Environmental Monitoring Instruments
Filter
Showing 7861–7890 of 9029 results
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TH-ZX200 |
| Price Range | USD 14,000–21,000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Ion-Selective Electrode (ISE) Method |
| Measurement Range | 0–50 mg/L and 0–300 mg/L (dual-range auto-switching) |
| Accuracy | ±10% of reading |
| Detection Limit | 0.05 mg/L |
| Cycle Time | 10 minutes per measurement |
| Sample Throughput | 10 samples per batch |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-ZX300 |
| Measurement Parameter | Total Phosphorus |
| Instrument Type | Online Analyzer |
| Measurement Range | 0–10 mg/L and 0–50 mg/L (dual-range) |
| Accuracy | ±3% of reading |
| Detection Limit | 0.005 mg/L |
| Resolution | 3% (relative) |
| Fluidic Components | Imported solenoid valves (USA/Japan/Germany) |
| Reagent Consumption | Low-volume precision metering via optical sensing |
| Data Storage | ≥10,000 records with USB export capability |
| Compliance | Designed for continuous unattended operation in municipal WWTPs and surface water monitoring stations |
| Software | Embedded Linux-based control system with auto-calibration, dual-mode operation (online/auto vs. offline/manual), and audit-ready data logging |
| Brand | Tianhong |
|---|---|
| Model | THM-700 |
| Measurement Principle | Precision Splitting Technology + Thermal Mass Flow Sensing (for Air) |
| Flow Ranges | THM-701: 0–200 mL/min |
| THM-702 | 0–3 L/min |
| THM-703 | 0–20 L/min |
| Interface Diameter | Φ32.7 mm (1.25 in) |
| Operating Modes | Standard Condition (0 °C, 101.325 kPa) or Actual Condition (20 °C / 25 °C selectable) |
| Temperature & Pressure Compensation | Built-in |
| Power | Rechargeable Li-ion battery (12 h continuous operation) |
| Data Logging | 4 parameters recorded every 5 minutes |
| Wireless Communication | Integrated RF module for remote configuration and data retrieval |
| Compliance | Designed per Q/WTH 08–2014 (Tianhong Enterprise Standard), compatible with U.S. EPA reference method interface specifications |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Genrich 24 |
| Pricing | Upon Request |
| Brand | Tianyan |
|---|---|
| Model | TY-T80X |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Display | 3.5" TFT color LCD (800×480 resolution) |
| Power Supply | DC 8.4 V rechargeable lithium battery (10 h continuous operation) |
| Dimensions | 260 × 260 × 130 mm |
| Weight | 3.25 kg (main unit) |
| CO₂ Measurement | Dual-wavelength NDIR sensor, 0–5000 ppm range, 0.1 ppm resolution, ±3 ppm accuracy, temperature-compensated |
| Temperature Sensor | German Heraeus digital probe, –20 to +80 °C, 0.1 °C resolution, ±0.2 °C error |
| Relative Humidity Sensor | Swiss进口 digital sensor, 0–85 %RH, 0.1 %RH resolution, ≤1 %RH error |
| PAR Sensor | Calibrated silicon photodiode with optical filter (400–700 nm), 0–3000 µmol·m⁻²·s⁻¹, <1 µmol·m⁻²·s⁻¹ accuracy |
| Flow Control | Glass rotameter (0–1.5 L/min, ±1 % full scale |
| Chamber | Standard cylindrical chamber (Ø110 mm × 200 mm height) |
| Operating Environment | –20 to +60 °C, 0–85 %RH (non-condensing) |
| Data Storage | Internal 16 GB flash memory (expandable to 32 GB) |
| Data Interface | USB 2.0 for direct PC export |
| Optional Add-ons | Soil moisture & temperature probes |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TY-TN1_ |
| Instrument Type | Portable |
| Detection Channels | 8 |
| Measured Parameters | Soil Total Organic Carbon (TOC) and Carbon-to-Nitrogen Ratio (C/N) |
| Measurement Range | 0.001–9999 (unitless absorbance-derived index |
| Repeatability | ≤0.02% (based on potassium dichromate solution, CV) |
| Brand | Tianyan (Shandong Tianyan Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Manufacture | China |
| Model | TY-ZSD |
| Detection Principles | Colorimetric Spectrophotometry (Visible Range, 400–700 nm) |
| Measurement Method | Digestion + Reagent-Based Chromogenic Reaction + Absorbance Quantification per Lambert-Beer Law |
| Supported Elements | Pb, As, Cr(VI), Cd, Hg, Ni, Al, F, Ti, Se, Fe, Zn, Mn, Cu |
| Optical Accuracy | ±0.5% Transmittance |
| Repeatability | ≤±0.05% |
| Drift Stability | <0.001 AU/30 min (after 5-min warm-up) |
| Linearity Error | ≤0.2% (verified with CuSO₄ standard) |
| Power Consumption | ≤5 W |
| Input Power | AC 220 V / 50 Hz or DC 12 V |
| Output | Built-in thermal printer (auto-printing of results) |
| Sample Throughput | ~8–12 samples/hour (including digestion prep) |
| Compliance Standards | GB/T 5009.11–2003, GB/T 5009.12–2003, GB/T 5009.15–2003, GB/T 5009.17–2003, GB/T 5009.123–2003 |
| Brand | Tianze Environment |
|---|---|
| Origin | Shandong, China |
| Model | TZ-TY |
| Measurement Parameters | Soil EC (mS/cm), Salinity (g/kg or dS/m), Temperature (°C), Volumetric Water Content (%), pH, N/P/K (via optional ion-selective sensors) |
| Display | 3.5" color LCD (320×480) |
| Data Storage | 8 GB internal flash (≥280 million records per parameter) |
| Sampling Interval | 1–60 min configurable |
| Power | 3800 mAh Li-ion battery (Type-C rechargeable) |
| Enclosure Rating | IP65 (host), IP68 (probes) |
| Communication | RS-485 (Modbus RTU), USB virtual disk export, 4G LTE (optional DTU module) |
| Dimensions | 167 × 80 × 30 mm |
| Weight | 263 g |
| Operating Temp | 0–40 °C |
| RH Limit | ≤85% non-condensing |
| Sensor Interface | Dual RS-485 ports, auto-sensing probe recognition |
| Cloud Integration | Tianze Smart AgriCloud Platform (HTTPS/REST API compliant) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower Co., Ltd. |
| Type | Online Analyzer |
| Model | TP-106 |
| Measurement Principle | Molybdenum Blue Photometric Method |
| Display | 7.0-inch Color TFT Touchscreen (Chinese UI) |
| Range Options | 0.0–200.0 µg/L or 0.0–2000 µg/L |
| Accuracy | ±2% F.S. |
| Repeatability | ±1% F.S. |
| Cycle Time | ~12 min per channel |
| Channels | 1–6 configurable |
| Sample Flow Rate | 10–40 L/h |
| Sample Temp. | 5–45 °C |
| Max. Suspended Solids | <5 µm, non-colloidal |
| Ambient Temp. | 5–45 °C |
| Humidity | ≤90% RH (non-condensing) |
| Reagent Consumption | ~2 L/month per reagent (4 reagents total) |
| Digital Output | RS232 / RS485 |
| Analog Output | Isolated 0–20 mA / 4–20 mA / 0–10 mA selectable |
| Alarm Outputs | Independent per channel (sample loss, high/low limit) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤100 W |
| Dimensions | 460 × 281 × 720 mm (W×D×H) |
| Panel Cutout | 670 × 410 mm |
| Weight | ~20 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP-107 |
| Instrument Type | Online Analyzer |
| Compliance | GB/T 6913–2008 |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TP-1111 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Electrochemical Method (Online Configuration) |
| Wavelength | 610 nm |
| Measurement Range | 0–1500 mg/L or 0–5000 mg/L (selectable) |
| Accuracy | ≤ ±10% of reading |
| Repeatability | ≤ 5% FS |
| Detection Limit | 0.1 mg/L |
| Minimum Sampling Interval | 40 min (user-configurable) |
| Batch Processing Capacity | 15 or 30 samples per cycle |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP-1113 |
| Measurement Parameter | Total Phosphorus |
| Instrument Type | Online Analyzer |
| Measurement Principle | Molybdate Blue Spectrophotometry (ISO 6878, GB/T 11893-1989) |
| Measurement Range | 0.002–20 mg/L as P |
| Accuracy | ≤ ±5% of reading |
| Detection Limit | 0.01 mg/L |
| Resolution | 0.001 mg/L |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TP-1114 |
| Measurement Parameter | Total Nitrogen (TN) |
| Instrument Type | Online Analyzer |
| Measurement Principle | UV Spectrophotometry after Alkaline Potassium Persulfate Digestion |
| Measurement Range | 0.002–20 mg/L |
| Accuracy | ≤ ±5% of reading |
| Detection Limit | 0.01 mg/L |
| Resolution | 0.001 mg/L |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | TP-1117 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | pH, ORP, Conductivity (4-electrode), Turbidity (fiber-optic), Dissolved Oxygen (fluorescence-based), Temperature, Chlorophyll-a, Oil-in-Water, Ammonia-Nitrogen (optional) |
| Output Interface | RS-485 with MODBUS RTU protocol |
| Sensor Architecture | Digital smart sensors with embedded calibration data |
| Probe Mounting | Waterproof quick-connect interface |
| Maintenance System | Integrated automatic wiper cleaning module |
| Channel Capacity | Up to 6 sensor inputs supporting simultaneous measurement of 7 parameters |
| Compliance | Designed for continuous unattended operation in compliance with ISO 5814, ISO 7888, ISO 7027, ASTM D3370, and EPA Method 180.1 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP-151 |
| Instrument Type | Online |
| Measurement Principle | Electrochemical Galvanic Cell Probe |
| Measurement Range | 0.00–80.00 mg/L |
| Accuracy | ±0.2 mg/L |
| Repeatability | 0.05% |
| Detection Limit | ±2 ppb |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP-170 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Electrochemical Amperometric Sensor |
| Measured Parameter | Free Residual Chlorine |
| Range | 0.01–5.00 mg/L |
| Accuracy | ≤3% of reading |
| Repeatability | ±0.02 mg/L |
| Resolution | 0.01 mg/L |
| Detection Limit | 0.035 mg/L |
| Display | 128×64 Dot-Matrix LCD (Chinese UI) |
| Output Signals | Selectable 0–10 mA, 0–20 mA, or 4–20 mA analog outputs |
| Data Storage | Cyclic memory with auto-overflow management |
| A/D Conversion | 24-bit high-resolution ADC |
| Microcontroller Architecture | Integrated low-power single-chip system |
| PCB Technology | Surface-mount device (SMD) assembly |
| Enclosure Rating | IP65 (industrial indoor/outdoor mounting) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TP-2112 |
| Instrument Type | Portable |
| Measurement Principle | Colorimetric Method (Nessler’s Reagent Spectrophotometry) |
| Measurement Range | 0.02–60 mg/L NH₃–N |
| Accuracy | ≤ ±5% of reading |
| Detection Limit | 0.01 mg/L |
| Measurement Time | 10–15 minutes per sample |
| Batch Capacity | 10 samples per run |
| Display Language | English/Chinese (configurable) |
| Data Storage | 4000 measurement records |
| Power Supply | Rechargeable Li-ion battery with state-of-charge indicator |
| Connectivity | USB, Ethernet, Bluetooth (optional printer support) |
| Compliance | HJ/T 535–2009 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Analyzer |
| Model | TP-306 |
| Measurement Principle | Molybdenum Blue Colorimetric Method (Silicomolybdic Acid Reduction) |
| Display | 5.0-inch TFT Touchscreen (Chinese UI) |
| Optical Source | Imported Monochromatic Cold Light LED |
| Detection Range | Typical for soluble silica (SiO₂) in ultra-pure water (0–200 µg/L, extendable to 1000 µg/L with dilution) |
| Detection Limit | ≤1 µg/L (as SiO₂) |
| Repeatability | ≤±2% FS |
| Calibration | Automatic Blank Calibration & Background Compensation |
| Data Storage | Cyclic memory for ≤256 test records |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Dimensions | 320 × 260 × 180 mm |
| Weight | ~4.2 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Analyzer |
| Model | TP-306 |
| Measurement Principle | Molybdenum Blue Colorimetric Method (Silicomolybdic Acid Reduction) |
| Display | 5.0-inch TFT color touchscreen with Chinese UI |
| Optical Source | Imported monochromatic cold-light LED source |
| Detection Range | Typical for soluble silica (SiO₂) in ultra-pure water (0–200 µg/L, configurable) |
| Calibration | Automatic blank calibration with zero-drift compensation |
| Data Storage | Cyclic memory for ≤256 measurement records |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Compliance | Designed to support ISO 10523, ASTM D859, and GB/T 12149 (Chinese national standard for silica in boiler feedwater) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | TP-307 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Method | Phosphovanadomolybdate Colorimetric Method (Yellow Complex Formation) |
| Display | 5.0-inch TFT Touchscreen with Chinese UI |
| Optical Source | Imported Monochromatic Cold Light LED |
| Data Storage | Cyclic Memory for ≤256 Entries |
| Calibration | Automatic Zero Calibration (Blank Compensation) |
| Power Consumption | Low-Power Microcontroller Architecture |
| Design | Integrated PCB Layout with Surface-Mount Technology (SMT) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Range | 0.1–10 mg/L (multi-segment calibration) |
| Repeatability | ≤5% RSD |
| Accuracy | ±5% of reading |
| LOD | 0.4 mg/L |
| Resolution | 0.01 mg/L |
| Single-Test Duration | 13 min (water bath heating) |
| Display | Backlit LCD with keypad interface |
| Data Storage | 30,000 measurement records with power-loss protection |
| Calibration Curves | 1 built-in standard curve + 96 user-defined curves |
| Connectivity | Ethernet port + USB 2.0 |
| Output | Integrated thermal printer |
| Light Source | Imported long-life cold LED (rated lifetime: 100,000 h) |
| Operating Modes | Standard mode / Continuous measurement mode |
| Reagent Compatibility | Dedicated pre-packaged CODMn test kits (ISO/GB-compliant) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Co., Ltd. |
| Model | TP/1117 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Total Phosphorus, Total Nitrogen, Conductivity, pH, ORP, Dissolved Oxygen (fluorescence-based), Turbidity (fiber-optic), Temperature, Optional: Chlorophyll-a, Oil-in-Water, Ammonia-Nitrogen |
| Sensor Interface | Digital RS485 with MODBUS RTU protocol |
| Max. Simultaneous Probes | 6 (up to 7 parameters) |
| Probe Mounting | Waterproof quick-connect interface |
| Maintenance | Integrated automatic cleaning system |
| Compliance | Designed for continuous operation in accordance with ISO 5667-22, ASTM D3370, and EPA Method 180.1 principles for online water quality monitoring |
| Brand | TimePower |
|---|---|
| Model | TP/201 |
| Detection Principle | Catalytic Bead (Pellistor) Sensor |
| Gas Coverage | H₂, CH₄, C₄H₁₀ (iso-butane), C₃H₈, C₅H₁₂, acetylene, ethylene, gasoline vapor, ethanol, methanol, xylene, and other combustible hydrocarbons & vapors |
| Alarm Threshold | Adjustable (typically 10–50% LEL default) |
| Display | Backlit LCD with digital concentration readout (% LEL) |
| Power Supply | Rechargeable Ni-MH battery with low-voltage warning |
| Certification | Ex ia II CT3 (Intrinsically Safe for Zone 0/1) |
| Operating Temperature | −20 °C to +50 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Enclosure Rating | IP65 |
| Compliance | GB 15322.1–2019, EN 60079-0, EN 60079-11, IEC 61779-1 |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TP/352 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Clark-type Polarographic Sensor |
| Measurement Range | 0.0–20,000.0 µg/L (ppb) |
| Accuracy | ±1.5% of Full Scale or ±3 µg/L |
| Repeatability | ≤1% |
| Resolution | 0.1 µg/L |
| Response Time (T90) | <5 min at 25°C |
| Operating Temperature (Ambient) | 5–45°C |
| Sample Temperature Range | 5–45°C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Power Supply | DC 3.7 V (rechargeable Li-ion battery) |
| Power Consumption | ≤0.5 W |
| Dimensions | 285 mm × 60 mm × 255 mm |
| Weight | 2.28 kg |
| Brand | TimePower |
|---|---|
| Model | TP106 |
| Type | Online Analyzer |
| Origin | Beijing, China |
| Manufacturer | TimePower Instrument Co., Ltd. |
| Measurement Principle | Molybdenum Blue Photometric Method (based on GB/T 12149–2017) |
| Measurement Range | 0.0–200.0 μg/L or 0.0–2000 μg/L (selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤±1% F.S. |
| Drift | <±1% F.S./24 h |
| Response Time | <10 min |
| Cycle Time | ~10 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temperature | 5–50 °C |
| Particulate Limit | <5 µm, non-colloidal |
| Ambient Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Light Source | Monochromatic cold LED |
| Display | 7.0-inch color LCD touchscreen, Chinese interface |
| Output Signals | Isolated 0–20 mA / 4–20 mA / 0–10 mA (configurable) |
| Alarm Outputs | Independent high/low limit and flow-loss alarms per channel |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions | 460 × 280 × 720 mm (W × D × H) |
| Panel Cutout | 670 × 410 mm |
| Weight | 22 kg |
| Channel Options | 1–6 channels configurable |
| Data Storage | 30 days of historical data (timestamped) |
| Reagent Consumption | ~3 L/month per reagent (4 reagents total) |
| Compliance | GB/T 12149–2017 |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | TP106 |
| Instrument Type | Online Analyzer |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP106 |
| Instrument Type | Online Analyzer |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP106 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Molybdenum Blue Photometric Colorimetry |
| Display | 7.0-inch Color LCD Touchscreen (Chinese UI) |
| Measurement Range | 0.0–200.0 μg/L or 0.0–2000 μg/L (selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ±1% F.S. |
| Cycle Time | ~12 min per channel |
| Sampling Flow Rate | 10–40 L/h |
| Sample Temperature | 5–45 °C |
| Sample Particulates | <5 µm, no colloidal matter |
| Ambient Temperature | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Reagent Consumption | ~2 L/month per reagent (4 reagents total) |
| Digital Output | RS232 or RS485 |
| Analog Output | Isolated DC current signal (0–20 mA / 4–20 mA / 0–10 mA selectable) |
| Alarm Outputs | Independent per channel — sample loss, upper/lower limit |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | TP106 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Molybdenum Blue Photometric Method (Silicomolybdate Reduction with 1-Amino-2-Naphthol-4-Sulfonic Acid) |
| Display | 7.0-inch Color TFT Touchscreen (Chinese Interface) |
| Measurement Range | 0.0–200.0 µg/L or 0.0–2000 µg/L (Selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤±1% F.S. |
| Drift | <±1% F.S./24 h |
| Response Time | <10 min |
| Cycle Time | ~10 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temperature | 5–50 °C |
| Suspended Solids | <5 µm, non-colloidal |
| Ambient Temperature | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Reagent Consumption | ~3 L/month per reagent (4 reagents total) |
| Output Signal | Isolated 0–20 mA / 4–20 mA / 0–10 mA (configurable) |
| Alarm Outputs | Independent per channel (flow failure, upper/lower limit) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×H×D) | 460 × 720 × 280 mm |
| Panel Cutout | 670 × 410 mm |
| Weight | 22 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP106 |
| Instrument Type | Online Analyzer |
| Pricing | Upon Request |