Environmental Monitoring Instruments
Filter
Showing 7981–8010 of 9023 results
| Brand | Tisch |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Import Status | Imported |
| Model | TE-323 |
| Typical Configuration | Multi-Channel Integrated Air Sampler |
| Power Options | 240 V AC, 50/60 Hz |
| Flow Rate Range | 1–300 mL/min |
| Sample Container | 6-L Silonite®-coated Electropolished Stainless Steel Canister |
| Fill Time | ≤40 min to 10 psi |
| Channel Capacity | Standard 3 channels (expandable to 8) |
| Display | Backlit LCD (4 × 20 characters) |
| Control System | Siemens PLC-based Embedded Controller |
| Condensate Trap | Integrated |
| Pressure Monitoring | Individual Stainless Steel Vacuum Gauge per Channel |
| Flow Control | Three-Way Solenoid Valves with Precision Mass Flow Regulation |
| Data Logging | Timestamped Event Logs with Channel-Specific Start/Stop/Alarm Records |
| Rack Mounting | 19-inch EIA Compliant |
| Footprint | Desktop or Rack-Mountable with Rubber Isolation Feet |
| Compliance | EPA Method TO-14A and TO-15 Certified Sampling Platform |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | TE-423 |
| Pricing | Upon Request |
| Channels | 3 |
| Sampling Flow Rate | 1 mL/min to 2 SLPM |
| Power Supply | 118 VAC, 50/60 Hz, 3 A |
| Control Interface | Touchscreen + Front-panel LCD |
| Ozone Scrubber | Temperature-controlled with cumulative runtime timer |
| Mounting | 19-inch rack-mountable or desktop (with rubber feet) |
| Remote Channel Control | Yes |
| Controller Architecture | PLC-based with front-panel operational interface |
| Structural Design | Ruggedized for long-term field deployment and mobile operation |
| Compliance Basis | DRI Standard Method for Carbonyl Collection |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-5170 |
| Flow Rate | 39–60 CFM (1.1–1.7 m³/min) |
| Compliance | EPA 40 CFR Part 50, Appendix B |
| Calibration | Automatic microprocessor-controlled flow calibration |
| Data Logging | Internal SD card (CSV format), 5-minute interval logging of temperature, pressure, and actual flow rate |
| Flow Stability | ±1% of setpoint (maintained via real-time temperature & barometric pressure compensation) |
| Sample Compatibility | Standard EPA-approved 8×10 inch TSP filter holders |
| Power Supply | 120 VAC, 60 Hz |
| Enclosure | NEMA 4X-rated weatherproof cabinet |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-6070 |
| Flow Rate | 40 CFM (1.13 m³/min) |
| Cut-Point | PM₁₀ (≤10 µm aerodynamic diameter) |
| Filter Format | 8" × 10" (203 mm × 254 mm) |
| Flow Control Options | VFC (TE-10557) or MFC (TE-300-310) |
| Blower Motor | 1 HP, 2-pole vacuum motor |
| Timer | 7-day mechanical timer (TE-5007) or digital timer (TE-302) |
| Pressure Monitoring | 30-inch water manometer (TE-6001) |
| Data Recording | Continuous flow/pressure recorder (TE-5009) |
| Compliance | EPA Reference Method RFPS-0202-141, 40 CFR Part 50 Appendix L |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-6070 |
| Flow Control Options | VFC (TE-6070VFC) or MFC (TE-6070MFC) |
| Flow Rate | 40 cfm (1.133 m³/min), adjustable 1.02–1.24 m³/min (MFC) |
| Filter Medium | 8″ × 10″ quartz fiber filter (TE-QMA) |
| EPA Certification | RFPS-0202-141 (Federal Register Vol. 67, p. 15566, April 2, 2002) |
| Operating Temperature | −30 to 50 °C |
| Relative Humidity | 0–100% RH |
| Altitude Limit | Up to 10,000 ft ASL |
| Power Supply | 220 V / 50 Hz |
| Motor Options | Brushed or brushless |
| Timer Options | Common (C), Digital (D), or Plus (P) control systems |
| Dimensions & Weight | Multiple configurations — e.g., 45.5″ × 22.5″ × 20″ / 50–74 lbs |
| Current Draw | 12 A (startup), 7 A (VFC), 5 A (MFC) |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-6070V |
| Flow Rate | 40 CFM (1.13 m³/min, adjustable) |
| Filter Media | 8" × 10" Micro-Quartz (TE-QMA) |
| Flow Control | Mass Flow Controller (TE-300-310) or Volumetric Flow Controller (TE-10557PM10) |
| Vacuum Source | Two-stage blower, 0.6 HP |
| Power Supply | 110 V/60 Hz (TE-116311) or 220 V/50 Hz (TE-116312) |
| Data Logging | Internal SD card (CSV format), 5-min resolution for temperature, pressure, and flow |
| Compliance | EPA Reference Method RFPS-0202-141, 40 CFR Part 50, Appendix B |
| Calibration | Automatic field calibration with user-defined calibration factor |
| Flow Stability | ±1% of setpoint under varying ambient conditions (temperature & barometric pressure compensated) |
| Timer | 7-day mechanical programmable timer (TE-5007) |
| Elapsed Time Indicator | TE-5012 |
| Flow/Pressure Recorder | TE-5009 with TE-106 chart support |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-6070V-2.5-HVS |
| Flow Rate | 40 CFM (1.13 m³/min, adjustable) |
| Flow Stability | ±1% of setpoint (99% maintained under varying ambient conditions) |
| Filter Medium | 8" × 10" Micro-Quartz fiber filter (TE-QMA compatible) |
| Compliance | EPA Reference Method RFPS-0202-141, 40 CFR Part 50, Appendix B |
| Data Logging | Continuous 5-minute intervals (temperature, barometric pressure, actual flow rate) |
| Control System | Microprocessor-based with automatic MFC/VFC compensation |
| Power Supply | 110 V/60 Hz or 220 V/50 Hz, 0.6 HP dual-stage vacuum blower |
| Operating Current | 5 A (run), 12 A (inrush) |
| Timer | 7-day mechanical programmable timer (TE-5007) |
| Elapsed Time Indicator | TE-5012 |
| Flow Monitoring | TE-5009 continuous flow/pressure recorder with TE-106 chart compatibility |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-78-100 |
| Sampling Principle | Dual-Mode Sequential Deposition Collection |
| Housing Material | Powder-Coated Aluminum Frame |
| Actuation | Rain-Sensor-Triggered Motorized Lid Control |
| Collector Configuration | Symmetrical Dual-Collector Array |
| Operating Environment | Unmanned Field Deployment (–30 °C to +50 °C) |
| Compliance | ASTM D5926, ISO 10395, US EPA Method IO-3.3 |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Manufacturer | Tisch Environmental, Inc. |
| Model | TE-BC251 |
| Sampling Principle | Inertial Impaction via Multi-Stage Cyclonic Separation |
| Nominal Flow Rate | 3.5 L/min |
| Cut-Point Diameters (aerodynamic) | Stage 1: 4.9 µm, Stage 2: 1.7 µm, Stage 3: <0.4 µm |
| Compliance | Designed to NIOSH BC 251 Protocol |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | TE-PMD |
| Pricing | Available Upon Request |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-PNY1123 |
| Instrument Type | High-Flow Gas Sampler |
| Sampling Configuration | Single-Channel |
| Flow Rate Range | 120–750 L/min |
| Flow Stability | ±2% |
| Flowmeter Accuracy | ±2% |
| Continuous Operation Time at Max Flow & Backpressure | 24 h |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-Wilbur |
| Flow Range | 1–25 SLPM |
| Particle Cuts | TSP, PM10, PM2.5, PM1.0 (standard at 16.67 L/min) |
| Operating Temperature | −25 °C to +50 °C |
| Pressure Range | 450–1238 mmHg |
| Flow Accuracy | ±0.75 L/min |
| Flow Repeatability | ±0.25 L/min |
| Flow Resolution | 0.01 L/min |
| Power | 220 V AC / 40 W (solar/wind/battery options available) |
| Display | 5.7″ color touchscreen |
| Data Interface | USB, MODBUS RTU/TCP, RJ45 Ethernet |
| Weight | 18.1 kg (without battery), 21.3 kg (with battery) |
| Dimensions | 508 × 508 × 254 mm |
| Compliance | US EPA Reference/Equivalent Method per 40 CFR Part 53 & Appendix L |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-Wilbur |
| Sampling Flow Rate | 0–25 SLPM (standard operating flow: 16.67 L/min) |
| Dimensions | 508 × 508 × 254 mm |
| Weight | 21.3 kg (18.1 kg without battery) |
| Power | 120/240 VAC, 40 W |
| Operating Temperature | −25 °C to +50 °C |
| Flow Accuracy | ±0.75 L/min |
| Flow Repeatability | ±0.25 L/min |
| Flow Resolution | 0.01 L/min |
| Temperature Sensor (Ambient & Filter) | PT100 RTD, ±0.15 °C accuracy, 0.01 °C resolution |
| Barometric Pressure Sensor | 450–1238 mmHg, ±10.00 mmHg accuracy, 0.75 mmHg resolution |
| Communication | MODBUS RTU/TCP, USB 2.0, RJ45 Ethernet |
| Compliance | 40 CFR Part 53 Appendix L (FRM/FEM), ISO 9001 certified manufacturing |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | ZA-737-100 |
| Zero Air Purity | <1 ppb (for SO₂, NO, NO₂, NH₃, O₃, CO, H₂S, hydrocarbons, COS, SF₆, fluorocarbons) |
| Flow Rate | 100 L/min |
| Output Pressure | 80 psi |
| Dew Point | -50 °C |
| Flow Accuracy | ±1 L/min |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | ZA-737-250 |
| Zero Air Purity | <1 ppb (O₃, CH₄, hydrocarbons, NO/NOₓ, H₂S, SO₂, COS, CO, CO₂, SF₆, fluorocarbons) |
| Flow Rate | 250 L/min |
| Output Pressure | 80 psi |
| Dew Point | −50 °C |
| Flow Measurement Accuracy | ±1 L/min |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | ZA-737-50 |
| Zero Air Purity | <1 ppb (for SO₂, H₂S, NO, NO₂, NH₃, O₃, CO, hydrocarbons, CO₂, COS, SF₆, fluorocarbons) |
| Flow Rate | 50 L/min |
| Output Pressure | 80 psi |
| Dew Point | −50 °C |
| Flow Measurement Accuracy | ±1 L/min |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | ZA-747-10 |
| Zero Air Purity | <1 ppb THC (Total Hydrocarbons) and CH₄ |
| Flow Rate | 10 L/min |
| Output Pressure | 90 psi |
| Dew Point | −50 °C |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ZA-747-30 |
| Zero Air Purity | <1 ppb total hydrocarbons (as methane) |
| Zero Air Flow Rate | 30 L/min |
| Output Pressure | 90 psi |
| Dew Point | −50 °C |
| Flow Measurement Accuracy | ±2 L/min |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ZA10-240 |
| Zero Air Purity | <0.05 ppm (hydrocarbons & methane) |
| Flow Rate | 10 L/min |
| Output Pressure | 100 psi |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ZA30-240 |
| Zero Air Purity | <0.05 ppm (hydrocarbons and methane) |
| Flow Rate | 30 L/min |
| Output Pressure | 100 psi |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | ACOD-30 |
| Pricing | Upon Request |
| Instrument Type | Laboratory Benchtop |
| Measurement Principle | Dichromate Oxidation with Automated Potentiometric/Colorimetric Endpoint Detection (Compliant with HJ 828–2017) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | APIA-100 |
| Pricing | Available Upon Request |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Instrument Type | Laboratory Benchtop Analyzer |
| Repeatability | RSD ≤ 3.0% |
| Limit of Detection | ≤ 0.05 mg/L |
| Brand | TaiKun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TK-Mobius |
| Instrument Category | Gamma-Ray Spectrometer |
| Instrument Type | Laboratory-Based |
| Sample Form | Solid |
| Detector Type | High-Purity Germanium (HPGe) |
| Cooling Method | Liquid Nitrogen Recondensation (Closed-Cycle) |
| Operating Temperature | ≤ 77 K |
| Nominal Dewar Capacity | 28 L |
| Continuous Operation (Uninterrupted Power) | Up to 2 Years |
| Power Consumption | 125 W (Typical), 300 W (Max) |
| Ambient Operating Conditions | 0–40 °C, 20–90% RH (Non-Condensing) |
| Acoustic Noise Level | < 60 dB(A) at 1 m |
| Displayed Parameters | Cryocooler Status, Estimated Remaining Cryogenic Hold Time (h), LN₂ Level, Low-Level Warning Threshold (48 h) |
| Physical Dimensions (Dewar Only) | 66.5 cm H × 44.1 cm Ø |
| Air Filter Maintenance Interval | Monthly |
| Mounting Flexibility | Vertical or Horizontal Cold Finger Orientation |
| Electronics Architecture | Decoupled Cryo-Control and Signal Processing Circuitry (Separated from Dewar) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TLD3500 |
| Instrument Class | Radiation Dose Meter |
| Instrument Form Factor | Portable |
| Detectable Radiation Types | Photons (E > 5 keV), Neutrons (thermal–100 MeV), Beta particles (E > 70 keV) |
| Measurement Quantities | Photon dose, neutron fluence, beta dose |
| Dose Range | 10 μGy – 1 Gy (linear response) |
| Sensitivity Threshold | < 1 kGy |
| Temperature Range | 15 °C – 600 °C |
| Heating Rate | 1–50 °C/s |
| Temperature Stability | ±1 °C |
| System Stability | ±0.005% |
| Operating Ambient | 15–40 °C |
| Output Units | nC, gU, mrad, mrem, mGy, Gy, µSv, mSv, Sv |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | TMP-1500 |
| Pricing | Available Upon Request |
| Key | Brand: Restek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MNK123521 |
| Vacuum Pump | Edwards RV-8 |
| Max Temperature | 110 °C |
| Vacuum Level | ≤50 mTorr in ≤30 min (for 6 L canister) |
| Capacity | 12 × 6 L or 24 × 1 L canisters |
| Compliance | EPA Methods TO-14A & TO-15 |
| Control Interface | Integrated touchscreen controller with 10 programmable cleaning cycles |
| Cold Trap | Stainless steel vacuum/pressure-rated cold trap |
| Power Supply | 220–230 V, 50–60 Hz |
| Brand | Tongtai Lian (TTL) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | TTL-6HS |
| Instrument Type | Laboratory Benchtop System |
| Compliance | Designed per HJ 1226–2021 (PRC National Ecological and Environmental Standard) |
| Construction Materials | 316 Stainless Steel Frame + PTFE-Coated Components |
| Heating Method | Integrated Constant-Temperature Water Bath |
| Sample Capacity | 6 Independent Reaction Vessels |
| Gas Control | Individual Mass Flow Regulation per Channel (N₂) |
| Vertical Travel Range | 100 ± 2 mm |
| Sample Rack | Rotatable Circular Platform with Radial Mounting |
| Drainage | Stainless Steel Ball Valve |
| Electrical Isolation | Separated Water Bath and Control Unit Architecture |
| Corrosion Resistance | Certified for HCl, H₂SO₄, and NaOH Exposure (pH 1–14, ≤80 °C) |
| Brand | Tongtai Union (TTL) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TTL-4SH |
| Instrument Category | Laboratory Water Quality Analyzer |
| Analyte | Hydrogen Sulfide (H₂S) |
| Detection Method | Methylene Blue Spectrophotometry (per HJ 1226–2021 & GB 17378.4–2007) |
| Heating Range | Ambient to 90 °C |
| Temperature Accuracy | ±1 °C |
| Power Supply | AC 220 V, 50/60 Hz, 2000 W |
| Total Heating Power | 1800 W |
| Water Bath Capacity | 2000 mL × 4 positions |
| Nitrogen Flow Control | 0–10 L/min per channel |
| Stirring Speed Range | 0–3000 rpm |
| Stirring Control | Stepless (independent per sample) |
| Sample Rack Travel | 100 ±2 mm vertical lift |
| Construction Materials | Stainless steel frame with PTFE-coated internal components |
| Drain Valve | Stainless steel manual valve |
| Dimensions (W×D×H) | 540 × 520 × 835 mm |
| Brand | Tongtailian (TTL) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TTL-6SS |
| Instrument Type | Laboratory Benchtop System |
| Price Range | USD 2,800 – 7,000 (FOB China) |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Intelligent Service Platform |
| Pricing | Upon Request |