Power Consumption | 3 W |
| Dimensions | 270 × 200 × 65 mm (L×W×H) |
| Weight | 2 kg |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-7000 |
| Pricing | Available Upon Request |
| Control Channels | 2 / 4 / 6 / 8 channels |
| Operating Temperature | 0–70 °C |
| Relative Humidity | ≤93% RH (non-condensing) |
| Input Signal | 4–20 mA (calibratable within 2–30 mA) |
| Display Range | 0–9999 (numeric), or time format (YYYY-MM-DD HH:MM:SS) |
| Analog Bar Graph | 0–100% FS |
| Communication Interface | RS-485 digital output |
| Alarm Relay Output | SPST dry contact, rated AC 220 V / 3 A or DC 24 V / 3 A |
| Alarm Functionality | Dual-stage audible/visual alarm with time-stamped event lockout |
| Data Retention | Non-volatile memory for operational history (power-on/off, alarm, fault, reset, calibration) |
| Local Calibration | Supported for connected transmitters |
| Compliance | GB 16808–1997 |
| Measurement Accuracy | ±1% FS |
| Display Resolution | 1 digit |
| Alarm Setpoint Range | 0–9999 (user-configurable) |
| Display Mode | Dual-channel — numeric LED + analog bar graph |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-7000 |
| Pricing | Available Upon Request |
| Display | 320×240 dot-matrix LCD with Chinese interface, 8 channels per screen, configurable screen refresh interval (1–9 sec) |
| Measurement Range | Dependent on connected detector type |
| Accuracy | ±1% F.S. |
| Maximum Detector Capacity | 32 units |
| Alarm Levels | Dual-stage (Level 1 & Level 2), user-configurable thresholds |
| Alarm Output | 8 shared relays for 32-channel alarm and fault signaling (DC 24 V / 5 A or AC 220 V / 5 A) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | ≤93% RH at 40 °C (non-condensing) |
| Atmospheric Pressure | 86–106 kPa |
| Input Signal | CAN bus or 4–20 mA analog |
| Maximum Communication Distance | ≤10 km |
| Power Supply | AC 220 V ±15%, 50/60 Hz |
| Detector Power Output | DC 24 V (max. 5 A) |
| Backup Power | 2 × 12 V / 7 Ah sealed lead-acid batteries |
| Power Consumption | ≤150 W |
| Compliance Standard | Q/HDHKY023-2006 |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HK-7000 |
| Pricing | Available Upon Request |
| Input Signal | 4–20 mA (calibratable within 2–30 mA) |
| Display | 4-digit LED (0–9999), real-time clock (YYYY-MM-DD HH:MM:SS), bar-graph %FS indication |
| Output | RS-485 Modbus RTU digital interface |
| Relay Outputs | SPST dry contact, rated AC220V/3A or DC24V/3A |
| Operating Temperature | 0–70 °C |
| Relative Humidity | ≤93% RH (non-condensing) |
| Data Retention | Non-volatile memory with power-loss-proof event logging (“black box”) |
| Enclosure Options | Wall-mounted unit or modular rack-mount cabinet (10–60 channels) |
| Dimensions (Unit) | 80 × 210 × 60 mm (W × H × D) |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Pricing | Available Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Detection Principle | Catalytic Combustion |
| Model Variant | HK-7100A (Catalytic Bead Configuration) |
| Pricing | Available Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Digital Multi-Principle Gas Detector Platform (5 Sensing Technologies) |
| Pricing | Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HK-7200A |
| Price | Upon Request |
| Detection Principle | Metal Oxide Semiconductor (MOS) |
| Display | OLED, Bilingual (Chinese/English) |
| Operating Temperature | -40 °C to +70 °C |
| Atmospheric Pressure Range | 86–106 kPa |
| Measurement Range Options | 0–100 ppm, 0–200 ppm, 0–500 ppm, 0–1000 ppm, 0–2000 ppm |
| Resolution | 1 ppm |
| Accuracy | ±5% FS |
| Response Time (T90) | ≤30 s |
| Alarm Output | Dual-level visual (LED) and relay |
| Signal Outputs | 4–20 mA, CAN bus, RS485 |
| Transmission Distance | 4–20 mA ≤1000 m (2.5 mm² cable), CAN ≤10 km, RS485 ≤1.2 km |
| Power Supply | DC 18–30 V |
| Wiring | 3-wire or 4-wire configuration |
| Power Consumption | ≤2 W |
| Explosion Protection | Ex d IIC T6 Gb |
| Ingress Protection | IP66 |
| Compliance Standard | GB 12358–2006 |
| Sampling Method | Natural diffusion |
| Sensor Interface | Hot-swappable, plug-and-play MOS sensor module |
| Firmware Architecture | 32-bit embedded microcontroller |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HK-7200A Digital Multi-Principle Gas Detector |
| Pricing | Available Upon Request |
| Detection Principle | Photoionization (PID) |
| Measurement Range | 0–20 ppm, 0–100 ppm, 0–200 ppm, 0–500 ppm, 0–1000 ppm, 0–2000 ppm |
| Resolution | 1 ppm |
| Accuracy | ±3% FS |
| Response Time (T90) | ≤30 s |
| Operating Temperature | −40 to +55 °C |
| Atmospheric Pressure Range | 86–106 kPa |
| Output Signals | 4–20 mA, CAN Bus, RS485 |
| Max Transmission Distance | 1000 m (4–20 mA, 2.5 mm²), 10 km (CAN), 1.2 km (RS485) |
| Supply Voltage | DC 18–30 V |
| Wiring | 3-wire or 4-wire |
| Power Consumption | ≤2 W |
| Explosion Protection | Ex d IIC T6 Gb |
| Ingress Protection | IP66 |
| Compliance Standard | GB 12358–2006 |
| Display | High-brightness OLED, bilingual Chinese/English interface |
| Operation Modes | Magnetic stylus & bidirectional infrared remote |
| Sensor Interface | Hot-swappable, auto-diagnostic, multi-principle sensor platform (PID, electrochemical, catalytic bead, infrared, MOS) |
| Compatible Gases | VOCs and selected toxic gases (e.g., benzene, toluene, xylene, styrene, acetone, isopropanol, chlorinated hydrocarbons) |
| Brand | Huakeyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | HK-7501 |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Online Analyzer |
| Measurement Method | Nessler Reagent Spectrophotometry |
| Measurement Range | 0–10 mg/m³ (customizable) |
| Detection Limit | 0.05 mg/m³ |
| Zero Drift | ±1% FS/month |
| Cycle Time | 5 min |
| Heating Temperature | 180–240 °C |
| Sample Flow Rate | 4–5 L/min |
| Reagent Consumption | Nessler Reagent 1 L/month, Potassium Sodium Tartrate Solution 0.5 L/month |
| Ambient Temperature | −10 to 50 °C |
| Power Supply | AC 200–240 V |
| Power Consumption | ≤1 kW |
| Compressed Air | 0.6–0.8 MPa |
| Enclosure Dimensions | 850 × 600 × 1780 mm (L×W×H) |
| Analog Output | 1 channel (0–10 mA / 0–20 mA / 4–20 mA, isolated, max load 750 Ω) |
| Relay Outputs | 3 channels |
| Communication Interface | RS485 |
| Filtration Precision | 2 µm (metal-ceramic composite membrane) |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-8620 |
| Pricing | Available Upon Request |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-8630 |
| Pricing | Available Upon Request |
| Brand | Guangdong Huan Kai (BHK) |
|---|---|
| Model | HK-QR-1 |
| Sampling Principle | Virtual Impactor-Based Liquid Impingement |
| Total Flow Range | 0–9999 L |
| Total Flow Rate | 50–130 L/min, ±5% |
| Concentration Flow Rate | 5–15 L/min, ±5% |
| Flow Repeatability Error | ±2% |
| Sampling Time Range | 0–9999 s |
| Delay Time Range | 0–9999 s |
| Programmed Sampling Cycles | Up to 255 |
| Theoretical Concentration Ratio | 1:10 |
| Collection Liquid Volume | 20 mL |
| Inlet Load Capacity (with Separator) | ≥2 kPa |
| Concentration Circuit Load Capacity | ≥50 kPa |
| Operating Temperature | Ambient |
| Operating Humidity | Ambient |
| Data Storage Capacity | 4000 Records with Location ID, Group ID, Volume, Timestamp, etc. |
| Display | 3.5-inch HD Touchscreen (Bilingual UI) |
| Compliance | GB/T 18204.5–2013, WS 394–2012, GB/T 38517–2020, GB/T 18204.3–2013, JJF 1826–2020 |
| Brand | HKM (Guangdong Huankai Microbial Technology Co., Ltd.) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model No. | 090000 |
| Pricing | Available Upon Request |
| Brand | HKM |
|---|---|
| Origin | Guangdong, China |
| Model | 090080 |
| Detection Range | 0.01–1 mg/L (with discrete calibration points at 0.01, 0.05, 0.1, 0.2, 0.4, 0.6, 0.8, and 1.0 mg/L) |
| Packaging | Single-use sealed pouches per test |
| Compliance | Patented (CN ZL200510037389.8) |
| Intended Use | Field-deployable colorimetric determination of ammonia nitrogen in freshwater, aquaculture systems, wastewater effluents, and surface water |
| Brand | HKM |
|---|---|
| Model | CG100A |
| Sampling Principle | Anderson Impactor-Based Impaction |
| Flow Rate | 100 L/min (adjustable 10–100 L/min) |
| Pressure Range | 0–1 MPa |
| Sampling Volume Range | 10–6000 L |
| Sampling Duration | Up to 24 h per cycle |
| Data Storage Capacity | 8,000 records |
| Power Supply | DC 8.4 V / 6000 mAh Li-ion battery (24 h continuous operation) |
| Dimensions | 26.5 × 23.5 × 31.5 cm |
| Weight | 4.5 kg |
| Housing Material | Stainless steel main unit |
| Display | 122 × 32 LCD with bilingual (English/Chinese) interface |
| Input Voltage | 100–240 V AC, 50–60 Hz (via external adapter) |
| Brand | HKM |
|---|---|
| Model | DPC-2830 |
| Application | Laboratory-grade airborne particle counting |
| Flow Rate | 28.3 L/min |
| Flow Accuracy | ≤±5% |
| Timing Accuracy | ≤±1 s per 6-min sampling |
| Repeatability | ≤±10% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | ≤±30% FS |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Light Source | Semiconductor laser (≥30,000 h lifetime) |
| Self-Cleaning Time | ≤10 min |
| Communication Interfaces | RS-232 (9600 bps), Mini-USB, optional Ethernet |
| Data Storage | Internal high-capacity memory with UCL (95% confidence level) calculation |
| Power | Rechargeable Li-ion battery (optional external AC adapter) |
| Filter for Zero Count | Included |
| Optional Accessories | External printer, sampling tripod, temperature/humidity/pressure differential modules |
| Brand | HKM |
|---|---|
| Model | HK-QR-1 |
| Origin | Guangdong, China |
| Sampling Principle | Virtual Impactor-Based Concentration + Liquid Impingement |
| Total Flow Range | 50–130 L/min (±5%) |
| Concentration Flow Range | 5–15 L/min (±5%) |
| Flow Repeatability | ±2% |
| Capture Efficiency | ≥90% for particles ≥0.5 µm |
| Theoretical Concentration Ratio | 1:10 |
| Collection Liquid Volume | 20 mL |
| Data Storage Capacity | 4000 sampling records with timestamp, location ID, group ID, volume, and duration |
| Display | 3.5-inch capacitive touch LCD (bilingual UI) |
| Compliance | GB/T 18204.5–2013, WS 394–2012, GB/T 38517–2020, GB/T 18204.3–2013, JJF 1826–2020 |
| Brand | HKM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model No. | 090010 |
| Detection Principle | DPD (N,N-Diethyl-p-phenylenediamine) Colorimetric Method |
| Measurement Range | 0.05–1.0 mg/L O₃ (8-point calibrated scale: 0.05 / 0.1 / 0.2 / 0.3 / 0.4 / 0.5 / 0.7 / 1.0 mg/L) |
| Format | Single-use tablet, individually foil-wrapped |
| Shelf Life | 24 months from manufacture date |
| Compliance | GB/T 5750.11–2023 (Standard Methods for Examination of Drinking Water – Disinfectants), ISO 6205:2021 (Water quality — Determination of ozone — DPD spectrophotometric method) |
| Brand | HKM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | 090490 |
| Price | USD 42 (approx.) |
| Detection Principle | Phosphomolybdenum Blue Colorimetric Method (for test strips) |
| Sample Matrix | Wastewater, Surface Water, Treated Effluent |
| Detection Range (Test Strips) | 0–3–10–25–50–100–200–400 mg/L PO₄³⁻ as P |
| Total Phosphorus Compatibility | Yes (requires acid persulfate or UV digestion prior to testing) |
| Calibration | Pre-calibrated visual color chart included |
| Shelf Life | 24 months from manufacture date when stored at 2–30 °C, protected from moisture and light |
| Compliance | Designed in alignment with ISO 6878:2004 (Water quality — Determination of phosphorus — Ammonium molybdate spectrophotometric method) and EPA Method 365.1 (Phosphorus, total, automated, persulfate digestion) |
| Brand | HKM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 0–10 mg/L |
| Instrument Type | Laboratory-Grade Test Strips |
| Measurement Principle | DPD (N,N-Diethyl-p-phenylenediamine) Colorimetric Method |
| Measured Parameter | Free Residual Chlorine |
| Measurement Range | 0–10 mg/L |
| Accuracy | ±1 mg/L |
| Repeatability | ±1 mg/L |
| Resolution | 1 mg/L |
| Limit of Detection | 0.3 mg/L (visual colorimetric endpoint) |
| Brand | HKM |
|---|---|
| Model | S-101 |
| Measurement Range | 0.00–2.50 mg/L |
| Wavelength | 510 nm |
| Light Source | Silicon Photodiode |
| Accuracy | ±0.05 mg/L (0.05–0.99 mg/L), ±0.10 mg/L (1.00–2.50 mg/L) |
| Method | DPD Colorimetric Method per GB 11898–1989 |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 0–90 % RH (non-condensing) |
| Power Supply | 1 × 9 V alkaline battery (≥40 h continuous operation) |
| Dimensions | 170 × 70 × 30 mm |
| Weight | 200 g (including battery) |
| Compliance | Designed to support compliance with ISO 7027, APHA Standard Methods 4500-O₃, and Chinese National Standard GB 11898–1989 |
| Brand | HKM |
|---|---|
| Model | S-102 |
| Measurement Range | 0.00–3.00 mg/L (as Cl₂) |
| Wavelength | 510 nm |
| Light Source | Silicon Photodiode |
| Accuracy | ±0.05 mg/L (for readings < 1.00 mg/L) |
| Method | DPD (N,N-Diethyl-p-phenylenediamine) Colorimetric Reaction |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 0–90% RH (non-condensing) |
| Power Supply | 1 × 9 V alkaline battery (≥40 h continuous operation) |
| Dimensions | 170 × 70 × 30 mm |
| Weight | 200 g (including battery) |
| Standard Kit Includes | 1 instrument unit, 2 matched cuvettes, 200 total test cycles (100 free chlorine + 100 total chlorine), reagent packs available separately (100 tests/pack) |
| Brand | HKM |
|---|---|
| Origin | Guangdong, China |
| Model | S-107 |
| Measurement Range | 5–999 mg/L |
| Wavelength | 450 nm |
| Light Source | Blue LED |
| Accuracy | ±5% |
| Display | LCD (mg/L) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 0–90% RH (non-condensing) |
| Power | 1 × 9 V battery (≥40 h lifetime) |
| Dimensions | 170 × 70 × 30 mm |
| Weight | 200 g (with battery) |
| Includes | Instrument host, 2 matched cuvettes |
| Compliance | Aligned with GB 26366–2010 and methodology per 2002 Disinfection Technical Guidelines (Spectrophotometric Method) |
| Brand | HKM |
|---|---|
| Origin | Guangdong, China |
| Model | S-202 |
| Instrument Type | Portable |
| Measurement Principle | DPD Spectrophotometry |
| Measured Parameter | Free Residual Chlorine |
| Range | 0–10 mg/L |
| Accuracy | ±5% |
| Repeatability | ±5% |
| Resolution | 1 mg/L |
| Detection Limit | 1 mg/L |
| Power | Alkaline batteries (≥40 h operation per set) |
| Brand | HKM |
|---|---|
| Origin | Guangdong, China |
| Model | S-206 |
| Instrument Type | Portable |
| Measurement Parameter | Chlorine Dioxide (ClO₂) |
| Measurement Range | 5–999 mg/L |
| Accuracy | ±5% |
| Repeatability | ±3 mg/L |
| Resolution | 1 mg/L |
| Detection Limit | 1 mg/L |
| Light Source | LED |
| Wavelength | 445 nm |
| Power Supply | 4 × 1.5 V AA batteries |
| Dimensions | 159 × 68 × 35 mm |
| Weight | 220 g (including batteries) |
| Compliance | Compatible with Standard Iodometric Methods (Five-Step and Malonic Acid Iodometric Methods) |
| Brand | HKM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SMT Series |
| Instrument Type | Soil Moisture and Temperature Analyzer |
| Measurement Principle | Frequency Domain Reflectometry (FDR) |
| Soil Moisture Range | 0–60% (±2% accuracy, 0.1% resolution) |
| Soil Temperature Range | −10 to +85 °C (±0.3 °C accuracy, 0.1 °C resolution) |
| Sensor Active Zone | Cylindrical volume 4 cm diameter × 7 cm length centered on probe |
| Probe Material | Stainless steel |
| Sensor Housing | ABS |
| Cable Length | 2 m |
| Data Storage Capacity | 16,000 records |
| Sampling Interval | 1 minute to 24 hours (user-configurable) |
| Display | 2.6-inch backlit LED screen |
| Power Supply | Four 10440 Li-ion batteries (3.6 V total), >12 h continuous operation |
| Communication Interface | USB 2.0 (SM-100A model only) |
| Software Features | Data export to Excel, time-series curve visualization, multi-site comparative analysis, configurable upper/lower limits, GLP-compliant audit trail generation, bilingual (EN/CN) UI, lifetime free updates |