| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | PRO 1590-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Display | 7-inch color LCD touchscreen |
| Data Storage | 8 GB internal memory (24,500 measurements per unit) |
| Communication | USB 2.0, LAN (RJ45), serial interface |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (main unit) | 220 × 130 × 40 mm |
| Weight | 0.6 kg |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Instrument Type | Online Particle Counter |
| Flow Rate | 28.3 L/min (1 CFM) |
| Particle Size Channels | 0.3 & 0.5 μm (3718-A) / 0.5 & 5.0 μm (3719-A) |
| Light Source | Long-life Laser Diode |
| Compliance | ISO 21501-4, JIS B 9921, ISO 14644-1:2015 |
| Data Storage | 2,000 Sample Records with Redundant Backup |
| Output Interfaces | RS485, Modbus RTU/TCP/IP, 4–20 mA Analog Output |
| Power Supply | DC 9–28 V, PoE, or AC 100–240 V |
| Enclosure Material | 316 Stainless Steel with VHP/Alcohol-Vapor Resistant Sealing |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Dimensions | 133 × 95 × 80 mm |
| Weight | 1.0 kg |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 3720-06 |
| Pricing | Available Upon Request |
| Particle Size Channels | Selectable 2–4 channels from 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm (standard configuration: 0.5 & 5.0 µm) |
| Flow Rate | 28.3 L/min (1.0 CFM) |
| Light Source | Long-life laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B 9921 |
| Max. Detectable Concentration | 1,000,000 particles/ft³ |
| Data Storage | 5,000 measurement records (2,000 in volatile buffer with redundancy) |
| Housing Material | 316 stainless steel with VHP- and ethanol vapor-resistant sealed enclosure |
| Vacuum Sampling Pump | Removable and serviceable |
| Power Supply | DC 15–28 V, PoE (IEEE 802.3af), or AC 100–240 V |
| Communication Interfaces | Ethernet (Modbus TCP/IP), RS-485 (Modbus RTU), 4–20 mA analog output |
| Alarm Output | Configurable 0–100% threshold, relay ON/OFF |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Storage Conditions | −10–50 °C, ≤95% RH (non-condensing) |
| Dimensions | 180 × 110 × 190 mm |
| Weight | 4.0 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | 3720-06 |
| Instrument Type | Online Particle Counter |
| Flow Rate | 28.3 L/min (1.0 CFM) |
| Detectable Particle Sizes | 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm (user-selectable 2–4 channels, factory-configured) |
| Light Source | Long-life laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Max. Concentration | 1,000,000 particles/ft³ |
| Data Storage | 5,000 records (2,000-record buffer + redundancy backup) |
| Enclosure Material | 316 stainless steel with VHP- and ethanol vapor-resistant sealing |
| Vacuum Sampling Pump | Removable and serviceable |
| Power Supply | DC 15–28 V, PoE (IEEE 802.3af), or AC 100–240 V |
| Communication | Ethernet (Modbus TCP/IP), RS-485 (Modbus RTU), 4–20 mA analog output |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Dimensions | 180 × 110 × 190 mm |
| Weight | 4.0 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | SDM-II |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Sampling Flow Rate | 1.7 L/min |
| Detection Principle | Laser Scattering (90° Forward Light Scattering) |
| Safety Rating | Non-Explosive |
| Communication Interface | RS485 |
| Zero & Span Auto-Calibration | Yes |
| Alarm Threshold Setting | Yes |
| Built-in Dehumidification | Yes |
| Filter Membrane Sampling Module | Included |
| Compliance | ISO 12103-1 A2 Fine Test Dust Compatible, Meets JIS B 7960 for Optical Dust Monitors |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | SDM-II |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | PM2.5, PM10, TSP |
| Measurement Range | 0.001–30.000 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Sampling Flow Rate | 1.7 L/min |
| Zero & Span Auto-Calibration | Yes |
| Alarm Threshold Setting | Yes |
| Automatic Dehumidification | Yes |
| Communication Interface | RS485 |
| Power Supply | DC 10–15 V, 2 A |
| Dimensions (w/o case) | 250 × 350 × 170 mm |
| Weight (w/o case) | ~4.5 kg |
| Weight (with case) | ~8 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | SDM-II+ |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | PM2.5, PM10, TSP |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Sampling Flow Rate | 1.7 L/min |
| Zero & Span Auto-Calibration | Yes |
| Humidity Compensation | Integrated Automatic Dehumidification |
| Alarm Threshold Setting | Configurable Concentration Limit |
| Communication Interface | RS485 |
| Power Supply | DC 10–15 V, 2 A |
| Dimensions (W×H×D) | 250 × 350 × 170 mm (unit only) |
| Weight | ~4.5 kg (unit only) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Dependent on Interchangeable Probe (e.g., 0–30 m/s for standard hot-wire probe) |
| Accuracy | ±2% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | Up to 20,000 records |
| Probe Compatibility | 8 interchangeable probe types (hot-wire, vane, pitot tube, and specialized duct probes) |
| Built-in Calculations | Volumetric flow (m³/h, CFM) via user-defined duct geometry (rectangular, circular, oval cross-sections with dimensional input) |
| Statistical Functions | Real-time min/max/average, hold function |
| Accessories Included | 2 m probe cable, carrying case, operator manual |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature Range | −20 °C to +70 °C |
| Operating Relative Humidity Range | 2.0–98.0% RH |
| Probe Compatibility | 8 interchangeable thermal anemometry probes (hot-wire/hot-film) |
| Data Storage Capacity | Up to 20,000 measurement records |
| Built-in Calculations | Real-time air volume (m³/h or CFM) via user-defined duct geometry (rectangular, circular, oval cross-sections with dimensional input) |
| On-device Statistics | Min/Max/Avg values with hold function |
| Standard Accessories | 2 m probe cable × 1, carrying case × 1, operator manual |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Kanomax SXYC-508 |
| Operating Principle | Optical Scattering (β-ray attenuation & integrated gravimetric verification) |
| Safety Rating | Non-explosion-proof |
| Dust Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Noise Range | 30–130 dB(A) |
| Noise Accuracy | ±0.5 dB |
| Atmospheric Pressure Range | 10–1100 hPa |
| Pressure Accuracy | ±0.3 hPa |
| Wind Speed Range | 0.00–70.0 m/s |
| Wind Speed Accuracy | ±0.03 m/s |
| Wind Direction Range | 0–360° |
| Direction Accuracy | ±0.5° |
| Temperature Range | −50–100°C |
| Humidity Range | 0–100% RH |
| Temp/Humidity Accuracy | ±0.5°C / ±3% RH |
| Power Consumption | 30 W |
| Power Supply | AC 220 V ±10% with backup battery (≥6 h runtime) |
| Data Protocol Compliance | HJ/T 212–2005 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | SXYC-508 |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Safety Classification | Non-explosion-proof |
| Compliance Standard | HJ/T 212–2005 |
| Detection Principle | Beta-ray attenuation (integrated gravimetric reference via filter sampling) |
| Brand | Kasahara |
|---|---|
| Origin | Japan |
| Model | CU-502 |
| Instrument Type | Online Multi-Ion Analyzer |
| Measurement Principle | Absorption Photometry (LED-based, AC-driven dual-beam) |
| Measuring Range (Cu) | 0–20 g/L, 0–50 g/L, 0–80 g/L (selectable) |
| Measuring Range (CuSO₄) | 0–100 g/L, 0–200 g/L, 0–300 g/L (selectable) |
| Detection Limit | 1 g/L (Cu) |
| Resolution | 0.1 g/L (Cu), 1 g/L (CuSO₄) |
| Accuracy | ±2% FS |
| Repeatability | ±2% |
| Response Time | ≤5 s |
| Operating Temperature | –5 °C to +40 °C |
| Humidity Limit | ≤85% RH (non-condensing) |
| Power Supply | AC 85–240 V, 50/60 Hz |
| Output Signal | DC 4–20 mA (isolated, 2-wire) |
| Dimensions (H×W×D) | 96 × 96 × 163 mm |
| Weight | ~1.3 kg |
| Compliance | CE-marked for industrial environments |
| Enclosure Rating | IP65 front panel |
| Brand | Kasahara |
|---|---|
| Origin | Japan |
| Model | RC-V2 |
| Instrument Type | Portable |
| Measurement Principle | DPD Spectrophotometry |
| Measured Parameters | Chlorine Dioxide (ClO₂) and Total/Free Available Chlorine |
| Measurement Range | 0–200 g/L (multi-range, auto-ranging) |
| Accuracy | ±5% of reading |
| Repeatability | ≤2% RSD |
| Detection Limit | 0.01 mg/L (at lowest range) |
| Wavelengths | Triple-wavelength optical system (515 nm, 550 nm, 610 nm) |
| Compliance | Designed for HACCP-aligned disinfection process control |
| Power Supply | Rechargeable Li-ion battery (≥8 hrs continuous operation) |
| Brand | Kasuri |
|---|---|
| Origin | Japan |
| Model | H2O2-V2L |
| Measurement Range | 0–1200 mg/L |
| Resolution | 1 mg/L |
| Accuracy | ±5% FS |
| Repeatability | ±5% FS |
| Response Time | <5 s after power-on |
| Auto-off | After 5 s hold of measurement button |
| Dimensions | 88 × 174 × 65 mm |
| Weight | ~310 g |
| Power | 4× AAA alkaline batteries (DC 6 V) |
| Measurement Method | LED-based photometry with dual-wavelength compensation |
| Calibration | Zero-point calibration standard |
| Sample Compatibility | Aqueous copper plating electrolytes containing Cu²⁺, Fe²⁺/Fe³⁺, Ni²⁺, Cr⁶⁺/Cr³⁺ |
| Compliance | Designed per JIS K 0121 and ISO 15705 for photometric water analysis in industrial process control |
| Brand | Kasuri |
|---|---|
| Origin | Japan |
| Model | KF-502 |
| Instrument Type | Online Fluoride Ion Analyzer |
| Measurement Range | 0–1000 mg/L |
| Detection Limit | 0.1 mg/L |
| Response Time | 1 s |
| Accuracy | ±0.1 mg/L (within range) |
| Resolution | 0.1 mg/L (0–199.9 mg/L), 1 mg/L (200–1000 mg/L) |
| Repeatability | ±2% FS |
| Output Signal | Isolated DC 4–20 mA (≤500 Ω load) |
| Calibration | Zero & Span |
| Power Supply | AC 85–240 V, 50/60 Hz |
| Operating Environment | 0–40 °C, ≤85% RH |
| Dimensions | 96 W × 96 H × 163 D mm |
| Weight | ~1.3 kg |
| pH Range for Accurate Measurement | 4.0–9.0 |
| Electrode Principle | Solid-State Ion-Selective Membrane (ISM) |
| Brand | Kasuri |
|---|---|
| Model | KP-11Z |
| Measurement Principle | Glass Electrode (pH), Platinum Electrode (ORP), Thermistor (Temperature) |
| pH Range | 0.00–14.00 (0.01 resolution) |
| ORP Range | −1999 to +1999 mV (1 mV resolution) |
| mV Range | −1999 to +1999 mV (1 mV resolution) |
| Temperature Range | 0.0–50.0 °C (0.1 °C resolution) |
| Accuracy (pH) | ±0.02 pH |
| Accuracy (ORP/mV) | ±0.2% of reading |
| Accuracy (Temp) | ±0.2 °C |
| Repeatability | pH ≤ ±0.02, ORP/mV ≤ ±0.2%, Temp ≤ ±0.2 °C |
| ATC | Yes (0–45 °C) |
| Memory Capacity | 30 data sets |
| Power | 4.5 V DC (3 × AAA/LR03 batteries) |
| Auto-off | 30 min |
| IP Rating | IP67 (with properly mated probe connector) |
| Dimensions (main unit) | 70 × 40 × 173 mm (W×H×D) |
| Weight (unit only) | ~290 g |
| Housing Material | ABS plastic |
| Electrode | PHD-11 (glass pH/platinum ORP, 3 m cable) |
| Compliance | JIS T 1201 (pH meters), JIS K 0101 (water analysis), SS242 & S251 certified electrode types |
| Brand | Meiko Rikka |
|---|---|
| Origin | Japan |
| Model | 602SP |
| Detection Principle | Colorimetric Reaction via Impregnated Reagent Layer |
| Target Analyte | Oil Mist (Hydrocarbon Aerosol) |
| Measurement Range | 0.3–5 mg/m³ |
| Response Time | 25 min |
| Operating Temperature | 0–40 °C |
| Storage Condition | 0–25 °C, dark and dry |
| Required Accessories | Kawakami P-40R Compressed Air Sampling Kit with Regulator & Flow Control |
| Compliance Reference | DIN 3188, CSA Z180.1, BS EN 12021, ISO 8573-1 Class 2 (for oil aerosol), CGA G-4.1 |
| Brand | Kohei Rikka |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 603SP |
| Pricing | Upon Request |
| Brand | KC Starlight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | XG310 |
| Price | USD 2,450 (FOB) |
| Measured Parameter | Total Phosphorus |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Spectrophotometry (Ammonium Molybdate Method) |
| Measurement Range | 0–20 mg/L |
| Accuracy | ≤ ±2% |
| Detection Limit | 0.02 mg/L |
| Resolution | 0.001 mg/L |
| Brand | KC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | XG03 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method |
| Measurement Range | 0.0–100.0 µg/L |
| Accuracy | ±2% F.S. |
| Detection Limit | 0.01 µg/L |
| Measurement Time | <4 min |
| Batch Capacity | 6 channels |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | GC2002 |
| Detection Targets | Trace Impurity Analysis in High-Purity Gases (He, H₂, N₂, CO₂, etc.) |
| Temperature Control Precision | ±0.01 °C |
| EPC/EFC Pressure Accuracy | 0.001 psi |
| EPC/EFC Flow Accuracy | 0.001 mL/min |
| Column Oven Cooling Time | ≤5 min (350 °C → 50 °C) |
| Max Programmed Temperature Ramps | 16 stages (extendable to unlimited) |
| Detector Options | TCD, FID, ECD, FPD |
| Data Interface | RJ45 Ethernet (TCP/IP), Embedded Chromatography Workstation |
| Remote Control Capacity | Up to 253 units per workstation |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region Category | Domestic (China) |
| Model | GC9800 (N₂/CO₂/THC Configuration) |
| Detection Targets | Trace Impurities in High-Purity Gases (He, H₂, N₂, CO₂, CH₄, CO, O₂, Total Hydrocarbons) |
| Detectors | TCD (TC-1H) + FID + Ni Catalyst Methanizer |
| Temperature Range | 8 °C above ambient to 400 °C |
| Temperature Control Accuracy | ±0.5% |
| Max. Programmed Ramps | 8 steps |
| Ramp Rate | 0–39 °C/min (0.1 °C/min increment) |
| TCD LOD | H₂ ≤ 0.5 ppm, O₂ ≤ 1 ppm, N₂ ≤ 3 ppm |
| FID LOD | CO 0.1–0.2 ppm, THC ≤ 2 ppm (Ar carrier) |
| Linear Range | FID 10⁷, TCD 10⁵ |
| Baseline Noise | FID ≤ 1×10⁻¹³ A, TCD ≤ 10 µV |
| Baseline Drift | FID ≤ 5×10⁻¹³ A/30 min, TCD ≤ 60 µV/30 min |
| Stabilization Time | FID ≤ 1 h, TCD ≤ 2 h |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | GC9800 High-Purity Gas Analyzer |
| Detection Targets | Trace impurity analysis in high-purity gases (He, H₂, N₂, CO₂, CH₄, O₂, CO, NH₃, Ar, etc.) |
| Detector | TC-1H Thermal Conductivity Detector (TCD) |
| TCD Sensitivity | ≥5000–10000 mV·mL/mg (benzene) |
| Baseline Noise | ≤0.01 mV |
| Baseline Drift | ≤0.1 mV/30 min |
| Linear Range | 10⁵ |
| Oven Temperature Range | 8°C above ambient to 400°C |
| Temperature Control Accuracy | ±0.5% |
| Programmable Temperature Ramping | 8-step |
| Ramp Rate | 0–39°C/min (0.1°C/min increment) |
| Ramp Reproducibility | ≤1% |
| Communication Interface | 10/100M Ethernet |
| Remote Control Capacity | Up to 253 units per workstation |
| Column Oven | Large-volume oven with automatic rear-door opening |
| Near-Ambient Operation | Enabled down to ambient +8°C |
| Self-Diagnostic System | Real-time fault localization and type identification |
| Over-Temperature Protection | Independent thermal cutoff for all six temperature zones |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GC9800 (N/SF₆/FPD) |
| Detection Targets | HCl, SiH₄, CF₄, SO₂F₂, S₂OF₂, S₂OF₁₀ (ppm-level trace impurities in ultra-high-purity SF₆) |
| FPD Sensitivity | ≤5.0×10⁻¹¹ g/s (n-hexadecane) |
| Baseline Noise | ≤0.1 mV |
| Baseline Drift | ≤0.5 mV / 0.5 h |
| Oven Temp Range | 8 °C above ambient to 400 °C |
| Temperature Control Accuracy | ±0.5% |
| Programmable Temperature Steps | 8 |
| Ramp Rate | 0–39 °C/min (0.1 °C/min increment) |
| Retention Time Reproducibility | ≤1% RSD |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GC9800N/TFH |
| Detection Targets | Trace impurities in high-purity helium (Ne, O₂, N₂, H₂, CO₂, CH₄), hydrogen, nitrogen, and carbon dioxide |
| Detectors | TCD (TC-1H) + FID + Ni methanizer |
| Minimum Detectable Concentration | Ne: 0.18 ppb v/v, O₂: 0.09 ppb v/v, N₂: 0.08 ppb v/v |
| Temperature Range | 8 °C above ambient to 400 °C |
| Temperature Control Accuracy | ±0.5% |
| Programmable Temperature Ramping | 8-step, 0–39 °C/min (0.1 °C/min increment) |
| Baseline Noise | ≤0.01 mV |
| Baseline Drift | ≤0.1 mV/30 min |
| Linear Range | 10⁵ |
| Column Oven | Motorized auto-back-opening, near-ambient operation (≥8 °C above ambient) |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HL-800 |
| Instrument Type | Laboratory Benchtop GC System |
| Detection Principle | Gas Chromatography–Flame Photometric Detection (GC-FPD) for Sulfur-Selective Quantification |
| Target Analytes | H₂S, Methanethiol (CH₃SH), Dimethyl Sulfide (DMS), Dimethyl Disulfide (DMDS) |
| Detection Range | 0.1–10 ppm (as sulfur) |
| Column Oven Temperature Program | 100 °C (1 min), then ramp at 5 °C/min to 240 °C |
| Typical Retention Times (H₂S, CH₃SH, DMS, DMDS) | 1.12–1.13 min, 2.72–2.73 min, 6.08–6.10 min, 16.58–16.60 min |
| Detector | Dual-Channel FPD with S-Mode optimization |
| Data Output | Peak Area, Peak Height, Retention Time, Calculated Concentration (ppm) |
| Compliance Framework | Designed for ASTM D5504, ISO 8573-5, and EPA Method 16, supporting GLP-compliant data integrity workflows |
| Brand | Kechuang Starlight (KC) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method |
| Measurement Range | 0.0–100.0 µg/L |
| Accuracy | ±2% F.S. |
| Detection Limit | 0.01 µg/L |
| Measurement Time | <4 minutes per cycle |
| Channel Capacity | 1–6 configurable channels |
| Display | 7.0-inch Windows-based HMI touchscreen |
| Sample Flow Rate | 10–40 L/h |
| Sample Temperature Range | 5–50 °C |
| Ambient Operating Temperature | 5–45 °C |
| Ambient Humidity | ≤85% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤100 W |
| Dimensions (L×D×H) | 460 × 285 × 720 mm |
| Weight | 23 kg |
| Output Signals | 4–20 mA, 0–20 mA, or 0–10 mA (configurable) |
| Data Storage | Non-volatile memory with >10-year retention after power loss |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HF-48 |
| Pricing | Upon Request |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HG-37N |
| Price Range | USD 68,000 – 136,000 (FOB Japan) |
| Measurement Principle | Cold Vapor Atomic Absorption Spectroscopy (CVAAS) with Dry Oxidation-Reduction Conversion |
| Measurement Range | 0–50 µg/m³N or 0–1000 µg/m³N (switchable) |
| Response Time | ≤90 s |
| Repeatability | ±1% of reading |
| Linearity Error | ±2% of full scale |
| Zero Drift | ≤±1% per week |
| Sample Gas Flow Rate | 300 mL/min |
| Calibration Interval | Recommended every 30 days |
| Interference Resistance | Immune to Cl⁻, SO₂, NOₓ, H₂O vapor, and particulate carryover under ISO 15202-compliant sampling conditions |
| Compliance | Designed to meet EPA Method 29, ASTM D6784-22, and EN 14181 QAL1 requirements for mercury CEMS |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HL-36NS |
| Pricing | Upon Request |