Environmental Monitoring Instruments
Filter
Showing 8041–8070 of 8980 results
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TZS-ECW-IG |
| Instrument Category | Soil Moisture / Water Potential Meter |
| Soil Parameter Range | 0–23 mS/cm (EC), –40–100 °C (Temp), 0–100% VWC (Moisture) |
| Accuracy | ±2% (EC), ±0.5 °C (Temp), ≤3% (VWC) |
| Resolution | 0.01 mS/cm, 0.1 °C, 0.1% VWC |
| Data Storage | 30,000 records (internal Flash), unlimited with optional 4GB microSD |
| Connectivity | 5G/4G cellular, USB, GPS geotagging |
| Power | 7.4 V / 2.8 Ah Li-ion battery (with low-voltage alert and charging protection), 8.4 V DC external input |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TZS-pH-IG |
| Price | Upon Request |
| pH Range | 0–14 |
| pH Accuracy | ±0.5 |
| Power Supply | 7.4 V / 2.8 Ah Rechargeable Lithium Battery |
| Data Storage | 30,000 records in internal Flash + expandable 4 GB microSD card |
| Connectivity | GPRS wireless transmission, USB data import, GPS geotagging |
| Sensor Interface | IP67-rated expansion hub supporting up to 32 sensor types |
| Operating System Support | Android & iOS mobile apps |
| Compliance | Designed for field-deployable environmental monitoring per ISO 10390:2022 (soil pH determination), supports GLP-aligned data traceability via timestamped, georeferenced records |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TZS-pH-IIG |
| Instrument Type | Soil pH Meter |
| Measurement Parameters | pH (0.0–14.0, ±0.1 accuracy, 0.1 resolution, single-point calibration) and Soil Temperature (−5°C to 70°C, ±0.5°C accuracy, 0.1°C resolution, automatic temperature compensation) |
| Operating Environment | −10°C to 55°C, 0–95% RH (non-condensing) |
| Power | Built-in 7.4 V / 2 Ah Li-ion battery |
| Standby Current | <20 mA |
| Max Operating Current | 300 mA |
| Onboard Storage | 30,000 records (Flash) +标配 4 GB TF card (expandable to 64 GB) |
| Data Logging Interval | 5 min – 99 h (user-configurable) |
| Connectivity | 2G/4G cellular, mini-USB, GPS positioning |
| Display | Chinese LCD with real-time clock, battery level, sensor values, storage status, voice status |
| Audio Alert | Mandarin voice播报 for threshold violations |
| Platform Integration | Cloud-based management platform with web & mobile access, data visualization, export (CSV/PDF), alarm configuration, crop-specific presets, audit-ready data history, remote firmware updates |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TZS-pHW-4G |
| Instrument Type | Soil Moisture / Water Potential Analyzer |
| Measurement Parameters | Soil Temperature, Soil Moisture (v/v %), Soil Electrical Conductivity (EC), Soil pH |
| Communication | GPRS + USB + Bluetooth (via App) |
| Data Storage | 30,000 internal Flash entries + expandable 4GB microSD |
| Power | 7.4V 2.8Ah rechargeable Li-ion battery (with low-voltage warning & charging protection) |
| GPS | Integrated high-sensitivity module (WGS84 coordinates, ±5 m CEP) |
| Sensor Interface | IP67-rated multi-channel hub supporting up to 32 sensors |
| Operating Temperature | -20°C to 60°C |
| Display | Backlit Chinese LCD with real-time timestamp, parameter values, storage status, and GPS coordinates |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TZS-pHW-4G |
| Instrument Type | Soil Moisture/Tension Analyzer |
| Communication | 5G/4G Cellular |
| Data Storage | 30,000 entries in internal Flash + expandable microSD (4 GB standard, unlimited with card) |
| Power Supply | 7.4 V / 2.8 Ah Li-ion battery (with low-voltage warning & charge protection) |
| external DC input | 8.4 V ≥1000 mA |
| Operating Current | 10 mA (standby), variable under active sensing |
| GPS | Integrated high-sensitivity module with automatic geotagging |
| Sensor Expansion | Up to 32 channels via IP67-rated daisy-chain hub |
| Display | Backlit Chinese LCD showing real-time values, timestamps, storage status, and system diagnostics |
| Sampling Interval | Configurable from 5 minutes to 99 hours |
| Audio Feedback | Mandarin voice prompts and threshold-triggered alarm announcements |
| Software Platform | Web- and mobile-accessible cloud management system (C/S architecture), supporting data visualization, export (CSV, PDF), reporting, audit-ready history, and OTA firmware updates |
| Soil Temperature Sensor | Range –40 to +100 °C, accuracy ±0.5 °C, resolution 0.1 °C, probe length ≥25 cm |
| Soil Electrical Conductivity (EC) Sensor | Solid-state electrode, range 0–23 mS/cm, accuracy ±2%, resolution 0.01 mS/cm |
| Soil Volumetric Water Content (VWC) Sensor | Range 0–100 %VWC, response time ≤2 s, resolution 0.1 %VWC, relative error ≤3%, standard cable 1.5 m (customizable up to 1000 m) |
| Soil pH Sensor | Range 0–14, accuracy ±0.5 pH units |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | TZS-pHWY-7G |
| Instrument Type | Multi-Function Soil Analyzer |
| Wireless Connectivity | 5G/4G Cellular |
| Onboard Storage | 30,000 records (Flash) + 4 GB microSD |
| GPS Integration | Built-in GNSS module (GPS+GLONASS) |
| Power Supply | 7.4 V / 2.8 Ah Li-ion battery (with low-voltage alert & charging protection) |
| Operating Current | 3 mA (standby), variable under active sensing |
| Data Logging Interval | 5 min – 99 h |
| Display | Backlit Chinese LCD with real-time timestamp, sensor values, storage status |
| Sensor Expansion | Up to 32 channels via IP67-rated daisy-chain hub |
| Environmental Rating | IP67-rated sensor interface |
| Communication Protocols | MQTT/HTTP over cellular |
| Compliance | Designed for field-deployable environmental monitoring per ISO 11277 (soil sampling), ASTM D4972 (pH), ASTM D511 (soluble salts), and USDA-NRCS soil testing guidelines |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | TZS-pHWY-7G |
| Instrument Category | Fertilizer & Nutrient Analyzer |
| Communication | 5G/4G Cellular |
| Onboard Storage | 30,000 records (Flash) + 4 GB microSD |
| Power | 7.4 V / 2.8 Ah Li-ion battery (with charging protection & low-voltage alert) |
| GPS | Integrated high-sensitivity module |
| Sensor Expansion | Up to 32 channels via IP67-rated daisy-chain interface |
| Data Upload | Automatic via cellular network or USB bulk transfer |
| Operating Temperature | –40 °C to +85 °C |
| Display | Backlit Chinese LCD with real-time timestamp, sensor values, storage status, and configuration menu |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Producer |
| Model | YD-1 |
| Instrument Category | Specialized Smoke Point Analyzer for Fats and Oils |
| Measurement Principle | Visual Observation of Blue Smoke Onset under Controlled Heating |
| Accuracy (Indication Error) | ±0.5% of full scale |
| Repeatability | ≤2% RSD |
| Response Time | ≤60 s |
| Stability (Drift over 4 h) | ≤5% of reading |
| Sample Type | Refined or Crude Vegetable Oils (e.g., soybean, rapeseed, palm, sunflower) |
| Dual-Test Reproducibility | ≤2 °C |
| Output | Analog mercury-in-glass thermometer + digital LED display |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | 0–40 °C, ≤80% RH |
| Dimensions (Main Unit) | 450 × 600 × 900 mm (L×W×H) |
| Dimensions (Control Panel) | 255 × 275 × 385 mm |
| Weight | 10 kg |
| Brand | TOPAS |
|---|---|
| Origin | Germany |
| Model | DDS-560 |
| Dilution Factor Range | 5–370 (flow-dependent) |
| Adjustable Sample Flow Rate | 0.5–3.0 L/min |
| Dilution Principle | Capillary Bypass with HEPA-Filtered Bypass Stream |
| Display | Real-time Flow & Dilution Ratio |
| Power Supply | 12 V DC, 300 mA |
| Dimensions (W×H×D) | 300 × 200 × 140 mm |
| Weight | 2.9 kg |
| Max Backpressure | ±35 kPa |
| Capillary Material | Brass |
| Inlet/Outlet Fitting | Ø8 mm |
| Compliance | VDI 3491-15, VDI 2083 |
| Brand | TOPAS |
|---|---|
| Origin | Germany |
| Model | DDU-570 |
| Instrument Type | Aerosol Conditioning Device |
| Design Variants | High-Profile (DDU-570/H) and Low-Profile (DDU-570/L) |
| Desiccant | Indicating Silica Gel (Type 830 for DDU-570/H |
| Max. Inlet Aerosol Flow Rate | 10 L/min (H) / 5 L/min (L) |
| Max. Inlet Aerosol Temperature | 40 °C |
| Operating Ambient Temperature | ≤40 °C |
| Dimensions (d × H) | 70 × 475 mm (H) / 70 × 253 mm (L) |
| Hose Connection | Ø 8 mm |
| Weight (empty) | 0.94 kg (H) / 0.72 kg (L) |
| Compliance | Designed for ISO 27427-compliant aerosol generation systems |
| Brand | TOPAS |
|---|---|
| Origin | Germany |
| Model | LAP323 |
| Principle | Dual-wavelength optical light scattering (660 nm red & 450 nm blue laser diodes) |
| Sample Flow Rate | 3.0 L/min (total), 0.1 L/min (measurement) |
| Particle Size Range | 0.15–40 µm |
| Counting Range | up to 10⁷ particles/L |
| Size Channels | 128 (user-definable) |
| Mass Concentration Range | up to 10⁴ pg/cm³ |
| Compliance | ISO 21501-1:2009, VDI 3867-4:2020(E) |
| Dimensions | 220 × 380 × 200 mm |
| Weight | 9.4 kg |
| Power | 110–230 VAC, 50–60 Hz or 12 VDC, 4.2 A |
| Brand | TOPAS |
|---|---|
| Origin | Germany |
| Model | SYS-520 |
| Power Supply | 24 V DC (via adapter) |
| Sample Path Options | Position 1, Position 2, or HEPA-filtered Purge |
| Hose Materials | Tygon® silicone (sampling), PVC (purge) |
| Hose Dimensions | Ø 4.7 × Ø 3.4 mm (Tygon-silicone), Ø 6.0 × Ø 4.0 mm (PVC) |
| Communication Interface | 3-pin connector (compatible with LAP 32X) |
| Dimensions (W × H × D) | 160 × 210 × 130 mm |
| Weight | 1.9 kg |
| Application | Dual-point aerosol sampling for fractional filter efficiency testing |
| Brand | TopCloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model Numbers | TP-WHL (Visible-light Imaging), TP-WHY (Multispectral Imaging) |
| Pricing | Available Upon Request |
| Brand | TOPWAY |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TW-2200C |
| Pricing | Upon Request |
| Sampling Principle | Solution Absorption (Gaseous Pollutants) + Filter Gravimetric Method (TSP/PM10/PM2.5) |
| Flow Control | Dual-channel Atmospheric Sampling + Single-channel Particulate Sampling |
| Flow Accuracy | ±2.5% of Full Scale |
| Flow Resolution | 0.001 L/min (Gas), 0.1 L/min (Particulate) |
| Time Setting Range | 1 min – 99 h 59 min |
| Temperature Compensation | Yes |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Temperature | −30 °C to +50 °C |
| Data Interface | RS232 Serial Port |
| Compliance Standards | JJG 956–2013, HJ 618–2011, HJ 93–2013 |
| Weight | ~7.0 kg |
| Dimensions (L×W×H) | 210 × 320 × 270 mm |
| Noise Level | ≤55 dB(A) |
| Brand | TOPWAY |
|---|---|
| Origin | Shandong, China |
| Model | TW-2650 |
| Sampling Flow Rate | 0.1–1.0 L/min |
| Flow Accuracy | ±2.0% (full scale) |
| Sampling Temperature Range | 0–500 °C |
| Gas Velocity Range | 0–45 m/s |
| Target Analytes | Elemental Mercury (Hg⁰) and Oxidized Mercury (Hg²⁺) |
| Brand | Torion |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TRIDION™-9 GC-TMS |
| Price | Upon Request |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Import Status | Imported |
| Model | Tox protectII |
| Instrument Type | Online Monitoring System |
| Test Organism | Live Fish (e.g., Danio rerio or Oncorhynchus mykiss) |
| Operating Temperature Range | 5–28 °C |
| Measurement Chamber Volume | 9 L (customizable) |
| Detection Principle | Real-time optical grating-based behavioral activity monitoring |
| Communication Interfaces | RS-485, Ethernet, Modbus TCP, optional GSM/SMS and analog alarm outputs |
| Alarm Modes | Local visual (tricolor LED), audible, remote SMS/fax/email via integrated gateway |
| Compliance | Designed for GLP-aligned operation |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PGM-1860 |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Model | TP-204 |
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Co., Ltd. |
| Type | Portable Multi-Gas Analyzer for SF₆ Decomposition Byproducts |
| Detection Principle | Electrochemical Sensors (SO₂, H₂S, CO) + Optional Metal-Oxide Semiconductor (for HF) |
| Flow Measurement | Imported Thermal Mass Flow Sensor (Accuracy ±2% FS) |
| Data Storage | 100 Test Records with Timestamp & ID Tagging |
| Display | 5-inch Color TFT Touchscreen (Graphical Trend + Numeric Readout) |
| Interface | USB 2.0 for Data Export to USB Flash Drive |
| Power | Rechargeable 4400 mAh Li-ion Battery (Up to 10 h Continuous Operation) |
| Calibration | Multi-Point Factory Calibration with On-Site Zero Adjustment and Temperature/Pressure Compensation |
| Sampling | Integrated Diaphragm Pump with Auto-Purge Function Post-Measurement |
| Compliance | Designed per IEC 62271-1 Annex J, IEEE C37.122.1, and DL/T 1535–2016 (China Power Industry Standard for SF₆ Decomposition Product Monitoring) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TQ-1000 |
| Pricing | Upon Request |
| Sampling Flow Ranges | 0.1–1.5 L/min, 0.1–2.0 L/min, or 0.1–3.0 L/min (user-selectable) |
| Flow Accuracy | ≤ ±5% |
| Timing Accuracy | ≤ ±1% |
| Maximum Negative Pressure | ≥25 kPa |
| Power Supply | 10 V DC (rechargeable Ni-Cd battery) / 220 V AC, 50 Hz |
| Operating Temperature | −10 °C to +45 °C |
| Relative Humidity | ≤85% RH |
| Weight | ~2.0 kg |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TQC-1500 |
| Pricing | Available Upon Request |
| Max. Vacuum Pressure | ≥25 kPa |
| Rated Flow at 40 mmHg | ≥1.5 L/min |
| Adjustable Flow Range | 0.1–1.5 L/min |
| Flow Accuracy | Class 2.5 |
| Flow Stability | ≤±5% |
| Timer Accuracy | ≤±1% |
| Operating Temperature | 5–40 °C |
| Power Supply | AC/DC dual-mode (8 V DC output) |
| Dimensions | 137 × 88 × 45 mm |
| Weight | <0.5 kg (including batteries) |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TR-II |
| Pricing | Available Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | TRAC |
| Pricing | Upon Request |
| Brand | Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPERT-TOC/TNb |
| Instrument Type | Laboratory TOC/TNb Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption for TOC |
| Oxidation Method | High-Temperature Catalytic Combustion (up to 1000 °C) |
| Measurement Range | 0–35,000 µg/L (ppb–ppm) |
| Accuracy | RSD < 1% |
| Resolution | 0.0001 µg/L |
| Detection Limit | 3 ppb (TOC) |
| Repeatability | RSD < 1% |
| Sample Introduction | Valve-Free Funnel-Tec™ Technology |
| Combustion Tube | ProCat™ High-Efficiency Catalytic Oxidation Tube |
| Autosampler | Integrated 65-Position Liquid Autosampler with On-Deck Stirring & Removable Tray |
| Software | TEIS v5.x (Compliant with FDA 21 CFR Part 11, GLP/GMP Audit Trail) |
| Brand | TE/Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER AOX |
| Measurement Principle | High-Temperature Combustion–Coulometric Titration |
| Measurement Range | 0.0025–1000 µg Cl/L |
| Accuracy | <3% @ 200 ppb Cl |
| Repeatability | <2.5% RSD |
| LOD | 0.0025 µg Cl |
| Resolution | 0.0025 µg Cl |
| Combustion Temperature | Up to 1150 °C |
| Sample Introduction | 5–1000 mg (solid) or 0.1–10 mL (liquid) |
| Analysis Time (per sample) | 3–10 min (excluding pre-treatment) |
| Carrier Gases | O₂ (99.6%), Ar (99.998%) |
| Autosampler | Standard 20-position, expandable to 60-position |
| Software | TEIS 2 Online Control & Data Processing Platform |
| Compliance | ISO 9562:2004, EN ISO 9562, DIN 38409-H17, EPA Method 1650, HJ 1214–2021, GB/T 34845–2017, GB/T 35613–2017, GB/T 41533–2022, GB/T 22904–2008, GB/T 15959 |
| Brand | Avantor |
|---|---|
| Origin | USA |
| Model | Traceable TDL/TGW |
| Wireless Protocol | Proprietary Self-Organizing Mesh RF |
| Max Nodes per Gateway | 30 |
| Sampling Interval | 1 min – 24 hr |
| Onboard Memory | 60,000 readings |
| Battery Life | >3 years (TDL), ≥12 hrs (TGW on backup) |
| IP Rating | IP65 (TDL), IP30 (TGW) |
| Operating Temp | −20°C to +60°C (TDL), −5°C to +45°C (TGW) |
| RF Range | >100 m line-of-sight, wall-penetrating |
| Sensor Compatibility | Digital, RS-485, PT100 |
| Data Resilience | Local caching + auto-resume transmission |
| Compliance | Supports 21 CFR Part 11 audit trail readiness, GLP/GMP-aligned data integrity architecture |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Traceable Environmental Monitoring System Architecture |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Tracer |
| Pricing | Upon Request |
| Brand | TRAD (Tests & Radiations) |
|---|---|
| Origin | France |
| Model | RayXpert 2.0 |
| Core Engine | Geant4 v11.2-based Monte Carlo simulation platform |
| Particle Support | γ, β⁻/β⁺, e⁻/e⁺, n, p, d, t, α, ³He, heavy ions |
| Source Types | Point, surface, volume, spectrum (user-defined or library-based), complex energy spectra |
| Geometry | Native 3D CAD modeling + STEP import (ISO 10303-21) |
| Material Definition | Custom elemental composition, density, mixture, isotopic enrichment |
| Output Metrics | Dose rate (Gy/h), absorbed dose (Gy), equivalent dose (Sv), fluence, particle tracks, path-integrated dose |
| Analysis Tools | Isodose contours, cross-sectional dose profiles, detector response simulation, multi-source/spectrum superposition, variance-reduced convergence monitoring (FOM) |
| Compliance Framework | Supports GLP-aligned audit trails, input/output logging, parameter versioning |
| Automation | Python API, CLI mode, JSON export for materials/sources, scriptable input generation |
| Licensing | Modular (SILVER/GOLD/PLATINUM), floating network license available |
| OS | Windows 10/11 (64-bit) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Transpector 2 |
| Pricing | Available Upon Request |