Environmental Monitoring Instruments
Filter
Showing 7921–7950 of 9029 results
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | TP152 |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Quenching (Optical) |
| Measurement Range | 0.00–20.00 mg/L |
| Accuracy | ±1.5% F.S. |
| Repeatability | ≤1% |
| Detection Limit | ±2 ppb |
| Response Time (T90) | <5 min at 25 °C |
| Resolution | 0.01 mg/L |
| Temperature Compensation Range | 0–60.0 °C |
| Sample Temperature Range | 5–60 °C |
| Ambient Temperature Range | 5–45 °C |
| Humidity | ≤90% RH (non-condensing) |
| Storage/Transport Temp | −25–55 °C (electrode >0 °C) |
| Enclosure Rating | IP65 |
| Display | 128×64 LCD, Chinese interface |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤15 W |
| Dimensions (H×W×D) | 145×120×150 mm |
| Panel Cutout | 138×138 mm |
| Weight | 0.64 kg |
| Output Signals | 0–10 mA / 0–20 mA / 4–20 mA (selectable, load <300 Ω) |
| Relay Output | AC 220 V / 3 A or DC 30 V / 3 A |
| Data Storage | Cyclic memory with >10-year data retention after power loss |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP153 |
| Instrument Type | Online |
| Measurement Principle | Fluorescence-based (Optical) Method |
| Measurement Range | 0.00–20.00 mg/L |
| Accuracy | ±0.2 mg/L |
| Repeatability | 0.05% |
| Detection Limit | ±2 ppb |
| Output Signals | 0–10 mA / 0–20 mA / 4–20 mA (selectable, load < 300 Ω) |
| Relay Alarm | AC 220 V / 3 A or DC 30 V / 3 A |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤15 W |
| Display | 128×64 dot-matrix LCD with Chinese interface |
| Resolution | 0.01 mg/L |
| Response Time (T90) | <5 min at 25 °C |
| Temperature Compensation Range | 0–60.0 °C |
| Sample Temperature Range | 5–45 °C |
| Ambient Operating Temperature | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Storage & Transport Temperature | −25 to +55 °C (electrode must be stored above 0 °C) |
| Dimensions (H×W×D) | 98 mm × 130 mm × 98 mm |
| Panel Cutout | 94 mm × 94 mm |
| Weight | 0.5 kg |
| Data Storage | Cyclic memory with automatic overwrite |
| Power Failure Data Retention | >10 years |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TP170 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Electrochemical Amperometric Sensor |
| Measured Parameter | Free Residual Chlorine |
| Range Options | 0.00–0.5 / 2 / 5 / 10 / 20 / 50 ppm (customizable) |
| Accuracy | ±1.5% F.S. |
| Repeatability | ≤1% |
| Resolution | 0.01 ppm |
| Detection Limit | 1 ppm |
| Response Time (T90) | <1 min at 25°C |
| Temperature Compensation Range | 0–60°C |
| Sample Temperature Range | 5–60°C |
| Ambient Operating Temperature | 5–45°C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Storage/Transport Temp | −25–55°C (electrode excluded |
| Display | 128×64 dot-matrix LCD with Chinese interface |
| Output Signals | Isolated 0–10 mA, 0–20 mA or 4–20 mA (user-selectable, load <300 Ω) |
| Alarm Relays | 2 SPST NO relays (configurable, AC220V/3A or DC30V/3A) |
| Enclosure Rating | IP65 |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤15 W |
| Dimensions (W×H×D) | 145×120×150 mm |
| Panel Cutout | 138×138 mm |
| Weight | 0.64 kg |
| Data Logging | Cyclic memory with auto-overflow overwrite |
| A/D Conversion | 24-bit |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TP1803 |
| Pricing | Available Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Online Multicomponent Gas Analyzer |
| Model | TP203 |
| Detection Principle | Temperature-Compensated Thermal Conductivity Detection (TCD) |
| Response Time | ≤120 s |
| Repeatability | ±0.1% (within 90–100% SF₆ range) |
| Measurement Range | 0–100% SF₆ by volume |
| Resolution | 0.01% |
| Sampling Flow Rate | 0.5–0.6 L/min |
| Operating Temperature | −10 to +50 °C |
| Power Supply | Internal Li-ion battery (6600 mAh), ≤50 W |
| Battery Life | ≥8 h |
| Charging Time | ≥4 h (intelligent charge protection) |
| Dimensions | 310 × 290 × 280 mm |
| Weight | ~4 kg |
| Display | High-resolution true-color TFT touchscreen |
| Data Storage | Up to 100 records |
| Interface | Standard USB port for data export to USB drive |
| Environmental Monitoring Compliance | Designed for IEC 62271-1, IEEE C37.122.1, and DL/T 917–2017 SF₆ gas quality monitoring applications |
| Brand | Timepower |
|---|---|
| Model | TP204 |
| Sensor Technology | Electrochemical (Alpha, UK) |
| Measurement Principle | Direct electrochemical detection of SF₆ decomposition gases |
| Measured Gases | H₂S (0–100 ppm), CO (0–1000 ppm), SO₂ (0–100 ppm) |
| Detection Limit | ≤0.1 ppm (all gases) |
| Accuracy | ±0.5 ppm (≤10 ppm) |
| Flow Rate | 0.5–0.6 L/min (electronic mass flow sensor) |
| Operating Temperature | −10 to +50 °C |
| Power Supply | Rechargeable Li-ion battery (4400 mAh) |
| Runtime | ≥8 h |
| Charging Time | ≥4 h (smart charging protection) |
| Data Storage | 100 test records |
| Display | 5-inch color touchscreen (graphical + numeric) |
| Interface | USB 2.0 for data export |
| Dimensions | 310 × 290 × 280 mm |
| Weight | ~5 kg |
| Compliance | Designed for IEC 60480, IEEE C37.122.1, DL/T 1535–2016, and compatible with SF₆ gas handling protocols in high-voltage GIS/GCB maintenance |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | TP206 |
| Pricing | Upon Request |
| Calibration Range | 0–1 MPa (absolute pressure) |
| Accuracy Class | 0.1 |
| Repeatability | ±0.1% F.S. @ 20°C |
| Pressure Resolution | 0.001 MPa |
| Measurement Time | ≤60 s (per test at rated pressure 0.6 MPa) |
| Operating Temperature | −10 to +55 °C |
| Relative Humidity | 5–90% RH |
| Power Supply | Built-in rechargeable Li-ion battery (4400 mAh) |
| Battery Life | ≥8 h |
| Charging Time | ≥4 h (with intelligent charge protection) |
| Dimensions | 310 × 290 × 280 mm |
| Weight | 5 kg |
| Display | 800 × 480 pixel color TFT touchscreen |
| Input Pressure Range | 0.9–1.0 MPa (gauge) |
| Burst Pressure Rating | 1.1 MPa (gauge) for 1 min |
| Interface | USB port (supports USB flash drives ≤4 GB) |
| Relay Types Supported | Single alarm, single lockout, single alarm + single lockout, single alarm + dual lockout |
| Core Sensors | MEAS aerospace-grade high-precision pressure transducers |
| Data Handling | Onboard storage, thermal printing, USB data export |
| Compliance | DL/T 259–2012, DL/T 596–1996 |
| Brand | TimePower |
|---|---|
| Model | TP207 |
| Type | Online Multicomponent SF₆ Gas Analyzer |
| Origin | Beijing, China |
| Manufacturer | TimePower (Domestic Producer) |
| Measurement Principles | Electrochemical (SO₂, H₂S, CO), Semiconductor/NDIR (HF, optional), Capacitive Dew Point & Thermal Conductivity (SF₆ Purity) |
| Flow Rate | ~900 mL/min |
| Repeatability | ±2% FS for SO₂, H₂S, CO |
| Detection Ranges | SO₂: 0–100 µL/L |
| H₂S | 0–100 µL/L |
| CO | 0–1000 µL/L |
| HF (optional) | 0–10 µL/L |
| SF₆ Purity | 0–100% vol |
| Dew Point | –80 to +20°C |
| Operating Pressure | <1 MPa |
| Display | 800×480 TFT capacitive touchscreen |
| Data Output | USB 2.0 interface |
| Storage Capacity | 1000 records |
| Power Supply | Rechargeable Li-ion battery + AC/DC adapter |
| Dimensions | 400 × 370 × 180 mm |
| Weight | ~8 kg |
| Operating Environment | –20 to +50°C, <80% RH |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | TP2111 |
| Instrument Type | Portable |
| Measurement Principle | Photometric Colorimetry (based on Lambert-Beer Law) |
| Wavelength | 610 nm (for medium/high range), 420 nm (for low range) |
| Measurement Range | 0–2000 mg/L COD (dilution applicable for higher concentrations) |
| Accuracy | ≤ ±5% FS |
| Repeatability | ≤ 3% RSD |
| Detection Limit | 0.1 mg/L |
| Measurement Time | 15 min per batch |
| Batch Capacity | 15 or 30 samples |
| Optical System | Imported cold-light source with high photometric stability |
| Temperature Control | PID-controlled heating block, 0–200 °C adjustable (COD digestion set at 165 °C) |
| Temperature Accuracy | ±1 °C |
| Digestion Time | 1–999 min programmable (standard COD digestion: 15 min) |
| Data Storage | 50 calibration curves + 500 measurement records with timestamp (YYYY-MM-DD hh:mm:ss), absorbance, and transmittance |
| Power Supply | Rechargeable lithium-ion battery |
| Enclosure | Molded ABS housing, IP65 rated |
| Dimensions (Analyzer) | 80 × 230 × 55 mm |
| Dimensions (Digestor) | 105 × 160 × 90 mm |
| Weight (Analyzer) | 0.5 kg |
| Weight (Digestor) | 1.0 kg |
| Interface | USB port for data export and PC connectivity |
| Data Protection | Built-in power-loss memory retention |
| Chloride Interference Tolerance | ≤ 2000 mg/L Cl⁻ |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | TP220 |
| Pricing | Upon Request |
| Measurement Principle | Two-electrode AC conductance (1–3 kHz sine wave) |
| Cell Constants Supported | K = 0.01, 0.1, 1.0, 10.0 cm⁻¹ |
| Measurement Range | 0.000–30,000 µS/cm (auto-ranging across four K-values) |
| Resolution | 0.001 µS/cm |
| Accuracy | ±2.5% FS |
| Repeatability | ≤1% |
| Temperature Sensor | Pt1000 RTD |
| Temp Compensation Range | 0–60 °C |
| Sample Temp Range | 5–60 °C |
| Ambient Temp Range | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤1 W |
| Dimensions | 80 × 30 × 175 mm |
| Weight | 0.26 kg |
| Display | 128×64 dot-matrix LCD, Chinese UI |
| Data Storage | Cyclic memory with >10-year retention after power loss |
| Battery Life | Up to 8 hours (rechargeable internal battery) |
| Backlight | Adjustable LED backlight |
| A/D Converter | 24-bit |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | TP250 / TP350 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Polarographic Electrochemical Sensor (Clark-type with PTFE/PE Membrane) |
| Measurement Range | (0.00–100) µg/L, (100–1000) µg/L, (1.00–20.00) mg/L (auto-ranging) |
| Accuracy | ±1.0% FS |
| Repeatability | ≤1% |
| Resolution | 0.01 µg/L (0–100 µg/L), 1.0 µg/L (100–1000 µg/L), 0.01 mg/L (1.00–20.00 mg/L) |
| Response Time (T90) | <5 min at 25 °C |
| Operating Ambient Temperature | 5–45 °C |
| Sample Temperature Range | 5–45 °C |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤1 W |
| Dimensions | 285 × 60 × 255 mm |
| Display | 128 × 64 dot-matrix LCD with Chinese interface |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower Co., Ltd. |
| Type | Portable |
| Measurement Principle | Fluorescence Quenching Method |
| Range | 0.00–20.00 mg/L |
| Accuracy | ±1.5% FS |
| Repeatability | ±1% |
| Detection Limit | 2 ppb |
| Resolution | 0.01 mg/L |
| Response Time (T90) | <5 min at 25 °C |
| Temperature Compensation | Pt1000 sensor, 0–60 °C |
| Sample Temp. Range | 5–60 °C |
| Operating Ambient | 5–45 °C, ≤90% RH (non-condensing) |
| Storage Temp. | −25 to +55 °C (electrode excluded |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | ≤0.5 W |
| Dimensions | 80 × 30 × 175 mm |
| Weight | 0.26 kg |
| Display | 128×64 dot-matrix LCD with Chinese interface |
| Data Storage | Cyclic memory with 10+ years offline retention (battery-backed) |
| Battery Life | Up to 8 hours continuous operation |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP251 Timepower |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Quenching Method |
| Measurement Range | 0.00–20.00 mg/L |
| Accuracy | ±0.2 mg/L |
| Repeatability | ≤1% |
| Detection Limit | 2 ppb (typical baseline offset) |
| Resolution | 0.01 mg/L |
| Response Time (T90) | <5 min at 25°C |
| Temperature Compensation Range | 0.0–60.0°C |
| Sample Temperature Range | 5–60°C |
| Operating Ambient Temperature | 5–45°C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Storage/Transport Temperature | −25–55°C (electrode ≥0°C) |
| Display | 128×64 dot-matrix LCD with Chinese interface |
| Power Supply | AC 220±22 V, 50±1 Hz |
| Power Consumption | ≤1 W |
| Battery Life | Up to 8 hours continuous operation |
| Dimensions | 80 × 30 × 175 mm |
| Weight | 0.26 kg |
| Output | 4–20 mA (load <300 Ω) |
| Relay Output | AC 220 V / 3 A or DC 30 V / 3 A |
| Data Storage | Cyclic memory with >10-year data retention after power loss |
| A/D Converter | 24-bit high-precision ADC |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TP303 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Infrared Absorption Spectrophotometry (Triple-Wavenumber Method per HJ 637–2018) |
| Spectral Range | 3400 cm⁻¹ to 2400 cm⁻¹ |
| Detection Limit | <0.2 mg/L (as aqueous solution concentration) |
| Accuracy | ±2% |
| Spectral Resolution | 1 cm⁻¹ |
| Measurement Frequency | 7 scans per analysis |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | TP303 |
| Application | Laboratory Use |
| Measurement Principle | Infrared Spectrophotometry (Fourier-transform-free, fixed-wavelength dual-beam) |
| Measurement Range | 0.02–800 mg/L (in extractant, e.g., tetrachloroethylene) |
| Detection Limit | <0.2 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.1 mg/L |
| Measurement Frequency | 7 analyses per minute |
| Compliance | HJ 637–2018 (China National Standard) |
| Brand | Timepower |
|---|---|
| Model | TP304 |
| Origin | Beijing, China |
| Manufacturer | Timepower (Domestic Producer) |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameter | Dissolved Iron (Fe²⁺/Fe³⁺) |
| Measurement Principle | Photometric Colorimetry (1,10-Phenanthroline Method) |
| Display | 5.0-inch Touchscreen Color LCD (Chinese Interface) |
| Measurement Range | 0.00–200.0 μg/L |
| Accuracy | ±3% of Full Scale |
| Resolution | 0.1 μg/L |
| Repeatability | ≤1% RSD |
| Stability | ±1.5% F.S./4 h |
| Light Source | Imported Monochromatic Cold LED |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Operating Temperature | 5–45 °C |
| Operating Humidity | ≤90% RH (non-condensing) |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Data Storage | Cyclic memory for up to 256 test records |
| Calibration | Automatic blank calibration |
| Compliance Standard | Based on Chinese National Standard GB/T 5750.6–2023 (Standard Methods for Examination of Drinking Water – Metals Section), aligned with ISO 8573-1 and ASTM D1068 for iron quantification in low-conductivity water matrices |
| Brand | TimePower |
|---|---|
| Model | TP305 |
| Origin | Beijing, China |
| Manufacturer | TimePower (Domestic Producer) |
| Instrument Type | Benchtop Multi-Ion Analyzer |
| Measurement Principle | Photometric Colorimetry (Bicinchoninone Oxaldihydrazone Method) |
| Detection Range | 0.00–200 µg/L (ppb) |
| Detection Limit | 2 µg/L |
| Full-Scale Accuracy | ±3% F.S. |
| Repeatability | ≤1% |
| Stability | ±1.5% F.S. / 4 h |
| Resolution | 0.1 µg/L |
| Response Time | 1 s |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Display | 5.0-inch capacitive color touchscreen (Chinese UI) |
| Brand | Timepower |
|---|---|
| Model | TP306 |
| Origin | Beijing, China |
| Manufacturer | Timepower (Producer) |
| Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Colorimetric Photometry (Molybdenum Blue Method) |
| Range | 0.0–200.0 μg/L or 0.0–2000 μg/L |
| Accuracy | ±2% F.S. |
| Resolution | 0.1 μg/L |
| Repeatability | ≤1% |
| Stability | ±1% F.S./4h |
| Display | 5.0-inch TFT color touchscreen (Chinese UI) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Environmental Operating Conditions | 5–45 °C, ≤90% RH (non-condensing) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Benchtop Laboratory Analyzer |
| Model | TP306 |
| Measurement Principle | Molybdenum Blue Colorimetric Method (Silicomolybdic Acid Reduction) |
| Display | 5.0-inch TFT color touchscreen with Chinese UI |
| Optical Source | Imported monochromatic cold-light LED (peak λ = 650 nm ± 5 nm) |
| Detection Range | 0–200 µg/L SiO₂ (extendable to 1000 µg/L via dilution) |
| Resolution | 0.1 µg/L |
| Accuracy | ±2% FS or ±1 µg/L (whichever is greater) |
| Repeatability | ≤1.5% RSD |
| Blank Calibration | Automatic zero-point and electronic drift compensation |
| Data Storage | Cyclic memory for up to 256 test records |
| Power Supply | AC 220 V ± 10%, 50/60 Hz |
| Dimensions | 320 × 240 × 180 mm |
| Weight | 4.2 kg |
| Compliance | Designed per GB/T 12149–2019 (Chinese Standard for Silica Determination in Boiler Water and Feedwater), ASTM D859–22 (Standard Test Method for Silica in Water), and ISO 10523:2022 (Water Quality — Determination of pH) |
| Brand | Timepower |
|---|---|
| Model | TP306 |
| Type | Benchtop Laboratory Analyzer |
| Origin | Beijing, China |
| Manufacturer | Timepower (Producer) |
| Measurement Principle | Photometric Colorimetry (Molybdenum Blue Method) |
| Detection Range | 0.0–200.0 μg/L or 0.0–2000 μg/L |
| Accuracy | ±2% F.S. |
| Resolution | 0.1 μg/L |
| Repeatability | ≤1% |
| Stability | ±1% F.S./4 h |
| Display | 5.0-inch TFT color touchscreen (Chinese UI) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Environmental Operating Conditions | 5–45 °C, ≤90% RH (non-condensing) |
| Data Storage | 256 entries with auto-overflow overwrite |
| Key Features | Built-in blank calibration, baseline compensation, automatic timing prompt, cold LED light source, single-chip microcontroller architecture, SMT-based high-integration PCB design |
| Brand | Timepower |
|---|---|
| Model | TP306 |
| Type | Benchtop Laboratory Silicate Analyzer |
| Origin | Beijing, China |
| Manufacturer | Timepower (Beijing) Technology Co., Ltd. |
| Application | Soluble silica and silicate quantification in ultrapure water, condensate, boiler feedwater, and process streams for power generation, pharmaceuticals, semiconductor manufacturing, and chemical processing |
| Measurement Principle | Colorimetric photometry based on molybdenum blue reduction method (ASTM D859, ISO 10523, USP <643>) |
| Display | 5.0-inch capacitive touchscreen LCD (Chinese interface) |
| Range | 0.0–200.0 µg/L or 0.0–2000 µg/L (user-selectable) |
| Accuracy | ±2% of full scale |
| Resolution | 0.1 µg/L |
| Repeatability | ≤1% RSD |
| Stability | ±1% F.S./4 h |
| Operating Environment | 5–45 °C, ≤90% RH (non-condensing) |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Data Storage | Cyclic memory for up to 256 measurements with auto-overflow overwrite |
| Key Features | Integrated optical path design, imported monochromatic cold-light source, onboard blank calibration, automatic timing prompt, baseline compensation algorithm, low-power MCU architecture, surface-mount PCB assembly |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP306 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Photometric Colorimetry (Molybdenum Blue Method) |
| Display | 5.0-inch TFT color touchscreen, Chinese interface |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Measurement Range | 0–200 µg/L and 0–2000 µg/L (selectable) |
| Accuracy | ±2% FS |
| Resolution | 0.1 µg/L |
| Repeatability | ≤1% |
| Stability | ±1% FS / 4 h |
| Compliance | GB/T 12149–2019 (Chinese National Standard for Silica Determination in Water by Molybdenum Blue Spectrophotometry) |
| Data Storage | Up to 256 entries with circular overwrite |
| Calibration | Blank calibration, optional multi-point curve calibration |
| Key Features | Built-in timer alert, baseline compensation, cold LED light source, SMD circuitry, single-chip microcontroller architecture |
| Brand | TimePower |
|---|---|
| Model | TP306 |
| Type | Benchtop Laboratory Silicate Analyzer |
| Measurement Principle | Colorimetric Analysis (Molybdenum Blue Method) |
| Display | 7.0-inch TFT Touchscreen (Chinese/English Switchable) |
| Range | (0.0–200.0) μg/L or (0.0–2000) μg/L (User-Selectable) |
| Accuracy | ±2.0% F.S. |
| Resolution | 0.01 μg/L |
| Repeatability | ≤1.0% F.S. |
| Stability | ±1% F.S./4 h |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Dimensions | 260 × 200 × 180 mm |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Weight | 3.2 kg |
| Origin | Beijing, China |
| Manufacturer | TimePower Instrument Co., Ltd. |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TP307 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Phosphomolybdenum Yellow Colorimetric Method (ISO 6878, ASTM D859) |
| Display | 5.0-inch TFT color touchscreen with Chinese UI |
| Optical Source | Imported monochromatic cold-light LED (λ = 420 nm ± 2 nm) |
| Data Storage | Circular buffer for ≤256 measurement records |
| Calibration | Automatic zero-point compensation via blank calibration |
| Power Consumption | Low-power embedded MCU architecture |
| Enclosure Design | Integrated chassis with surface-mount technology (SMT) PCB assembly |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Analyzer |
| Model | TP307 |
| Measurement Method | Phosphovanadomolybdate Colorimetric Method (ISO 6878, ASTM D859) |
| Display | 5.0-inch TFT color touchscreen with Chinese UI |
| Optical Source | Imported monochromatic cold-light LED (λ = 420 nm ± 2 nm) |
| Data Storage | Cyclic memory for ≤256 measurement records with auto-overflow overwrite |
| Calibration | Zero-point blank calibration with drift compensation |
| Power Supply | AC 220 V ± 10 %, 50/60 Hz |
| Dimensions | 320 × 260 × 180 mm |
| Weight | 4.2 kg |
| Compliance | Designed for ISO/IEC 17025-compliant labs |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TP307 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | TP307 |
| Instrument Type | Benchtop |
| Measuring Range | 0–20 mg/L (optional 0–50 mg/L) |
| Detection Limit | 1 ppm (1 mg/L) |
| Response Time | 1 s |
| Measurement Accuracy | ±2% F.S. |
| Resolution | 0.01 mg/L |
| Repeatability | ≤1% |
| Stability | ±1% F.S./4 h |
| Operating Temperature | 5–45 °C |
| Operating Humidity | ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Display | 5.0-inch color touchscreen LCD with Chinese interface |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TP308 |
| Instrument Type | Online/Portable Hybrid Analyzer |
| Measurement Principle | Colorimetric Analysis via p-Dimethylaminobenzaldehyde (p-DMAB) Reaction |
| Display | 5.0-inch TFT Touchscreen with Chinese UI |
| Optical Source | Imported Monochromatic Cold Light LED |
| Microcontroller | Advanced Low-Power Single-Chip Architecture |
| Calibration | Automatic Zero Calibration (Blank Compensation) |
| Data Storage | Cyclic Memory for ≤256 Records |
| Compliance | Designed for ASTM D1385-18 (Standard Test Method for Hydrazine in Water), ISO 7888:2019 (Water Quality – Determination of Hydrazine), and Power Plant Chemistry Guidelines per EPRI TR-102491 |
| Brand | Timepower |
|---|---|
| Model | TP308 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Price | Upon Request |
| Display | 5.0-inch color touch LCD (Chinese interface) |
| Measurement Principle | Photometric colorimetry via p-dimethylaminobenzaldehyde (p-DMAB) reaction under acidic conditions |
| Measuring Range | 0–100 µg/L |
| Accuracy | ±2% FS |
| Resolution | 0.1 µg/L |
| Repeatability | ≤1% |
| Stability | ±1% FS / 4 h |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Data Storage | 256 cyclic records |
| Calibration | Blank calibration and curve calibration supported |
| Compliance | Based on Chinese national standard method for hydrazine determination using p-DMAB |
| Brand | TimePower |
|---|---|
| Model | TP309 |
| Origin | Beijing, China |
| Manufacturer | TimePower Instrument Co., Ltd. |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameter | Turbidity |
| Measurement Range | 0.0–100 NTU / 100–1000 NTU |
| Range Switching | Auto or Manual |
| Accuracy | ±2% F.S. (0.0–100 NTU), ±5% F.S. (100–1000 NTU) |
| Resolution | 0.01 NTU (low range), 0.1 NTU / 1 NTU (high ranges) |
| Repeatability | ≤1% |
| Stability | ±1% F.S. / 4 h |
| Light Source | Imported monochromatic cold LED |
| Display | 5.0-inch capacitive color touchscreen (Chinese UI) |
| Data Storage | Up to 256 records (circular buffer) |
| Calibration | Formazin-based zero and multi-point calibration per Chinese national standard (GB/T 13200–1991) |
| Power Supply | AC 85–265 V, 45–65 Hz, ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |