Environmental Monitoring Instruments
Filter
Showing 7951–7980 of 9023 results
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | TP3115 |
| Measurement Principle | Photometric Colorimetry (based on Lambert-Beer Law) |
| Measurement Range | 2–500 Hazen (Pt-Co) units |
| Accuracy | ≤ ±5% FS |
| Repeatability | ≤ 5% RSD |
| Cell Type | Cuvette-based |
| Display | 5.0-inch color LCD (English/Chinese switchable) |
| Data Storage | 30,000 measurement records + 96 customizable calibration curves |
| Interface | USB 2.0, Ethernet (RJ45) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 5 W |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Dimensions | 348 × 250 × 145 mm |
| Weight | 2.6 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP3116 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Light Source | Imported Cold LED (100,000 hr lifetime) |
| Display | Large LCD with Keypad Interface |
| Data Storage | 30,000 measurement records |
| Calibration Curves | 1 built-in standard curve + 96 user-defined curves |
| Connectivity | Ethernet port + USB 2.0 |
| Output | Integrated thermal printer |
| Power Backup | Built-in non-volatile memory with power-loss protection |
| Expandability | Modular parameter extension for up to 30+ water quality parameters |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP3116 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP3117 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurable Parameters | Conductivity, Total Cyanide, COD, Ammonia Nitrogen, Total Phosphorus, Total Nitrogen, Turbidity, Suspended Solids (SS) |
| Display | Backlit LCD |
| Light Source | Imported Cold Light LED (Lifespan ≥ 100,000 h) |
| Measurement Modes | Standard Mode / Continuous Mode |
| Digestion-Cuvette Integration | Yes |
| Data Storage | Up to 30,000 records |
| Built-in Thermal Printer | Yes |
| Calibration Curves | 1 Preloaded Standard Curve Library + 96 User-Defined Curves |
| Connectivity | RJ45 Ethernet Port, USB 2.0 |
| Power Supply | AC 220 V ± 10%, 50 Hz |
| Dimensions | 350 × 280 × 180 mm |
| Weight | 5.2 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | TP3117 |
| Instrument Type | Benchtop Laboratory Water Quality Analyzer |
| Measurable Parameters | COD, Ammonia Nitrogen (NH₃-N), Total Phosphorus (TP), Total Nitrogen (TN), Turbidity, Suspended Solids (SS) |
| Measurement Principle | Photometric Colorimetry (Lambert–Beer Law) |
| Display | 5.0-inch color LCD (Chinese/English switchable) |
| Light Source | Imported cold-light LED (100,000 h lifetime) |
| Measurement Modes | Standard or Continuous |
| Data Storage | 30,000 records + 96 customizable calibration curves |
| Connectivity | USB 2.0, RJ45 Ethernet |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | ≤5 W |
| Operating Environment | 5–40 °C, RH ≤85% (non-condensing) |
| Dimensions | 348 × 250 × 145 mm |
| Weight | 2.6 kg (main unit) |
| Digestion Conditions | COD @ 165 °C/15 min |
| Accuracy | ±5% FS |
| Repeatability | ≤5% RSD |
| Chloride Interference Tolerance (COD) | ≤2000 mg/L Cl⁻ |
| Turbidity Range | 0.5–1000 NTU |
| SS Range | 5–500 mg/L |
| COD Range | 5–10,000 mg/L |
| NH₃-N Range | 0.01–50 mg/L |
| TP Range | 0.02–20 mg/L |
| TN Range | 0.5–100 mg/L |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP3211 |
| Measurement Principle | Photometric Colorimetry (K₂Cr₂O₇ Oxidation) |
| Range | 5–2000 mg/L COD |
| Repeatability | ±3% RSD |
| Accuracy | ≤ ±3% of reading (at mid-range), ≤ ±5% F.S. |
| LOD | 0.20 mg/L |
| Resolution | 0.01 mg/L |
| Single-Test Duration | 30 min |
| Chloride Interference Tolerance | ≤ 2000 mg/L Cl⁻ |
| Dimensions | 340 × 250 × 130 mm |
| Weight | 4 kg |
| Power Consumption | <10 W |
| Operating Environment | 5–40 °C, RH ≤85% |
| Power Supply | AC 220 ±22 V, 50 ±0.5 Hz |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP330 |
| Instrument Type | Benchtop |
| Measurement Range | (0.00–9.36) pNa [(0.01 μg/L – 23.0 g/L] |
| Detection Limit | 12 μg/L |
| Response Time | T₉₀ < 3 min at 25 °C |
| Accuracy | ±2 μg/L or ±0.03 pNa (whichever is greater) |
| Temperature Range | 5–45 °C (operational ambient) |
| Input Impedance | ≥1 × 10¹² Ω |
| Resolution | 0.01 μg/L |
| Repeatability | ≤1% |
| Stability | ±1% F.S./4 h |
| Temperature Sensor | Pt1000 |
| Brand | TimePower |
|---|---|
| Model | TP330 |
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Co., Ltd. |
| Type | Benchtop Sodium-Specific Ion Analyzer |
| Measurement Principle | Potentiometric Detection with Solid-State Sodium-Selective Electrode (SSE) |
| Display | 5.0-inch Color TFT Touchscreen |
| Data Storage | Cyclic non-volatile memory with >10-year data retention after power loss |
| A/D Resolution | 24-bit |
| Microcontroller Architecture | Low-power embedded single-chip system |
| Compliance | Designed for laboratory use in accordance with ISO 7888, ASTM D1587, and USP <643> guidelines for sodium measurement in purified water and steam condensate |
| Brand | TimePower |
|---|---|
| Model | TP350 |
| Type | Portable Dissolved Oxygen Analyzer |
| Measurement Principle | Fluorescence Quenching |
| Range | 0.0–100 µg/L, 100–1000 µg/L, 1.00–20.00 mg/L (auto-ranging) |
| Accuracy | ±1.0% FS |
| Resolution | 0.1 µg/L (0–100 µg/L), 1 µg/L (100–1000 µg/L), 0.01 mg/L (1.00–20.00 mg/L) |
| Repeatability | ≤1% |
| Detection Limit | 0 µg/L ±2 µg/L |
| Response Time (T90) | <5 min at 25°C |
| Temperature Sensor | Pt1000 |
| Temp. Measurement Range | 0.0–99.9°C |
| Temp. Compensation Range | 0.1–80.0°C |
| Sample Temp. Range | 5–80°C |
| Ambient Temp. Range | 5–45°C |
| Humidity | ≤90% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | <0.5 W |
| Dimensions | 162 × 82 × 33 mm (L×W×H) |
| Weight | ~320 g |
| Display | 128×64 dot-matrix LCD, Chinese interface |
| Data Storage | Cyclic internal memory with >10-year data retention after power loss |
| Battery Life | Up to 8 hours continuous operation on full charge |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Clark-type Polarographic Sensor |
| Measurement Range | 0.0–100 µg/L (microgram per liter), auto-ranging up to 20.00 mg/L |
| Accuracy | ±1.0% FS |
| Repeatability | ≤1% |
| Detection Limit | ±2 ppb |
| Response Time (T90) | <5 min at 25 °C |
| Temperature Compensation Range | 0–60.0 °C |
| Sample Temperature Range | 5–45 °C |
| Environmental Operating Range | 5–45 °C, ≤90% RH (non-condensing) |
| Display | 128×64 LCD, Chinese interface |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤1 W |
| IP Rating | IP65 |
| Dimensions | 285 × 60 × 255 mm |
| Weight | 2.28 kg |
| Data Storage | Cyclic non-volatile memory, >10 years retention after power loss |
| Battery Life | Up to 8 hours continuous operation (internal rechargeable battery) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TP350 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Clark-type Polarographic Sensor |
| Measurement Range | 0.0–100 µg/L |
| Accuracy | ±1.0% FS |
| Repeatability | ≤1% |
| Detection Limit | ±1.0% FS |
| Resolution | 0.1 µg/L (0–100 µg/L), 1.0 µg/L (100–1000 µg/L), 0.01 mg/L (1.00–20.00 mg/L) |
| Response Time (T90) | <5 min at 25 °C |
| Temperature Compensation Range | 0–60.0 °C |
| Sample Temperature Range | 5–45 °C |
| Operating Ambient | 5–45 °C, ≤90% RH (non-condensing) |
| Enclosure Rating | IP65 |
| Temperature Sensor | Pt1000 |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤1 W |
| Dimensions | 285 × 60 × 255 mm |
| Weight | 2.28 kg |
| Display | 128 × 64 LCD, Chinese interface |
| Data Storage | Cyclic memory with >10-year data retention after power loss |
| Battery Life | Up to 8 hours continuous operation (fully charged) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP350 |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Quenching Method |
| Measurement Range | 0.0–100 µg/L (trace mode), auto-ranging up to 20.00 mg/L |
| Accuracy | ±1.5% FS |
| Repeatability | ≤1% |
| Detection Limit | 2 ppt (0 ± 2 ppt) |
| Response Time (T90) | <5 min at 25 °C |
| Temperature Compensation Range | 0–60.0 °C |
| Sample Temperature Range | 5–45 °C |
| Environmental Operating Range | 5–45 °C, ≤90% RH (non-condensing) |
| Display | 128 × 64 LCD, Chinese interface |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤1 W |
| Dimensions | 285 × 60 × 255 mm |
| Weight | 2.28 kg |
| IP Rating | IP65 |
| Temperature Sensor | Pt1000 |
| Data Storage | Cyclic memory with >10-year retention after power loss |
| Battery Life | Up to 8 hours continuous operation |
| Resolution | 0.1 µg/L (0.0–100 µg/L), 1.0 µg/L (100–1000 µg/L), 0.01 mg/L (1.00–20.00 mg/L) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable |
| Measurement Principle | Polarographic Electrochemical Sensor (Clark-type with PTFE/PE Membrane) |
| Measurement Range | 0.0–100 µg/L, 100–1000 µg/L, 1.00–20.00 mg/L (Auto-ranging) |
| Accuracy | ±1.0% FS |
| Repeatability | ≤1% |
| Detection Limit | ±2 ppb (0 µg/L baseline) |
| Response Time (T90) | <5 min at 25 °C |
| Temperature Compensation | Pt1000 sensor, 0–60.0 °C |
| Sample Temp. Range | 5–45 °C |
| Operating Environment | 5–45 °C, ≤90% RH (non-condensing) |
| IP Rating | IP65 |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤1 W |
| Dimensions | 285 × 60 × 255 mm |
| Weight | 2.28 kg |
| Display | 128 × 64 dot-matrix LCD, Chinese interface |
| Data Storage | Cyclic memory with >10-year non-volatile retention |
| Battery Life | Up to 8 hours continuous operation (internal rechargeable battery) |
| Resolution | 0.1 µg/L (0–100 µg/L), 1.0 µg/L (100–1000 µg/L), 0.01 mg/L (1.00–20.00 mg/L) |
| Brand | TimePower |
|---|---|
| Model | TP351 |
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Co., Ltd. |
| Type | Polarographic Dissolved Oxygen Meter (Clark-type electrode) |
| Display | 128×64 dot-matrix LCD, Chinese interface |
| Measurement Range | 0.00–20.00 mg/L |
| Accuracy | ±1.5% F.S. |
| Resolution | 0.01 mg/L |
| Repeatability | ≤1% |
| Stability | ±1% F.S./4 h |
| Response Time (T90) | <5 min at 25 °C |
| Temperature Sensor | Pt100 |
| Temp. Measurement Range | 0.0–99.9 °C |
| Automatic Temperature Compensation Range | 0.1–60.0 °C |
| Sample Temperature Range | 5–60 °C |
| Operating Ambient | 5–45 °C, ≤90% RH (non-condensing) |
| Storage Temperature | −25–55 °C (electrode must be stored above 0 °C) |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Power Consumption | <5 W |
| Dimensions (L×W×H) | 225 mm × 210 mm × 260 mm |
| Weight | 1.5 kg |
| Standard Accessories | DO meter host, AC adapter, ppm-range polarographic DO electrode with YXI membrane cap, electrolyte refill solution (KCl-based), electrode stand |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Co., Ltd. |
| Type | Benchtop Laboratory DO Meter |
| Measurement Principle | Polarographic Electrochemical Sensor (Clark-type) |
| Range | 0.00–20.00 mg/L |
| Accuracy | ±0.2 mg/L (±1.5% F.S.) |
| Resolution | 0.01 mg/L |
| Repeatability | ≤1% RSD |
| Detection Limit | 2 ppb (O₂) |
| Response Time (T₉₀) | <5 min at 25°C |
| Temperature Compensation Range | 0.1–60.0°C |
| Sample Temp. Range | 5–60°C |
| Display | 128×64 dot-matrix LCD, Chinese interface |
| Power Supply | AC 220 V ±10%, 50 Hz, <5 W |
| Dimensions | 225 × 210 × 260 mm (L×W×H) |
| Weight | 1.5 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TP539 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Compliance Standard | GB/T 511–2010 Petroleum Products and Additives — Determination of Mechanical Impurities (Gravimetric Method) |
| Temperature Control Range (Water Bath & Funnel) | Room Temperature to 90 °C |
| Temperature Control Accuracy | ±1 °C |
| Funnel Temperature Display | LED Digital |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤1200 W |
| Dimensions (Control Box) | 390 × 260 × 130 mm |
| Dimensions (Water Bath) | 90 × 290 × 370 mm |
| Net Weight | 4.8 kg |
| Brand | Tisch |
|---|---|
| Origin | Italy |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | AirHVS |
| Pricing | Upon Request |
| Flow Rate | 200–1300 L/min |
| Standard Cut-Point Flow | 40 CFM (1.133 m³/min) for TSP, PM₁₀, and PM₂.₅ |
| Operating Temperature Range | –30 °C (with optional low-temp kit) |
| Power Supply | 220 VAC |
| Dimensions (H×L×W) | 120 × 37 × 37 cm |
| Weight | 14 kg |
| Housing | Anodized Aluminum |
| Motor | Three-Stage Magnetic Induction Brushless DC Motor |
| Data Interfaces | RS232, USB |
| Display | High-Resolution Backlit LCD |
| Optional Features | GSM/GPRS Remote Monitoring, RH/Temperature Sensors, PM₂.₅ Retrofit Kit |
| Brand | TISCH |
|---|---|
| Origin | USA |
| Model | TE-20-800 |
| Sampling Flow Rate | 28.3 L/min |
| Aerodynamic Diameter Range | >9.0 µm to <0.3 µm |
| Stage Count | 8 impactor stages + pre-separator |
| Filter Diameter | 81 mm |
| Material | Anodized aluminum alloy body with silicone O-rings |
| Compliance | Meets US EPA, OSHA, ACGIH, and ISO 21501-4 referenced cascade impactor performance criteria |
| Collection Efficiency | High-fidelity inertial impaction with minimized particle bounce and re-entrainment |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | BC 251 |
| Flow Rate | 3.5 L/min |
| Collection Media | 15 mL centrifuge tube + 1.5 mL centrifuge tube + backup filter |
| Particle Separation Standard | ACGIH/ISO 7708 (Inhalable & Thoracic Fractions) |
| Compliance | NIOSH-developed personal sampler |
| Application | Viral aerosol collection (e.g., influenza, SARS-CoV-2) |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | DS2.5 |
| Typical Configuration | PM2.5 Sampling System |
| Pump Type | Pulse-Driven Diaphragm Pump |
| Rated Lifespan | 10,000 hours continuous operation |
| Flow Rate Range | 0–6 L/min (adjustable) |
| Default Operating Flow | 5 L/min |
| Timer Function | 7-day programmable scheduler with 24-hour real-time clock |
| Power Supply | AC/DC input + sealed rechargeable battery (12 Ah) |
| Battery Runtime | ≥12 hours at 5 L/min |
| Low-Battery Protection | automatic shutdown with visual alert |
| Low-Flow Alert | automatic shutdown with visual alert |
| Flow Control | precision electronic mass flow regulation |
| Filter Holder | standard 47 mm membrane filter cassette |
| Inlet Cut-Point | 10 µm (PM₁₀) with optional PM₂.₅ cyclone or impactor |
| Enclosure Rating | NEMA 4X (weatherproof, dust-tight, corrosion-resistant) |
| Weight | 6.8 kg (15 lbs) including battery |
| Dimensions | 24.1 × 20.3 × 27.9 cm (H×W×D) |
| Brand | TISCH |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TEI |
| Price | Upon Request |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-10-800 |
| Sampling Principle | Inertial Impaction |
| Flow Rate | 28.3 L/min |
| Operating Humidity Range | 0–95% RH (non-condensing) |
| Stage Configuration | 6-stage cascade impactor with defined aerodynamic cut-points |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-10-800X |
| Sampling Principle | Inertial Impaction |
| Flow Rate | 28.3 L/min |
| Operating Temperature | <35°C |
| Operating Relative Humidity | <90% RH |
| Material | Anodized Aluminum Alloy |
| Stage Count | 6 |
| Aerodynamic Cut-Points (at 28.3 L/min) | Stage 1 ≥7.1 µm, Stage 2 4.7–7.1 µm, Stage 3 3.3–4.7 µm, Stage 4 2.1–3.3 µm, Stage 5 1.1–2.1 µm, Stage 6 0.65–1.1 µm |
| Dimensions (Impactor Only) | 133 mm Ø × 88.9 mm H |
| Weight (Impactor Only) | 2.75 kg |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-1000 PUF |
| Flow Rate | 280 L/min (10 CFM) |
| Filter Medium | 4" Quartz Fiber Filter (TE-QMA4) |
| Sampling Modules | Dual-Stage Particulate & Gas Sampling Module (TE-1002) |
| Flow Control | Voltage-Regulated 2-Stage Vacuum Motor with Mechanical Timer (7-Day, TE-5007) |
| Pressure Gauge | 0–100" H₂O Magnehelic® (TE-1005) |
| Elapsed Time Indicator | TE-5010 |
| Motor | TE-116125 (220 V / 50 Hz, Start Current: 15 A, Running Current: 5 A) |
| Compliance | EPA Methods TO-4A, TO-9A, TO-13A |
| Sample Compatibility | LC-Ready SVOC Extracts (e.g., PCBs, PAHs, organochlorine pesticides) |
| Configuration | Integrated Field-Deployable Sampler with Anodized Aluminum Frame |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-10557 (VFC) / TE-300-310 (MFC) |
| Flow Rate | 40 CFM (1.13 m³/min, adjustable) |
| Filter Media Support | 8" × 10" Micro-Quartz (TE-QMA), Teflon, or PTFE |
| Compliance | EPA Reference Method RFPS-0202-141, 40 CFR Part 50 Appendix B |
| Power Supply | 110 V / 60 Hz (TE-116311) or 220 V / 50 Hz (TE-116312) |
| Motor | Two-stage vacuum, 0.6 HP |
| Data Logging | Continuous temperature, pressure, flow (5-min intervals), CSV export via SD card |
| Control Architecture | Microprocessor-based with auto-calibration, real-time flow compensation, alarm-driven status indicators |
| Brand | TISCH |
|---|---|
| Origin | USA |
| Model | TE-123, TE-323 |
| Compliance | EPA TO-14/TO-15 |
| Flow Rate | 1–300 mL/min |
| Power Options | 240 VAC 50/60 Hz, 12 VDC, Solar Panel, UPS (TE-323), Battery Backup |
| Mounting | 19″ Rack or Desktop w/Rubber Feet |
| Condensate Trap | Integrated |
| Valve Configuration | 3-Way Stainless Steel Valves |
| Channel Capacity | Up to 7 (TE-123), Up to 8 (TE-323, Custom) |
| Display | Backlit LCD (4×20 chars), Touchscreen (TE-123), Siemens PLC Interface (TE-323) |
| Sample Line Purge Pump | High-Flow Integrated |
| Pre-Filter Material | PTFE |
| Pressure Gauge | Stainless Steel Vacuum Gauge |
| Data Logging | Time-Stamped Flow & Volume Integration |
| Enclosure | 304 Stainless Steel Canister Housing |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-20-800 |
| Sampling Flow Rate | 28.3 L/min (optional 60 L/min and 90 L/min) |
| Aerodynamic Diameter Range | >9.0 µm to <0.3 µm |
| Stage Count | 8 |
| Collection Substrate | 81 mm filter or stainless steel plates |
| Pre-separator Cut-point | ≥10.0 µm |
| Compliance | US Federal Reference Method for PM10/PM2.5, EPA/OSHA/ACGIH inhalable & thoracic fraction criteria, ISO 21501-4, ASTM D7251 |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-20-800 |
| Sampling Flow Rate | 28.3 L/min |
| Stage Cut Points (aerodynamic diameter) | Pre-separator ≥10.0 µm, Stage 0: 9.0 µm, Stage 1: 5.8 µm, Stage 2: 4.7 µm, Stage 3: 3.3 µm, Stage 4: 2.1 µm, Stage 5: 1.1 µm, Stage 6: 0.7 µm, Stage 7: 0.4 µm |
| Collection Substrate | 81 mm circular filters or petri dishes |
| Material | Anodized aluminum impactor stages, stainless steel collection plates, silicone O-rings |
| Compliance | Meets U.S. EPA, OSHA, and ACGIH criteria for respirable and inhalable particulate fractionation |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-20-800X |
| Flow Rate | 28.3 L/min |
| Cut-Point Range (aerodynamic diameter) | 10.0 µm to 0.4 µm |
| Stage Count | 8 |
| Filter Diameter | 81 mm |
| Compliance | EPA, OSHA, ACGIH, USP <1117>, ISO 14644-1 (indirect), FDA 21 CFR Part 11 (with validated software) |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-3000P |
| Flow Rate Range | 15–29 CFM |
| Filter Holder Diameter | 10–11 cm |
| Motor | 7/8 HP, 3-Stage Vacuum Pump |
| Voltage Options | 110 V / 60 Hz (TE-114787) or 220 V / 50 Hz (TE-114789) |
| Flow Measurement | Integrated Rotameter (TE-2000P-2) |
| Runtime Meter | Mechanical Elapsed Time Indicator (TE-5012-6 / TE-5010-6x) |
| Filter Compatibility | GF/C Glass Fiber (e.g., Whatman Polbag TE-10453) |
| Mounting | Optional Tripod (TE-2000P-1) |
| Compliance | Meets Procter & Gamble (P&G) Aerosol Collection Efficiency Standard |